Weixing Lin
Research Subjects
Weixing Lin has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Wang Xiang
State Key Laboratory of Advanced Electromagnetic Technology, Huazhong University of Science and Technology, Wuhan, China
13 shared publications Jinyu Wen
State Key Laboratory of Advanced Electromagnetic Engineering and Technology Huazhong University of Science and Technology Wuhan 430074 Hubei People's Republic of China
10 shared publications- Jinyu Wen
Huazhong University of Science and Technology
8 shared publications Dragan Jovcic
6 shared publications- Dragan Jovcic
University of Aberdeen
4 shared publications - Meng Zhou
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
3 shared publications
Latest Publications
- 24 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (2) , 1054-1066
Resilient DC Voltage Control for Islanded Wind Farms Integration Using Cascaded Hybrid HVDC System
To integrate large-scale islanded onshore wind power with different sizes, this paper proposes an integration system based on the cascaded hybrid HVDC transmission system, which consists of LCC and several MMCs in series connection at the DC side of the rectifier. A large-scale wind farm is connected with one LCC and one MMC while several small-scale wind farms are connected with MMCs directly. Owing to the hierarchical integration arrangement, the operating flexibility can be improved with reduced capacity and the number of step-up interfacing transformers. A resilient DC voltage control is proposed for the integration system to adaptively redistribute power among the converters during wind power fluctuations. Firstly, the topology and operating characteristics of the wind power integration system are introduced. Then, a resilient DC voltage control is proposed to ensure stable operation during wind power curtailments. Finally, a simulation model of the hybrid cascaded HVDC transmission system is built in PSCAD/EMTDC to verify the effectiveness. The research results show that the system provides a new option for long-distance transmission of large-scale islanded wind power.
- 24 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (2) , 1054-1066
Resilient DC Voltage Control for Islanded Wind Farms Integration Using Cascaded Hybrid HVDC System
To integrate large-scale islanded onshore wind power with different sizes, this paper proposes an integration system based on the cascaded hybrid HVDC transmission system, which consists of LCC and several MMCs in series connection at the DC side of the rectifier. A large-scale wind farm is connected with one LCC and one MMC while several small-scale wind farms are connected with MMCs directly. Owing to the hierarchical integration arrangement, the operating flexibility can be improved with reduced capacity and the number of step-up interfacing transformers. A resilient DC voltage control is proposed for the integration system to adaptively redistribute power among the converters during wind power fluctuations. Firstly, the topology and operating characteristics of the wind power integration system are introduced. Then, a resilient DC voltage control is proposed to ensure stable operation during wind power curtailments. Finally, a simulation model of the hybrid cascaded HVDC transmission system is built in PSCAD/EMTDC to verify the effectiveness. The research results show that the system provides a new option for long-distance transmission of large-scale islanded wind power.
- Open Access
- 3 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5631-5645
A Differential Pilot Protection Scheme for MMC-Based DC Grid Resilient to Communication Failure
Primary single-end line protection strategies of MMC HVDC systems are difficult to make a tradeoff between fast detection speed and high reliability. To improve reliability, the pilot protection schemes based on communication and data exchange can be adopted. However, the communication-based schemes suffer from potential communication failure problems, such as data error, data loss and time synchronization error. To avoid blocking of protection devices during communication failures, a resilience-oriented differential pilot protection method is proposed in this paper. To address the problem of synchronization error, a startup element based on the multi-resolution morphological gradient (MMG) of traveling wave is proposed. For the problems of data error and data loss in communication, the sampled data are preprocessed by the morphological filtering (MF). And the correlation of traveling waves is used to identify the internal and external faults; the ratio of the morphological gradient of pole voltages is adopted to discriminate the faulty poles. A four-terminal MMC based DC grid model is built in PSCAD/EMTDC interfaced with the optical fiber-based communication system built in MATLAB/Simulink. The simulation results show that the protection scheme can effectively identify the faults against serious communication problems of 1% bit error rate and 5% data loss.
