Hamdi Mıhçıokur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hamdi Mıhçıokur has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Merve Oğuz
Erciyes University Engineering Faculty Environmental Engineering Department, 38039, Kayseri, Turkey
3 shared publications - İbrahim Uyanık
Erciyes University
2 shared publications - Adem Yurtsever
Department of Environmental Engineering Faculty of Engineering İstanbul University‐Cerrahpaşa Istanbul Türkiye
1 shared publication - Bilgin Yazlık
NEVŞEHİR ÜNİVERSİTESİ, MÜHENDİSLİK-MİMARLIK FAKÜLTESİ
1 shared publication Dilşad Öztürk
Erciyes University Engineering Faculty, Environmental Engineering Department, Kayseri, Turkey
1 shared publication- Duygu Osman
Environmental Engineering Department, Erciyes University, Kayseri, Turkey
1 shared publication
Latest Publications
- 25 September 2026
- Published by Istanbul University in Aquatic Sciences and Engineering
- Vol. 41 (4) , 237-250
A Novel Method for Chemical Oxygen Demand (Cod) Estimation Using Alexnet
The Chemical Oxygen Demand (COD) analysis is a cumulative parameter that indicates the extent of organic pollution in water. In the COD analysis, the reagents reacted with the organic matter in the water, producing distinct colour intensities, with the degree of reaction varying according to the organic load. The COD concentration was determined by measuring the absorbance of the resulting colour using the spectrophotometric method. This analysis, which is traditionally performed using a spectrophotometer, is conducted for the first time in this study without the use of a spectrophotometer, using mobile device support and AlexNet. Chemicals necessary for COD analysis are produced, and the reaction procedures are executed. The resulting mixtures were photographed with the camera of the mobile device and input into the developed software. The mobile application predicts the image class using an AlexNet architecture with Leaky Rectified Linear Unit (LeakyReLU) activations in the background. The network, trained on a dataset of 504 images across 21 classes, each containing 24 images per class, displays the estimated results with 96.19% accuracy, 97.85% precision, 96.19% recall, 97.05% F1-score, and an R² value of 0.9892. These results are consistent with those obtained using a spectrophotometer. The proposed method accurately estimates the COD concentration without using the values measured by the spectrophotometer at 420 and 600 nm. The proposed method successfully estimates the COD concentration using only images. The proposed method is advantageous because it eliminates the need for a spectrophotometer in COD analysis.
- 25 September 2026
- Published by Istanbul University in Aquatic Sciences and Engineering
- Vol. 41 (4) , 237-250
A Novel Method for Chemical Oxygen Demand (Cod) Estimation Using Alexnet
The Chemical Oxygen Demand (COD) analysis is a cumulative parameter that indicates the extent of organic pollution in water. In the COD analysis, the reagents reacted with the organic matter in the water, producing distinct colour intensities, with the degree of reaction varying according to the organic load. The COD concentration was determined by measuring the absorbance of the resulting colour using the spectrophotometric method. This analysis, which is traditionally performed using a spectrophotometer, is conducted for the first time in this study without the use of a spectrophotometer, using mobile device support and AlexNet. Chemicals necessary for COD analysis are produced, and the reaction procedures are executed. The resulting mixtures were photographed with the camera of the mobile device and input into the developed software. The mobile application predicts the image class using an AlexNet architecture with Leaky Rectified Linear Unit (LeakyReLU) activations in the background. The network, trained on a dataset of 504 images across 21 classes, each containing 24 images per class, displays the estimated results with 96.19% accuracy, 97.85% precision, 96.19% recall, 97.05% F1-score, and an R² value of 0.9892. These results are consistent with those obtained using a spectrophotometer. The proposed method accurately estimates the COD concentration without using the values measured by the spectrophotometer at 420 and 600 nm. The proposed method successfully estimates the COD concentration using only images. The proposed method is advantageous because it eliminates the need for a spectrophotometer in COD analysis.
