YLYu-Hui Lin

Yu-Hui Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu-Hui Lin has a total of 132 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dynamic range extension of the Tibet underground muon detectors for measurements up to the knee energy region with 3-inch photomultipliers

    by Y.H. Lin, J. Huang, D. Chen, M. Ohnishi, Y. Zhang, L.M. Zhai, X. Chen, J.H. Fang, Y. Meng

    Aiming to study the primary cosmic-ray mass composition up to the knee energy region with the Tibet underground water-Cherenkov muon-detector array (MD), we propose to extend the dynamic range of each MD detector with an 8-inch PMT (Beijing Hamamatsu CR365) and a 3-inch PMT (HZC XP72B22). We carried out a series of tests on the candidate 3-inch XP72B22 PMT to examine whether it can meet our requirements. The measurement results showed that the XP72B22 has a wide dynamic range of 3 orders of magnitude and a linear response up to ∼105 photoelectrons (PEs) at the supply voltage of 700 V. Combined with previous test results of the CR365, these two types of PMT can achieve an equivalent dynamic range from 30 to 106 PEs. As a result, an MD cell is able to detect cosmic rays around the knee energies by adding the CR365 and the XP72B22.

  • Potential PeVatron supernova remnant G106.3+2.7 seen in the highest-energy gamma rays

    by The Tibet ASγ Collaboration, M. Amenomori, Y. W. Bao, X. J. Bi, D. Chen, T. L. Chen, W. Y. Chen, Xu Chen, Y. Chen, Cirennima, et al.


  • Open Access

    Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array

    by Y. Zhang, J. Huang, D. Chen, L.-M. Zhai, X. Chen, X.-B. Hu, Y.-H. Lin, H.-B. Jin, X.-Y. Zhang, C.-F. Feng, et al.

    Since 2014, a new hybrid experiment consisting of a high-energy air-shower-core array (YAC-II), a high-density air-shower array (Tibet-III) and a large underground water-Cherenkov muon-detector array (MD) has been continued by the Tibet ASγ collaboration to measure the chemical composition of cosmic rays in the wide energy range including the ``knee''. In this experiment, YAC-II is used to select high energy core events induced by cosmic rays in the above energy region, while MD is used to estimate the type of nucleus of primary particles by measuring the number of muons contained in the air showers. However, the dynamic range of each MD cell is only 5 to 2000 photoelectrons (PEs) which is mainly designed for observation of high-energy celestial gamma rays. In order to obtain the primary proton, helium and iron spectra and their ``knee'' positions with energy up to 1016 eV, each of PMTs equipped to the MD cell is required to measure the number of photons capable of covering a wide dynamic range of 100–106 PEs according to Monte Carlo simulations. In this paper, we firstly compare the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu. If there exists no serious difference, we will then add two 8-inch-in-diameter PMTs to meet our requirements in each MD cell, which are responsible for the range of 100–10000 PEs and 2000–1000000 PEs, respectively. That is, MD cell is expected to be able to measure the number of muons over 6 orders of magnitudes.


  • Development of Yangbajing air shower core detector for a new EAS hybrid experiment

    by Jin-Sheng Liu, Jing Huang, Ding Chen, Ying Zhang, Liu-Ming Zhai, Xu Chen, Xiao-Bin Hu, Yu-Hui Lin, Xue-Yao Zhang, Cun-Feng Feng, et al.

    Aiming at the observation of cosmic-ray chemical composition in the "knee" energy region, we have been developing a new type of air-shower core detector (YAC, Yangbajing Air shower Core detector array) to be set up at Yangbajing (90.522° E, 30.102° N, 4300 m above sea level, atmospheric depth: 606 g/m2) in Tibet, China. YAC works together with the Tibet air-shower array (Tibet-III) and an underground water Cherenkov muon detector array (MD) as a hybrid experiment. Each YAC detector unit consists of lead plates of 3.5 cm thickness and a scintillation counter which detects the burst size induced by high energy particles in the air-shower cores. The burst size can be measured from 1 MIP (Minimum Ionization Particle) to 106 MIPs. The first phase of this experiment, named "YAC- I", consists of 16 YAC detectors each with a size of 40 cm×50 cm and distributed in a grid with an effective area of 10 m2. YAC- I is used to check hadronic interaction models. The second phase of the experiment, called "YAC- II", consists of 124 YAC detectors with coverage of about 500 m2. The inner 100 detectors of 80 cm×50 cm each are deployed in a 10×10 matrix with a 1.9 m separation; the outer 24 detectors of 100 cm×50 cm each are distributed around these to reject non-core events whose shower cores are far from the YAC- II array. YAC- II is used to study the primary cosmic-ray composition, in particular, to obtain the energy spectra of protons, helium and iron nuclei between 5×1013 eV and 1016 eV, covering the "knee" and also connected with direct observations at energies around 100 TeV. We present the design and performance of YAC- II in this paper.


  • Open Access

    Sensitivity of YAC to measure the light-component spectrum of primary cosmic rays at the ‘knee’ energies

    by L M Zhai, J Huang, D Chen, M Shibata, Y Katayose, Ying Zhang, J S Liu, Xu Chen, X B Hu, Y H Lin