Sung Yul Chu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sung Yul Chu has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Tae Kuk Ko
School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
4 shared publicationsKi Sung Chang
School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
3 shared publicationsAl-Thaddeus Avestruz
Department of Electrical Engineering and Computer Science, University of Michigan Ann Arbor, Ann Arbor, MI, 48109, USA
2 shared publications- Al-Thaddeus Avestruz
Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, USA
2 shared publications J.B. Na
2 shared publicationsK.S. Chang
School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (2) , 1244-1271
Transfer-Power Measurement Using a Non-Contact Method for Fair and Accurate Metering of Wireless Power Transfer in Electric Vehicles
Wireless power transfer (WPT) is emerging as the preeminent way to charge electric vehicles, but there appears to be no fair way to measure the power transfer. In this article, Faraday coil transfer-power measurement (FC-TPM) is presented. FC-TPM employs non-contact, open-circuited sense coils to measure the electromagnetic field from WPT and calculates the real power propagating through the air gap between the transmitter and receiver coils. What is measured is the real electromagnetic power, representing the pure dispensation of energy that unambiguously demarcates the losses on either side. FC-TPM was demonstrated to be 0.1% accurate in hardware over an Rx coil misalignment of up to 10 cm using a 1-kW WPT system. Fair metering incentivizes businesses and individuals to make choices that conserve energy and advance technology by providing more information and by properly assigning the financial loss. This article is accompanied by a video highlighting the essential contributions of this article.
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (2) , 1244-1271
Open AccessTransfer-Power Measurement Using a Non-Contact Method for Fair and Accurate Metering of Wireless Power Transfer in Electric Vehicles
Wireless power transfer (WPT) is emerging as the preeminent way to charge electric vehicles, but there appears to be no fair way to measure the power transfer. In this article, Faraday coil transfer-power measurement (FC-TPM) is presented. FC-TPM employs non-contact, open-circuited sense coils to measure the electromagnetic field from WPT and calculates the real power propagating through the air gap between the transmitter and receiver coils. What is measured is the real electromagnetic power, representing the pure dispensation of energy that unambiguously demarcates the losses on either side. FC-TPM was demonstrated to be 0.1% accurate in hardware over an Rx coil misalignment of up to 10 cm using a 1-kW WPT system. Fair metering incentivizes businesses and individuals to make choices that conserve energy and advance technology by providing more information and by properly assigning the financial loss. This article is accompanied by a video highlighting the essential contributions of this article.
- Open Access
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (1) , 100-113
Electromagnetic Model-Based Foreign Object Detection for Wireless Power Transfer
Foreign objects near wireless power transfer (WPT) systems are fire hazards that must be detected. In this article, a new accurate method is presented for foreign object detection based on an electromagnetic model for WPT. Foreign objects are detected by quantifying the deviation from a normal model. This deviation is caused by the foreign object's additional electromagnetic coupling. Advantages of this new method include invariance to receiver coil misalignment, and power level, allowing low-power detection prior to startup. Electromagnetic model-based foreign object detection was demonstrated in hardware to detect a 2 cm diameter U.S. nickel coin, a small disposable lighter, and a saline proxy for a living animal in a kilowatt-level wireless power transfer system, using a prestartup power of only 7 W. Furthermore, foreign objects can be detected regardless of an Rx coil misalignment of up to 10 cm. This article is accompanied by an instructional video.
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (1) , 100-113
Open AccessElectromagnetic Model-Based Foreign Object Detection for Wireless Power Transfer
Foreign objects near wireless power transfer (WPT) systems are fire hazards that must be detected. In this article, a new accurate method is presented for foreign object detection based on an electromagnetic model for WPT. Foreign objects are detected by quantifying the deviation from a normal model. This deviation is caused by the foreign object's additional electromagnetic coupling. Advantages of this new method include invariance to receiver coil misalignment, and power level, allowing low-power detection prior to startup. Electromagnetic model-based foreign object detection was demonstrated in hardware to detect a 2 cm diameter U.S. nickel coin, a small disposable lighter, and a saline proxy for a living animal in a kilowatt-level wireless power transfer system, using a prestartup power of only 7 W. Furthermore, foreign objects can be detected regardless of an Rx coil misalignment of up to 10 cm. This article is accompanied by an instructional video.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Accurate Transfer-Power Measurement for Wireless Charging of Electric Vehicles Under Misalignment
Transfer-power measurement (TPM) provides fair metering for wireless power transfer (WPT) in electric vehicles (EVs). TPM employs sense coils between the transmitter coils (Tx) and receiver coils (Rx) to estimate the transferred power from the magnetic field. Two sense coils are enough for power estimation when the transmitter and receiver positions are always fixed. However, misalignment of coils leads to errors which can be corrected by using more sense coils. In this paper, TPM under misalignment using multiple sense coils is introduced, which give implicit information about the misalignment. A quadratic approximation of coupling coefficients under misalignment is used to correct the errors. Numerical models from precise theory confirm the fidelity of the approximation and experimental results concur.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Accurate Transfer-Power Measurement for Wireless Charging of Electric Vehicles Under Misalignment
