RZRifeng Zhou

Rifeng Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rifeng Zhou has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Focal spot morphology reconstruction and dimensional quantification of microfocus x-ray sources using combined edges rotation method

    by Guowei Zhong, Chengfeng Liu, Fengxiao Li, Qi Wang, Rifeng Zhou

    Micro-computed tomography (micro-CT) is a fundamental technology for detecting micro-defects and characterizing three-dimensional internal structures. It is widely used in advanced semiconductor packaging, new material research, and micro-nano manufacturing. The size and two-dimensional morphology of x-ray focal spots are critical parameters that determine the spatial resolution of micro-CT systems. Existing measurement methods have inherent limitations: they cannot precisely characterize the two-dimensional morphology or quantify the anisotropic morphology of micron-scale focal spots, and they rely heavily on micro-nano precision machining, resulting in limited universality. To address these challenges, this work proposes the combined edges rotation method (CERM). CERM utilizes an orthogonally combined edges structure to overcome the inaccurate rotation center positioning and operational complexity associated with conventional single-edge methods. Supported by a dedicated measurement setup and a comprehensive image processing pipeline—including edge region extraction, angle correction, and back-projection reconstruction—CERM enables high-precision dimensional measurement and two-dimensional morphology reconstruction of microfocus spots. Experimental results demonstrate that CERM accurately characterizes focal spot anisotropy, achieving relative deviations below 5% for approximately 4 μm single-stage focused x-ray sources and below 1.5% for approximately 2 μm two-stage focused x-ray sources at 600× magnification. Unlike traditional methods, CERM eliminates the need for precision micro-nano components (e.g. pinholes, masks), offering superior measurement accuracy, operational simplicity, universality, and simultaneous two-dimensional morphological characterization. This technique provides robust technical support for micro-CT system performance evaluation and x-ray source optimization.

  • Open Access

    Development of a measurement instrument for the X-ray focal spot size and stability of electron linear accelerators

    by Fengxiao Li, Chengfeng Liu, Guowei Zhong, Run Yang, Kang An, Rifeng Zhou

    BackgroundThe dimensions and positional stability of X-ray focal spots produced by electron linear accelerators significantly influence the quality of non-destructive testing (NDT) imaging and are critical determinants of spatial resolution in radiographic imaging. The conventional "sandwich" method recommended by International Electrotechnical Commission (IEC) 62976:2021 standards involves complex procedures and cannot achieve rapid and repetitive measurement of focal spot positional stability.PurposeThis study aims to develop a slit translation scanning method and a dedicated measurement instrument for determining the X-ray focal spot size and stability of electron linear accelerators.MethodsFirstly, a comprehensive hardware system was developed comprising four main components: a stainless steel slit device, a high-energy X-ray detection and acquisition system, a high-precision mechanical scanning system, and a host computer interface. Then, based on slit translation scanning, the measurement principle was established with the slit's stepwise move across the focal spot while X-ray intensity data at each position was recorded to obtain the intensity distribution. Finally, the complete system was experimentally tested on various electron linear accelerators including 2 MeV, 6 MeV, and 9 MeV systems, with comparative validation against the traditional "sandwich" method.ResultsThe experimental results demonstrate that the measurement errors are within 10% compared to the "sandwich" method, with X-direction focal spot size of 1.95 mm versus 1.941 mm by the traditional method (0.5% error) and Y-direction size of 2.26 mm versus 2.139 mm (5.6% error). The instrument enables rapid and repetitive measurements with excellent repeatability and successfully monitors focal spot position variations within 0.1 mm during stability assessments. Individual instances show focal spot displacement reaching up to 0.6 mm, indicating the instrument's capability to detect focal spot instabilities.ConclusionsThe developed measurement instrument in this study provides a fast, repeatable, and accurate method for X-ray focal spot size determination, not only quantifies focal spot dimensions but also enables dynamic monitoring of positional changes, offering significant advantages over traditional methods for enhancing NDT imaging quality assessment.

  • Research on CT image deblurring method based on focal spot intensity distribution

    by Fengxiao Li, Guowei Zhong, Haijun Yu, Rifeng Zhou

  • A variable gaussian kernel scale active contour model based on Jeffreys divergence for ICT image segmentation

    by Zexin Liu, Qi Li, Junyao Wang, Tingyuan Deng, Rifeng Zhou, Yufang Cai, Fenglin Liu

