Kazuya Takahata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuya Takahata has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Toshiyuki Mito
National Institute for Fusion Science, Toki, Gifu, Japan
18 shared publications - Shinsaku Imagawa
National Institute for Fusion Science, Toki, Japan
15 shared publications - Hitoshi Tamura
National Institute for Fusion Science, Toki, Japan
8 shared publications - Nagato Yanagi
National Institute for Fusion Science
6 shared publications - Akifumi Iwamoto
National Institute for Fusion Science, Toki, Gifu, Japan
3 shared publications - Norikiyo Koizumi
QST Naka, Ibaraki, Japan
3 shared publications
Latest Publications
- Open Access
- 1 June 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1559 (1) , 012118
Novel HTS coil protection method using secondary windings as a quench heater
In NIFS, research and development of HTS magnets have been begun aiming at the application to a next experimental device of Large Helical Device which is a heliotron-type fusion plasma experimental device. The next experimental device needs large coil current density such as 80 A/mm2, therefore it is important to develop a coil protection method. In this study, we have proposed a novel coil protection technology of HTS magnets using secondary windings. By embedding secondary windings which are electrically isolated in a part of the conductor and using the secondary windings as a quench heater, the occurrence of normal conduction is quickly diffused, then prevented local temperature rise in the HTS coil. We applied this method to the conductor and coil under development, and analysed the thermal behaviour of the secondary windings. As a result, we found that the temperature rise of the entire coil can be suppressed and the hotspot region can be diffused. This shows the applicability of coil protection by using the secondary windings, therefore optimal coil protection is possible by changing the ratio of magnetic stored energy between internal consumption and external recovery depending on the value of external resistance.
- 1 June 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1559 (1) , 012118
Open AccessNovel HTS coil protection method using secondary windings as a quench heater
In NIFS, research and development of HTS magnets have been begun aiming at the application to a next experimental device of Large Helical Device which is a heliotron-type fusion plasma experimental device. The next experimental device needs large coil current density such as 80 A/mm2, therefore it is important to develop a coil protection method. In this study, we have proposed a novel coil protection technology of HTS magnets using secondary windings. By embedding secondary windings which are electrically isolated in a part of the conductor and using the secondary windings as a quench heater, the occurrence of normal conduction is quickly diffused, then prevented local temperature rise in the HTS coil. We applied this method to the conductor and coil under development, and analysed the thermal behaviour of the secondary windings. As a result, we found that the temperature rise of the entire coil can be suppressed and the hotspot region can be diffused. This shows the applicability of coil protection by using the secondary windings, therefore optimal coil protection is possible by changing the ratio of magnetic stored energy between internal consumption and external recovery depending on the value of external resistance.
- Open Access
- 1 March 2020
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 4 (3) , 035009
Development of FAIR conductor and HTS coil for fusion experimental device
This study is aimed at the development of high-temperature superconducting (HTS) magnets for application in a fusion experimental device next to the Large Helical Device (LHD). By applying the features of an HTS, high current density and high stability can be balanced. As a candidate conductor, REBCO tapes and pure aluminum sheets are laminated and placed in the groove of an aluminum alloy jacket with a circular cross-section, after joining a lid to the jacket using friction stir welding, and twisting the conductor to homogenize its electrical and mechanical properties. The FAIR conductor derives its name from the processes and materials used in its development: Friction stir welding, an Aluminum alloy jacket, Indirect cooling, and REBCO tapes. Initially, the degradation of the critical current of the FAIR conductor is observed, which was eventually resolved. The development status of the FAIR conductor has been reported.
- 1 March 2020
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 4 (3) , 035009
Open AccessDevelopment of FAIR conductor and HTS coil for fusion experimental device
This study is aimed at the development of high-temperature superconducting (HTS) magnets for application in a fusion experimental device next to the Large Helical Device (LHD). By applying the features of an HTS, high current density and high stability can be balanced. As a candidate conductor, REBCO tapes and pure aluminum sheets are laminated and placed in the groove of an aluminum alloy jacket with a circular cross-section, after joining a lid to the jacket using friction stir welding, and twisting the conductor to homogenize its electrical and mechanical properties. The FAIR conductor derives its name from the processes and materials used in its development: Friction stir welding, an Aluminum alloy jacket, Indirect cooling, and REBCO tapes. Initially, the degradation of the critical current of the FAIR conductor is observed, which was eventually resolved. The development status of the FAIR conductor has been reported.
