Muhammad W. Rashid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Muhammad W. Rashid has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Annajirao Garimella
Klipsch School of Electrical and Computer Engineering, New Mexico State University, Las Cruces, 88003, USA
4 shared publicationsCoskun Tekes
G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
4 shared publicationsF. Levent Degertekin
School of Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta, USA
4 shared publicationsMaysam Ghovanloo
School of Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta, USA
4 shared publicationsPaul M. Furth
Klipsch School of Electrical and Computer Engineering, New Mexico State University, Las Cruces, 88003, USA
4 shared publicationsGokce Gurun
Georgia Institute of Technology (United States)
3 shared publications
Latest Publications
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Front-end electronics for cable reduction in Intracardiac Echocardiography (ICE) catheters
3-D imaging ICE catheters with large element counts present design challenges in achieving simultaneous data readout from all elements while significantly reducing cable count for a small catheter diameter. Current approaches such as microbeamformer techniques tend to rely on area and power hungry circuits, making them undesirable for ICE catheters. In this paper, a system which uses are an efficient real-time programmable on-chip transmit (TX) beamformer circuitry to reduce the cable count on the TX side and analog 8∶1 Time Division Multiplexing (TDM) with Direct Digital Demodulation (DDD) to reduce the cable count on the receive (RX) side is presented.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Front-end electronics for cable reduction in Intracardiac Echocardiography (ICE) catheters
3-D imaging ICE catheters with large element counts present design challenges in achieving simultaneous data readout from all elements while significantly reducing cable count for a small catheter diameter. Current approaches such as microbeamformer techniques tend to rely on area and power hungry circuits, making them undesirable for ICE catheters. In this paper, a system which uses are an efficient real-time programmable on-chip transmit (TX) beamformer circuitry to reduce the cable count on the TX side and analog 8∶1 Time Division Multiplexing (TDM) with Direct Digital Demodulation (DDD) to reduce the cable count on the receive (RX) side is presented.
- Open Access
- 21 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 63 (8) , 1078-1085
Direct Digital Demultiplexing of Analog TDM Signals for Cable Reduction in Ultrasound Imaging Catheters
In real-time catheter-based 3-D ultrasound imaging applications, gathering data from the transducer arrays is difficult, as there is a restriction on cable count due to the diameter of the catheter. Although area and power hungry multiplexing circuits integrated at the catheter tip are used in some applications, these are unsuitable for use in small sized catheters for applications, such as intracardiac imaging. Furthermore, the length requirement for catheters and limited power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper, an alternative approach using analog time-division multiplexing (TDM) is presented, which addresses the cable restrictions of ultrasound catheters. A novel digital demultiplexing technique is also described, which allows for a reduction in the number of analog signal processing stages required. The TDM and digital demultiplexing schemes are demonstrated for an intracardiac imaging system that would operate in the 4- to 11-MHz range. A TDM integrated circuit (IC) with an 8:1 multiplexer is interfaced with a fast analog-to-digital converter (ADC) through a microcoaxial catheter cable bundle, and processed with a field-programmable gate array register-transfer level simulation. Input signals to the TDM IC are recovered with -40-dB crosstalk between the channels on the same microcoax, showing the feasibility of this system for ultrasound imaging applications.
- 21 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 63 (8) , 1078-1085
Open AccessDirect Digital Demultiplexing of Analog TDM Signals for Cable Reduction in Ultrasound Imaging Catheters
In real-time catheter-based 3-D ultrasound imaging applications, gathering data from the transducer arrays is difficult, as there is a restriction on cable count due to the diameter of the catheter. Although area and power hungry multiplexing circuits integrated at the catheter tip are used in some applications, these are unsuitable for use in small sized catheters for applications, such as intracardiac imaging. Furthermore, the length requirement for catheters and limited power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper, an alternative approach using analog time-division multiplexing (TDM) is presented, which addresses the cable restrictions of ultrasound catheters. A novel digital demultiplexing technique is also described, which allows for a reduction in the number of analog signal processing stages required. The TDM and digital demultiplexing schemes are demonstrated for an intracardiac imaging system that would operate in the 4- to 11-MHz range. A TDM integrated circuit (IC) with an 8:1 multiplexer is interfaced with a fast analog-to-digital converter (ADC) through a microcoaxial catheter cable bundle, and processed with a field-programmable gate array register-transfer level simulation. Input signals to the TDM IC are recovered with -40-dB crosstalk between the channels on the same microcoax, showing the feasibility of this system for ultrasound imaging applications.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Time-division multiplexing for cable reduction in ultrasound imaging catheters
