Marcin Brodecki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marcin Brodecki has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
C. Koukorava
5 shared publicationsJ. Jankowski
Nofer Institute of Occupational Medicine
5 shared publicationsS. Krim
5 shared publicationsE. Carinou
4 shared publicationsJ. Domienik
4 shared publications- Joanna Domienik
Nofer Institute of Occupational Medicine, Radiation Protection Department, Lodz, Poland
4 shared publications
Latest Publications
- Open Access
- 8 July 2024
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 37 (3) , 326-334
Analysis of dose distribution around a computed tomography scanner in terms of exposure to scattered ionizing radiation of caregivers of pediatric patients
Objectives: During computed tomography (CT), a large amount of ionizing radiation is emitted to ensure high quality of the obtained radiological image. This study measured the dose distribution around the CT scanner and the exposure of people staying near the CT scanner during the examination....
- 8 July 2024
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 37 (3) , 326-334
Open AccessAnalysis of dose distribution around a computed tomography scanner in terms of exposure to scattered ionizing radiation of caregivers of pediatric patients
Objectives: During computed tomography (CT), a large amount of ionizing radiation is emitted to ensure high quality of the obtained radiological image. This study measured the dose distribution around the CT scanner and the exposure of people staying near the CT scanner during the examination....
- Open Access
- 29 March 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 549-560
The effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap...
- 29 March 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 549-560
Open AccessThe effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap...
- 28 July 2017
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (3) , 715-727
Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses
The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician’s and patient’s doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians’ and nurses’ eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/ μ Gym 2 , 2.31e-4 ± 1.21e-4 mSv/ μ Gym 2 , and 2.60e-5 ± 1.57e-5 mSv/ μ Gym 2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/ μ Gym 2 , 1.70e-4 ± 1.01e-4 mSv/ μ Gym 2 , and 1.86e-5 ± 1.13e-5 mSv/ μ Gym 2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician’s work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.
- 28 July 2017
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (3) , 715-727
Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses
The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician’s and patient’s doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians’ and nurses’ eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/ μ Gym 2 , 2.31e-4 ± 1.21e-4 mSv/ μ Gym 2 , and 2.60e-5 ± 1.57e-5 mSv/ μ Gym 2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/ μ Gym 2 , 1.70e-4 ± 1.01e-4 mSv/ μ Gym 2 , and 1.86e-5 ± 1.13e-5 mSv/ μ Gym 2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician’s work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.
- 29 March 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , N19-N25
The effectiveness of lead glasses in reducing the doses to eye lenses during cardiac implantation procedures performed using x-ray tubes above the patient table
The dose reduction factors (DRF) for different types of lead glasses and C-arm units with x-ray tubes placed above the patient table were calculated from the results of measurements by loose thermoluminescent dosimeters (TLDs) and EYE-D dosimeters using a Rando phantom. The DRF values were analysed for different positions of routine dosimeters worn outside lead eyewear and confronted with DRFs calculated as the ratio of the dose equivalent to the eye measured with and without the eyewear. Moreover, for eye lens dosimeters designed to be worn behind lead glasses, multiplicative factors for various positions of dosimeter were derived in order to account for the differences between the doses measured on the inner side of the glasses and the dose equivalent to the eye lens. The DRFs calculated for the position of a routine dosimeter worn outside lead glasses on the band near the left eye lens are 5.6 and 5.7 for goggles and metallic glasses, respectively, while the DRFs calculated as the ratio of doses to the eyes measured with and without the eyewear are 10.2 and 9.9, respectively. Therefore, for dosimeters routinely used outside lead eyewear, the DRF calculated for the position of the dosimeter should be used. Otherwise, we can anticipate an almost two-fold underestimation of the doses. When the dosimeter is worn behind lead glasses, up to two-fold differences between the dose equivalent to the eye lens and the dose measured at the inner side of the glasses were observed depending on the dosimeter position.
