Zhihong Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhihong Fan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Qiulin Tan
North University of China
4 shared publications - Lei Zhang
Key Laboratory of Micro/Nano Devices and Systems, Ministry of Education, North University of China, Taiyuan 030051, China
3 shared publications - Jijun Xiong
North University of China
2 shared publications Baimao Lin
North University of China, Taiyuan, Shanxi , CHINA
1 shared publication- Baimao Lin
Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China
1 shared publication - Guanyu Liu
Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China
1 shared publication
Latest Publications
- 11 February 2021
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 30 (3) , 035024
Wearable pressure sensor based on MXene/single-wall carbon nanotube film with crumpled structure for broad-range measurements
High-performance flexible pressure sensors are attracting great interest owing to their potential applications for electronic skins, human–machine interfaces, and biomedical diagnostics. However, there remain significant challenges for the fabrication of low-cost and high-sensitivity sensors. Here, we report the preparation of Ti 3 C 2 T x MXene/single-wall carbon nanotube (SWNT) composite films through vacuum-assisted filtration followed by thermal shrinkage. SWNTs can effectively prevent MXenes from stacking and improve the electrical performance of the films. The films are used as a flexible piezoresistive sensor for pressures ranging from 33 Pa to 130 kPa. And experimental test results indicate that the fabricated pressure sensors have high sensitivity (116.15 kPa −1 below 40 kPa and 12.7 kPa −1 at 40–130 kPa), a fast response time of 13 ms, and long-term stability over 6000 periods. The sensor can be used to monitor human physiological signals, such as finger movements, voice detection, and wrist pulse in real-time. Moreover, a 4 × 4 sensor array was successfully applied in the pressure distribution mapping of different objects, indicating that the pressure sensor can be applied in electronic skin, medical devices, and other wearable devices.
- 11 February 2021
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 30 (3) , 035024
Wearable pressure sensor based on MXene/single-wall carbon nanotube film with crumpled structure for broad-range measurements
High-performance flexible pressure sensors are attracting great interest owing to their potential applications for electronic skins, human–machine interfaces, and biomedical diagnostics. However, there remain significant challenges for the fabrication of low-cost and high-sensitivity sensors. Here, we report the preparation of Ti 3 C 2 T x MXene/single-wall carbon nanotube (SWNT) composite films through vacuum-assisted filtration followed by thermal shrinkage. SWNTs can effectively prevent MXenes from stacking and improve the electrical performance of the films. The films are used as a flexible piezoresistive sensor for pressures ranging from 33 Pa to 130 kPa. And experimental test results indicate that the fabricated pressure sensors have high sensitivity (116.15 kPa −1 below 40 kPa and 12.7 kPa −1 at 40–130 kPa), a fast response time of 13 ms, and long-term stability over 6000 periods. The sensor can be used to monitor human physiological signals, such as finger movements, voice detection, and wrist pulse in real-time. Moreover, a 4 × 4 sensor array was successfully applied in the pressure distribution mapping of different objects, indicating that the pressure sensor can be applied in electronic skin, medical devices, and other wearable devices.
- Open Access
- 30 December 2020
- Published by MDPI AG in Micromachines
- Vol. 12 (1) , 34
Wireless Passive LC Temperature and Strain Dual-Parameter Sensor
There is an increasing demand for bearing temperature and strain monitoring in high-speed rotating systems. This study proposes a new multiresonance, multiplexing, wireless, passive inductance capacitance (LC) temperature and strain sensor. The sensor has two capacitors connected at different locations (turns) on the same inductor to achieve simultaneous temperature and strain measurements. The plate capacitor is connected to the inner part of the inductor and the other interdigital capacitor is connected to the outer part of the inductor to form two LC loops. The structure of the sensor is optimized through High Frequency Structure Simulator (HFSS) simulations to realize frequency separation of the two parameters and avoid mutual interference between the two signals. The sensor is fabricated on a polyimide film using electroplating technology. The experimental results show that the temperature–strain sensor can operate stably from 25 °C to 85 °C with an average sensitivity of 27.3 kHz/°C within this temperature range. The sensor can detect strains in the range of 1000–5000 με with a strain sensitivity of 100 Hz/με at 25 °C. Therefore, the proposed wireless passive LC temperature-strain sensor exhibits stable performance. In addition, the use of a single inductor effectively reduces the sensor’s area. The flexible substrate provides advantageous surface conformal attachment characteristics suitable for monitoring high-temperature rotating parts in adverse environments.
