Mehdi Langlois
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mehdi Langlois has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Franck Pereira Dos Santos
Observatoire de Paris
3 shared publications - Sébastien Merlet
Observatoire de Paris
3 shared publications A. Trimeche
LNE-SYRTE, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Paris 06, 61 Avenue de l'Observatoire, 75014 Paris, France
2 shared publications- Jamie Vovrosh
University of Birmingham
2 shared publications - Kai Bongs
Midlands Ultracold Atom Research Centre (MUARC), University of Birmingham, Birmingham, UK
2 shared publications - Kevin D. Ridley
University of Birmingham
2 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Conception et réalisation d'un gradiomètre de gravité à atomes froids
Cette thèse porte sur la conception et la réalisation d’une nouvelle expérience d’interféromètre atomique au SYRTE. Elle permettra de réaliser des mesures ultrasensibles du gradient vertical de gravité. Cette expérience fonctionnera à terme en utilisant comme source des atomes ultra-froids, préparés sur une puce à atomes. Elle utilisera comme séparatrices des transitions multiphotoniques, obtenues par diffraction de Bragg d’ordre élevé. Le transport des atomes sera assuré par des réseaux optiques en mouvement. Une première partie du dispositif expérimental a été assemblée et son fonctionnement a été validé en réalisant un interféromètre dual. Cet interféromètre est réalisé sur deux ensembles d’atomes produits successivement à partir de la même source d’atomes froids, et interrogés par une même paire de faisceaux Raman. Une nouvelle méthode d’extraction de la phase différentielle a été démontrée expérimentalement. Elle repose sur l’exploitation des corrélations entre les mesures de phase des interféromètres et une estimation de la phase sismique fournie par la mesure annexe d’un capteur classique.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Conception et réalisation d'un gradiomètre de gravité à atomes froids
Cette thèse porte sur la conception et la réalisation d’une nouvelle expérience d’interféromètre atomique au SYRTE. Elle permettra de réaliser des mesures ultrasensibles du gradient vertical de gravité. Cette expérience fonctionnera à terme en utilisant comme source des atomes ultra-froids, préparés sur une puce à atomes. Elle utilisera comme séparatrices des transitions multiphotoniques, obtenues par diffraction de Bragg d’ordre élevé. Le transport des atomes sera assuré par des réseaux optiques en mouvement. Une première partie du dispositif expérimental a été assemblée et son fonctionnement a été validé en réalisant un interféromètre dual. Cet interféromètre est réalisé sur deux ensembles d’atomes produits successivement à partir de la même source d’atomes froids, et interrogés par une même paire de faisceaux Raman. Une nouvelle méthode d’extraction de la phase différentielle a été démontrée expérimentalement. Elle repose sur l’exploitation des corrélations entre les mesures de phase des interféromètres et une estimation de la phase sismique fournie par la mesure annexe d’un capteur classique.
- Top Cited PapersOpen Access
- 23 February 2022
- Published by Springer Nature in Nature
- Vol. 602 (7898) , 590-594
Quantum sensing for gravity cartography
The sensing of gravity has emerged as a tool in geophysics applications such as engineering and climate research1–3, including the monitoring of temporal variations in aquifers4 and geodesy5. However, it is impractical to use gravity cartography to resolve metre-scale underground features because of the long measurement times needed for the removal of vibrational noise6. Here we overcome this limitation by realizing a practical quantum gravity gradient sensor. Our design suppresses the effects of micro-seismic and laser noise, thermal and magnetic field variations, and instrument tilt. The instrument achieves a statistical uncertainty of 20 E (1 E = 10−9 s−2) and is used to perform a 0.5-metre-spatial-resolution survey across an 8.5-metre-long line, detecting a 2-metre tunnel with a signal-to-noise ratio of 8. Using a Bayesian inference method, we determine the centre to ±0.19 metres horizontally and the centre depth as (1.89 −0.59/+2.3) metres. The removal of vibrational noise enables improvements in instrument performance to directly translate into reduced measurement time in mapping. The sensor parameters are compatible with applications in mapping aquifers and evaluating impacts on the water table7, archaeology8–11, determination of soil properties12 and water content13, and reducing the risk of unforeseen ground conditions in the construction of critical energy, transport and utilities infrastructure14, providing a new window into the underground.