In ultrasound imaging catheter applications, gathering the data from multi-element transducer arrays is difficult as there is a restriction on cable count due to the diameter of the catheter. In such applications, CMUT-on-CMOS technology allows for 2D arrays with many elements to be designed and bonded directly onto CMOS circuitry. This allows for complex electronics to be placed at the tip of the catheter which leads to the possibility to include electronic multiplexing techniques to greatly reduce the cable count required for a large element array. Current approaches to cable reduction tend to rely on area and power hungry circuits to function, making them unsuitable for use in catheters. Furthermore the length requirement for catheters and lack of power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper an alternative approach using Analogue Time Division Multiplexing (TDM) is presented, which addresses the cable restrictions of the catheter and, using a novel digital demultiplexing technique, allows for a reduction in the number of analogue signal processing stages required.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Time-division multiplexing for cable reduction in ultrasound imaging catheters
In ultrasound imaging catheter applications, gathering the data from multi-element transducer arrays is difficult as there is a restriction on cable count due to the diameter of the catheter. In such applications, CMUT-on-CMOS technology allows for 2D arrays with many elements to be designed and bonded directly onto CMOS circuitry. This allows for complex electronics to be placed at the tip of the catheter which leads to the possibility to include electronic multiplexing techniques to greatly reduce the cable count required for a large element array. Current approaches to cable reduction tend to rely on area and power hungry circuits to function, making them unsuitable for use in catheters. Furthermore the length requirement for catheters and lack of power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper an alternative approach using Analogue Time Division Multiplexing (TDM) is presented, which addresses the cable restrictions of the catheter and, using a novel digital demultiplexing technique, allows for a reduction in the number of analogue signal processing stages required.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1540-1543
Design of frequency-division multiplexing front-end receiver electronics for CMUT-on-CMOS based intracardiac echocardiography
Designing Intracardiac Echocardiography (ICE) imaging catheters using 2D arrays with large number of elements is extremely challenging with standard interconnect and transducer technology. Using microbeamformers inside the catheter reduces the number of cables; however it requires complex front-end electronics which consumes considerable amount of real estate. By using the CMUT-on-CMOS technology, one can incorporate on-chip transmit electronics and efficiently optimize the 2D transducer array to use less number of active elements to reduce the number of cables by combining multiple channels on a single output cable. Reducing the number of cables with integrated electronics may provide a flexible catheter which can be used for 3D ICE imaging under MRI as well as X-Ray. In this study, we explore the design of the CMOS receiver circuit which implements a Frequency Division Multiplexing (FDM) scheme to achieve reduced number of output channels. We discuss design details of an 8×1 multiplexing chip designed in 0.35μm CMOS process. We also present post layout simulation results from the chip showing the viability of the approach.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1540-1543
Design of frequency-division multiplexing front-end receiver electronics for CMUT-on-CMOS based intracardiac echocardiography
Designing Intracardiac Echocardiography (ICE) imaging catheters using 2D arrays with large number of elements is extremely challenging with standard interconnect and transducer technology. Using microbeamformers inside the catheter reduces the number of cables; however it requires complex front-end electronics which consumes considerable amount of real estate. By using the CMUT-on-CMOS technology, one can incorporate on-chip transmit electronics and efficiently optimize the 2D transducer array to use less number of active elements to reduce the number of cables by combining multiple channels on a single output cable. Reducing the number of cables with integrated electronics may provide a flexible catheter which can be used for 3D ICE imaging under MRI as well as X-Ray. In this study, we explore the design of the CMOS receiver circuit which implements a Frequency Division Multiplexing (FDM) scheme to achieve reduced number of output channels. We discuss design details of an 8×1 multiplexing chip designed in 0.35μm CMOS process. We also present post layout simulation results from the chip showing the viability of the approach.
