Dynamic distortion correction for functional MRI using FID navigators
- 24 September 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1294-1307
Abstract
Purpose: To develop a method for slice‐wise dynamic distortion correction for EPI using rapid spatiotemporal B0 field measurements from FID navigators (FIDnavs) and to evaluate the efficacy of this new approach relative to an established data‐driven technique.Methods: A low‐resolution reference image was used to create a forward model of FIDnav signal changes to enable estimation of spatiotemporal B0 inhomogeneity variations up to second order from measured FIDnavs. Five volunteers were scanned at 3 T using a 64‐channel coil with FID‐navigated EPI. The accuracy of voxel shift measurements and geometric distortion correction was assessed for experimentally induced magnetic field perturbations. The temporal SNR was evaluated in EPI time‐series acquired at rest and with a continuous nose‐touching action, before and after image realignment.Results: Field inhomogeneity coefficients and voxel shift maps measured using FIDnavs were in excellent agreement with multi‐echo EPI measurements. The FID‐navigated distortion correction accurately corrected image geometry in the presence of induced magnetic field perturbations, outperforming the data‐driven approach in regions with large field offsets. In functional MRI scans with nose touching, FIDnav‐based correction yielded temporal SNR gains of 30% in gray matter. Following image realignment, which accounted for global image shifts, temporal SNR gains of 3% were achieved.Conclusions: Our proposed application of FIDnavs enables slice‐wise dynamic distortion correction with high temporal efficiency. We achieved improved signal stability by leveraging the encoding information from multichannel coils. This approach can be easily adapted to other EPI‐based sequences to improve temporal SNR for a variety of clinical and research applications.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R00 EB021349, R01 EB019437, R01 EB019483)
- Thrasher Research Fund (Early Career Award #14989)
- National Institute of Mental Health (R01 MH111419)
- National Institute of Neurological Disorders and Stroke (R01 NS079788, R01 NS106030)
This publication has 44 references indexed in Scilit:
- Effect of head motion on MRI B0 field distributionMagnetic Resonance in Medicine, 2018
- Reference‐free unwarping of EPI data using dynamic off‐resonance correction with multiecho acquisition (DOCMA)Magnetic Resonance in Medicine, 2012
- Magnetic field shift due to mechanical vibration in functional magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imagingNeuroImage, 2003
- An Evaluation of the Use of Magnetic Field Maps to Undistort Echo-Planar ImagesNeuroImage, 2003
- Real‐time autoshimming for echo planar timecourse imagingMagnetic Resonance in Medicine, 2002
- Respiration‐inducedB0fluctuations and their spatial distribution in the human brain at 7 TeslaMagnetic Resonance in Medicine, 2002
- Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imagingMagnetic Resonance in Medicine, 2002
- Compensation of Susceptibility-Induced BOLD Sensitivity Losses in Echo-Planar fMRI ImagingNeuroImage, 2002
- Correction for geometric distortion in echo planar images from B0 field variationsMagnetic Resonance in Medicine, 1995