Dawid Kaluza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dawid Kaluza has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Agata Michalska
3 shared publicationsKrzysztof Maksymiuk
3 shared publications- Agata Michalska
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
2 shared publications Anna Kisiel
2 shared publicationsGabriele Magna
2 shared publications- Krzysztof Maksymiuk
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
2 shared publications
Latest Publications
- 14 September 2021
- Published by Wiley in Electroanalysis
- Vol. 34 (1) , 25-32
An Electrochemical Approach to Quantification of Volatile Organic Solvents Dispersed in Solution – Towards Bipolar Electrode Sensors
A novel approach to electrochemical determination of volatile organic compounds (VOCs) suspended in a solution is proposed. This approach benefits from properties of capacitors linked in series, where the total capacitance is affected by analyte induced changes. A tailor designed hydrophobic PVDF membrane modified with polyoctylthiophene used in this arrangement played a role of a bipolar electrode. The presence of water immiscible liquid VOCs results in spontaneous formation of a thin film on the surface of the hydrophobic polymer membrane and dissolution of modifying particulates. This effect leads to change of electrical parameters of the system: capacitance and resistance dependent on amount of VOCs present in the aqueous phase.
- 14 September 2021
- Published by Wiley in Electroanalysis
- Vol. 34 (1) , 25-32
An Electrochemical Approach to Quantification of Volatile Organic Solvents Dispersed in Solution – Towards Bipolar Electrode Sensors
A novel approach to electrochemical determination of volatile organic compounds (VOCs) suspended in a solution is proposed. This approach benefits from properties of capacitors linked in series, where the total capacitance is affected by analyte induced changes. A tailor designed hydrophobic PVDF membrane modified with polyoctylthiophene used in this arrangement played a role of a bipolar electrode. The presence of water immiscible liquid VOCs results in spontaneous formation of a thin film on the surface of the hydrophobic polymer membrane and dissolution of modifying particulates. This effect leads to change of electrical parameters of the system: capacitance and resistance dependent on amount of VOCs present in the aqueous phase.
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (61) , 1630
Styrene Detection in Water By Polythiophene Nanoparticles Suspension
Introduction The versatility of fluorescent reporters makes them adaptable to the detection of different chemicals. [1] Most fluorescent systems work in quenching mode, namely the sensor signal consists in a reduction of the emission; less frequent is the case of sensing molecules where the fluorescence is activated by the interaction. Recently, this behavior has been demonstrated in optical fluorescent reporters made of Poly(3-octylthiophene) nanoparticles have been recently reported. [2] In this work we utilized a similar approach to detect styrene in water. Styrene is an aromatic hydrocarbon, used for the preparation of polystyrene, one of the most popular polymers, widely used in many industrial processes. Here we investigated the feasibility of polythiophene, Poly[3-(Ethyl-6-hexanoate)thiophene-2,5-diyl], nanoparticles stabilized in aqueous medium by the presence of poly-vinyl alcohol (PVA). Actually, these nanoparticles are able to sense the presence of styrene by increasing the fluorescence emission. The sensor is enough sensitive to detect the styrene dissolved in water solution from the gaseous phase. Thus, this system can be used to measure not only styrene contamination in water, but also styrene contamination in air. This latter event threats the health of workers in several industrial processes. Saturated styrene vapors were mixed with nitrogen by mass flow controllers and then fluxed over the water solutions, obtaining different concentrations of styrene in the liquid phase (following the Henry’s law). This latter case enables to reach low concentrations in water. Results shows a high sensitivity to styrene. The selectivity has been tested comparing the response to an alcohol (ethanol) and a chlorinated solvent (chloroform). Experimental Synthesis of nanoparticles was performed using typical procedure for polythiophene nanosystems [2]; 100 mL of PT solution in THF (10 mg/ mL) was added to 1 mL 1 % w/w PVA on a stirrer. The THF evaporation within 5 min was resulting in nanoparticle formation. TEM images of PT nanoparticles are reported in Figure 1. Figure 2 shows the characterization setup. Styrene saturated vapors were diluted with nitrogen gas to achieve a desired concentration and fluxed in the headspace of PT suspended in water. Saturated vapor pressures were calculated by Antoine equation, whereas air-water coefficient partition was