KAKang An

Kang An

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kang An has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Highly Luminescent Zero-Dimensional (Ph 3 S) 2 HfCl 6 : Sb 3+ Hybrid Crystal Exhibiting Dual-Mode Afterglow for Information Encryption

    by Mengyue Wu, Jun’aN Lai, HengYi Shu, Faguang Kuang, Yue Han, Kang An, Yayun Pu, Baofei Sun, Qingqing Dou, Heng Luo, et al.

    Room-temperature phosphorescent materials have garnered significant attention in the realm of encryption and information encoding due to their unique capability of sustained emitting after the excitation source is removed. However, conventional single-mode encryption techniques often suffer from insufficient security, highlighting the imperative need to develop more robust, multimode encryption agents. In this study, a zero-dimensional organic-inorganic hybrid metal halide crystal, (Ph3S)2HfCl6 ([Ph3S]: triphenyl sulfonium), was successfully synthesized and explored for time-resolved information encryption applications. Through the strategic incorporation of Sb3+ ions into (Ph3S)2HfCl6, an efficient energy transfer pathway was established from the singlet S1 and triplet Tn state, enabling self-trapped excitons (STEs). This doping process significantly enhanced the crystal's photoluminescence quantum yield from 33.5% to a remarkable 71.26%. Furthermore, the (Ph3S)2HfCl6: x%Sb3+ composite exhibited a fascinating combination of afterglow and STE emissions, each with distinct decay characteristics and durations. This unique two-level lifetime property facilitates encryption with higher security, which has been successfully demonstrated for ASCII binary and decimal encoding applications. These findings underscore the substantial potential of (Ph3S)2HfCl6: x%Sb3+ as a sustainable encryption agent, which is capable of facilitating one-time encoding and twice-decoding processes.


  • Molecule design enabled high efficiency flexible zirconium-based lead-free perovskite scintillator

    by Yanru Guo, Baiqian Wang, Xiaoding Zhang, Kang An, Zhigang Zang, Ru Li

    Metal halide perovskites are the most promising candidates in the field of X-ray detection and imaging. However, the self-absorption and toxicity of lead-based perovskites severely limit their widespread application. Herein, zirconium-based halide perovskites have attracted much attention due to their excellent stability, low toxicity, and suitable bandgap, self-free absorption, wide emission spectrum. In this work, (C8H20N)2ZrCl6 single crystals are synthesized by evaporation crystallization, which presents a large Stokes shift of 203 nm, a high PLQY of 80.77%, and good stability over 180 days. Then, the assembled (C8H20N)2ZrCl6@PDMS films show good flexibility (bending and stretching) and a spatial resolution of 5.8 lp/mm. Thus, this work not only provides a route to explore lead-free metal halide perovskites with broadband emission but also demonstrates flexible zirconium-based scintillators for X-ray scintillation imaging.


  • SVB: Self-Supervised Real CT Denoising via Similarity-Based Visual Blind-Spot Scheme

    by Yizhong Wang, Shaoyu Wang, Ailong Cai, Kang An, Ningning Liang, Zhizhong Zheng, Lei Li, Bin Yan

    Low-dose and photon-counting computed tomography (CT) denoising is a challenging task in medical imaging that has attracted significant attention. The supervised deep denoising method has significant effects, but requires a large amount of noisy-clean image pairs, which are often not available in practice. In this paper, we develop a novel self-supervised method via similarity-based visual blind-spot scheme (SVB) for real CT image denoising. Firstly, a suitable paired similar images is constructed by analyzing the characteristics between similar images at different intervals, which relaxes the condition of noise independence between them. Secondly, we introduce the blind-spot scheme into similarity-based self-supervised methods, associating blind-spot denoising with original noisy image denoising to eliminate independent noise and avoid the loss of valuable pixel information. Thirdly, to improve the generalization of the network, we design a denoising network architecture that can estimate unknown noise levels. Experimentally, the SVB method is superior to supervised methods and other self-supervised methods to a large extent, and has excellent denoising performance while ensuring the restoration of intrinsic features.


  • Measuring Size and Stability of Focal Spot for Linear Accelerator in Industrial CT by Slit Translation Scanning Method

    by Fengxiao Li, Guowei Zhong, Haijun Yu, Kang An, Rifeng Zhou

    The size and stability of the X-ray beam focal spot in the electron linear accelerator are crucial factors affecting the spatial resolution of high-energy industrial computed tomography. The commonly used “Sandwich” test method for the X-ray beam focal spot size measurement is complex, vulnerable to human-related factors, and impossible for real-time measurement of stability. In this paper, we devise a slit translation scanning method to measure both size and stability of the X-ray beam focal spot for the electron linear accelerator. Firstly, this paper theoretically analyzed the impact of the effective slit width and sampling frequency on the measurement results. Secondly, a 9 MeV electron linear accelerator was used to measure the X-ray beam focal spot size. The measurement errors along x and y directions are smaller than 5.6% compared to the results measured by the IEC 62976-2017 standard method. Last, The stability of the X-ray beam focal spot was assessed using the slit translation scanning method with three different electron linear accelerators (9 MeV, 6 MeV, and 2 MeV). The results reveal random drift of the X-ray beam focal spot position, with a maximum drift up to 0.6 mm. The experiments demonstrate the simplicity and efficiency of the proposed slit translation scanning method which proves invaluable for the meticulous measurement of the size and stability of the X-ray beam focal spot for electron linear accelerator.


