Diego Paul Chacon-Troya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Diego Paul Chacon-Troya has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Flavio Quizhpi
Universidad Politécnica Salesiana
2 shared publications - Ricardo David Medina
Instituto de Energa Elctrica Universidad Nacional de San Juan San Juan - Argentina
2 shared publications - Andrea García-Cedeño
Universidad Politécnica Salesiana
1 shared publication - Andrea L. Mogrovejo-Macias
Universidad Politécnica Salesiana
1 shared publication Bryan G. Salvatierra
Universidad Politécnica Salesiana, Ecuador
1 shared publicationC.A. Farfan
Universidad Politécnica Salesiana Sede Cuenca, Ecuador
1 shared publication
Latest Publications
- 30 October 2026
- Published by Salesian Polytechnic University of Ecuador
- p. 65-76
Design and implementation of fire alarm monitoring system for Universidad Politécnica Salesiana, Cuenca Campus
Fire alarm systems are essential in buildings to ensure early detection of various disasters, safeguarding occupants’ safety and protecting infrastructure, minimizing economic losses. In this context, a fire alarm system, also referred to as FAS, is defined as an integrated system that detects unwanted fires by monitoring environmental changes associated with combustion, such as smoke or heat (Jee et al. 2012). This study proposes the implementation of a fire alarm monitoring system within the Salesian Polytechnic University, Cuenca Campus. As a higher education institution, it is imperative to ensure staff safety and protection of infrastructure. The development was based on the design and implementation standards outlined in NFPA 72, the “National Fire Alarm and Signaling Code.” This code provides the latest safety provisions to meet the evolving demands of fire detection, signaling, and emergency communication in society (NFPA JLA, 2023).
- 30 October 2026
- Published by Salesian Polytechnic University of Ecuador
- p. 65-76
Design and implementation of fire alarm monitoring system for Universidad Politécnica Salesiana, Cuenca Campus
Fire alarm systems are essential in buildings to ensure early detection of various disasters, safeguarding occupants’ safety and protecting infrastructure, minimizing economic losses. In this context, a fire alarm system, also referred to as FAS, is defined as an integrated system that detects unwanted fires by monitoring environmental changes associated with combustion, such as smoke or heat (Jee et al. 2012). This study proposes the implementation of a fire alarm monitoring system within the Salesian Polytechnic University, Cuenca Campus. As a higher education institution, it is imperative to ensure staff safety and protection of infrastructure. The development was based on the design and implementation standards outlined in NFPA 72, the “National Fire Alarm and Signaling Code.” This code provides the latest safety provisions to meet the evolving demands of fire detection, signaling, and emergency communication in society (NFPA JLA, 2023).
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Undimotor Generation Analysis in Galápagos (San Cristobal Island) [Not available in English]
The following article deals with the analysis of wave generation in Galápagos, specifically in San Cristóbal Island, since this is the second island with more inhabitants in Galápagos and according to ElecGalápagos it is the island where more thermal generation is used to cover the electrical demand of the island, that is why the study of the energetic potential of the seas of this island will be carried out and it will be analyzed if it is feasible the implementation of this technology that would benefit all the island's habitat. The most feasible way of extracting this energy will be analyzed to then convert it into electrical energy and be able to supply it, then calculate the energy that could be produced by the wave generator and what would be the nominal power that could inject a wave park into the Galápagos electricity network, it will be concluded with an analysis on the environmental impact that the implementation of a wave park would cause.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Undimotor Generation Analysis in Galápagos (San Cristobal Island) [Not available in English]
The following article deals with the analysis of wave generation in Galápagos, specifically in San Cristóbal Island, since this is the second island with more inhabitants in Galápagos and according to ElecGalápagos it is the island where more thermal generation is used to cover the electrical demand of the island, that is why the study of the energetic potential of the seas of this island will be carried out and it will be analyzed if it is feasible the implementation of this technology that would benefit all the island's habitat. The most feasible way of extracting this energy will be analyzed to then convert it into electrical energy and be able to supply it, then calculate the energy that could be produced by the wave generator and what would be the nominal power that could inject a wave park into the Galápagos electricity network, it will be concluded with an analysis on the environmental impact that the implementation of a wave park would cause.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Design and Implementation of an Intelligent Cane, with Proximity Sensors, GPS Localization and GSM Feedback
This paper describes the process of implementing an electronic system for the detection of different types of obstacles in a white cane, focused on improving the daily mobilization of people with visual disabilities. The system consists of an ultrasonic sensor implemented on a stepper motor, in order to detect possible obstacles, with a working range between 0.5 m and 5 m in distance and between 90° left and 90°right in detection, also, a sound module and a buzzer will be implemented in the handle of the cane, in order to alert the disabled person in an efficient way about possible obstacles that may occur around them. An Android application was also designed; the mobile application communicates with the White cane through a GPS and GSM module, to help locate the visually disabled person, in the place where he is, sending the Parameter of longitude and latitude, all in a text message, so that a relative can access to the application and visualizes through Google Maps the exact location of the disabled person that owns the smart cane.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Design and Implementation of an Intelligent Cane, with Proximity Sensors, GPS Localization and GSM Feedback