- 14 February 2026
- Published by Oxford University Press (OUP) in Integrated Environmental Assessment and Management
- Vol. 22 (4) , 1297-1308
Microplastics in an industrial zone wastewater treatment plant: Characterization, fate, and risk assessment
The majority of research on microplastic (MP) characterization and removal has focused on municipal wastewater treatment plants (WWTPs). Hence, this study was performed at an industrial zone WWTP with sectors of textile, plastic recycling, furniture, etc. Three monthly sampling campaigns were conducted to analyze the MPs (abundance, shape, color, size, polymer type) and to investigate their fate and removal rate in the WWTP. Furthermore, the environmental risk assessment using EPI Suite modeling was conducted for common MP polymer types. The results indicated that the highest MP concentration was detected in the sludge sample (3,734 MP/L), whereas the lowest one was observed in the effluent sample (52 MP/L). Whereas large MPs (5 mm to 425 µm) were removed by primary treatment processes, smaller MPs (250 to 125 µm) showed a tendency for accumulation in the sludge. The most dominant MP shapes were fiber and fragment in both wastewater and sludge samples, whereas the most dominant polymer types were polypropylene (38%), polyethylene (24%), and polyethylene terephthalate (11%). The environmental risk assessment reveals that polyvinyl chloride, polyethylene terephthalate, and polystyrene, present in minimal quantities in this study, are more likely to impact the growth of living organisms significantly compared to more common polymer types like polypropylene and polyethylene. Although the overall MP removal efficiency of the industrial zone WWTP was 88%, a significant quantity of MPs (1.5 × 109 MP/day) was still discharged into the Kızılırmak river that is used mostly for irrigation. Effective control/reduction of MP discharge necessitates the implementation of tertiary treatment processes in industrial zone WWTPs to prevent soil pollution.
- 14 February 2026
- Published by Oxford University Press (OUP) in Integrated Environmental Assessment and Management
- Vol. 22 (4) , 1297-1308
Microplastics in an industrial zone wastewater treatment plant: Characterization, fate, and risk assessment
The majority of research on microplastic (MP) characterization and removal has focused on municipal wastewater treatment plants (WWTPs). Hence, this study was performed at an industrial zone WWTP with sectors of textile, plastic recycling, furniture, etc. Three monthly sampling campaigns were conducted to analyze the MPs (abundance, shape, color, size, polymer type) and to investigate their fate and removal rate in the WWTP. Furthermore, the environmental risk assessment using EPI Suite modeling was conducted for common MP polymer types. The results indicated that the highest MP concentration was detected in the sludge sample (3,734 MP/L), whereas the lowest one was observed in the effluent sample (52 MP/L). Whereas large MPs (5 mm to 425 µm) were removed by primary treatment processes, smaller MPs (250 to 125 µm) showed a tendency for accumulation in the sludge. The most dominant MP shapes were fiber and fragment in both wastewater and sludge samples, whereas the most dominant polymer types were polypropylene (38%), polyethylene (24%), and polyethylene terephthalate (11%). The environmental risk assessment reveals that polyvinyl chloride, polyethylene terephthalate, and polystyrene, present in minimal quantities in this study, are more likely to impact the growth of living organisms significantly compared to more common polymer types like polypropylene and polyethylene. Although the overall MP removal efficiency of the industrial zone WWTP was 88%, a significant quantity of MPs (1.5 × 109 MP/day) was still discharged into the Kızılırmak river that is used mostly for irrigation. Effective control/reduction of MP discharge necessitates the implementation of tertiary treatment processes in industrial zone WWTPs to prevent soil pollution.