- 3 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5631-5645
Open AccessA Differential Pilot Protection Scheme for MMC-Based DC Grid Resilient to Communication Failure
Primary single-end line protection strategies of MMC HVDC systems are difficult to make a tradeoff between fast detection speed and high reliability. To improve reliability, the pilot protection schemes based on communication and data exchange can be adopted. However, the communication-based schemes suffer from potential communication failure problems, such as data error, data loss and time synchronization error. To avoid blocking of protection devices during communication failures, a resilience-oriented differential pilot protection method is proposed in this paper. To address the problem of synchronization error, a startup element based on the multi-resolution morphological gradient (MMG) of traveling wave is proposed. For the problems of data error and data loss in communication, the sampled data are preprocessed by the morphological filtering (MF). And the correlation of traveling waves is used to identify the internal and external faults; the ratio of the morphological gradient of pole voltages is adopted to discriminate the faulty poles. A four-terminal MMC based DC grid model is built in PSCAD/EMTDC interfaced with the optical fiber-based communication system built in MATLAB/Simulink. The simulation results show that the protection scheme can effectively identify the faults against serious communication problems of 1% bit error rate and 5% data loss.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (6) , 7408-7421
Analysis of Wideband Oscillation of Hybrid MMC Interfacing Weak AC Power System
The wide-band oscillation of the hybrid MMC induced by excessive power infeed under weak AC power system integration is analyzed in this paper. A closed-loop state-space-based time-domain small-signal model is firstly established to investigate the instability problem. Different from the findings in two-level VSCs or half-bridge MMCs, the root locus analysis and participation factor analysis in this paper reveals that the oscillation frequency and involved control loops are highly related to the operation status. When hybrid MMC operates as a rectifier, a low-frequency oscillation is observed with the d-channel control loop mainly participated. In contrast, a high-frequency oscillation occurs with a q-channel control loop mainly involved when the hybrid MMC operates as an inverter. This wide-band oscillation phenomenon is explored with the aid of two simplified loop-gain-based s-domain models, which are derived referring to the selective modal analysis approach. To suppress the oscillation, sensitivity analysis regarding the impact of parameters on the phase margin is conducted to recognize effective parameter adjustment methods. The analysis results are validated by detailed electromagnetic simulations.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (6) , 7408-7421
Analysis of Wideband Oscillation of Hybrid MMC Interfacing Weak AC Power System
The wide-band oscillation of the hybrid MMC induced by excessive power infeed under weak AC power system integration is analyzed in this paper. A closed-loop state-space-based time-domain small-signal model is firstly established to investigate the instability problem. Different from the findings in two-level VSCs or half-bridge MMCs, the root locus analysis and participation factor analysis in this paper reveals that the oscillation frequency and involved control loops are highly related to the operation status. When hybrid MMC operates as a rectifier, a low-frequency oscillation is observed with the d-channel control loop mainly participated. In contrast, a high-frequency oscillation occurs with a q-channel control loop mainly involved when the hybrid MMC operates as an inverter. This wide-band oscillation phenomenon is explored with the aid of two simplified loop-gain-based s-domain models, which are derived referring to the selective modal analysis approach. To suppress the oscillation, sensitivity analysis regarding the impact of parameters on the phase margin is conducted to recognize effective parameter adjustment methods. The analysis results are validated by detailed electromagnetic simulations.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4482-4499
Comparative Study of Small-Signal Stability Under Weak AC System Integration for Different VSCs
Voltage source converters (VSCs) with self-commutation ability are suitable to interconnect weak AC systems. This paper conducts a comparative study of the small-signal stability characteristics for three typical VSCs, namely, the two-level VSCs (TL-VSCs), the half-bridge modular multilevel converters (HB-MMCs) and the hybrid MMCs (HY-MMCs), under weak AC system integration with special consideration on both inverter and rectifier operation. The frequency responses based on impedance models are compared using the frequency-domain analysis. The oscillation frequencies and mainly participated state variables of the unstable modes are compared using root locus and participation factor analysis in time-domain. Proper parameter retuning approaches for stability enhancement are proposed. The above analysis is adequately validated by electromagnetic simulations.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4482-4499
Comparative Study of Small-Signal Stability Under Weak AC System Integration for Different VSCs
Voltage source converters (VSCs) with self-commutation ability are suitable to interconnect weak AC systems. This paper conducts a comparative study of the small-signal stability characteristics for three typical VSCs, namely, the two-level VSCs (TL-VSCs), the half-bridge modular multilevel converters (HB-MMCs) and the hybrid MMCs (HY-MMCs), under weak AC system integration with special consideration on both inverter and rectifier operation. The frequency responses based on impedance models are compared using the frequency-domain analysis. The oscillation frequencies and mainly participated state variables of the unstable modes are compared using root locus and participation factor analysis in time-domain. Proper parameter retuning approaches for stability enhancement are proposed. The above analysis is adequately validated by electromagnetic simulations.