used to calculated the concentration in water due to the solubilization. Fluorescence changes were recorded by RF-1501 fluorimeter. Results Figure 3 shows the emission spectra of PT nanoparticles in water excited at 490 nm. Styrene in water elicits the increase of emission. A peak at 585 nm in the emission spectra is observed under styrene exposure. At concentrations in air above 40 ppm, a second peak at 620 nm is observed. The intensity at 585 nm is barely linear with the concentration in air (Figure 4). Due to the emergence of the additional peak at 620 nm, the peak at 585 becomes broader, and this behavior affects the linearity of the sensor response. A proper multicomponent analysis of spectral data provides a better estimation of the styrene concentration. The linear fit of Figure 4 returns a sensitivity of about 3 ppm-1 respect to styrene in air. The sensitivity has also been measured respect to an alcohol (ethanol) and a chlorinated solvent (chloroform). Figure 5 shows that sensitivity to styrene is about an order of magnitude larger respect to chloroform and three orders of magnitude respect to ethanol. References Paolesse R, Monti D, Dini F, Di Natale C. Fluorescence based sensor arrays, Topics in Current Chemistry, 2011; 300, 139-174 Woźnica, E., Maksymiuk, K., & Michalska, A. Polyacrylate microspheres for tunable fluorimetric zinc ions sensor. Analytical chemistry 86.1 (2013): 411-418. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (61) , 1630
Styrene Detection in Water By Polythiophene Nanoparticles Suspension
Introduction The versatility of fluorescent reporters makes them adaptable to the detection of different chemicals. [1] Most fluorescent systems work in quenching mode, namely the sensor signal consists in a reduction of the emission; less frequent is the case of sensing molecules where the fluorescence is activated by the interaction. Recently, this behavior has been demonstrated in optical fluorescent reporters made of Poly(3-octylthiophene) nanoparticles have been recently reported. [2] In this work we utilized a similar approach to detect styrene in water. Styrene is an aromatic hydrocarbon, used for the preparation of polystyrene, one of the most popular polymers, widely used in many industrial processes. Here we investigated the feasibility of polythiophene, Poly[3-(Ethyl-6-hexanoate)thiophene-2,5-diyl], nanoparticles stabilized in aqueous medium by the presence of poly-vinyl alcohol (PVA). Actually, these nanoparticles are able to sense the presence of styrene by increasing the fluorescence emission. The sensor is enough sensitive to detect the styrene dissolved in water solution from the gaseous phase. Thus, this system can be used to measure not only styrene contamination in water, but also styrene contamination in air. This latter event threats the health of workers in several industrial processes. Saturated styrene vapors were mixed with nitrogen by mass flow controllers and then fluxed over the water solutions, obtaining different concentrations of styrene in the liquid phase (following the Henry’s law). This latter case enables to reach low concentrations in water. Results shows a high sensitivity to styrene. The selectivity has been tested comparing the response to an alcohol (ethanol) and a chlorinated solvent (chloroform). Experimental Synthesis of nanoparticles was performed using typical procedure for polythiophene nanosystems [2]; 100 mL of PT solution in THF (10 mg/ mL) was added to 1 mL 1 % w/w PVA on a stirrer. The THF evaporation within 5 min was resulting in nanoparticle formation. TEM images of PT nanoparticles are reported in Figure 1. Figure 2 shows the characterization setup. Styrene saturated vapors were diluted with nitrogen gas to achieve a desired concentration and fluxed in the headspace of PT suspended in water. Saturated vapor pressures were calculated by Antoine equation, whereas air-water coefficient partition was used to calculated the concentration in water due to the solubilization. Fluorescence changes were recorded by RF-1501 fluorimeter. Results Figure 3 shows the emission spectra of PT nanoparticles in water excited at 490 nm. Styrene in water elicits the increase of emission. A peak at 585 nm in the emission spectra is observed under styrene exposure. At concentrations in air above 40 ppm, a second peak at 620 nm is observed. The intensity at 585 nm is barely linear with the concentration in air (Figure 4). Due to the emergence of the additional peak at 620 nm, the peak at 585 becomes broader, and this behavior affects the linearity of the sensor response. A proper multicomponent analysis of spectral data provides a better estimation of the styrene concentration. The linear fit of Figure 4 returns a sensitivity of about 3 ppm-1 respect to styrene in air. The sensitivity has also been measured respect to an alcohol (ethanol) and a chlorinated solvent (chloroform). Figure 5 shows that sensitivity to styrene is about an order of magnitude larger respect to chloroform and three orders of magnitude respect to ethanol. References Paolesse R, Monti D, Dini F, Di Natale C. Fluorescence based sensor arrays, Topics in Current Chemistry, 2011; 300, 139-174 Woźnica, E., Maksymiuk, K., & Michalska, A. Polyacrylate microspheres for tunable fluorimetric zinc ions sensor. Analytical chemistry 86.1 (2013): 411-418. Figure 1