- 23 February 2022
- Published by Springer Nature in Nature
- Vol. 602 (7898) , 590-594
Top Cited PapersOpen AccessQuantum sensing for gravity cartography
The sensing of gravity has emerged as a tool in geophysics applications such as engineering and climate research1–3, including the monitoring of temporal variations in aquifers4 and geodesy5. However, it is impractical to use gravity cartography to resolve metre-scale underground features because of the long measurement times needed for the removal of vibrational noise6. Here we overcome this limitation by realizing a practical quantum gravity gradient sensor. Our design suppresses the effects of micro-seismic and laser noise, thermal and magnetic field variations, and instrument tilt. The instrument achieves a statistical uncertainty of 20 E (1 E = 10−9 s−2) and is used to perform a 0.5-metre-spatial-resolution survey across an 8.5-metre-long line, detecting a 2-metre tunnel with a signal-to-noise ratio of 8. Using a Bayesian inference method, we determine the centre to ±0.19 metres horizontally and the centre depth as (1.89 −0.59/+2.3) metres. The removal of vibrational noise enables improvements in instrument performance to directly translate into reduced measurement time in mapping. The sensor parameters are compatible with applications in mapping aquifers and evaluating impacts on the water table7, archaeology8–11, determination of soil properties12 and water content13, and reducing the risk of unforeseen ground conditions in the construction of critical energy, transport and utilities infrastructure14, providing a new window into the underground.
- Open Access
- 2 December 2021
- Published by Springer Nature in Communications Physics
- Vol. 4 (1) , 1-9
Circulating pulse cavity enhancement as a method for extreme momentum transfer atom interferometry
Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.
- 2 December 2021
- Published by Springer Nature in Communications Physics
- Vol. 4 (1) , 1-9
Open AccessCirculating pulse cavity enhancement as a method for extreme momentum transfer atom interferometry
Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.
- Open Access
- 1 October 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (10) , 105125
Reduction of background scattered light in vacuum systems for cold atoms experiments
Recent advances in the understanding and control of cold atom systems have resulted in devices with extraordinary metrological performance. To further improve the performance in these systems, additional methods of noise reduction are needed. Here, we examine the noise reduction possible from vacuum compatible low reflection coatings in cold atom systems by characterizing a black coating and its compatibility in a Magneto-Optical Trap (MOT). We demonstrate that the commercially available PCO35® coating provides low-reflectivity surfaces that are ultra-high vacuum compatible. The reflective properties of the coating are compared to titanium, a common vacuum chamber material, and the reduction to scattered light is characterized over a range of angles and wavelengths. The outgassing properties of the coating are measured to be less than that of the vacuum system used to test the coating, which is limited to 3 × 10−8 mbar L cm−2 s−1. The coating is applied to a vacuum chamber housing a rubidium prism MOT, and its vacuum compatibility is assessed and compared to an identical non-coated system. Finally, the effect of scattered light reduction in a generalized system is explored theoretically. These results show promise for reducing background light in cold atom experiments via the use of low-reflectivity coatings.
- 1 October 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (10) , 105125
Open AccessReduction of background scattered light in vacuum systems for cold atoms experiments
Recent advances in the understanding and control of cold atom systems have resulted in devices with extraordinary metrological performance. To further improve the performance in these systems, additional methods of noise reduction are needed. Here, we examine the noise reduction possible from vacuum compatible low reflection coatings in cold atom systems by characterizing a black coating and its compatibility in a Magneto-Optical Trap (MOT). We demonstrate that the commercially available PCO35® coating provides low-reflectivity surfaces that are ultra-high vacuum compatible. The reflective properties of the coating are compared to titanium, a common vacuum chamber material, and the reduction to scattered light is characterized over a range of angles and wavelengths. The outgassing properties of the coating are measured to be less than that of the vacuum system used to test the coating, which is limited to 3 × 10−8 mbar L cm−2 s−1. The coating is applied to a vacuum chamber housing a rubidium prism MOT, and its vacuum compatibility is assessed and compared to an identical non-coated system. Finally, the effect of scattered light reduction in a generalized system is explored theoretically. These results show promise for reducing background light in cold atom experiments via the use of low-reflectivity coatings.