Transfer-power measurement (TPM) provides fair metering for wireless power transfer (WPT) in electric vehicles (EVs). TPM employs sense coils between the transmitter coils (Tx) and receiver coils (Rx) to estimate the transferred power from the magnetic field. Two sense coils are enough for power estimation when the transmitter and receiver positions are always fixed. However, misalignment of coils leads to errors which can be corrected by using more sense coils. In this paper, TPM under misalignment using multiple sense coils is introduced, which give implicit information about the misalignment. A quadratic approximation of coupling coefficients under misalignment is used to correct the errors. Numerical models from precise theory confirm the fidelity of the approximation and experimental results concur.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-8
Transfer-power measurement: A non-contact method for fair and accurate metering of wireless power transfer in electric vehicles
Wireless power transfer is emerging as the preeminent way to charge electric vehicles, but there appears to be no fair way to measure power transfer. In this paper, transfer-power measurement (TPM) is introduced. TPM employs non-contact sensing elements to measure magnetic field from wireless power transfer and calculate the real power propagating through space. TPM provides fair metering because individual losses from the transmitter and receiver are disaggregated. Signal and data processing as well as a calibration method are discussed. Experimental results demonstrate a fair method of metering the real transfer power with low estimation error. Fair metering incentivizes businesses and individuals to make choices that conserve energy and advance technology by providing more information and by properly assigning the financial loss.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-8
Transfer-power measurement: A non-contact method for fair and accurate metering of wireless power transfer in electric vehicles
Wireless power transfer is emerging as the preeminent way to charge electric vehicles, but there appears to be no fair way to measure power transfer. In this paper, transfer-power measurement (TPM) is introduced. TPM employs non-contact sensing elements to measure magnetic field from wireless power transfer and calculate the real power propagating through space. TPM provides fair metering because individual losses from the transmitter and receiver are disaggregated. Signal and data processing as well as a calibration method are discussed. Experimental results demonstrate a fair method of metering the real transfer power with low estimation error. Fair metering incentivizes businesses and individuals to make choices that conserve energy and advance technology by providing more information and by properly assigning the financial loss.
- 5 April 2016
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
A Feasibility Demonstration of a Sensing Control Unit for Measurement of Large Capacitance for Particulate Matter Sensor
On-board diagnostics (OBD) of diesel vehicles require various sensors to detect system malfunctions. The Particulate Matter (PM) sensor is one of OBD devices which gather information which could be critical in determining a crack in the diesel particulate filters (DPFs). The PM sensor detects PM which penetrates cracked DPFs and converts the amount of PM into electrical values. The PM sensor control unit (SCU) receives those analog signals and converts them to digital values through hardware and software solutions. A capacitive sensing method would be a stable solution because it detects not raw analog signals but electrical charges or a time constant going through the capacitive load. Therefore, amount of PM would be converted reasonable value of capacitance even though there is a little amount of PM. Naturally, it is beneficial to have a wide range of capacitive variances of sensors but, commercial capacitance-to-digital converter(CDC) integrated circuits (ICs) are focused on the touch-pad industries in which a few pF-order capacitances are enough.This paper presents the feasibility of a large capacitive (generally having hundreds of picofarad (pF)) SCU. We have used hardware (H/W) systems with amplifying the CDC IC's capacitive input range to hundreds of pF-order capacitance input. Verification tests were performed to the capacitance limits by comparing input value, measured value, root mean square (RMS) noise and peak-to-peak noise of each case. After the verification, we demonstrated the feasibility of the control unit as a PM SCU with a capacitive measuring method. Experiments were conducted with the real engine test bed (ETB) generating PM which penetrated the cracked DPFs. PM SCU measured capacitive variance from the PM sensing electrodes and processed the capacitance digital value to the microcontroller (MCU) of the SCU.
- 5 April 2016
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
A Feasibility Demonstration of a Sensing Control Unit for Measurement of Large Capacitance for Particulate Matter Sensor
On-board diagnostics (OBD) of diesel vehicles require various sensors to detect system malfunctions. The Particulate Matter (PM) sensor is one of OBD devices which gather information which could be critical in determining a crack in the diesel particulate filters (DPFs). The PM sensor detects PM which penetrates cracked DPFs and converts the amount of PM into electrical values. The PM sensor control unit (SCU) receives those analog signals and converts them to digital values through hardware and software solutions. A capacitive sensing method would be a stable solution because it detects not raw analog signals but electrical charges or a time constant going through the capacitive load. Therefore, amount of PM would be converted reasonable value of capacitance even though there is a little amount of PM. Naturally, it is beneficial to have a wide range of capacitive variances of sensors but, commercial capacitance-to-digital converter(CDC) integrated circuits (ICs) are focused on the touch-pad industries in which a few pF-order capacitances are enough.This paper presents the feasibility of a large capacitive (generally having hundreds of picofarad (pF)) SCU. We have used hardware (H/W) systems with amplifying the CDC IC's capacitive input range to hundreds of pF-order capacitance input. Verification tests were performed to the capacitance limits by comparing input value, measured value, root mean square (RMS) noise and peak-to-peak noise of each case. After the verification, we demonstrated the feasibility of the control unit as a PM SCU with a capacitive measuring method. Experiments were conducted with the real engine test bed (ETB) generating PM which penetrated the cracked DPFs. PM SCU measured capacitive variance from the PM sensing electrodes and processed the capacitance digital value to the microcontroller (MCU) of the SCU.