- 25 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 920-931
An Adaptive Fault Current Limiting Control for MMC and Its Application in DC Grid
This paper proposes an adaptive fault current limiting control (AFCLC) for modular multilevel converters (MMC). Without introducing extra current limiting devices, this control scheme enables fast fault current suppression during DC faults. The AFCLC will be triggered automatically once DC faults occur. By adaptively reducing the output DC voltages of MMCs, the fault current can be suppressed. Compared with the existing current limiting methods, the proposed AFCLC has a better performance on fault current limiting, since it only depends on the real-time operating condition and no fault detection delay is imposed. Firstly, the principle of the proposed AFCLC together with the mathematical analysis is disclosed. Then, the sensitivity analysis of the impact of key control parameters on the current limiting effect is investigated. Finally, the effectiveness of AFCLC is demonstrated in a four-terminal HVDC grid test model. The simulation results show that the proposed AFCLC can reduce the interrupted current and energy absorption of a DCCB from 10.39 kA and 38.24 MJ to 4.62 kA and 8.32 MJ, respectively. The simulation results also prove that the AFCLC will not affect the accuracy of the DC fault detection algorithms under DC faults.
- 25 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 920-931
An Adaptive Fault Current Limiting Control for MMC and Its Application in DC Grid
This paper proposes an adaptive fault current limiting control (AFCLC) for modular multilevel converters (MMC). Without introducing extra current limiting devices, this control scheme enables fast fault current suppression during DC faults. The AFCLC will be triggered automatically once DC faults occur. By adaptively reducing the output DC voltages of MMCs, the fault current can be suppressed. Compared with the existing current limiting methods, the proposed AFCLC has a better performance on fault current limiting, since it only depends on the real-time operating condition and no fault detection delay is imposed. Firstly, the principle of the proposed AFCLC together with the mathematical analysis is disclosed. Then, the sensitivity analysis of the impact of key control parameters on the current limiting effect is investigated. Finally, the effectiveness of AFCLC is demonstrated in a four-terminal HVDC grid test model. The simulation results show that the proposed AFCLC can reduce the interrupted current and energy absorption of a DCCB from 10.39 kA and 38.24 MJ to 4.62 kA and 8.32 MJ, respectively. The simulation results also prove that the AFCLC will not affect the accuracy of the DC fault detection algorithms under DC faults.
- Open Access
- 6 December 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (2) , 222-230
Energy dissipation of MMC‐HVDC based onshore wind power integration system with FB‐DBS and DCCB
With the development of high‐voltage direct current (HVDC), modular multilevel converter (MMC) is seeking its application in onshore wind power integration. AC and DC faults are important issues for the wind power integration system, during which the wind generation system continuously provides wind power and the surplus power may cause overvoltage to sub‐modules of MMC. This study focuses on the energy dissipation during AC and DC faults for the overhead‐line MMC‐HVDC system integrating large‐scale wind power. A two‐terminal MMC‐HVDC system with permanent magnet synchronous generator based wind farm is studied. Hybrid DC circuit breakers (DCCBs) are employed to interrupt DC fault current and the method based on measuring the rate of change of DC line voltage is adopted to trip DCCBs. Also a full‐bridge sub‐module based dynamic braking system (FB‐DBS) is implemented at the DC link to absorb the surplus wind power in case of AC or DC faults in the HVDC grid. To ride‐through AC and DC faults without blocking IGBTs, the control of hybrid DCCB and the system fault ride‐through strategies are properly designed. PSCAD/EMTDC simulations are shown to demonstrate theoretical analysis.