- 16 April 2023
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 58 (5) , 498-505
Evaluation of ciprofloxacin (CIP) and clarithromycin (CLA) adsorption with weathered PVC microplastics
The sorption kinetics of two of the most frequently used antibiotics onto recycled (weathered) polyvinyl chloride (PVC) was investigated, using Freundlich and Langmuir isotherm models. Various experimental conditions were set, including pH, contact time, rotational speed, temperature, and initial concentration. The batch experimental results indicated that Freundlich model was better fitted than Langmuir (R2: 98.7 and 84.7, for CIP and CLA respectively). Maximum adsorption capacity is 45.9 mg/g and 22.0 mg/g for CIP and CLA, respectively. Enthalpy (ΔH), and entropy (ΔS) values were negative for CIP, indicating that the reaction was exothermic and spontaneous, respectively. It was vice versa for CLA. Field emission scanning electron microscope (FESEM) and Fourier transform infrared spectrometer (FT-IR) analysis confirmed the physical adsorption mechanism. The results demonstrated that the recycled PVC microplastic has a good capacity for adsorption for both antibiotics.
- 16 April 2023
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 58 (5) , 498-505
Evaluation of ciprofloxacin (CIP) and clarithromycin (CLA) adsorption with weathered PVC microplastics
The sorption kinetics of two of the most frequently used antibiotics onto recycled (weathered) polyvinyl chloride (PVC) was investigated, using Freundlich and Langmuir isotherm models. Various experimental conditions were set, including pH, contact time, rotational speed, temperature, and initial concentration. The batch experimental results indicated that Freundlich model was better fitted than Langmuir (R2: 98.7 and 84.7, for CIP and CLA respectively). Maximum adsorption capacity is 45.9 mg/g and 22.0 mg/g for CIP and CLA, respectively. Enthalpy (ΔH), and entropy (ΔS) values were negative for CIP, indicating that the reaction was exothermic and spontaneous, respectively. It was vice versa for CLA. Field emission scanning electron microscope (FESEM) and Fourier transform infrared spectrometer (FT-IR) analysis confirmed the physical adsorption mechanism. The results demonstrated that the recycled PVC microplastic has a good capacity for adsorption for both antibiotics.
- 1 April 2022
- Published by Allerton Press in Journal of Water Chemistry and Technology
- Vol. 44 (2) , 116-122
Investigation of Amoxicillin and Ciprofloxacin Behaviours in Sequencing Batch Reactor and Their Effects on Chemical Oxygen Demand Removal Efficiencies
In this study, the behaviors of amoxicillin and ciprofloxacin were investigated in the conventional treatment systems in both theoretical and experimental
- 1 April 2022
- Published by Allerton Press in Journal of Water Chemistry and Technology
- Vol. 44 (2) , 116-122
Investigation of Amoxicillin and Ciprofloxacin Behaviours in Sequencing Batch Reactor and Their Effects on Chemical Oxygen Demand Removal Efficiencies
In this study, the behaviors of amoxicillin and ciprofloxacin were investigated in the conventional treatment systems in both theoretical and experimental
- 11 August 2021
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 57 (7) , 1030-1042
Production of innovative magnetic adsorbent Fe3O4@PEI®Tween 85 and removal of oxytetracycline from aqueous media
The presence of pharmaceutical in waters has raised the challenge of antimicrobial resistance. This paper presents a study on the adsorption of Oxytetracycline (OTC) from an aqueous using a modified Iron Oxide (Fe3O4) which was modified with Polyethyleneimine (PEI) polymer and coated with Polyoxyethylene Sorbitan Trioleate (Tween 85) surfactant. The adsorption performance was examined the effect of pH, temperature, contact time, adsorbent dosage and drug concentration based on batch experiments. High OTC removal rates of about 98% for the 1:2 with Tween 85 were obtained at pH 4, similar removal efficiency was obtained for the 1:2 Tween 85-free at pH 3. Also, it was seen that the adsorption process was a physical and exothermic process in terms of thermodynamics. The adsorption can be well explained by Freundlich isotherm model. The results demonstrate that the modified magnetic material, with low concentration of 0.025 g, have great potential to capture OTC. Also, qm value (277.8 mg/g) of the adsorbent shows its great potential and the adsorbent reaches its maximum capacity in a short time (~10 minutes).The experimental results reveal that Fe3O4@PEI®Tween 85 would be a promising solution with high removal efficiency and low-cost adsorbent for water matrices protection.