- 1 May 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-01 (33) , 2388
Styrene Detection in Water By Polythiophene Nanoparticles Suspension
Introduction The versatility of fluorescent reporters makes them adaptable to the detection of different chemicals. [1] Most fluorescent systems work in quenching mode, namely the sensor signal consists in a reduction of the emission; less frequent is the case of sensing molecules where the fluorescence is activated by the interaction. Recently, this behavior has been demonstrated in optical fluorescent reporters made of Poly(3-octylthiophene) nanoparticles have been recently reported. [2] In this work we utilized a similar approach to detect styrene in water. Styrene is an aromatic hydrocarbon, used for the preparation of polystyrene, one of the most popular polymers, widely used in many industrial processes. Here we investigated the feasibility of Poly[3-(Ethyl-6-hexanoate)thiophene-2,5-diyl], hereinafter referred to as either polythiophene or PT, nanoparticles stabilized in aqueous medium by the presence of poly-vinyl alcohol (PVA). Actually, these nanoparticles are able to sense the presence of styrene by increasing the fluorescence emission. The sensor is enough sensitive to detect the styrene dissolved in water solution from the gaseous phase. Thus, this system can be used to measure not only styrene contamination in water, but also styrene contamination in air. This latter event threats the health of workers in several industrial processes. Saturated styrene vapors were mixed with nitrogen by mass flow controllers and then fluxed over the water solutions, obtaining different concentrations of styrene in the liquid phase (following the Henry’s law). This latter case enables to reach low concentrations in water. Results shows a high sensitivity to styrene. The selectivity has been tested comparing the response to an alcohol (ethanol) and a chlorinated solvent (chloroform). Experimental Synthesis of nanoparticles was performed using typical procedure for polythiophene nanosystems [2]; 100 mL of PT solution in THF (10 mg/ mL) was added to 1 mL 1 % w/w PVA on a stirrer. The THF evaporation within 5 min was resulting in nanoparticle formation. TEM images of PT nanoparticles are reported in Figure 1. Figure 2 shows the characterization setup. Styrene saturated vapors were diluted with nitrogen gas to achieve a desired concentration and fluxed in the headspace of PT suspended in water. Saturated vapor pressures were calculated by Antoine equation, whereas air-water coefficient partition was used to calculated the concentration in water due to the solubilization. Fluorescence changes were recorded by Shimadzu RF-1501 fluorimeter. Results Figure 3 shows the emission spectra of PT nanoparticles in water excited at 490 nm. Styrene in water elicits the increase of emission. A peak at 585 nm in the emission spectra is observed under styrene exposure. At concentrations in air above 40 ppm, a second peak at 620 nm is observed. The intensity at 585 nm is barely linear with the concentration in air (Figure 4). Due to the emergence of the additional peak at 620 nm, the peak at 585 becomes broader, and this behavior affects the linearity of the sensor response. A proper multicomponent analysis of spectral data provides a better estimation of the styrene concentration. The linear fit of Figure 4 returns a sensitivity of about 3 ppm-1 respect to styrene in air. The sensitivity has also been measured respect to an alcohol (ethanol) and a chlorinated solvent (chloroform). Figure 5 shows that sensitivity to styrene is about an order of magnitude larger respect to chloroform and three orders of magnitude respect to ethanol. Acknowledgements. “Financial support from Italy-Poland Canaletto program, project PO19MO08 is gratefully acknowledged.” References 1. R. Paolesse, D. Monti, F. Dini, C. Di Natale, Fluorescence based sensor arrays, Topics in Current Chemistry, 300, 139-174 (2010), doi: 10.1007/128_2010_97 2. E. Woźnica, K. Maksymiuk, A. Michalska, Polyacrylate microspheres for tunable fluorimetric zinc ions sensor, Analytical chemistry 86(1), 411-418 (2013), doi: 10.1021/ac4033142 Figure 1
- 1 May 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-01 (33) , 2388
Styrene Detection in Water By Polythiophene Nanoparticles Suspension
