SHScott Hoge

Scott Hoge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Scott Hoge has a total of 109 co-authors. Here are the top co-authors by number of shared publications:

  • Dana H. Brooks

    Department of Electrical & Computer Engineering, Center for Digital Signal Processing, Northeastern University, Boston, Massachusetts, USA

    9 shared publications
  • Bruno Madore

    Department of Radiology, Brigham and Women’s Hospital Harvard Medical School Boston Massachusetts

    6 shared publications
  • Robert A. Kraft

    School of Biomedical Engineering and Science, Virginia Tech - Wake Forest, University School of Medicine, Winston-Salem, NC, USA

    6 shared publications
  • D.H. Brooks

    4 shared publications
  • Huan Tan

    School of Biomed. Eng. and Sci., Virginia Tech-Wake Forest University, Winston-Salem, NC, USA

    4 shared publications
  • Jonathan R. Polimeni

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States

    4 shared publications

Latest Publications

  • Accelerating joint relaxation‐diffusion MRI by integrating time division multiplexing and simultaneous multi‐slice (TDM‐SMS) strategies

    by Yang Ji, W. Scott Hoge, Borjan Gagoski, Carl‐Fredrik Westin, Yogesh Rathi, Lipeng Ning

    Purpose: To accelerate the acquisition of relaxation‐diffusion imaging by integrating time‐division multiplexing (TDM) with simultaneous multi‐slice (SMS) for EPI and evaluate imaging quality and diffusion measures.Methods: The time‐division multiplexing (TDM) technique and SMS method were integrated to achieve a high slice‐acceleration (e.g., 6×) factor for acquiring relaxation‐diffusion MRI. Two variants of the sequence, referred to as TDM3e‐SMS and TDM2s‐SMS, were developed to simultaneously acquire slice groups with three distinct TEs and two slice groups with the same TE, respectively. Both sequences were evaluated on a 3T scanner with in vivo human brains and compared with standard single‐band (SB) ‐EPI and SMS‐EPI using diffusion measures and tractography results.Results: Experimental results showed that the TDM3e‐SMS sequence with total slice acceleration of 6 (multiplexing factor (MP) = 3 × multi‐band factor (MB) = 2) provided similar image intensity and microstructure measures compared to standard SMS‐EPI with MB = 2, and yielded less bias in intensity compared to standard SMS‐EPI with MB = 4. The three sequences showed a similar positive correlation between TE and mean kurtosis (MK) and a negative correlation between TE and mean diffusivity (MD) in white matter. Multi‐fiber tractography also shows consistency of results in TE‐dependent measures between different sequences. The TDM2s‐SMS sequence (MP = 2, MB = 2) also provided imaging measures similar to standard SMS‐EPI sequences (MB = 2) for single‐TE diffusion imaging.Conclusions: The TDM‐SMS sequence can provide additional 2× to 3× acceleration to SMS without degrading imaging quality. With the significant reduction in scan time, TDM‐SMS makes joint relaxation‐diffusion MRI a feasible technique in neuroimaging research to investigate new markers of brain disorders.


  • Dynamic distortion correction for functional MRI using FID navigators

    by Tess E. Wallace, Jonathan R. Polimeni, Jason P. Stockmann, W. Scott Hoge, Tobias Kober, Simon K. Warfield, Onur Afacan

    Purpose: To develop a method for slice‐wise dynamic distortion correction for EPI using rapid spatiotemporal B0 field measurements from FID navigators (FIDnavs) and to evaluate the efficacy of this new approach relative to an established data‐driven technique.Methods: A low‐resolution reference image was used to create a forward model of FIDnav signal changes to enable estimation of spatiotemporal B0 inhomogeneity variations up to second order from measured FIDnavs. Five volunteers were scanned at 3 T using a 64‐channel coil with FID‐navigated EPI. The accuracy of voxel shift measurements and geometric distortion correction was assessed for experimentally induced magnetic field perturbations. The temporal SNR was evaluated in EPI time‐series acquired at rest and with a continuous nose‐touching action, before and after image realignment.Results: Field inhomogeneity coefficients and voxel shift maps measured using FIDnavs were in excellent agreement with multi‐echo EPI measurements. The FID‐navigated distortion correction accurately corrected image geometry in the presence of induced magnetic field perturbations, outperforming the data‐driven approach in regions with large field offsets. In functional MRI scans with nose touching, FIDnav‐based correction yielded temporal SNR gains of 30% in gray matter. Following image realignment, which accounted for global image shifts, temporal SNR gains of 3% were achieved.Conclusions: Our proposed application of FIDnavs enables slice‐wise dynamic distortion correction with high temporal efficiency. We achieved improved signal stability by leveraging the encoding information from multichannel coils. This approach can be easily adapted to other EPI‐based sequences to improve temporal SNR for a variety of clinical and research applications.