- Open Access
- 1 April 2018
- Published by Elsevier in Cryogenics
- Vol. 91, 1-6
Lessons learned from twenty-year operation of the Large Helical Device poloidal coils made from cable-in-conduit conductors
- 1 April 2018
- Published by Elsevier in Cryogenics
- Vol. 91, 1-6
Open AccessLessons learned from twenty-year operation of the Large Helical Device poloidal coils made from cable-in-conduit conductors
- Open Access
- 18 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (3) , 1-5
Multiscale Stress Analysis and 3D Fitting Structure of Superconducting Coils for the Helical Fusion Reactor
Conceptual design studies for the Large-Helical-Device-type helical reactor, i.e., FFHR-d1, are being conducted in the National Institute for Fusion Science. Three different cooling schemes and conductor types have been proposed for the superconducting magnet system. A multiscale structural analysis is used to assess the mechanical characteristics of the magnet structure, taking into account the types of cooling schemes and superconductors. Multiscale analysis evaluates both the stress distribution in the coil support structure and local stress in the constituents of the superconductors without rebuilding a finite-element model of the support structure. Concerning a segmented fabrication of the helical coils using a high-temperature superconductor, the feasibility of segment installation is confirmed using a three-dimensional printing model, which identifies the maximum segment length and the necessary gap in the coil casing to install a segment.
- 18 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (3) , 1-5
Open AccessMultiscale Stress Analysis and 3D Fitting Structure of Superconducting Coils for the Helical Fusion Reactor
Conceptual design studies for the Large-Helical-Device-type helical reactor, i.e., FFHR-d1, are being conducted in the National Institute for Fusion Science. Three different cooling schemes and conductor types have been proposed for the superconducting magnet system. A multiscale structural analysis is used to assess the mechanical characteristics of the magnet structure, taking into account the types of cooling schemes and superconductors. Multiscale analysis evaluates both the stress distribution in the coil support structure and local stress in the constituents of the superconductors without rebuilding a finite-element model of the support structure. Concerning a segmented fabrication of the helical coils using a high-temperature superconductor, the feasibility of segment installation is confirmed using a three-dimensional printing model, which identifies the maximum segment length and the necessary gap in the coil casing to install a segment.
- 1 January 2015
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 10, 3405011
A Cooling Concept for Indirectly Cooled Superconducting Magnets for the Fusion Reactor FFHR
- 1 January 2015
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 10, 3405011
A Cooling Concept for Indirectly Cooled Superconducting Magnets for the Fusion Reactor FFHR
- 24 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Evaluation of ITER TF Coil Joint Performance
To evaluate the ITER TF joint performance, the joint test sample, which consists of two short TF conductors and has full size joint, shall be tested using NIFS test facility under the condition of current of 68 kA and external field of 2 T. For high accuracy, the issue of voltage difference between cable and jacket had been anticipated in the evaluation of joint resistance. If a voltage difference exist between them, it is difficult to measure real joint resistance using voltage taps on the jacket. Therefore, the author first calculated the position where voltage of cable and jacket become equipotential and then decided the voltage tap position where the influence of voltage drop could be avoided. Thus, a high accuracy measurement of joint resistance could be achieved and the joint resistance was accurately evaluated as around 1 nΩ, which is well below the ITER requirement of 3 nΩ.
