Dariusz Brodecki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dariusz Brodecki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Michal Kaczmarek
Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland
3 shared publications - A. Kasprzak
Institute of Electrical Power Engineering Technical University of Lodz 18/22 Stefanowskiego St. 90-924 Łódź Poland
1 shared publication - Ernest Stano
Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland
1 shared publication M. Orlikowski
Institute of Electrical Power Engineering Technical University of Lodz 18/22 Stefanowskiego St. 90-924 Łódź Poland
1 shared publication- Mateusz Andrychowicz
Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-924 Lodz, Poland
1 shared publication - Pawel Rozga
Lodz University of Technology, Institute of Electrical Power Engineering, Lodz, Poland
1 shared publication
Latest Publications
- Open Access
Transformation of Transient Overvoltages by Inductive Voltage Transformers
Overvoltage transients occur after any type of switching activity in a power network, such as breaker operation, fault occurrence/clearance and rapid load change. This distortion of voltage is transformed to the secondary circuit of a voltage transformer. The maximum values of such impulses may many times exceed the rated value of its secondary voltage. This can lead to malfunction of measuring or protection devices connected to the secondary circuit of a voltage transformer and even their damage. The paper presents the application of determined values of ratio error at harmonics of the inductive voltage of the transformer to predict the value of transformed slow-front transient overvoltage to their secondary circuits. This will help to prevent malfunction of measuring or protection devices connected to the secondary side of the voltage transformer and increase their safety of operation. The inductive voltage transformer equivalent circuit for transformation of higher frequency components of distorted voltage must be extended with internal capacitances of windings. This is caused by the fact that the resonance phenomenon of the slow-front transient overvoltage results from leakage inductance and capacitance of primary winding, not from the magnetic core. Therefore, this behaviour is independent from the value of the applied voltage.
Open AccessTransformation of Transient Overvoltages by Inductive Voltage Transformers
Overvoltage transients occur after any type of switching activity in a power network, such as breaker operation, fault occurrence/clearance and rapid load change. This distortion of voltage is transformed to the secondary circuit of a voltage transformer. The maximum values of such impulses may many times exceed the rated value of its secondary voltage. This can lead to malfunction of measuring or protection devices connected to the secondary circuit of a voltage transformer and even their damage. The paper presents the application of determined values of ratio error at harmonics of the inductive voltage of the transformer to predict the value of transformed slow-front transient overvoltage to their secondary circuits. This will help to prevent malfunction of measuring or protection devices connected to the secondary side of the voltage transformer and increase their safety of operation. The inductive voltage transformer equivalent circuit for transformation of higher frequency components of distorted voltage must be extended with internal capacitances of windings. This is caused by the fact that the resonance phenomenon of the slow-front transient overvoltage results from leakage inductance and capacitance of primary winding, not from the magnetic core. Therefore, this behaviour is independent from the value of the applied voltage.
- Open Access
EMC of Wideband Power Sources
In this paper the results of the EMC tests of the wideband power sources: the PWM-based power source and audio power amplifier are discussed. They are intended to be used to supply the measuring system developed for evaluation of the wideband transformation accuracy of instrument transformers. Therefore, it is required to detect possible interferences that may be caused by the power supply to its operation and that may cause a decrease in its accuracy. The tests concern the conducted emission in the frequencies range from 150 kHz to 30 MHz and the radiated emission in the frequencies range from 30 MHz to 1 GHz. Moreover, the level of conducted disturbances in frequencies range from 100 Hz to 5 kHz generated into the supplying current is measured and the immunity of both wideband power sources to low frequency conductive disturbances in the supplying voltage and current is tested. Then, the voltage gain error and phase shift of the output voltage are measured. The EMC tests of both power sources show lack of compliance with the requirement of the standard IEC 61326-1. However, in system application of the audio power amplifier is possible if required increased immunity to conducted emission of the measuring system is ensured.
Open AccessEMC of Wideband Power Sources
In this paper the results of the EMC tests of the wideband power sources: the PWM-based power source and audio power amplifier are discussed. They are intended to be used to supply the measuring system developed for evaluation of the wideband transformation accuracy of instrument transformers. Therefore, it is required to detect possible interferences that may be caused by the power supply to its operation and that may cause a decrease in its accuracy. The tests concern the conducted emission in the frequencies range from 150 kHz to 30 MHz and the radiated emission in the frequencies range from 30 MHz to 1 GHz. Moreover, the level of conducted disturbances in frequencies range from 100 Hz to 5 kHz generated into the supplying current is measured and the immunity of both wideband power sources to low frequency conductive disturbances in the supplying voltage and current is tested. Then, the voltage gain error and phase shift of the output voltage are measured. The EMC tests of both power sources show lack of compliance with the requirement of the standard IEC 61326-1. However, in system application of the audio power amplifier is possible if required increased immunity to conducted emission of the measuring system is ensured.
- 5 March 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 20-23
Wpływ odkształconego napięcia zasilania na pomiar emisji zaburzeń przewodzonych w świetlówkach kompaktowych
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 March 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 20-23
Wpływ odkształconego napięcia zasilania na pomiar emisji zaburzeń przewodzonych w świetlówkach kompaktowych
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 1 January 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 95 (3) , 22-24
Problems of measurement of radio electric disturbances emitted by LED lamps
The article presents problems related to the measurement methods of radiated radioelectric disturbances emitted by light sources (eg LED) defined by EN55015 standard. Smaller trustworthiness of the use of the CDN method have been noted, which is an alternative method to the methods of measuring emissions in shielded chambers (eg GTEM). Presented are the results of the radiated emission test of selected LED lamps regarding the described problem.