- 20 November 2017
- Published by American Physical Society (APS) in Physical Review A
- Vol. 96 (5) , 053624
Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors
We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.
- 20 November 2017
- Published by American Physical Society (APS) in Physical Review A
- Vol. 96 (5) , 053624
Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors
We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
CLEO®/Europe-EQEC 2017 active control of laser wavefronts in atom interferometers
Wavefront aberrations are today the main contribution in the inaccuracy budget of best cold atom interferometers [1, 2], based on laser beam splitters, and constitute an important limit for their long-term stability [1]. They prevent from exploiting the full potential of these atom interferometers. In this work, we report on the active control of laser wavefronts for atom interferometry and demonstrate in a proof-of-principle experiment the compensation of their aberrations using, for the first time, a deformable mirror in a cold atom inertial sensor.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
CLEO®/Europe-EQEC 2017 active control of laser wavefronts in atom interferometers
Wavefront aberrations are today the main contribution in the inaccuracy budget of best cold atom interferometers [1, 2], based on laser beam splitters, and constitute an important limit for their long-term stability [1]. They prevent from exploiting the full potential of these atom interferometers. In this work, we report on the active control of laser wavefronts for atom interferometry and demonstrate in a proof-of-principle experiment the compensation of their aberrations using, for the first time, a deformable mirror in a cold atom inertial sensor.
- 23 March 2017
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 7 (3) , 034016
Active Control of Laser Wavefronts in Atom Interferometers
Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of the best cold-atom interferometers based on two-photon laser beam splitters and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in future experiments based on large-momentum beam splitters. In this article, we tackle this issue by using a deformable mirror to control actively the laser wavefronts in atom interferometry. In particular, we demonstrate in an experimental proof of principle the efficient correction of wavefront aberrations in an atomic gravimeter.
- 23 March 2017
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 7 (3) , 034016
Active Control of Laser Wavefronts in Atom Interferometers
Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of the best cold-atom interferometers based on two-photon laser beam splitters and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in future experiments based on large-momentum beam splitters. In this article, we tackle this issue by using a deformable mirror to control actively the laser wavefronts in atom interferometry. In particular, we demonstrate in an experimental proof of principle the efficient correction of wavefront aberrations in an atomic gravimeter.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23271914,p. 456-461
Compact clocks for industrial applications: The EMRP project IND 55 MClocks
Vapor cell atomic clocks are an interesting technology because they combine compactness, low power consumption and excellent relative frequency stability. Recently, due to better performing laser sources and innovative techniques to prepare and detect the atoms, several cell-based prototypes exhibiting unprecedented frequency stability have been developed. These techniques allow a reduction in the transfer of laser noise to the atoms, improvement of the signal-to-noise ratio and subsequently the clock's frequency stability. The project IND55 Mclocks funded by the European Metrological Research Programme (EMRP) proposes to develop high performances vapor cell clocks for industrial applications. Three technologies are investigated: 1) the pulsed optical pumping (POP) scheme; 2) the cold atoms approach, and 3) the Coherent Population Trapping (CPT). The results related to the first period of activity are presented.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23271914,p. 456-461
Compact clocks for industrial applications: The EMRP project IND 55 MClocks
Vapor cell atomic clocks are an interesting technology because they combine compactness, low power consumption and excellent relative frequency stability. Recently, due to better performing laser sources and innovative techniques to prepare and detect the atoms, several cell-based prototypes exhibiting unprecedented frequency stability have been developed. These techniques allow a reduction in the transfer of laser noise to the atoms, improvement of the signal-to-noise ratio and subsequently the clock's frequency stability. The project IND55 Mclocks funded by the European Metrological Research Programme (EMRP) proposes to develop high performances vapor cell clocks for industrial applications. Three technologies are investigated: 1) the pulsed optical pumping (POP) scheme; 2) the cold atoms approach, and 3) the Coherent Population Trapping (CPT). The results related to the first period of activity are presented.