Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone
- 3 July 2018
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (10) , 101014
Abstract
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene–20% hydroxyapatite–20% alumina (HDPE–20%HA–20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.Keywords
Funding Information
- "Department of Biotechnology , Ministry of Science and Technology" (DBTO0455)
- "Department of Science and Technology, Ministry of Science and Technology" (DSTO1303)
This publication has 84 references indexed in Scilit:
- Metal-on-metal joint bearings and hematopoetic malignancyActa Orthopaedica, 2012
- Evaluation of physico-mechanical properties and in vitro biocompatibility of compression molded HDPE based biocomposites with HA/Al2O3 ceramic fillers and titanate coupling agentsJournal of Applied Polymer Science, 2011
- Bioengineering reasons for the failure of metal-on-metal hip prosthesesThe Journal of Bone and Joint Surgery. British volume, 2011
- Accelerating failure rate of the ASR total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Theoretically optimum position of the prosthesis in total hip arthroplasty to fulfill the severe range of motion criteria due to neck impingementJournal of Orthopaedic Science, 2011
- Acetabular Polyethylene Wear and Acetabular Inclination and Femoral OffsetClinical Orthopaedics and Related Research, 2009
- (ii) Impingement in total hip replacement: mechanisms and consequencesCurrent Orthopaedics, 2008
- A novel ultra high molecular weight polyethylene–hyaluronan microcomposite for use in total joint replacements. II. Mechanical and tribological property evaluationJournal of Biomedical Materials Research Part A, 2007
- Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graftThe Journal of Bone and Joint Surgery. British volume, 2007
- Evaluation o biocompatibility of various ceramic powders with human fibroblasts in vitroClinical Materials, 1993