Xiaojun Lu has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Wang Xiang
State Key Laboratory of Advanced Electromagnetic Technology, Huazhong University of Science and Technology, Wuhan, China
8 shared publications Jinyu Wen
5 shared publications- Jinyu Wen
Huazhong University of Science and Technology
5 shared publications Weixing Lin
4 shared publications- Weixing Lin
TBEA SunOasis Co,. Ltd, Urumuchi 830011, Xinjiang, China
3 shared publications Daijun Luo
2 shared publications
Latest Publications
- Open Access
- 14 June 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1052-1059
An AC active power regulation method for MMC by employing the internal energy
- 14 June 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1052-1059
Open AccessAn AC active power regulation method for MMC by employing the internal energy
- Open Access
- 1 November 2021
- Published by Elsevier in Energy Reports
- Vol. 7, 538-544
Comprehensive small-signal stability analysis for master hybrid MMC connected with strong and weak AC systems
- 1 November 2021
- Published by Elsevier in Energy Reports
- Vol. 7, 538-544
Open AccessComprehensive small-signal stability analysis for master hybrid MMC connected with strong and weak AC systems
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (2) , 880-892
Impact of Strength and Proximity of Receiving AC Systems on Cascaded LCC-MMC Hybrid HVDC System
The cascaded hybrid LCC-MMC inverter is considered as a feasible option to mitigate the commutation failure problem of conventional LCC-HVDC while maintaining bulk power transmission capability. However, the coupling between different types of converters may result in instability when the inverter integrates with weak AC systems. This paper establishes a small-signal model of the cascaded LCC-MMC inverter based hybrid HVDC system and validates the model against PSCAD/EMTDC. Through eigenvalue analysis, the impact of the strength and proximity of receiving AC systems on the small-signal stability is investigated, and the stable zone of the strength of receiving AC systems is identified. Besides, a supplementary coupling mitigation control is proposed to tackle the instability problem under weak AC systems integration. Both analytical results and time-domain simulations demonstrate the validity of the supplementary control.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (2) , 880-892
Impact of Strength and Proximity of Receiving AC Systems on Cascaded LCC-MMC Hybrid HVDC System
The cascaded hybrid LCC-MMC inverter is considered as a feasible option to mitigate the commutation failure problem of conventional LCC-HVDC while maintaining bulk power transmission capability. However, the coupling between different types of converters may result in instability when the inverter integrates with weak AC systems. This paper establishes a small-signal model of the cascaded LCC-MMC inverter based hybrid HVDC system and validates the model against PSCAD/EMTDC. Through eigenvalue analysis, the impact of the strength and proximity of receiving AC systems on the small-signal stability is investigated, and the stable zone of the strength of receiving AC systems is identified. Besides, a supplementary coupling mitigation control is proposed to tackle the instability problem under weak AC systems integration. Both analytical results and time-domain simulations demonstrate the validity of the supplementary control.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (6) , 7408-7421
Analysis of Wideband Oscillation of Hybrid MMC Interfacing Weak AC Power System
The wide-band oscillation of the hybrid MMC induced by excessive power infeed under weak AC power system integration is analyzed in this paper. A closed-loop state-space-based time-domain small-signal model is firstly established to investigate the instability problem. Different from the findings in two-level VSCs or half-bridge MMCs, the root locus analysis and participation factor analysis in this paper reveals that the oscillation frequency and involved control loops are highly related to the operation status. When hybrid MMC operates as a rectifier, a low-frequency oscillation is observed with the d-channel control loop mainly participated. In contrast, a high-frequency oscillation occurs with a q-channel control loop mainly involved when the hybrid MMC operates as an inverter. This wide-band oscillation phenomenon is explored with the aid of two simplified loop-gain-based s-domain models, which are derived referring to the selective modal analysis approach. To suppress the oscillation, sensitivity analysis regarding the impact of parameters on the phase margin is conducted to recognize effective parameter adjustment methods. The analysis results are validated by detailed electromagnetic simulations.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (6) , 7408-7421
Analysis of Wideband Oscillation of Hybrid MMC Interfacing Weak AC Power System