  • Improved Circular Edge Analysis Method for Measuring the Focus Size and Shape in High-Energy Electron Accelerator

    by Fengxiao Li, Guowei Zhong, Haijun Yu, Rifeng Zhou

    To achieve high spatial resolution of X-ray imaging, the focal spot size of high-energy non-destructive testing electron accelerators has been progressively reduced from 2 mm to below 1 mm, and in some cases, down to tens of micrometers. To measure these increasingly smaller focal spots, traditional methods such as the “Sandwich” test method and the slit translation scanning method, are no longer effective. This paper developed an improved circular edge analysis method (ICEAM) for measuring the size and shape of the focal spot of electron accelerators. The ICEAM employs the detector’s point spread function to correct the non-ideal circular aperture image caused by the X-ray scatter and the detector’s cross-talk. Then, edge spread functions of the corrected circular aperture image are used to construct a sinogram of the focal spot, which is subsequently used to reconstruct the intensity distribution image of the focal spot by using the filtered back-projection method. This approach enables precise measurement of both the shape and the size of the focal spot. Theoretical and experimental results demonstrate that ICEAM can not only conveniently and rapidly measure the shape and size of focal spots for conventional high-energy electron accelerators, with measurement errors within 5.8%, but also accurately measure the micrometer-scale focal spots for novel MeV energy electron accelerators (Rhodotron), with measurement errors within 16.2% of the theoretical value. The proposed ICEAM effectively tackles the challenges in measuring the shape and size of the microfocus for novel high-energy electron accelerators, and it is of significant importance for advancing the application of these electron accelerators in digital X-ray imaging and high-end equipment such as industrial CT.


  • Measuring Size and Stability of Focal Spot for Linear Accelerator in Industrial CT by Slit Translation Scanning Method

    by Fengxiao Li, Guowei Zhong, Haijun Yu, Kang An, Rifeng Zhou

    The size and stability of the X-ray beam focal spot in the electron linear accelerator are crucial factors affecting the spatial resolution of high-energy industrial computed tomography. The commonly used “Sandwich” test method for the X-ray beam focal spot size measurement is complex, vulnerable to human-related factors, and impossible for real-time measurement of stability. In this paper, we devise a slit translation scanning method to measure both size and stability of the X-ray beam focal spot for the electron linear accelerator. Firstly, this paper theoretically analyzed the impact of the effective slit width and sampling frequency on the measurement results. Secondly, a 9 MeV electron linear accelerator was used to measure the X-ray beam focal spot size. The measurement errors along x and y directions are smaller than 5.6% compared to the results measured by the IEC 62976-2017 standard method. Last, The stability of the X-ray beam focal spot was assessed using the slit translation scanning method with three different electron linear accelerators (9 MeV, 6 MeV, and 2 MeV). The results reveal random drift of the X-ray beam focal spot position, with a maximum drift up to 0.6 mm. The experiments demonstrate the simplicity and efficiency of the proposed slit translation scanning method which proves invaluable for the meticulous measurement of the size and stability of the X-ray beam focal spot for electron linear accelerator.


  • Nonlinear Deviation CorrecTion for Ring-Artifact Removal With Cone-Beam Computed Tomography

    by Xiaodong Guo, Weiwen Wu, Xiaojiao Duan, Haijun Yu, Dingyue Chang, Peng He, Jue Wang, Rifeng Zhou, Yu Du, Kang An

    In practice, cone-beam computed tomography (CT) images are usually tarnished by ring artifacts. To address this problem, in this article, we proposed a ring-artifact removal technique based on the nonlinear deviation correction of pixel response for flat panel detector (FPD), named Nonlinear Deviation CorrecTion (NDCT). Our proposed NDCT is a two-point fitting correction method of the local response from mean projection images. Its advantages lie in the following three aspects. First, it obtains correction coefficients by solving the correction equations based on the mean projection images without additional scanning, which improves efficiency. Second, it corrects all pixels of FPD at the same time, which eliminates the inconsistency of adjacent pixels and then the ring artifact within the 3-D CT image can be corrected. Third, the calculation is very simple so the correction speed is fast, which further improves efficiency in practice. Both numerical and real experiments showed that our NDCT method achieved excellent performance and fast speed in ring-artifact removal.


  • A Novel Micro-Multifocus X-Ray Source Based on Electron Beam Scanning for Multi-View Stationary Micro Computed Tomography

    by Kang An, Yifan Yin, Fukun Li, Limin Shi, Xiaolong Hu, Jie Tang, Rifeng Zhou

    We developed a new prototype micro-multifocus X-ray source based on electron beam scanning (MMFEBS) for multi-view stationary Micro Computed Tomography (multi-view stationary Micro-CT). This micro-multifocus X-ray source includes an electron gun, electron beam deflection coils, a dynamic condensor, a flat panel transmission target and dynamic vacuum system. The electron beam is controlled by the deflection coils and sweeps back and forth on the flat panel transmission target. It hits a series of accurately-defined positions on the target, resulting in two-dimensional X-ray multi-focus array. A dynamic condensor is utilized to overcome the electron beam defocusing caused by the deflection. It guarantees the same high spatial resolution (better than $4 μm) at any deflection angle. The MMFEBS, together with a rotational stage and a flat panel detector, produces a multi-view stationary Micro-CT which can obtain multi-view X-ray projection data for CT images in static condition. Micron resolution CT images obtained in our experiments showed that the MMFEBS has high resolution and good repeatability.