This paper describes the process of implementing an electronic system for the detection of different types of obstacles in a white cane, focused on improving the daily mobilization of people with visual disabilities. The system consists of an ultrasonic sensor implemented on a stepper motor, in order to detect possible obstacles, with a working range between 0.5 m and 5 m in distance and between 90° left and 90°right in detection, also, a sound module and a buzzer will be implemented in the handle of the cane, in order to alert the disabled person in an efficient way about possible obstacles that may occur around them. An Android application was also designed; the mobile application communicates with the White cane through a GPS and GSM module, to help locate the visually disabled person, in the place where he is, sending the Parameter of longitude and latitude, all in a text message, so that a relative can access to the application and visualizes through Google Maps the exact location of the disabled person that owns the smart cane.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Assessing Consequences of the Final Failure of a Power Transformer Using Fuzzy Logic and Expert Criteria
This document presents an innovative tool for assessing the consequence of the final failure a power transformer, this metric considers aspects as: power quality, overload of other equipment, safety, reliability of the system and the environmental & social impact. For this evaluation, existing standards as well experience and industry practices are integrated. For this regard, a fuzzy inference system was proposed, the membership functions and the rules for integrating each input are based on a survey applied over a set of Ecuadorian power transformers; this study considers technical, economic and social characteristics of the impact of the final failure. The resulting membership functions, and the rules are presented.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Assessing Consequences of the Final Failure of a Power Transformer Using Fuzzy Logic and Expert Criteria
This document presents an innovative tool for assessing the consequence of the final failure a power transformer, this metric considers aspects as: power quality, overload of other equipment, safety, reliability of the system and the environmental & social impact. For this evaluation, existing standards as well experience and industry practices are integrated. For this regard, a fuzzy inference system was proposed, the membership functions and the rules for integrating each input are based on a survey applied over a set of Ecuadorian power transformers; this study considers technical, economic and social characteristics of the impact of the final failure. The resulting membership functions, and the rules are presented.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Domotic application for the monitoring and control of residential electrical loads
In this paper is explained the design of a smart home application for the control and monitoring of residential electrical loads. For this we will make a hybrid application that is the union of a web application and a native application. In the monitoring of this application will be observed the voltage, energy consumed, power and the time in which the measurement was made, also allow us to verify the consumption in dollars of energy. The control will allow us to turn on and off the circuit of luminaires, outlets and special circuits. The application will have an energy limit system, where the administrator of the application can set a monthly limit of energy that wants to consume. The application will allow you to observe a graph of the power and the energy consumed. The final device consists mainly of a Raspberry Pi 2 model B, a resistive touch screen, an arduino nano. The Raspberry Pi will controled the circuits and the arduino nano will realize the acquisition of voltage and current and the calculation of power and energy consumed.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Domotic application for the monitoring and control of residential electrical loads
In this paper is explained the design of a smart home application for the control and monitoring of residential electrical loads. For this we will make a hybrid application that is the union of a web application and a native application. In the monitoring of this application will be observed the voltage, energy consumed, power and the time in which the measurement was made, also allow us to verify the consumption in dollars of energy. The control will allow us to turn on and off the circuit of luminaires, outlets and special circuits. The application will have an energy limit system, where the administrator of the application can set a monthly limit of energy that wants to consume. The application will allow you to observe a graph of the power and the energy consumed. The final device consists mainly of a Raspberry Pi 2 model B, a resistive touch screen, an arduino nano. The Raspberry Pi will controled the circuits and the arduino nano will realize the acquisition of voltage and current and the calculation of power and energy consumed.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Measurement of internal partial discharges in dielectric oils by applying the electrical method
This document details of the conventional electric method for measuring partial discharges (DP) based on the norm IEC 60156, various test were performed on dielectric oils which had different qualities, the test results were processed through MATLAB's signal processing filters in conjunction with fast Fourier transform (FFT) in order to determine the type of partial discharge based on the quality of the dielectric oil and it's contamination level.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Measurement of internal partial discharges in dielectric oils by applying the electrical method
