XCXu Chen

Xu Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xu Chen has a total of 169 co-authors. Here are the top co-authors by number of shared publications:

  • Ying Zhang

    Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China

    7 shared publications
  • D. Chen

    National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012, China

    5 shared publications
  • J. Huang

    Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China

    5 shared publications
  • Jing Huang

    State Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China

    5 shared publications
  • Danzengluobu

    4 shared publications
  • Yu-Hui Lin

    Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China

    4 shared publications

Latest Publications

  • Robust frequency-upconversion lasing operated at 400 K from inorganic perovskites microcavity

    by Zhifeng Shi, Fei Zhang, Jingjing Yan, Yuan Zhang, Xu Chen, Shu Chen, Di Wu, Xinjian Li, Yu Zhang, Chongxin Shan

    Multi-photon-pumped lasing based on metal-halide perovskites is promising for nonlinear optics and practical frequency-upconversion devices in integrated photonic systems. However, at present almost all the multi-photon-pumped lasing emissions from perovskite microcavities were limited for two-photon excitation, and also suffered from a compromise in room temperature or low temperature operation conditions. In this study, based on the vapor-phase epitaxial CsPbBr3 microplatelets with high crystallinity, self-formed high-quality microcavities, and great thermal stability, low-threshold and high-quality factor whispering gallery mode lasing was realized under single-, two-, and three-photon excitation, and the lasing action is very stable under continuous pulsed laser irradiation (∼ 3.6 × 107 laser shots). More importantly, the three-photon-pumped lasing can be efficiently sustained at a high temperature of ∼ 400 K, and the characteristic temperature was determined to be as high as ∼ 152.6 K, indicating the highly temperature-insensitive gain threshold. Note that this is the first report on high-temperature three-photon-pumped lasing on perovskite microcavities. Moreover, an aggressive thermal cycling test (two cycles, 290-400-290 K) was further performed to indicate the stability and repeatability of the multi-photon-pumped lasing characteristics. It can be anticipated that the results obtained represent a significant step toward the temperature-insensitive frequency-upconversion lasing, inspiring the exploitation of advantageous perovskites for novel applications.


  • Potential PeVatron supernova remnant G106.3+2.7 seen in the highest-energy gamma rays

    by The Tibet ASγ Collaboration, M. Amenomori, Y. W. Bao, X. J. Bi, D. Chen, T. L. Chen, W. Y. Chen, Xu Chen, Y. Chen, Cirennima, et al.


  • First Detection of Photons with Energy beyond 100 TeV from an Astrophysical Source

    by M. Amenomori, Y. W. Bao, X. J. Bi, D. Chen, T. L. Chen, W. Y. Chen, Xu Chen, Y. Chen, Cirennima, S. W. Cui, et al.

    We report on the highest energy photons from the Crab Nebula observed by the Tibet air shower array with the underground water-Cherenkov-type muon detector array. Based on the criterion of a muon number measured in an air shower, we successfully suppress 99.92% of the cosmic-ray background events with energies E>100  TeV. As a result, we observed 24 photonlike events with E>100  TeV against 5.5 background events, which corresponds to a 5.6σ statistical significance. This is the first detection of photons with E>100  TeV from an astrophysical source.


  • Open Access

    A Northern Sky Survey for 100TeV $\gamma$-ray Sources Using the Tibet Air Shower Array and Muon Detector Array.

    by Xu Chen, on beahlf of the Tibet AS$\gamma$ Collaboration

    The Tibet ASγ experiment located at 4300 m above sea level, Tibet, China, has a wide field of view and large effective area. It consists of the Tibet air-shower array (Tibet-AS), the air-shower core-detector array (YAC) and the underground water-Cherenkov muon-detector array (Tibet- MD). The Tibet-MD array significantly improves its gamma-ray sensitivity in the 10-1000 TeV energy region by an order of magnitude better than any other previous existing experiments in the world. In this paper we will search the γ-ray sources using data taken from 2014. The result shows the direction to the Crab has the most excess in the number of candidate primary γ rays from 3 TeV to 500 TeV. This is the first detection of the highest energy photons beyond 100 TeV from an astrophysical source, and thus opens up the sub-PeV window in astronomy.

  • Open Access

    Study of the sharp "knee" phenomenon of cosmic ray spectrum by using newly upgraded Tibet ASγ experiment

    by Ying Zhang, J. Huang, D. Chen, L.M. Zhai, Xu Chen, Yu-Hui Lin, Jian-Hua Fang, Yoshiaki Nakamura

    Cosmic Ray (CR) spectrum in a certain energy region can not be expressed by a simple power-law as it has a structure. The all-particle energy spectrum of primary CRs observed in a wide range from 10^14 eV to 10^17 eV with the Tibet-III AS array clearly shows a ‘sharp knee’ at around 4 PeV. Based on the hardening structure of energy spectrum observed by AMS-02, CREAM and the (proton+helium) spectrum at 50 – 1000 TeV energy region observed by (YAC-I+Tibet-III), we will discuss the origin of ‘shap knee’ whether it is caused by nearby source or nonlinear acceleration.

