Ellie Nuth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ellie Nuth has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
A. V. S. Hill
Health Protection Agency, Centre for Emergency Preparedness and Response, Porton Down, Salisbury, United Kingdom,1 the Jenner Institute, University of Oxford, Oxford, United Kingdom,2 Colorado State University, Fort Collins, Colorado,3 Churchill Hospital, Headington, Oxford, United Kingdom4
1 shared publicationA. Williams
Health Protection Agency, Centre for Emergency Preparedness and Response, Porton Down, Salisbury, United Kingdom,1 the Jenner Institute, University of Oxford, Oxford, United Kingdom,2 Colorado State University, Fort Collins, Colorado,3 Churchill Hospital, Headington, Oxford, United Kingdom4
1 shared publication- Alice Marriott
Public Health England, Microbiology Services, Porton Down, Salisbury, Wiltshire, United Kingdom
1 shared publication - Andrew D. White
Research and Evaluation, UK Health Security Agency
1 shared publication - Anthony McIntyre
The Churchill Hospital, Headington, Oxford, UK
1 shared publication B. Bawa
Department of Diagnostic Medicine/Pathobiology College of Veterinary Medicine Kansas State University Manhattan USA
1 shared publication
Latest Publications
- 1 July 2015
- Published by Elsevier in Journal of Exotic Pet Medicine
- Vol. 24 (3) , 376-379
Diagnostic Challenge
- 1 July 2015
- Published by Elsevier in Journal of Exotic Pet Medicine
- Vol. 24 (3) , 376-379
Diagnostic Challenge
- 5 November 2014
- Published by Wiley in Equine Veterinary Education
- Vol. 27 (2) , 75-80
Computed tomographic myelography of a foal with discospondylitis and extradural spinal cord compression due to a vertebral abscess
Summary: A one‐month‐old Quarter Horse colt presented with progressive gait abnormalities and weakness. The foal was ataxic at presentation. Radiography identified focal endplate irregularities and lysis at C6 –7. Radiographic diagnosis was discospondylitis. Computed tomographic myelography was performed immediately following euthanasia and identified an extradural compressive spinal cord lesion corresponding to the site of discospondylitis. Post mortem examination findings included abscess formation at the C6 –7 intervertebral space with osteomyelitis extending into the adjacent physes and subchondral bone of caudal C6 and cranial C7 . The vertebral abscess extended into the ventral spinal canal at C6 –7 and was identified as the cause of extradural spinal cord compression. S almonella sp. was cultured and isolated from purulent exudate at the intervertebral space. Computed tomographic myelography has not been previously reported for assessment of discospondylitis in horses and was successful at accurately characterising spinal cord compression in addition to osteolytic changes associated with discospondylitis.
- 5 November 2014
- Published by Wiley in Equine Veterinary Education
- Vol. 27 (2) , 75-80
Computed tomographic myelography of a foal with discospondylitis and extradural spinal cord compression due to a vertebral abscess
Summary: A one‐month‐old Quarter Horse colt presented with progressive gait abnormalities and weakness. The foal was ataxic at presentation. Radiography identified focal endplate irregularities and lysis at C6 –7. Radiographic diagnosis was discospondylitis. Computed tomographic myelography was performed immediately following euthanasia and identified an extradural compressive spinal cord lesion corresponding to the site of discospondylitis. Post mortem examination findings included abscess formation at the C6 –7 intervertebral space with osteomyelitis extending into the adjacent physes and subchondral bone of caudal C6 and cranial C7 . The vertebral abscess extended into the ventral spinal canal at C6 –7 and was identified as the cause of extradural spinal cord compression. S almonella sp. was cultured and isolated from purulent exudate at the intervertebral space. Computed tomographic myelography has not been previously reported for assessment of discospondylitis in horses and was successful at accurately characterising spinal cord compression in addition to osteolytic changes associated with discospondylitis.
- 15 April 2014
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 244 (8) , 961-967
Identification and effects of common errors and artifacts on the perceived quality of radiographs
Objective—To identify common errors in film and digital radiographs provided by referring veterinarians and determine the effect of such errors on the perceived diagnostic quality of image sets. Design—Prospective study. Sample—135 sets of radiographic images acquired by referring veterinarians for client-owned small animals evaluated at a university hospital. Procedures—Sets of radiographs were prospectively collected and evaluated for proper performance of various radiographic technical variables including exposure, collimation, positioning, inclusion of all appropriate views, presence of artifacts, radiation safety, and labeling. Sets of radiographs were subjectively determined to be of diagnostic or nondiagnostic quality by 2 evaluators. Results—The variables exposure, correct positioning, absence of artifacts, and acquisition of all appropriate views were significantly associated with a determination of diagnostic quality for radiograph sets. Correct patient labeling, radiation safety, and x-ray beam centering and collimation were not associated with a determination of diagnostic quality for radiograph sets. The number of categories with errors was significantly associated with identification of radiograph sets as having diagnostic or nondiagnostic quality. Digital radiographs had a significantly lower number of image artifacts and significantly higher frequency of proper labeling versus film radiographs. Conclusions and Clinical Relevance—Results of this study suggested the technical variables proper exposure, proper positioning, absence of artifacts, and acquisition of all appropriate views were important for acquisition of sets of radiographs of high diagnostic quality. Identification of these errors and adjustment of radiographic technique to eliminate such errors would aid veterinarians in obtaining radiographs of high diagnostic quality and may reduce misinterpretation.