  • Open Access

    White emission metal halides for flexible and transparent x-ray scintillators

    by Shuangyi Zhao, Jinrong Zhao, Saif M. H. Qaid, Dehai Liang, Kang An, Wensi Cai, Qingkai Qian, Zhigang Zang

    Flat-panel x-ray scintillators with a high spatial resolution at a low radiation dose rate are desirable for efficient imaging applications in medical diagnostics, security inspection, and nondestructive inspection. To promote the progress of x-ray imaging technologies, it is of great interest to explore transparent scintillators with reduced light scattering, high light yields, and uniform radioluminescence. Herein, we design and prepare a novel lead-free (C12H28N)2Cu2I4 metal halide featuring a high luminescent efficiency and white emission benefiting from the double self-trapped exciton mechanism, which enable to not only match the response of semiconductor-based sensors but also enhance light yields and decrease exposed doses to objects. Furthermore, transparent, and flexible scintillators with large areas of 20.25 cm2 demonstrate an outstanding scintillation performance including a high spatial resolution of 19.8 lp mm−1 and an ultralow detection limit of 28.39 nGyair s−1, which are ∼4 times higher and 194 times lower than typical values for medical imaging, respectively. This work provides not only a new route to explore promising alternatives with broadband emission but also a novel opportunity to develop flexible x-ray imaging technology.


  • Nonlinear Deviation CorrecTion for Ring-Artifact Removal With Cone-Beam Computed Tomography

    by Xiaodong Guo, Weiwen Wu, Xiaojiao Duan, Haijun Yu, Dingyue Chang, Peng He, Jue Wang, Rifeng Zhou, Yu Du, Kang An

    In practice, cone-beam computed tomography (CT) images are usually tarnished by ring artifacts. To address this problem, in this article, we proposed a ring-artifact removal technique based on the nonlinear deviation correction of pixel response for flat panel detector (FPD), named Nonlinear Deviation CorrecTion (NDCT). Our proposed NDCT is a two-point fitting correction method of the local response from mean projection images. Its advantages lie in the following three aspects. First, it obtains correction coefficients by solving the correction equations based on the mean projection images without additional scanning, which improves efficiency. Second, it corrects all pixels of FPD at the same time, which eliminates the inconsistency of adjacent pixels and then the ring artifact within the 3-D CT image can be corrected. Third, the calculation is very simple so the correction speed is fast, which further improves efficiency in practice. Both numerical and real experiments showed that our NDCT method achieved excellent performance and fast speed in ring-artifact removal.


  • A High-Quality Photon-Counting CT Technique Based on Weight Adaptive Total-Variation and Image-Spectral Tensor Factorization for Small Animals Imaging

    by Weiwen Wu, Dianlin Hu, Kang An, Shaoyu Wang, Fulin Luo

    Photon-counting X-ray computed tomography (CT) has been attracting great attention in tissue characterization, material discrimination, and so on. The emitting X-ray energy spectrum cutting into several energy bins that can result in only a part of X-ray photons can be collected within each narrow bin. This can compromise the image quality. In this case, how to obtain high-quality tomography is a big challenge. In this study, to overcome these issues, we mainly focus on developing an advanced imaging software based on the latest photon-counting CT system (MARS scanner). Specifically, we first design a weight adaptive total variation (TV) using compressed sensing theory. Then, combining the weight adaptive TV and nonlocal low-rank tensor factorization to formulate a new weight adaptive total-variation and image-spectral tensor factorization (WATITF) model for high-quality imaging. Finally, the optimization model is performed to obtain its solution. The studies including the numerical and preclinical mice are performed to validate and evaluate its outperformance.


  • A Novel Micro-Multifocus X-Ray Source Based on Electron Beam Scanning for Multi-View Stationary Micro Computed Tomography

    by Kang An, Yifan Yin, Fukun Li, Limin Shi, Xiaolong Hu, Jie Tang, Rifeng Zhou

    We developed a new prototype micro-multifocus X-ray source based on electron beam scanning (MMFEBS) for multi-view stationary Micro Computed Tomography (multi-view stationary Micro-CT). This micro-multifocus X-ray source includes an electron gun, electron beam deflection coils, a dynamic condensor, a flat panel transmission target and dynamic vacuum system. The electron beam is controlled by the deflection coils and sweeps back and forth on the flat panel transmission target. It hits a series of accurately-defined positions on the target, resulting in two-dimensional X-ray multi-focus array. A dynamic condensor is utilized to overcome the electron beam defocusing caused by the deflection. It guarantees the same high spatial resolution (better than $4 μm) at any deflection angle. The MMFEBS, together with a rotational stage and a flat panel detector, produces a multi-view stationary Micro-CT which can obtain multi-view X-ray projection data for CT images in static condition. Micron resolution CT images obtained in our experiments showed that the MMFEBS has high resolution and good repeatability.