  • Open Access

    Towards a better estimation of energy and species of primary cosmic rays in the knee region with the Tibet hybrid experiment: Utilization of refined EAS lateral distributions

    by Ying Zhang, J. Huang, D. Chen, L. M. Zhai, Xu Chen, Y.-H. Lin, Jian-Hua Fang, Yoshiaki Nakamura

    A new hybrid experiment (YAC-II+Tibet-III+MD) located at Yangbajing has started to improve the capability of explicit measurements of the cosmic-ray components (P, He, CNO, Fe, etc) at the knee energy region since 2014. Considering the different features of air shower development for different primary cosmic-ray nuclei, using a full Monte Carlo simulation, we modified the lateral distribution functions for proton-induced, helium-induced and iron-induced air showers, respectively. The results show that the air shower size of different nuclei obtained by the modified Nishimura-Kamata-Greisen function is consistent with the true shower size within 5% systematic errors. Furthermore, we studied the Extensive Air Shower age parameter determination from the lateral distribution functions of charged particles near the air shower core with the Tibet hybrid experiment. The derived age parameter can be well used to estimate the particle type of the incident primary cosmic rays.


  • Open Access

    Test results of new CR365-PMTs for the Tibet muon-detector array

    by Ying Zhang, J. Huang, D Chen, L M Zhai, Xu Chen, Xiao-Bin Hu, Yu-Hui Lin, Hong-Bo Jin, Katsuaki Kasahara

    The Tibet-ASgamma experiment has a water-Cherenkov muon-detector array (MD) as a part of 3 different arrays with specific purposes. To increase the ability of getting the primary proton, helium and iron spectra up to 10^16 eV and clarifing their spectral "knee" positions, we need to upgrade current PMT capabiltty in each MD cell. The current dynamic range of the PMTs is 5 to 2000 photoelectrons (PEs) which is enough for the purpose of observation of high-energy celestial gamma rays. However, according to Monte-Carlo simulations, we need a dynamic range of 100 - 10^6 PEs for the knee problem. For this end, we have a plan of adding two 8-inch-in-diameter PMTs in each MD cell. We have compared the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu, and found that CR365-PMT fulfill our requirements. In this paper, test results of the first batch of 20 CR365-PMTs made by Beijing Hamamatsu for the MD array are shown.

  • Open Access

    Simulation study of proton-induced and iron-induced extensive air shower at the knee energies using the new Tibet experiment

    by Liuming Zhai, D Chen, J. Huang, Ying Zhang, Xu Chen, Katsuaki Kasahara

  • Open Access

    Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array

    by Y. Zhang, J. Huang, D. Chen, L.-M. Zhai, X. Chen, X.-B. Hu, Y.-H. Lin, H.-B. Jin, X.-Y. Zhang, C.-F. Feng, et al.

    Since 2014, a new hybrid experiment consisting of a high-energy air-shower-core array (YAC-II), a high-density air-shower array (Tibet-III) and a large underground water-Cherenkov muon-detector array (MD) has been continued by the Tibet ASγ collaboration to measure the chemical composition of cosmic rays in the wide energy range including the ``knee''. In this experiment, YAC-II is used to select high energy core events induced by cosmic rays in the above energy region, while MD is used to estimate the type of nucleus of primary particles by measuring the number of muons contained in the air showers. However, the dynamic range of each MD cell is only 5 to 2000 photoelectrons (PEs) which is mainly designed for observation of high-energy celestial gamma rays. In order to obtain the primary proton, helium and iron spectra and their ``knee'' positions with energy up to 1016 eV, each of PMTs equipped to the MD cell is required to measure the number of photons capable of covering a wide dynamic range of 100–106 PEs according to Monte Carlo simulations. In this paper, we firstly compare the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu. If there exists no serious difference, we will then add two 8-inch-in-diameter PMTs to meet our requirements in each MD cell, which are responsible for the range of 100–10000 PEs and 2000–1000000 PEs, respectively. That is, MD cell is expected to be able to measure the number of muons over 6 orders of magnitudes.


  • Development of Yangbajing air shower core detector for a new EAS hybrid experiment

    by Jin-Sheng Liu, Jing Huang, Ding Chen, Ying Zhang, Liu-Ming Zhai, Xu Chen, Xiao-Bin Hu, Yu-Hui Lin, Xue-Yao Zhang, Cun-Feng Feng, et al.

    Aiming at the observation of cosmic-ray chemical composition in the "knee" energy region, we have been developing a new type of air-shower core detector (YAC, Yangbajing Air shower Core detector array) to be set up at Yangbajing (90.522° E, 30.102° N, 4300 m above sea level, atmospheric depth: 606 g/m2) in Tibet, China. YAC works together with the Tibet air-shower array (Tibet-III) and an underground water Cherenkov muon detector array (MD) as a hybrid experiment. Each YAC detector unit consists of lead plates of 3.5 cm thickness and a scintillation counter which detects the burst size induced by high energy particles in the air-shower cores. The burst size can be measured from 1 MIP (Minimum Ionization Particle) to 106 MIPs. The first phase of this experiment, named "YAC- I", consists of 16 YAC detectors each with a size of 40 cm×50 cm and distributed in a grid with an effective area of 10 m2. YAC- I is used to check hadronic interaction models. The second phase of the experiment, called "YAC- II", consists of 124 YAC detectors with coverage of about 500 m2. The inner 100 detectors of 80 cm×50 cm each are deployed in a 10×10 matrix with a 1.9 m separation; the outer 24 detectors of 100 cm×50 cm each are distributed around these to reject non-core events whose shower cores are far from the YAC- II array. YAC- II is used to study the primary cosmic-ray composition, in particular, to obtain the energy spectra of protons, helium and iron nuclei between 5×1013 eV and 1016 eV, covering the "knee" and also connected with direct observations at energies around 100 TeV. We present the design and performance of YAC- II in this paper.