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8675, 86750B-86750B-6
CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8675, 86750B-86750B-6
CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1-4
3-D real-time volumetric imaging using 20 MHz 1.5-mm diameter single-chip CMUT-on-CMOS array
An intravascular ultrasound (IVUS) catheter that can provide forward-viewing volumetric ultrasound images would be an invaluable clinical tool for guiding interventions in coronary arteries for treatment of chronic total occlusions (CTOs) and for helping stent deployment. Single-chip integration of front-end electronics with CMUTs is highly desirable for reduced interconnect complexity, miniaturization, and flexibility of IVUS catheters. For this purpose we use the monolithic CMUT-onCMOS integration where CMUTs are fabricated directly on top of pre-processed CMOS wafers. We have previously demonstrated the characterization and imaging performance of monolithically integrated single-chip CMUT-on-CMOS Forward looking IVUS array. Here, we present 3-D real-time volumetric imaging results on vessel mimicking and relevant biological phantoms. The fabricated single chip CMUT-on-CMOS device has 56 transmit and 48 receive array elements operating at 20 MHz with a fractional bandwidth of 50%. The imaging results demonstrate that the single-chip forward looking IVUS (FLIVUS) system with monolithically integrated electronics has potential to visualize the front view of coronary arteries.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1-4
3-D real-time volumetric imaging using 20 MHz 1.5-mm diameter single-chip CMUT-on-CMOS array
An intravascular ultrasound (IVUS) catheter that can provide forward-viewing volumetric ultrasound images would be an invaluable clinical tool for guiding interventions in coronary arteries for treatment of chronic total occlusions (CTOs) and for helping stent deployment. Single-chip integration of front-end electronics with CMUTs is highly desirable for reduced interconnect complexity, miniaturization, and flexibility of IVUS catheters. For this purpose we use the monolithic CMUT-onCMOS integration where CMUTs are fabricated directly on top of pre-processed CMOS wafers. We have previously demonstrated the characterization and imaging performance of monolithically integrated single-chip CMUT-on-CMOS Forward looking IVUS array. Here, we present 3-D real-time volumetric imaging results on vessel mimicking and relevant biological phantoms. The fabricated single chip CMUT-on-CMOS device has 56 transmit and 48 receive array elements operating at 20 MHz with a fractional bandwidth of 50%. The imaging results demonstrate that the single-chip forward looking IVUS (FLIVUS) system with monolithically integrated electronics has potential to visualize the front view of coronary arteries.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1127-1130
Experimental study of dual-ring CMUT array optimization for forward-looking IVUS
Forward-looking (FL) catheters have guiding and volumetric imaging capacities which are highly desirable for IVUS applications. Large channel and firing counts have to be reduced to enable 3-D real-time imaging and simplify front-end electronics. Recently, we have proposed an optimization procedure for dual ring FL arrays which is based on finding an optimal coarray set using the simulated annealing algorithm. The presented algorithm is based on finding a predefined number of optimal firing set which results in elimination of redundant spatial frequencies in the coarray. In this study, we present the experimental demonstration of the proposed method with fabricated single chip CMUT on CMOS system based FL dual ring arrays. The dual ring CMUT arrays were monolithically fabricated on top of CMOS chips which have 25-V pulsers and low-noise transimpedance amplifiers for each transmit and receive array elements. The fabricated CMUT arrays have 56 transmit and 48 receive elements operating at 12 MHz with a 1.4 mm outer diameter. To test the imaging performance of the optimal reduced set, we obtained a 512-element coarray set from the full 2688-element set. In the experiment, we used a phantom of 100-μm aluminium wires immersed in oil tank. We have reconstructed both 2-D PSFs and B-scan images of wire targets. Experimental results demonstrate that the simulated annealing based optimal firing set achieves acceptable lateral and contrast resolution performances with 1/5 of the full set.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1127-1130
Experimental study of dual-ring CMUT array optimization for forward-looking IVUS
Forward-looking (FL) catheters have guiding and volumetric imaging capacities which are highly desirable for IVUS applications. Large channel and firing counts have to be reduced to enable 3-D real-time imaging and simplify front-end electronics. Recently, we have proposed an optimization procedure for dual ring FL arrays which is based on finding an optimal coarray set using the simulated annealing algorithm. The presented algorithm is based on finding a predefined number of optimal firing set which results in elimination of redundant spatial frequencies in the coarray. In this study, we present the experimental demonstration of the proposed method with fabricated single chip CMUT on CMOS system based FL dual ring arrays. The dual ring CMUT arrays were monolithically fabricated on top of CMOS chips which have 25-V pulsers and low-noise transimpedance amplifiers for each transmit and receive array elements. The fabricated CMUT arrays have 56 transmit and 48 receive elements operating at 12 MHz with a 1.4 mm outer diameter. To test the imaging performance of the optimal reduced set, we obtained a 512-element coarray set from the full 2688-element set. In the experiment, we used a phantom of 100-μm aluminium wires immersed in oil tank. We have reconstructed both 2-D PSFs and B-scan images of wire targets. Experimental results demonstrate that the simulated annealing based optimal firing set achieves acceptable lateral and contrast resolution performances with 1/5 of the full set.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Nested Miller compensation using current buffers for multi-stage amplifiers
Firstly, a literature review of existing nested Miller compensation (NMC) schemes for low-voltage multi-stage amplifiers is made. Secondly, a novel nested Miller compensation using two current buffers (NMCCB) in the feedback network is introduced. As opposed to previous NMC schemes, this scheme uses a non-inverting gain stage for the first stage and inverting gain stages for both the second and third stages. An inverting current buffer is utilized for the first time whereas previous NMC feedback networks utilized a positive current buffer. In conventional NMC, the major limitation is bandwidth since inner compensation capacitance loads the output node. In the proposed scheme, the two current buffers in the feedback network create two LHP zeros, cancelling one of the non-dominant poles and extending the bandwidth. Detailed small-signal modeling and analysis of the NMCCB compensation network is presented, demonstrating the effectiveness of this strategy.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Nested Miller compensation using current buffers for multi-stage amplifiers
Firstly, a literature review of existing nested Miller compensation (NMC) schemes for low-voltage multi-stage amplifiers is made. Secondly, a novel nested Miller compensation using two current buffers (NMCCB) in the feedback network is introduced. As opposed to previous NMC schemes, this scheme uses a non-inverting gain stage for the first stage and inverting gain stages for both the second and third stages. An inverting current buffer is utilized for the first time whereas previous NMC feedback networks utilized a positive current buffer. In conventional NMC, the major limitation is bandwidth since inner compensation capacitance loads the output node. In the proposed scheme, the two current buffers in the feedback network create two LHP zeros, cancelling one of the non-dominant poles and extending the bandwidth. Detailed small-signal modeling and analysis of the NMCCB compensation network is presented, demonstrating the effectiveness of this strategy.