- 24 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Evaluation of ITER TF Coil Joint Performance
To evaluate the ITER TF joint performance, the joint test sample, which consists of two short TF conductors and has full size joint, shall be tested using NIFS test facility under the condition of current of 68 kA and external field of 2 T. For high accuracy, the issue of voltage difference between cable and jacket had been anticipated in the evaluation of joint resistance. If a voltage difference exist between them, it is difficult to measure real joint resistance using voltage taps on the jacket. Therefore, the author first calculated the position where voltage of cable and jacket become equipotential and then decided the voltage tap position where the influence of voltage drop could be avoided. Thus, a high accuracy measurement of joint resistance could be achieved and the joint resistance was accurately evaluated as around 1 nΩ, which is well below the ITER requirement of 3 nΩ.
- 1 January 2014
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 9, 3405034
Development of an Indirectly Cooled Superconductor for the LHD Fusion Reactor FFHR
- 1 January 2014
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 9, 3405034
Development of an Indirectly Cooled Superconductor for the LHD Fusion Reactor FFHR
- 12 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 8400904
Comparison of Analytical Estimation and 3-D Measurement of All Strands Location in CIC Conductor
It has been observed that the measured critical currents of cable-in-conduit-conductors (CICC) in some experiments are smaller than the expected ones. One of the reasons is the occurrence of unbalanced current at steady state caused by uneven contact resistances between strands. Because the contact resistance between strands is dependent on the contact length, the number of contacts and the loop length between strands, we need information about all strands' locations in the CICC. Therefore, we developed an evaluation method that describes the locations of every strand in the CICC in consideration of the twist disorder based on manufacture processes and elastic potential energy. Moreover, we compared the contact number and length between strands obtained by our calculated strands' positions with measured ones. We found that both results are in good agreement and clarified the validity of our calculation method of all strands' positions in the CICC.
- 12 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 8400904
Comparison of Analytical Estimation and 3-D Measurement of All Strands Location in CIC Conductor
It has been observed that the measured critical currents of cable-in-conduit-conductors (CICC) in some experiments are smaller than the expected ones. One of the reasons is the occurrence of unbalanced current at steady state caused by uneven contact resistances between strands. Because the contact resistance between strands is dependent on the contact length, the number of contacts and the loop length between strands, we need information about all strands' locations in the CICC. Therefore, we developed an evaluation method that describes the locations of every strand in the CICC in consideration of the twist disorder based on manufacture processes and elastic potential energy. Moreover, we compared the contact number and length between strands obtained by our calculated strands' positions with measured ones. We found that both results are in good agreement and clarified the validity of our calculation method of all strands' positions in the CICC.
- 1 January 2013
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 8, 2405008
Effect of Bending on Critical Current and n-Value of React-and-Jacket Processed Nb3Sn Conductor
- 1 January 2013
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 8, 2405008
Effect of Bending on Critical Current and n-Value of React-and-Jacket Processed Nb3Sn Conductor
- Open Access
- 1 January 2012
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 7, 2405008
Long-Term Monitoring of Hydraulic Characteristics of LHD Poloidal Coils
We present a fourteen-year data summary of the hydraulic characteristics of the large helical device (LHD) poloidal coils. The superconductors of the poloidal coils are cable-in-conduit conductors (CICC) cooled by circulated supercritical helium. The long-term operation of the LHD demonstrates that the initial hydraulic characteristics can be maintained without flow obstruction. Fine mesh filters installed at the inlet trapped impurities during cool-down of the coils, confirmed by monitoring the pressure drop of the filters. The filters have an important role in removing particles of impurities in the helium and maintaining the hydraulic characteristics of the coils
- 1 January 2012
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 7, 2405008
Open AccessLong-Term Monitoring of Hydraulic Characteristics of LHD Poloidal Coils
We present a fourteen-year data summary of the hydraulic characteristics of the large helical device (LHD) poloidal coils. The superconductors of the poloidal coils are cable-in-conduit conductors (CICC) cooled by circulated supercritical helium. The long-term operation of the LHD demonstrates that the initial hydraulic characteristics can be maintained without flow obstruction. Fine mesh filters installed at the inlet trapped impurities during cool-down of the coils, confirmed by monitoring the pressure drop of the filters. The filters have an important role in removing particles of impurities in the helium and maintaining the hydraulic characteristics of the coils