  • Multipathway multi‐echo (MPME) imaging: all main MR parameters mapped based on a single 3D scan

    by Cheng‐Chieh Cheng, Frank Preiswerk, W. Scott Hoge, Tai‐Hsin Kuo, Bruno Madore

    Purpose: Quantitative parameter maps, as opposed to qualitative grayscale images, may represent the future of diagnostic MRI. A new quantitative MRI method is introduced here that requires a single 3D acquisition, allowing good spatial coverage to be achieved in relatively short scan times. Methods: A multipathway multi‐echo sequence was developed, and at least 3 pathways with 2 TEs were needed to generate T 1 , T 2 , T 2 * , B 1 + , and B 0 maps. The method required the central k ‐space region to be sampled twice, with the same sequence but with 2 very different nominal flip angle settings. Consequently, scan time was only slightly longer than that of a single scan. The multipathway multi‐echo data were reconstructed into parameter maps, for phantom as well as brain acquisitions, in 5 healthy volunteers at 3 T. Spatial resolution, matrix size, and FOV were 1.2 × 1.0 × 1.2 mm 3 , 160 × 192 × 160, and 19.2 × 19.2 × 19.2 cm 3 (whole brain), acquired in 11.5 minutes with minimal acceleration. Validation was performed against T 1 , T 2 , and T 2 * maps calculated from gradient‐echo and spin‐echo data. Results: In Bland‐Altman plots, bias and limits of agreement for T 1 and T 2 results in vivo and in phantom were −2.9/±125.5 ms ( T 1 in vivo), −4.8/±20.8 ms ( T 2 in vivo), −1.5/±18.1 ms ( T 1 in phantom), and −5.3/±7.4 ms ( T 2 in phantom), for regions of interest including given brain structures or phantom compartments. Due to relatively high noise levels, the current implementation of the approach may prove more useful for region of interest–based as opposed to pixel‐based interpretation. Conclusions: We proposed a novel approach to quantitatively map MR parameters based on a multipathway multi‐echo acquisition.


  • Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods

    by Rodrigo A. Lobos, Tae Hyung Kim, W. Scott Hoge, Justin P. Haldar

    Structured low-rank matrix models have previously been introduced to enable calibrationless MR image reconstruction from sub-Nyquist data, and such ideas have recently been extended to enable navigator-free echo-planar imaging (EPI) ghost correction. This paper presents a novel theoretical analysis which shows that, because of uniform subsampling, the structured low-rank matrix optimization problems for EPI data will always have either undesirable or non-unique solutions in the absence of additional constraints. This theory leads us to recommend and investigate problem formulations for navigator-free EPI that incorporate side information from either image-domain or k-space domain parallel imaging methods. The importance of using nonconvex low-rank matrix regularization is also identified. We demonstrate using phantom and in vivo data that the proposed methods are able to eliminate ghost artifacts for several navigator-free EPI acquisition schemes, obtaining better performance in comparison with the state-of-the-art methods across a range of different scenarios. Results are shown for both single-channel acquisition and highly accelerated multi-channel acquisition.


  • Dual‐polarity slice‐GRAPPA for concurrent ghost correction and slice separation in simultaneous multi‐slice EPI

    by W. Scott Hoge, Kawin Setsompop, Jonathan R. Polimeni

    Purpose: A ghost correction strategy for Simultaneous Multi‐Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS‐EPI rely on navigator data that contain phase errors from all slices in the simultaneously acquired slice‐group. These navigator data may contain spatially nonlinear phase differences near regions of B0 inhomogeneity, which violates the linear model employed by most EPI ghost correction algorithms, resulting in poor reconstructions.Methods: Dual‐Polarity GRAPPA (DPG) was previously shown to accurately model and correct both spatially nonlinear and 2D phase errors in conventional single‐slice EPI data. Here, an extension we call Dual‐Polarity slice‐GRAPPA (DPsG) is adapted to the slice‐GRAPPA method and applied to SMS‐EPI data for slice separation and ghost correction concurrently—eliminating the need for a separate ghost correction step while also providing improved slice‐specific EPI phase error correction.Results: Images from in vivo SMS‐EPI data reconstructed using DPsG in place of conventional Nyquist ghost correction and slice‐GRAPPA are presented. DPsG is shown to reduce ghosting artifacts and provide improved temporal SNR compared to the conventional reconstruction.Conclusion: The proposed use of DPsG for SMS‐EPI reconstruction can provide images with lower artifact levels, higher image fidelity, and improved time‐series stability compared to conventional reconstruction methods.