- 6 December 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (2) , 222-230
Open AccessEnergy dissipation of MMC‐HVDC based onshore wind power integration system with FB‐DBS and DCCB
With the development of high‐voltage direct current (HVDC), modular multilevel converter (MMC) is seeking its application in onshore wind power integration. AC and DC faults are important issues for the wind power integration system, during which the wind generation system continuously provides wind power and the surplus power may cause overvoltage to sub‐modules of MMC. This study focuses on the energy dissipation during AC and DC faults for the overhead‐line MMC‐HVDC system integrating large‐scale wind power. A two‐terminal MMC‐HVDC system with permanent magnet synchronous generator based wind farm is studied. Hybrid DC circuit breakers (DCCBs) are employed to interrupt DC fault current and the method based on measuring the rate of change of DC line voltage is adopted to trip DCCBs. Also a full‐bridge sub‐module based dynamic braking system (FB‐DBS) is implemented at the DC link to absorb the surplus wind power in case of AC or DC faults in the HVDC grid. To ride‐through AC and DC faults without blocking IGBTs, the control of hybrid DCCB and the system fault ride‐through strategies are properly designed. PSCAD/EMTDC simulations are shown to demonstrate theoretical analysis.
- 30 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 4109-4121
A Cascaded Converter Interfacing Long-Distance HVdc and Back-to-Back HVdc Systems
This paper proposes a cascaded converter dedicated to long-distance HVDC infeed and asynchronous back-to-back interconnection of receiving grids. The cascaded converter is consisted of MMCs in series and parallel connection, meeting the high DC voltage and power demand of HVDC system. It realizes hierarchical feeding and asynchronous interconnection of receiving grids, optimizing the multi-infeed short circuit ratio and improving the flexibility of the receiving grids. The topology and operating characteristics of the cascaded converter are introduced in detail. The multi-infeed short-circuits ratio (MISCR) and the maximum power infeed of the cascaded converter based HVDC systems are analyzed. Various feasible operating modes with online switching strategies of the cascaded converter are studied to improve the operational flexibility of the system. The simulation results verify the effectiveness of the control strategy of the HVDC system embedding the cascaded converter. The DC faults clearing strategy and operating modes switching strategies are also validated.
- 30 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 4109-4121
A Cascaded Converter Interfacing Long-Distance HVdc and Back-to-Back HVdc Systems
This paper proposes a cascaded converter dedicated to long-distance HVDC infeed and asynchronous back-to-back interconnection of receiving grids. The cascaded converter is consisted of MMCs in series and parallel connection, meeting the high DC voltage and power demand of HVDC system. It realizes hierarchical feeding and asynchronous interconnection of receiving grids, optimizing the multi-infeed short circuit ratio and improving the flexibility of the receiving grids. The topology and operating characteristics of the cascaded converter are introduced in detail. The multi-infeed short-circuits ratio (MISCR) and the maximum power infeed of the cascaded converter based HVDC systems are analyzed. Various feasible operating modes with online switching strategies of the cascaded converter are studied to improve the operational flexibility of the system. The simulation results verify the effectiveness of the control strategy of the HVDC system embedding the cascaded converter. The DC faults clearing strategy and operating modes switching strategies are also validated.