The wide-band oscillation of the hybrid MMC induced by excessive power infeed under weak AC power system integration is analyzed in this paper. A closed-loop state-space-based time-domain small-signal model is firstly established to investigate the instability problem. Different from the findings in two-level VSCs or half-bridge MMCs, the root locus analysis and participation factor analysis in this paper reveals that the oscillation frequency and involved control loops are highly related to the operation status. When hybrid MMC operates as a rectifier, a low-frequency oscillation is observed with the d-channel control loop mainly participated. In contrast, a high-frequency oscillation occurs with a q-channel control loop mainly involved when the hybrid MMC operates as an inverter. This wide-band oscillation phenomenon is explored with the aid of two simplified loop-gain-based s-domain models, which are derived referring to the selective modal analysis approach. To suppress the oscillation, sensitivity analysis regarding the impact of parameters on the phase margin is conducted to recognize effective parameter adjustment methods. The analysis results are validated by detailed electromagnetic simulations.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4482-4499
Comparative Study of Small-Signal Stability Under Weak AC System Integration for Different VSCs
Voltage source converters (VSCs) with self-commutation ability are suitable to interconnect weak AC systems. This paper conducts a comparative study of the small-signal stability characteristics for three typical VSCs, namely, the two-level VSCs (TL-VSCs), the half-bridge modular multilevel converters (HB-MMCs) and the hybrid MMCs (HY-MMCs), under weak AC system integration with special consideration on both inverter and rectifier operation. The frequency responses based on impedance models are compared using the frequency-domain analysis. The oscillation frequencies and mainly participated state variables of the unstable modes are compared using root locus and participation factor analysis in time-domain. Proper parameter retuning approaches for stability enhancement are proposed. The above analysis is adequately validated by electromagnetic simulations.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4482-4499
Comparative Study of Small-Signal Stability Under Weak AC System Integration for Different VSCs
Voltage source converters (VSCs) with self-commutation ability are suitable to interconnect weak AC systems. This paper conducts a comparative study of the small-signal stability characteristics for three typical VSCs, namely, the two-level VSCs (TL-VSCs), the half-bridge modular multilevel converters (HB-MMCs) and the hybrid MMCs (HY-MMCs), under weak AC system integration with special consideration on both inverter and rectifier operation. The frequency responses based on impedance models are compared using the frequency-domain analysis. The oscillation frequencies and mainly participated state variables of the unstable modes are compared using root locus and participation factor analysis in time-domain. Proper parameter retuning approaches for stability enhancement are proposed. The above analysis is adequately validated by electromagnetic simulations.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 4086-4099
An Improved DC Fault Protection Algorithm for MMC HVDC Grids Based on Modal-Domain Analysis
To detect the DC faults for MMC based DC grids using overhead line transmission, many protection methods in phase-domain have been proposed. These existing protection methods suffer from incomplete function, weak theoretical basis and sensitivity to fault resistance and noise disturbance. To overcome these shortcomings, this paper proposes an improved DC fault protection algorithm using the modal-domain approach for the MMC based overhead DC grids, which decouples interaction between positive and negative poles and mitigates the strong frequency-dependency of the characteristic impedance in phase-domain. The DC fault equivalent circuits are established in modal-domain and the fault characteristics during the initial stage are analysed. Based on the modal-domain analysis, the line-mode reactor voltage which combines fault characteristics of negative and positive reactor voltages, is employed to identify the internal faults. The zero-mode reactor voltage which enlarges the differences between faulty and healthy poles, is employed to select the faulted pole. This method is robust to fault resistance and noise with high detection speed. In addition, it is not affected by power reversal, AC faults and DCCB operation, which are validated and evaluated by simulations in PSCAD/EMTDC.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 4086-4099
An Improved DC Fault Protection Algorithm for MMC HVDC Grids Based on Modal-Domain Analysis
To detect the DC faults for MMC based DC grids using overhead line transmission, many protection methods in phase-domain have been proposed. These existing protection methods suffer from incomplete function, weak theoretical basis and sensitivity to fault resistance and noise disturbance. To overcome these shortcomings, this paper proposes an improved DC fault protection algorithm using the modal-domain approach for the MMC based overhead DC grids, which decouples interaction between positive and negative poles and mitigates the strong frequency-dependency of the characteristic impedance in phase-domain. The DC fault equivalent circuits are established in modal-domain and the fault characteristics during the initial stage are analysed. Based on the modal-domain analysis, the line-mode reactor voltage which combines fault characteristics of negative and positive reactor voltages, is employed to identify the internal faults. The zero-mode reactor voltage which enlarges the differences between faulty and healthy poles, is employed to select the faulted pole. This method is robust to fault resistance and noise with high detection speed. In addition, it is not affected by power reversal, AC faults and DCCB operation, which are validated and evaluated by simulations in PSCAD/EMTDC.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1111-1123