This document details of the conventional electric method for measuring partial discharges (DP) based on the norm IEC 60156, various test were performed on dielectric oils which had different qualities, the test results were processed through MATLAB's signal processing filters in conjunction with fast Fourier transform (FFT) in order to determine the type of partial discharge based on the quality of the dielectric oil and it's contamination level.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Development and implementation of a smart induction stove
Taking into account the recent development in smart phone technology, silicon power electronics controller's ICs, single chip solutions which come at low cost, a novelty smart induction stove is developed using new innovative technologies for interconnectivity and remote command and supervision. The implementation is done by a simple and robust communication protocol to connect an android device to a popular single chip solution Wi-Fi module. Including at the core of the implementation a powerful android application to improve the users experience.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Development and implementation of a smart induction stove
Taking into account the recent development in smart phone technology, silicon power electronics controller's ICs, single chip solutions which come at low cost, a novelty smart induction stove is developed using new innovative technologies for interconnectivity and remote command and supervision. The implementation is done by a simple and robust communication protocol to connect an android device to a popular single chip solution Wi-Fi module. Including at the core of the implementation a powerful android application to improve the users experience.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Simulation of harmonics produced by electroliners in the electrical network of Cuenca City
This article presents the simulation and harmonic analysis of a charging station model developed in “Modeling and protection of electric vehicle charging station”, which was adapted with the electrical parameters of the distribution system of Cuenca city, with The purpose of quantifying the amount of harmonics that this type of stations can produce in the network. The simulation resulted, that the fifth harmonic located at 300 Hz is the most critical in both the voltage and the current. The harmonics produced in the voltage are 15, 74% that are above the limits established in the IEEE 519-2014 standard and the Ecuadorian regulation No. CONELEC-004/01, the harmonics produced in the current are of the order of 1.54% that is within the parameters of the IEEE 519-2014 standard. The results of this research can be used to mitigate the impact and can be used by designers and builders of charging stations and for energy distribution companies.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Simulation of harmonics produced by electroliners in the electrical network of Cuenca City
This article presents the simulation and harmonic analysis of a charging station model developed in “Modeling and protection of electric vehicle charging station”, which was adapted with the electrical parameters of the distribution system of Cuenca city, with The purpose of quantifying the amount of harmonics that this type of stations can produce in the network. The simulation resulted, that the fifth harmonic located at 300 Hz is the most critical in both the voltage and the current. The harmonics produced in the voltage are 15, 74% that are above the limits established in the IEEE 519-2014 standard and the Ecuadorian regulation No. CONELEC-004/01, the harmonics produced in the current are of the order of 1.54% that is within the parameters of the IEEE 519-2014 standard. The results of this research can be used to mitigate the impact and can be used by designers and builders of charging stations and for energy distribution companies.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Improved tool for power transformer health index analysis
This paper analyses the influence of common test in power transformers health index assessing. To achieve this objective a test based sensibility analysis is proposed. To show results, a study case is proposed, using a set of real scenarios analyzes the variation of the output (health index) when each input (oil tests) are varied.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Improved tool for power transformer health index analysis
This paper analyses the influence of common test in power transformers health index assessing. To achieve this objective a test based sensibility analysis is proposed. To show results, a study case is proposed, using a set of real scenarios analyzes the variation of the output (health index) when each input (oil tests) are varied.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 109-112
Health index assessment for power transformers with thermal upgraded paper up to 230kV, using fuzzy inference. Part II: A sensibility analysis
This paper presents a sensitivity analysis of a health index of power transformers tool, in order to identify the importance of each input to determine most important and those that can be dismissed to simplify the calculation process without significantly affecting the effectiveness of answers. To achieve objective, a methodology based on a study case is proposed which, starting from a set of real scenarios, analyzes the variation of the output (health index) when each input (tests performed in oil) is varied.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 109-112
Health index assessment for power transformers with thermal upgraded paper up to 230kV, using fuzzy inference. Part II: A sensibility analysis
This paper presents a sensitivity analysis of a health index of power transformers tool, in order to identify the importance of each input to determine most important and those that can be dismissed to simplify the calculation process without significantly affecting the effectiveness of answers. To achieve objective, a methodology based on a study case is proposed which, starting from a set of real scenarios, analyzes the variation of the output (health index) when each input (tests performed in oil) is varied.