- Open Access
A 3D Thermal Network Model for Monitoring Imbalanced Thermal Distribution of Press-Pack IGBT Modules in MMC-HVDC Applications
In this paper, the impact of a double-sided press-pack insulated-gate-bipolar-transistor (PP IGBT) cooling structure on its thermal impedance distribution is studied and explored. A matrix thermal impedance network model is built by considering the multi-chip thermal coupling effect for the collector side of the PP IGBT. Moreover, a verification has been made by comparing the proposed matrix thermal network model and the conventional lumped RC network model provided by the manufacturer. It is concluded that the collector side has lower thermal resistance and dissipates about 88% of the heat generated by the IGBT chips inside the module. Then, a modular-multilevel-converter high-voltage-direct-current (MMC-HVDC)-based type test setup composed of the press-pack IGBT stacks is established and the junction temperature is calculated with the proposed thermal model and verified by temperature measurements.
Open AccessA 3D Thermal Network Model for Monitoring Imbalanced Thermal Distribution of Press-Pack IGBT Modules in MMC-HVDC Applications
In this paper, the impact of a double-sided press-pack insulated-gate-bipolar-transistor (PP IGBT) cooling structure on its thermal impedance distribution is studied and explored. A matrix thermal impedance network model is built by considering the multi-chip thermal coupling effect for the collector side of the PP IGBT. Moreover, a verification has been made by comparing the proposed matrix thermal network model and the conventional lumped RC network model provided by the manufacturer. It is concluded that the collector side has lower thermal resistance and dissipates about 88% of the heat generated by the IGBT chips inside the module. Then, a modular-multilevel-converter high-voltage-direct-current (MMC-HVDC)-based type test setup composed of the press-pack IGBT stacks is established and the junction temperature is calculated with the proposed thermal model and verified by temperature measurements.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 334-345
A Transient Voltage-Based DC Fault Line Protection Scheme for MMC-Based DC Grid Embedding DC Breakers
Fast and reliable DC fault detection is one of the main challenges for modular multilevel converter (MMC) based DC grid with DC circuit breakers (DCCBs). This paper extracts the high-frequency components in transient voltages by wavelet transform and proposes a fault identification method based on the difference of square of transient voltages to identify the faulted lines for DC grids using overhead lines. Meanwhile, a faulted pole discrimination method based on the difference between the change of positive and negative pole voltages is presented. A line protection scheme including detection activation, fault identification, faulted pole discrimination and post-fault re-closing is designed. Using only the local measurements, the scheme can realize the protection of the whole line without communication and has the capability of fault resistance endurance and anti-disturbance. The proposed method is tested with a four-terminal MMC based DC grid in PSCAD/EMTDC. The selection methods of threshold values are presented and the impact of DCCB operation on the reliability of DC fault protection is analysed. Simulation results verify the fast detection and reliability of the designed DC line protection scheme.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 334-345
A Transient Voltage-Based DC Fault Line Protection Scheme for MMC-Based DC Grid Embedding DC Breakers
Fast and reliable DC fault detection is one of the main challenges for modular multilevel converter (MMC) based DC grid with DC circuit breakers (DCCBs). This paper extracts the high-frequency components in transient voltages by wavelet transform and proposes a fault identification method based on the difference of square of transient voltages to identify the faulted lines for DC grids using overhead lines. Meanwhile, a faulted pole discrimination method based on the difference between the change of positive and negative pole voltages is presented. A line protection scheme including detection activation, fault identification, faulted pole discrimination and post-fault re-closing is designed. Using only the local measurements, the scheme can realize the protection of the whole line without communication and has the capability of fault resistance endurance and anti-disturbance. The proposed method is tested with a four-terminal MMC based DC grid in PSCAD/EMTDC. The selection methods of threshold values are presented and the impact of DCCB operation on the reliability of DC fault protection is analysed. Simulation results verify the fast detection and reliability of the designed DC line protection scheme.
- 1 September 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 162, 99-108
State-space model and PQ operating zone analysis of hybrid MMC
- 1 September 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 162, 99-108
State-space model and PQ operating zone analysis of hybrid MMC