- 30 December 2020
- Published by MDPI AG in Micromachines
- Vol. 12 (1) , 34
Open AccessWireless Passive LC Temperature and Strain Dual-Parameter Sensor
There is an increasing demand for bearing temperature and strain monitoring in high-speed rotating systems. This study proposes a new multiresonance, multiplexing, wireless, passive inductance capacitance (LC) temperature and strain sensor. The sensor has two capacitors connected at different locations (turns) on the same inductor to achieve simultaneous temperature and strain measurements. The plate capacitor is connected to the inner part of the inductor and the other interdigital capacitor is connected to the outer part of the inductor to form two LC loops. The structure of the sensor is optimized through High Frequency Structure Simulator (HFSS) simulations to realize frequency separation of the two parameters and avoid mutual interference between the two signals. The sensor is fabricated on a polyimide film using electroplating technology. The experimental results show that the temperature–strain sensor can operate stably from 25 °C to 85 °C with an average sensitivity of 27.3 kHz/°C within this temperature range. The sensor can detect strains in the range of 1000–5000 με with a strain sensitivity of 100 Hz/με at 25 °C. Therefore, the proposed wireless passive LC temperature-strain sensor exhibits stable performance. In addition, the use of a single inductor effectively reduces the sensor’s area. The flexible substrate provides advantageous surface conformal attachment characteristics suitable for monitoring high-temperature rotating parts in adverse environments.
- Open Access
- 20 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 184312-184319
High Performance Amorphous IGZO Thin-Film Transistor Based on Alumina Ceramic
Ceramic materials are high-temperature resistant materials with promising prospects. In some applications, semiconductor devices need to be integrated with a ceramic substrate. Herein, we report on the stable operation of an Al2O3 ceramic-based amorphous-Indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) at room temperature up to 523 K. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were used to characterize the a-IGZO film. A mixed solution was printed on the surface of an insulating layer of alumina. After the combustion reaction, the metal electrode was printed on the surface of a-IGZO to obtain a TFT. The ION/IOFF ratio was 6.04×106 at 293 K, and it was maintained at 1.44×105 at 523 K. It was demonstrated that the parameters of a-IGZO TFTs such as the subthreshold swing (SS), gm and μsat changed at different temperatures. As such, they can be used as building blocks for integrated circuits that can operate at high temperatures. The fabrication of TFT-based inverters, NAND and NOR gate circuits facilitate the exploration of the possibility of more complex digital circuits that operate at high temperatures, based on hybrid circuit design.
- 20 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 184312-184319
Open AccessHigh Performance Amorphous IGZO Thin-Film Transistor Based on Alumina Ceramic
Ceramic materials are high-temperature resistant materials with promising prospects. In some applications, semiconductor devices need to be integrated with a ceramic substrate. Herein, we report on the stable operation of an Al2O3 ceramic-based amorphous-Indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) at room temperature up to 523 K. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were used to characterize the a-IGZO film. A mixed solution was printed on the surface of an insulating layer of alumina. After the combustion reaction, the metal electrode was printed on the surface of a-IGZO to obtain a TFT. The ION/IOFF ratio was 6.04×106 at 293 K, and it was maintained at 1.44×105 at 523 K. It was demonstrated that the parameters of a-IGZO TFTs such as the subthreshold swing (SS), gm and μsat changed at different temperatures. As such, they can be used as building blocks for integrated circuits that can operate at high temperatures. The fabrication of TFT-based inverters, NAND and NOR gate circuits facilitate the exploration of the possibility of more complex digital circuits that operate at high temperatures, based on hybrid circuit design.
- Open Access
An LC Passive Wireless Gas Sensor Based on PANI/CNT Composite
This paper proposes a wireless passive gas sensor based on the principle of LC mutual coupling. After the acidification of the carbon nanotube (CNT), the in-situ polymerization of the aminobenzene monomers was conducted on the surface of the acidified CNT to form a sensitive material composed of a polyaniline/carbon nanotube (PANI/CNT) composite. The Advanced Design System (ADS) software was used for simulating and analyzing the designed structure, which obtained the various parameters of the structure. A lead-free aluminum paste was printed on an alumina ceramic substrate via the screen printing technique to form an inductor coil, before the gas sensitive material was applied to prepare a wireless passive gas sensor, consisting of a single-turn inductor and interdigitated electrodes on the base structure. Finally, an experimental platform was built to test the performance of the sensor. The sensitivity of the gas sensor is about 0.04 MHz/ppm in an atmosphere with a NH3 concentration of 300 ppm. The sensor was shown to have good repeatability and high stability over a long time period.
Open AccessAn LC Passive Wireless Gas Sensor Based on PANI/CNT Composite
This paper proposes a wireless passive gas sensor based on the principle of LC mutual coupling. After the acidification of the carbon nanotube (CNT), the in-situ polymerization of the aminobenzene monomers was conducted on the surface of the acidified CNT to form a sensitive material composed of a polyaniline/carbon nanotube (PANI/CNT) composite. The Advanced Design System (ADS) software was used for simulating and analyzing the designed structure, which obtained the various parameters of the structure. A lead-free aluminum paste was printed on an alumina ceramic substrate via the screen printing technique to form an inductor coil, before the gas sensitive material was applied to prepare a wireless passive gas sensor, consisting of a single-turn inductor and interdigitated electrodes on the base structure. Finally, an experimental platform was built to test the performance of the sensor. The sensitivity of the gas sensor is about 0.04 MHz/ppm in an atmosphere with a NH3 concentration of 300 ppm. The sensor was shown to have good repeatability and high stability over a long time period.