- 15 April 2014
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 244 (8) , 961-967
Identification and effects of common errors and artifacts on the perceived quality of radiographs
Objective—To identify common errors in film and digital radiographs provided by referring veterinarians and determine the effect of such errors on the perceived diagnostic quality of image sets. Design—Prospective study. Sample—135 sets of radiographic images acquired by referring veterinarians for client-owned small animals evaluated at a university hospital. Procedures—Sets of radiographs were prospectively collected and evaluated for proper performance of various radiographic technical variables including exposure, collimation, positioning, inclusion of all appropriate views, presence of artifacts, radiation safety, and labeling. Sets of radiographs were subjectively determined to be of diagnostic or nondiagnostic quality by 2 evaluators. Results—The variables exposure, correct positioning, absence of artifacts, and acquisition of all appropriate views were significantly associated with a determination of diagnostic quality for radiograph sets. Correct patient labeling, radiation safety, and x-ray beam centering and collimation were not associated with a determination of diagnostic quality for radiograph sets. The number of categories with errors was significantly associated with identification of radiograph sets as having diagnostic or nondiagnostic quality. Digital radiographs had a significantly lower number of image artifacts and significantly higher frequency of proper labeling versus film radiographs. Conclusions and Clinical Relevance—Results of this study suggested the technical variables proper exposure, proper positioning, absence of artifacts, and acquisition of all appropriate views were important for acquisition of sets of radiographs of high diagnostic quality. Identification of these errors and adjustment of radiographic technique to eliminate such errors would aid veterinarians in obtaining radiographs of high diagnostic quality and may reduce misinterpretation.
- 1 August 2010
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 17 (8) , 1170-1182
Establishment of an Aerosol Challenge Model of Tuberculosis in Rhesus Macaques and an Evaluation of Endpoints for Vaccine Testing
The establishment of an aerosol challenge model in nonhuman primates (NHPs) for the testing of vaccines against Mycobacterium tuberculosis would assist the global effort to optimize novel vaccination strategies. The endpoints used in preclinical challenge studies to identify measures of disease burden need to be accurate and sensitive enough to distinguish subtle differences and benefits afforded by different tuberculosis (TB) vaccine regimens when group sizes are inevitably small. This study sought to assess clinical and nonclinical endpoints as potentially sensitive measures of disease burden in a challenge study with rhesus macaques by using a new protocol of aerosol administration of M. tuberculosis . Immunological and clinical readouts were assessed for utility in vaccine evaluation studies. This is the first example of TB vaccine evaluation with rhesus macaques where long-term survival was one of the primary endpoints. However, we found that in NHP vaccine efficacy studies with maximum group sizes of six animals, survival did not provide a valuable endpoint. Two approaches used in human clinical trials for the evaluation of the gamma interferon (IFN-γ) response to vaccination (enzyme-linked immunospot [ELISpot] assay and enzyme-linked immunosorbent assay [ELISA]) were included in this study. The IFN-γ profiles induced following vaccination were found not to correlate with protection, nor did the level of purified protein derivative (PPD)-specific proliferation. The only readout to reliably distinguish vaccinated and unvaccinated NHPs was the determination of lung lesion burden using magnetic resonance (MR) imaging combined with stereology at the end of the study. Therefore, the currently proposed key markers were not shown to correlate with protection, and only imaging offered a potentially reliable correlate.
- 1 August 2010
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 17 (8) , 1170-1182
Establishment of an Aerosol Challenge Model of Tuberculosis in Rhesus Macaques and an Evaluation of Endpoints for Vaccine Testing
The establishment of an aerosol challenge model in nonhuman primates (NHPs) for the testing of vaccines against Mycobacterium tuberculosis would assist the global effort to optimize novel vaccination strategies. The endpoints used in preclinical challenge studies to identify measures of disease burden need to be accurate and sensitive enough to distinguish subtle differences and benefits afforded by different tuberculosis (TB) vaccine regimens when group sizes are inevitably small. This study sought to assess clinical and nonclinical endpoints as potentially sensitive measures of disease burden in a challenge study with rhesus macaques by using a new protocol of aerosol administration of M. tuberculosis . Immunological and clinical readouts were assessed for utility in vaccine evaluation studies. This is the first example of TB vaccine evaluation with rhesus macaques where long-term survival was one of the primary endpoints. However, we found that in NHP vaccine efficacy studies with maximum group sizes of six animals, survival did not provide a valuable endpoint. Two approaches used in human clinical trials for the evaluation of the gamma interferon (IFN-γ) response to vaccination (enzyme-linked immunospot [ELISpot] assay and enzyme-linked immunosorbent assay [ELISA]) were included in this study. The IFN-γ profiles induced following vaccination were found not to correlate with protection, nor did the level of purified protein derivative (PPD)-specific proliferation. The only readout to reliably distinguish vaccinated and unvaccinated NHPs was the determination of lung lesion burden using magnetic resonance (MR) imaging combined with stereology at the end of the study. Therefore, the currently proposed key markers were not shown to correlate with protection, and only imaging offered a potentially reliable correlate.