- 1 January 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 95 (3) , 22-24
Problems of measurement of radio electric disturbances emitted by LED lamps
The article presents problems related to the measurement methods of radiated radioelectric disturbances emitted by light sources (eg LED) defined by EN55015 standard. Smaller trustworthiness of the use of the CDN method have been noted, which is an alternative method to the methods of measuring emissions in shielded chambers (eg GTEM). Presented are the results of the radiated emission test of selected LED lamps regarding the described problem.
- 5 November 2015
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 3-5
Kompatybilność Elektromagnetyczna urządzeń PLC
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 November 2015
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 3-5
Kompatybilność Elektromagnetyczna urządzeń PLC
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Application of the noise protection transformer in the measuring system for laboratory studies of the electrical discharge development in liquid dielectrics
A noise protection transformer was used for elimination of the interferences in the control circuit of the flash lamp of a laser used in the measuring system for laboratory studies of the electrical discharge development in liquid dielectrics. The source of conducted disturbances was the lightning generator when it was supplying impulses to the tested electrode setup. Interferences caused release of the flash lamp not in the required time from the moment of discharge initiation, thus registration of the shadowgraph photo was not possible. To explain this phenomena the attenuation of SURGE and BURST transients by the noise protection transformer was tested. In the paper determined transformation properties of tested noise protection transformer for the differential and common mode impulse conducted disturbances are presented and discussed. The analysis confirmed that tested device effectively attenuates SURGE and BURST transients. This explained the increase of the flash lamp control circuit immunity to conducted disturbances.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Application of the noise protection transformer in the measuring system for laboratory studies of the electrical discharge development in liquid dielectrics
A noise protection transformer was used for elimination of the interferences in the control circuit of the flash lamp of a laser used in the measuring system for laboratory studies of the electrical discharge development in liquid dielectrics. The source of conducted disturbances was the lightning generator when it was supplying impulses to the tested electrode setup. Interferences caused release of the flash lamp not in the required time from the moment of discharge initiation, thus registration of the shadowgraph photo was not possible. To explain this phenomena the attenuation of SURGE and BURST transients by the noise protection transformer was tested. In the paper determined transformation properties of tested noise protection transformer for the differential and common mode impulse conducted disturbances are presented and discussed. The analysis confirmed that tested device effectively attenuates SURGE and BURST transients. This explained the increase of the flash lamp control circuit immunity to conducted disturbances.
- Open Access
- 1 December 2011
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 59 (4) , 551-554
Operation of voltage transformer in grids with distorted signals
Operation of voltage transformer in grids with distorted signals: Non-sinusoidal currents and voltages caused by nonlinear loads appear in power grids more and more frequently. Determination of the voltage transformer accuracy in such conditions makes a problem. Firstly, due to lack of definition of errors for distorted signals and secondly, typical measurement bridges do not accept higher harmonics. In the paper, the new definition of transformation error for distorted voltages has been proposed and some measurement results have been presented.
- 1 December 2011
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 59 (4) , 551-554
Open AccessOperation of voltage transformer in grids with distorted signals
Operation of voltage transformer in grids with distorted signals: Non-sinusoidal currents and voltages caused by nonlinear loads appear in power grids more and more frequently. Determination of the voltage transformer accuracy in such conditions makes a problem. Firstly, due to lack of definition of errors for distorted signals and secondly, typical measurement bridges do not accept higher harmonics. In the paper, the new definition of transformation error for distorted voltages has been proposed and some measurement results have been presented.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506647,p. 1-5
Analysis of operation of voltage transformers during interruptions and dips of primary voltage
Short transient states during interruptions and dips of the supply voltage of the voltage transformer are the cause of low power quality and source of impulsive conductive disturbances which are transferred to secondary side of the voltage transformer. Maximal values of these impulses are able to exceed even several times rated rms values of primary and secondary voltages. This may lead to abnormal operation of measuring and protection apparatus connected to the secondary side of voltage transformer or even to their damage. In this article used methods of measurements for calculation of the factor of transfer of impulsive disturbances from primary to secondary sides of voltage transformer are presented as well as results of analysis of the influence of construction parameters of windings and their operation conditions on the amount and quality of this transfer.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506647,p. 1-5
Analysis of operation of voltage transformers during interruptions and dips of primary voltage
Short transient states during interruptions and dips of the supply voltage of the voltage transformer are the cause of low power quality and source of impulsive conductive disturbances which are transferred to secondary side of the voltage transformer. Maximal values of these impulses are able to exceed even several times rated rms values of primary and secondary voltages. This may lead to abnormal operation of measuring and protection apparatus connected to the secondary side of voltage transformer or even to their damage. In this article used methods of measurements for calculation of the factor of transfer of impulsive disturbances from primary to secondary sides of voltage transformer are presented as well as results of analysis of the influence of construction parameters of windings and their operation conditions on the amount and quality of this transfer.