An Adaptive Reclosing Strategy for MMC-HVDC Systems With Hybrid DC Circuit Breakers
Modular multilevel converter (MMC) based high voltage direct current transmission (HVDC) is an effective solution for large-scale renewable power integration over long-distance. In the overhead MMC-HVDC systems, the high voltage DC circuit breakers (DCCB) are implemented to interrupt the DC fault current. Subsequent to fault isolation, the DCCBs are required to automatically re-close to restore power transmission quickly. However, when the DCCBs are re-closed to permanent faults, they will be tripped again, resulting in a high requirement of interruption capacity for DCCBs and second overcurrent strikes on the HVDC systems. To overcome the drawbacks of the conventional auto-reclosing scheme, this paper proposes an adaptive reclosing scheme based on the active pulse injection from the converter associated with the coordination control of hybrid DCCBs. The single-end adaptive reclosing scheme as well as two ends adaptive reclosing scheme dedicated to two-terminal HVDC systems and meshed DC grids are presented respectively. By applying this method, the location of faults can also be achieved in the case of permanent faults. In order to verify the effectiveness of the proposed adaptive reclosing schemes, extensive simulations have been conducted under PSCAD/EMTDC.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1111-1123
An Adaptive Reclosing Strategy for MMC-HVDC Systems With Hybrid DC Circuit Breakers
Modular multilevel converter (MMC) based high voltage direct current transmission (HVDC) is an effective solution for large-scale renewable power integration over long-distance. In the overhead MMC-HVDC systems, the high voltage DC circuit breakers (DCCB) are implemented to interrupt the DC fault current. Subsequent to fault isolation, the DCCBs are required to automatically re-close to restore power transmission quickly. However, when the DCCBs are re-closed to permanent faults, they will be tripped again, resulting in a high requirement of interruption capacity for DCCBs and second overcurrent strikes on the HVDC systems. To overcome the drawbacks of the conventional auto-reclosing scheme, this paper proposes an adaptive reclosing scheme based on the active pulse injection from the converter associated with the coordination control of hybrid DCCBs. The single-end adaptive reclosing scheme as well as two ends adaptive reclosing scheme dedicated to two-terminal HVDC systems and meshed DC grids are presented respectively. By applying this method, the location of faults can also be achieved in the case of permanent faults. In order to verify the effectiveness of the proposed adaptive reclosing schemes, extensive simulations have been conducted under PSCAD/EMTDC.
- 1 October 2018
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 101, 25-37
Small-signal modeling of MMC based DC grid and analysis of the impact of DC reactors on the small-signal stability
- 1 October 2018
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 101, 25-37
Small-signal modeling of MMC based DC grid and analysis of the impact of DC reactors on the small-signal stability
- 1 September 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 162, 99-108
State-space model and PQ operating zone analysis of hybrid MMC
- 1 September 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 162, 99-108
State-space model and PQ operating zone analysis of hybrid MMC
- Open Access
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2281-2286
Analytical model of hybrid MMC for dynamic and steady‐state studies
This study researched the analytical models for the modular multilevel converter (MMC) with its arm mixed with half‐bridge submodules and full‐bridge submodules, named as hybrid MMC. The state‐space model and steady‐state model of hybrid MMC under rotating frame are proposed. The phasor modelling method is employed to describe the internal dynamics of the converter. Modulation signals combined with the elementary control of hybrid MMC are considered in the modelling. The accuracy of the analytical models is verified by extensive time‐domain simulation in contrast with PSCAD/EMTDC models. A ‘select and check’ method is proposed to determine the feasible operating zone of hybrid MMC considering multiple operating constraints. The operating zones of the test hybrid MMC under different DC voltage levels are analysed.
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2281-2286
Open AccessAnalytical model of hybrid MMC for dynamic and steady‐state studies
This study researched the analytical models for the modular multilevel converter (MMC) with its arm mixed with half‐bridge submodules and full‐bridge submodules, named as hybrid MMC. The state‐space model and steady‐state model of hybrid MMC under rotating frame are proposed. The phasor modelling method is employed to describe the internal dynamics of the converter. Modulation signals combined with the elementary control of hybrid MMC are considered in the modelling. The accuracy of the analytical models is verified by extensive time‐domain simulation in contrast with PSCAD/EMTDC models. A ‘select and check’ method is proposed to determine the feasible operating zone of hybrid MMC considering multiple operating constraints. The operating zones of the test hybrid MMC under different DC voltage levels are analysed.