Subhomoy Chatterjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Subhomoy Chatterjee has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bikramjit Basu
Laboratory for Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore 560012, India
2 shared publications - Alok Kumar
Department of Materials Science and Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
1 shared publication Amit Roy Chowdhury
Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, India
1 shared publicationAmit RoyChowdhury
1 shared publicationJayanta Kumar Biswas
Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, India
1 shared publicationMainak Das
Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, India
1 shared publication
Latest Publications
- 3 July 2018
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (10) , 101014
Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene–20% hydroxyapatite–20% alumina (HDPE–20%HA–20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.
- 3 July 2018
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (10) , 101014
Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene–20% hydroxyapatite–20% alumina (HDPE–20%HA–20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.
- 1 January 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 70, 812-823
Microstructure and compression properties of 3D powder printed Ti-6Al-4V scaffolds with designed porosity: Experimental and computational analysis
- 1 January 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 70, 812-823
Microstructure and compression properties of 3D powder printed Ti-6Al-4V scaffolds with designed porosity: Experimental and computational analysis
- 1 January 2017
- Vol. 19 (2) , 11-20
Optimal selection of dental implant for different bone conditions based on the mechanical response.
Bone quality varies from one patient to another extensively. Young's modulus may deviate up to 40% of normal bone quality, which results into alteration of bone stiffness immensely. The prime goal of this study is to design the optimum dental implant considering the mechanical response at bone implant interfaces for a patient with specific bone quality. 3D models of mandible and natural molar tooth were prepared from CT scan data, while dental implants were modelled using different diameter, length and porosity and FE analysis was carried out. Based on the variation in bone density, five different bone qualities were considered. First, failure analysis of implants, under maximum biting force of 250 N had been performed. Next, the implants that remained were selected for observation of mechanical response at bone implant interfaces under common chewing load of 120 N. Maximum Von Mises stress did not surpass the yield strength of the implant material (TiAl4V). However, factor of safety of 1.5 was considered and all but two dental implants survived the design stress or allowable stress. Under 120 N load, distribution of Von Mises stress and strain at the boneimplant interface corresponding to the rest of the implants for five bone conditions were obtained and enlisted. Implants exhibiting interface strain within 1500-3000 microstrain range show the best bone remodelling and osseointegration. So, implant models having this range of interface strains were selected corresponding to the particular bone quality. A set of optimum dental implants for each of the bone qualities were predicted.
- 1 January 2017
- Vol. 19 (2) , 11-20
Optimal selection of dental implant for different bone conditions based on the mechanical response.
Bone quality varies from one patient to another extensively. Young's modulus may deviate up to 40% of normal bone quality, which results into alteration of bone stiffness immensely. The prime goal of this study is to design the optimum dental implant considering the mechanical response at bone implant interfaces for a patient with specific bone quality. 3D models of mandible and natural molar tooth were prepared from CT scan data, while dental implants were modelled using different diameter, length and porosity and FE analysis was carried out. Based on the variation in bone density, five different bone qualities were considered. First, failure analysis of implants, under maximum biting force of 250 N had been performed. Next, the implants that remained were selected for observation of mechanical response at bone implant interfaces under common chewing load of 120 N. Maximum Von Mises stress did not surpass the yield strength of the implant material (TiAl4V). However, factor of safety of 1.5 was considered and all but two dental implants survived the design stress or allowable stress. Under 120 N load, distribution of Von Mises stress and strain at the boneimplant interface corresponding to the rest of the implants for five bone conditions were obtained and enlisted. Implants exhibiting interface strain within 1500-3000 microstrain range show the best bone remodelling and osseointegration. So, implant models having this range of interface strains were selected corresponding to the particular bone quality. A set of optimum dental implants for each of the bone qualities were predicted.
- 1 April 2016
- Published by American Scientific Publishers in Journal of Medical Imaging and Health Informatics
- Vol. 6 (2) , 269-284
Review: Problems with Use of Trans-Tibial Prosthesis
Discomfort and elevated energy consumption is still a common companion of many prosthetic users, generally due to altered loading condition which the body is not adapted to, preventing them to participate actively in the society. The socket, being an interface between body and prosthesis, is believed to be the most important concern regarding comfort of prosthetic use. The main cause of problem is altered gait dynamics. Local stress concentration, friction and slippage, confinement into warm moist environment inside socket, etc. adds to discomfort. The stump, being a living part, is also subjected to variations. These produce various soft tissue problems and enhance energy expenditure. This can be somewhat countered by even distribution of load along stump. In this review article, papers regarding biomechanics and pathomechanics of prosthetic gait, the mechanical and corresponding medical problems and suggested solutions have been studied in details. 59% of Trans-Tibial amputees and 78% of Trans-Femoral amputees are found to have problems with socket fit. This results in skin irritations in 41% of TT amputees and 22% of TF amputees. The main problems are regional stress concentration, friction and rubbing of stump along socket and energy expenditure. Hydrostatic total surface bearing and variable geometry fitting socket has been hypothesized to counter this problem though they are also having their own limitations.
- 1 April 2016
- Published by American Scientific Publishers in Journal of Medical Imaging and Health Informatics
- Vol. 6 (2) , 269-284
Review: Problems with Use of Trans-Tibial Prosthesis
Discomfort and elevated energy consumption is still a common companion of many prosthetic users, generally due to altered loading condition which the body is not adapted to, preventing them to participate actively in the society. The socket, being an interface between body and prosthesis, is believed to be the most important concern regarding comfort of prosthetic use. The main cause of problem is altered gait dynamics. Local stress concentration, friction and slippage, confinement into warm moist environment inside socket, etc. adds to discomfort. The stump, being a living part, is also subjected to variations. These produce various soft tissue problems and enhance energy expenditure. This can be somewhat countered by even distribution of load along stump. In this review article, papers regarding biomechanics and pathomechanics of prosthetic gait, the mechanical and corresponding medical problems and suggested solutions have been studied in details. 59% of Trans-Tibial amputees and 78% of Trans-Femoral amputees are found to have problems with socket fit. This results in skin irritations in 41% of TT amputees and 22% of TF amputees. The main problems are regional stress concentration, friction and rubbing of stump along socket and energy expenditure. Hydrostatic total surface bearing and variable geometry fitting socket has been hypothesized to counter this problem though they are also having their own limitations.