- 11 August 2021
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 57 (7) , 1030-1042
Production of innovative magnetic adsorbent Fe3O4@PEI®Tween 85 and removal of oxytetracycline from aqueous media
The presence of pharmaceutical in waters has raised the challenge of antimicrobial resistance. This paper presents a study on the adsorption of Oxytetracycline (OTC) from an aqueous using a modified Iron Oxide (Fe3O4) which was modified with Polyethyleneimine (PEI) polymer and coated with Polyoxyethylene Sorbitan Trioleate (Tween 85) surfactant. The adsorption performance was examined the effect of pH, temperature, contact time, adsorbent dosage and drug concentration based on batch experiments. High OTC removal rates of about 98% for the 1:2 with Tween 85 were obtained at pH 4, similar removal efficiency was obtained for the 1:2 Tween 85-free at pH 3. Also, it was seen that the adsorption process was a physical and exothermic process in terms of thermodynamics. The adsorption can be well explained by Freundlich isotherm model. The results demonstrate that the modified magnetic material, with low concentration of 0.025 g, have great potential to capture OTC. Also, qm value (277.8 mg/g) of the adsorbent shows its great potential and the adsorbent reaches its maximum capacity in a short time (~10 minutes).The experimental results reveal that Fe3O4@PEI®Tween 85 would be a promising solution with high removal efficiency and low-cost adsorbent for water matrices protection.
- 30 June 2021
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 42 (2) , 310-320
Environmental risk assessment of commonly used anti-cancer drugs
This study has been focused on the commonly used anti-cancer drugs (ACDs) in Turkey in terms of environmental toxicity, behaviors in sewage treatment plants (STPs), biodegradability and physicochemical properties. For this purpose, EPI Suite, estimation programme, has been used by employing BCFWIN, KOWWIN, KOCWIN, HENRYWIN, AEROWIN, ECOSAR, BIOWIN, STPWIN suites. Among 13 selected ACDs, Tamoxifen has been found as the most risky pharmaceutical due to its high Predicted Environmental Concentration (PEC) / Predicted No Effect Concentration (PNEC) value (2.96350). Even if the total removal efficiency of Tamoxifen is rather high (97.24%), the considerable portion (71.50%) has been retained on the treatment sludge leading to compose hazardous waste. Additionally, physicochemical parameters, log Kow (6.30), Kd (62230 L/g), log Koc (4.400) and BCF (6689 L/kg), calculated for Tamoxifen indicate that Tamoxifen has the highest sorption potential and tends to bioaccumulate in organisms, respectively.
- 30 June 2021
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 42 (2) , 310-320
Environmental risk assessment of commonly used anti-cancer drugs
This study has been focused on the commonly used anti-cancer drugs (ACDs) in Turkey in terms of environmental toxicity, behaviors in sewage treatment plants (STPs), biodegradability and physicochemical properties. For this purpose, EPI Suite, estimation programme, has been used by employing BCFWIN, KOWWIN, KOCWIN, HENRYWIN, AEROWIN, ECOSAR, BIOWIN, STPWIN suites. Among 13 selected ACDs, Tamoxifen has been found as the most risky pharmaceutical due to its high Predicted Environmental Concentration (PEC) / Predicted No Effect Concentration (PNEC) value (2.96350). Even if the total removal efficiency of Tamoxifen is rather high (97.24%), the considerable portion (71.50%) has been retained on the treatment sludge leading to compose hazardous waste. Additionally, physicochemical parameters, log Kow (6.30), Kd (62230 L/g), log Koc (4.400) and BCF (6689 L/kg), calculated for Tamoxifen indicate that Tamoxifen has the highest sorption potential and tends to bioaccumulate in organisms, respectively.