- 13 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 11 (6) , 1516-1521
Integrated CMOS Sensor Array for Optical Heterodyne Phase Sensing
A heterodyne interferometric CMOS 8 × 8 phase sensor array was developed to measure the spatial phase distribution of an optical wavefront. This sensor is suitable for measuring rapidly changing surface profiles and characterizing fast turbulence. Using an acousto-optic modulation frequency of 80 MHz and beat frequency of 10 kHz, the system calculates 8-bit phase data at each location in the array at a rate equal to the beat frequency. The phase computation is performed locally, digitized, and stored in 8-bit SRAM. Implemented in a 0.5-μm 2P3M CMOS process, the measured RMS phase error is 1.49 ° (1 LSB) and mismatch has σ = 4.76 ° (3.4 LSB). Experimental results, in agreement with theory, validate the proposed approach.
- 13 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 11 (6) , 1516-1521
Integrated CMOS Sensor Array for Optical Heterodyne Phase Sensing
A heterodyne interferometric CMOS 8 × 8 phase sensor array was developed to measure the spatial phase distribution of an optical wavefront. This sensor is suitable for measuring rapidly changing surface profiles and characterizing fast turbulence. Using an acousto-optic modulation frequency of 80 MHz and beat frequency of 10 kHz, the system calculates 8-bit phase data at each location in the array at a rate equal to the beat frequency. The phase computation is performed locally, digitized, and stored in 8-bit SRAM. Implemented in a 0.5-μm 2P3M CMOS process, the measured RMS phase error is 1.49 ° (1 LSB) and mismatch has σ = 4.76 ° (3.4 LSB). Experimental results, in agreement with theory, validate the proposed approach.
- 10 June 2010
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 46 (12) , 820-822
Adaptive biasing technique to convert pseudo-class AB amplifier to class AB
An essential modification to a conventional four-stage pseudo class AB amplifier results in a true class AB amplifier. As opposed to the conventional pseudo class AB scheme, which uses a current mirror in the third stage, this work uses an adaptive biasing circuit in the third stage to drastically reduce quiescent current. The pseudo class AB and new class AB amplifiers are designed in a 0.5 µm process with power supplies of ±1.5 V for a phase margin of 67° while driving a load of 32 Ω ‖ 500 pF. At a maximum negative load current of −12.5 mA, simulations show that both amplifiers consume 43.9 µA of quiescent current. However, at a maximum positive load current of +12.5 mA, the pseudo class AB consumes 1.22 mA of quiescent current, while the new class AB amplifier consumes only 140 µA: a reduction in quiescent current by more than a factor of eight at maximum positive load.
- 10 June 2010
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 46 (12) , 820-822
Adaptive biasing technique to convert pseudo-class AB amplifier to class AB
An essential modification to a conventional four-stage pseudo class AB amplifier results in a true class AB amplifier. As opposed to the conventional pseudo class AB scheme, which uses a current mirror in the third stage, this work uses an adaptive biasing circuit in the third stage to drastically reduce quiescent current. The pseudo class AB and new class AB amplifiers are designed in a 0.5 µm process with power supplies of ±1.5 V for a phase margin of 67° while driving a load of 32 Ω ‖ 500 pF. At a maximum negative load current of −12.5 mA, simulations show that both amplifiers consume 43.9 µA of quiescent current. However, at a maximum positive load current of +12.5 mA, the pseudo class AB consumes 1.22 mA of quiescent current, while the new class AB amplifier consumes only 140 µA: a reduction in quiescent current by more than a factor of eight at maximum positive load.