Introduction The versatility of fluorescent reporters makes them adaptable to the detection of different chemicals. [1] Most fluorescent systems work in quenching mode, namely the sensor signal consists in a reduction of the emission; less frequent is the case of sensing molecules where the fluorescence is activated by the interaction. Recently, this behavior has been demonstrated in optical fluorescent reporters made of Poly(3-octylthiophene) nanoparticles have been recently reported. [2] In this work we utilized a similar approach to detect styrene in water. Styrene is an aromatic hydrocarbon, used for the preparation of polystyrene, one of the most popular polymers, widely used in many industrial processes. Here we investigated the feasibility of Poly[3-(Ethyl-6-hexanoate)thiophene-2,5-diyl], hereinafter referred to as either polythiophene or PT, nanoparticles stabilized in aqueous medium by the presence of poly-vinyl alcohol (PVA). Actually, these nanoparticles are able to sense the presence of styrene by increasing the fluorescence emission. The sensor is enough sensitive to detect the styrene dissolved in water solution from the gaseous phase. Thus, this system can be used to measure not only styrene contamination in water, but also styrene contamination in air. This latter event threats the health of workers in several industrial processes. Saturated styrene vapors were mixed with nitrogen by mass flow controllers and then fluxed over the water solutions, obtaining different concentrations of styrene in the liquid phase (following the Henry’s law). This latter case enables to reach low concentrations in water. Results shows a high sensitivity to styrene. The selectivity has been tested comparing the response to an alcohol (ethanol) and a chlorinated solvent (chloroform). Experimental Synthesis of nanoparticles was performed using typical procedure for polythiophene nanosystems [2]; 100 mL of PT solution in THF (10 mg/ mL) was added to 1 mL 1 % w/w PVA on a stirrer. The THF evaporation within 5 min was resulting in nanoparticle formation. TEM images of PT nanoparticles are reported in Figure 1. Figure 2 shows the characterization setup. Styrene saturated vapors were diluted with nitrogen gas to achieve a desired concentration and fluxed in the headspace of PT suspended in water. Saturated vapor pressures were calculated by Antoine equation, whereas air-water coefficient partition was used to calculated the concentration in water due to the solubilization. Fluorescence changes were recorded by Shimadzu RF-1501 fluorimeter. Results Figure 3 shows the emission spectra of PT nanoparticles in water excited at 490 nm. Styrene in water elicits the increase of emission. A peak at 585 nm in the emission spectra is observed under styrene exposure. At concentrations in air above 40 ppm, a second peak at 620 nm is observed. The intensity at 585 nm is barely linear with the concentration in air (Figure 4). Due to the emergence of the additional peak at 620 nm, the peak at 585 becomes broader, and this behavior affects the linearity of the sensor response. A proper multicomponent analysis of spectral data provides a better estimation of the styrene concentration. The linear fit of Figure 4 returns a sensitivity of about 3 ppm-1 respect to styrene in air. The sensitivity has also been measured respect to an alcohol (ethanol) and a chlorinated solvent (chloroform). Figure 5 shows that sensitivity to styrene is about an order of magnitude larger respect to chloroform and three orders of magnitude respect to ethanol. Acknowledgements. “Financial support from Italy-Poland Canaletto program, project PO19MO08 is gratefully acknowledged.” References 1. R. Paolesse, D. Monti, F. Dini, C. Di Natale, Fluorescence based sensor arrays, Topics in Current Chemistry, 300, 139-174 (2010), doi: 10.1007/128_2010_97 2. E. Woźnica, K. Maksymiuk, A. Michalska, Polyacrylate microspheres for tunable fluorimetric zinc ions sensor, Analytical chemistry 86(1), 411-418 (2013), doi: 10.1021/ac4033142 Figure 1
- 3 February 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (8) , 2966-2974
Quantifying plasticizer leakage from ion-selective membranes – a nanosponge approach
The spontaneous process of release of plasticizers from membranes typically used in ion-selective sensors is an effect which limits the lifetime of sensors and comes with a risk of safety hazards.
- 3 February 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (8) , 2966-2974
Quantifying plasticizer leakage from ion-selective membranes – a nanosponge approach
The spontaneous process of release of plasticizers from membranes typically used in ion-selective sensors is an effect which limits the lifetime of sensors and comes with a risk of safety hazards.
- 1 October 2019
- Published by Elsevier in Electrochimica Acta
- Vol. 320
Polypyrrole – Gold nanocomposites. Templateless synthesis and electrochemical properties
- 1 October 2019
- Published by Elsevier in Electrochimica Acta
- Vol. 320
Polypyrrole – Gold nanocomposites. Templateless synthesis and electrochemical properties