- 29 March 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , N19-N25
The effectiveness of lead glasses in reducing the doses to eye lenses during cardiac implantation procedures performed using x-ray tubes above the patient table
The dose reduction factors (DRF) for different types of lead glasses and C-arm units with x-ray tubes placed above the patient table were calculated from the results of measurements by loose thermoluminescent dosimeters (TLDs) and EYE-D dosimeters using a Rando phantom. The DRF values were analysed for different positions of routine dosimeters worn outside lead eyewear and confronted with DRFs calculated as the ratio of the dose equivalent to the eye measured with and without the eyewear. Moreover, for eye lens dosimeters designed to be worn behind lead glasses, multiplicative factors for various positions of dosimeter were derived in order to account for the differences between the doses measured on the inner side of the glasses and the dose equivalent to the eye lens. The DRFs calculated for the position of a routine dosimeter worn outside lead glasses on the band near the left eye lens are 5.6 and 5.7 for goggles and metallic glasses, respectively, while the DRFs calculated as the ratio of doses to the eyes measured with and without the eyewear are 10.2 and 9.9, respectively. Therefore, for dosimeters routinely used outside lead eyewear, the DRF calculated for the position of the dosimeter should be used. Otherwise, we can anticipate an almost two-fold underestimation of the doses. When the dosimeter is worn behind lead glasses, up to two-fold differences between the dose equivalent to the eye lens and the dose measured at the inner side of the glasses were observed depending on the dosimeter position.
- 26 November 2012
- Published by Wiley in Bioelectromagnetics
- Vol. 34 (4) , 333-336
Combined effect of X‐ray radiation and static magnetic fields on reactive oxygen species in rat lymphocytes in vitro
The aim of this study was to investigate the effect of static magnetic fields (SMF) on reactive oxygen species induced by X‐ray radiation. The experiments were performed on lymphocytes from male albino Wistar rats. After exposure to 3 Gy X‐ray radiation (with a dose rate of 560 mGy/min) the measurement of intracellular reactive oxygen species in lymphocytes, using a fluorescent probe, was done before exposure to the SMF, and after 15 min, 1 and 2 h of exposure to the SMF or a corresponding incubation time. For SMF exposure, 0 mT (50 µT magnetic field induction opposite to the geomagnetic field) and 5 mT fields were chosen. The trend of SMF effects for 0 mT was always opposite that of 5 mT. The first one decreased the rate of fluorescence change, while the latter one increased it. Bioelectromagnetics 34:333–336, 2013.
- 26 November 2012
- Published by Wiley in Bioelectromagnetics
- Vol. 34 (4) , 333-336
Combined effect of X‐ray radiation and static magnetic fields on reactive oxygen species in rat lymphocytes in vitro
The aim of this study was to investigate the effect of static magnetic fields (SMF) on reactive oxygen species induced by X‐ray radiation. The experiments were performed on lymphocytes from male albino Wistar rats. After exposure to 3 Gy X‐ray radiation (with a dose rate of 560 mGy/min) the measurement of intracellular reactive oxygen species in lymphocytes, using a fluorescent probe, was done before exposure to the SMF, and after 15 min, 1 and 2 h of exposure to the SMF or a corresponding incubation time. For SMF exposure, 0 mT (50 µT magnetic field induction opposite to the geomagnetic field) and 5 mT fields were chosen. The trend of SMF effects for 0 mT was always opposite that of 5 mT. The first one decreased the rate of fluorescence change, while the latter one increased it. Bioelectromagnetics 34:333–336, 2013.
- 29 February 2012
- Published by Elsevier in Radiation Measurements
- Vol. 47 (2) , 130-138
A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
- 29 February 2012
- Published by Elsevier in Radiation Measurements
- Vol. 47 (2) , 130-138
A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1210-1215
Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1210-1215
Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1203-1209
Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED project
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1203-1209
Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED project
- 1 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1223-1227
Extremity doses of medical staff involved in interventional radiology and cardiology: Correlations and annual doses (hands and legs)
- 1 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1223-1227
Extremity doses of medical staff involved in interventional radiology and cardiology: Correlations and annual doses (hands and legs)
- 1 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1324-1329
Recommendations to reduce extremity and eye lens doses in interventional radiology and cardiology
- 1 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1324-1329
Recommendations to reduce extremity and eye lens doses in interventional radiology and cardiology