- 26 July 2018
- Published by Elsevier in Computational Materials Science
- Vol. 154, 65-74
Electrochemical oligomerization of selenophene and band structure of polyselenophene: A density functional theory study
- 26 July 2018
- Published by Elsevier in Computational Materials Science
- Vol. 154, 65-74
Electrochemical oligomerization of selenophene and band structure of polyselenophene: A density functional theory study
- 1 September 2016
- Published by Elsevier in Environmental Toxicology and Pharmacology
- Vol. 46, 174-182
Removal of oxytetracycline and determining its biosorption properties on aerobic granular sludge
- 1 September 2016
- Published by Elsevier in Environmental Toxicology and Pharmacology
- Vol. 46, 174-182
Removal of oxytetracycline and determining its biosorption properties on aerobic granular sludge
- Open Access
- 1 August 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (40) , 18688-18693
Hexavalent chromium removal from aqueous solutions by biosorbents (non-living activated sludge)
The removal of hexavalent chromium from aqueous solution was examined by the adsorption process using non-living activated sludge as an absorbent. The kinetics of the hexavalent chromium removal were examined in batch experiments for the concentrations between 1 and 20 mg/L hexavalent chromium solutions. The adsorbent dosage applied was 0.1 g dry weight of adsorbent/250 mL for the non-living activated sludge. Four different mixing times ranging from 30 to 120 min and six different pH values between 2 and 7 were assessed to find out the optimum mixing time and pH value. The removal efficiencies were above 56% for all hexavalent chromium concentrations and mixing times. The 250-rpm shaker speed at pH 2 gave the highest removal efficiency. The adsorption kinetics can be described by the pseudo-first-order and pseudo-second-order kinetic models. The rate constants were evaluated for all hexavalent chromium concentrations. This study showed that the hexavalent chromium adsorption kinetics of the non-living activated sludge fitted quite well to the pseudo-second-order kinetic model than the pseudo-first-order kinetic model. This reveals that it is comparative to the square of the concentration of chromium adsorption rate. These results show that non-living activated sludge could be effectively used as a low-cost and alternative absorbent for the removal of hexavalent chromium from aqueous solution.
- 1 August 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (40) , 18688-18693
Open AccessHexavalent chromium removal from aqueous solutions by biosorbents (non-living activated sludge)
The removal of hexavalent chromium from aqueous solution was examined by the adsorption process using non-living activated sludge as an absorbent. The kinetics of the hexavalent chromium removal were examined in batch experiments for the concentrations between 1 and 20 mg/L hexavalent chromium solutions. The adsorbent dosage applied was 0.1 g dry weight of adsorbent/250 mL for the non-living activated sludge. Four different mixing times ranging from 30 to 120 min and six different pH values between 2 and 7 were assessed to find out the optimum mixing time and pH value. The removal efficiencies were above 56% for all hexavalent chromium concentrations and mixing times. The 250-rpm shaker speed at pH 2 gave the highest removal efficiency. The adsorption kinetics can be described by the pseudo-first-order and pseudo-second-order kinetic models. The rate constants were evaluated for all hexavalent chromium concentrations. This study showed that the hexavalent chromium adsorption kinetics of the non-living activated sludge fitted quite well to the pseudo-second-order kinetic model than the pseudo-first-order kinetic model. This reveals that it is comparative to the square of the concentration of chromium adsorption rate. These results show that non-living activated sludge could be effectively used as a low-cost and alternative absorbent for the removal of hexavalent chromium from aqueous solution.
- 1 July 2014
- Published by Elsevier in Environmental Toxicology and Pharmacology
- Vol. 38 (1) , 79-83
Environmental risk assessment of selected pharmaceuticals in Turkey
- 1 July 2014
- Published by Elsevier in Environmental Toxicology and Pharmacology
- Vol. 38 (1) , 79-83
Environmental risk assessment of selected pharmaceuticals in Turkey