  • Genetic and neural predictors of behavioral weight loss treatment: A preliminary study

    by Eunice Y. Chen, Thomas M. Olino, Chris J. Conklin, Feroze B. Mohamed, W. Scott Hoge, Gary D. Foster, Jean M. Arlt, Kalina Eneva, Judy R. Kidd, Kenneth R. Kidd, et al.

    To examine neural mechanisms of action in behavioral weight loss treatment (BWL) and explore neural and genetic predictors of BWL. Neural activation to milkshake receipt and genetics were compared in 17 women with obesity who received 12 weeks of BWL and 17 women who received no intervention. Participants were scanned twice using functional magnetic resonance imaging at baseline and 12 weeks. Weight was assessed at baseline, 12, 36, and 60 weeks. BWL participants lost more weight than controls at 12 weeks (-4.82% versus -0.70%). After 12 weeks, BWL had greater reduction in right caudate activation response to milk shake receipt than did controls. Among BWL participants, baseline to 12-week reduction in frontostriatal activation to milk shake predicted greater weight loss at 12, 36, and 60 weeks. Possessing the A/A or T/A genotype of the fat mass and obesity-associated (FTO) variant rs9939609 predicted greater weight loss at 12 and 36 weeks. These preliminary data reveal that reduction in right caudate activation may be a neural mechanism of weight loss in BWL, and baseline FTO variant and reduction in frontostriatal activation during BWL predict short- and long-term weight loss. These findings require replication in larger samples.


  • Sampling and recovery of MRI data using low rank tensor models

    by Daniel Banco, Shuchin Aeron, W. Scott Hoge

    In this paper we investigate the utility of several low-rank models for recovery of Magnetic Resonance Imaging (MRI) data from limited sampling in the k - t space for dynamic imaging. In particular, for 3D temporal (2D space + time) MRI data we employ several tensor factorization techniques and assess the degree of dimensionality reduction, or compressibility, that can be obtained. This algebraic approach is more data adaptive, in contrast to existing compressed sensing (CS) based methods that exploit sparsity in a transform domain, such as wavelets or total variation. Further, we compare these tensor factorization approaches in recovering temporal MRI data under limited sampling. Respecting traditional MRI data acquisition methods, the sampling process is restricted to be uniformly random along only one k space direction. Experimental results on synthetically sub-sampled MRI data show promise in using tensor factorization for sampling and recovery of MRI data.


  • HybridMRI‐Ultrasound acquisitions, and scannerless real‐time imaging

    by Frank Preiswerk, Matthew Toews, Cheng‐Chieh Cheng, Jr‐Yuan George Chiou, Chang‐Sheng Mei, Lena F. Schaefer, W. Scott Hoge, Benjamin M. Schwartz, Lawrence P. Panych, Bruno Madore

    Purpose: To combine MRI, ultrasound, and computer science methodologies toward generating MRI contrast at the high frame rates of ultrasound, inside and even outside the MRI bore.Methods: A small transducer, held onto the abdomen with an adhesive bandage, collected ultrasound signals during MRI. Based on these ultrasound signals and their correlations with MRI, a machine‐learning algorithm created synthetic MR images at frame rates up to 100 per second. In one particular implementation, volunteers were taken out of the MRI bore with the ultrasound sensor still in place, and MR images were generated on the basis of ultrasound signal and learned correlations alone in a “scannerless” manner.Results: Hybrid ultrasound‐MRI data were acquired in eight separate imaging sessions. Locations of liver features, in synthetic images, were compared with those from acquired images: The mean error was 1.0 pixel (2.1 mm), with best case 0.4 and worst case 4.1 pixels (in the presence of heavy coughing). For results from outside the bore, qualitative validation involved optically tracked ultrasound imaging with/without coughing.Conclusion: The proposed setup can generate an accurate stream of high‐speed MR images, up to 100 frames per second, inside or even outside the MR bore. Magn Reson Med 78:897–908, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


  • Hybrid Utrasound and MRI Acquisitions for High-Speed Imaging of Respiratory Organ Motion

    by Frank Preiswerk, Matthew Toews, W. Scott Hoge, Jr-Yuan George Chiou, Lawrence P. Panych, William M. Wells, Bruno Madore

    Magnetic Resonance (MR) imaging provides excellent image quality at a high cost and low frame rate. Ultrasound (US) provides poor image quality at a low cost and high frame rate. We propose an instance-based learning system to obtain the best of both worlds: high quality MR images at high frame rates from a low cost single-element US sensor. Concurrent US and MRI pairs are acquired during a relatively brief offline learning phase involving the US transducer and MR scanner. High frame rate, high quality MR imaging of respiratory organ motion is then predicted from US measurements, even after stopping MRI acquisition, using a probabilistic kernel regression framework. Experimental results show predicted MR images to be highly representative of actual MR images.