- 1 November 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1581-1585
Experimental study on the lightning impulse dielectric strength of liquid nitrogen insulation medium according to various pressures
- 1 November 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1581-1585
Experimental study on the lightning impulse dielectric strength of liquid nitrogen insulation medium according to various pressures
- 1 November 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1501-1505
Design, manufacture and performance evaluation of HTS electromagnets for the hybrid magnetic levitation system
- 1 November 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1501-1505
Design, manufacture and performance evaluation of HTS electromagnets for the hybrid magnetic levitation system
- 28 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1246-1249
Operating Characteristics of Oval-Shaped Resistive Superconducting Fault Current Limiter
In order to limit fault current from an accident in power grid, many research groups have developed resistive superconducting fault current limiters (SFCLs) with a bifilar solenoid and a bifilar pancake types. Comparing with a bifilar solenoid type, a bifilar pancake type has the advantage of its volume, but it has problems such as recovery and insulation of SFCLs. To eliminate the drawback of these two types, in this paper, a new type of coil that is an oval-shaped SFCL, have proposed. This type consists of inner and outer layers which are connected in parallel. A small-scale sample coil was fabricated and experiments for both a short circuit test and recovery characteristic test were performed in liquid nitrogen. Experimental results were compared with two types of coils; the bifilar solenoid and bifilar pancake coil. Consequently, we confirmed the feasibility of an oval-shaped type.
- 28 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1246-1249
Operating Characteristics of Oval-Shaped Resistive Superconducting Fault Current Limiter
In order to limit fault current from an accident in power grid, many research groups have developed resistive superconducting fault current limiters (SFCLs) with a bifilar solenoid and a bifilar pancake types. Comparing with a bifilar solenoid type, a bifilar pancake type has the advantage of its volume, but it has problems such as recovery and insulation of SFCLs. To eliminate the drawback of these two types, in this paper, a new type of coil that is an oval-shaped SFCL, have proposed. This type consists of inner and outer layers which are connected in parallel. A small-scale sample coil was fabricated and experiments for both a short circuit test and recovery characteristic test were performed in liquid nitrogen. Experimental results were compared with two types of coils; the bifilar solenoid and bifilar pancake coil. Consequently, we confirmed the feasibility of an oval-shaped type.
- 30 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1560-1563
Conceptual Design for HTS Coil in Superconducting Electromagnet for Maglev
This study deals with a conceptual design for a high temperature superconductor (HTS) coil fabricated with YBCO wire in a prototype HTS-electromagnet (HTS-EM) model for the electromagnetic suspension (EMS)-based Maglev. Because the size of the HTS coil and the power it consumes during operation are very critical factors in designing the HTS-EM, we focused on the number of coil turns and the operating conditions needed to generate the required magneto-motive force (MMF) effectively. The winding geometry of the sample HTS coil with the largest Ic value was selected for use in this study. To determine the operating condition corresponding to the number of coil turns, we produced the operating profile for the load current of DC current source and the Ic value of HTS coil. From the profile, the optimal number of coil turns to minimize the operating power is determined to be in the range of 1200 to 1400 turns. And the HTS coil should be operated with the current of 37 to 43 A at the cooling temperature of 73 to 76 K.
- 30 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1560-1563
Conceptual Design for HTS Coil in Superconducting Electromagnet for Maglev
This study deals with a conceptual design for a high temperature superconductor (HTS) coil fabricated with YBCO wire in a prototype HTS-electromagnet (HTS-EM) model for the electromagnetic suspension (EMS)-based Maglev. Because the size of the HTS coil and the power it consumes during operation are very critical factors in designing the HTS-EM, we focused on the number of coil turns and the operating conditions needed to generate the required magneto-motive force (MMF) effectively. The winding geometry of the sample HTS coil with the largest Ic value was selected for use in this study. To determine the operating condition corresponding to the number of coil turns, we produced the operating profile for the load current of DC current source and the Ic value of HTS coil. From the profile, the optimal number of coil turns to minimize the operating power is determined to be in the range of 1200 to 1400 turns. And the HTS coil should be operated with the current of 37 to 43 A at the cooling temperature of 73 to 76 K.
- 17 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 2992-2996
Experimental Analysis of Unequal Voltage Distribution on a Single YBCO Coated Conductor Affected by Inhomogeneous Critical Currents in Liquid Nitrogen and Sub-Cooled Liquid Nitrogen
To design a large scale superconducting fault current limiter (SFCL) for power grids, a single long-length YBCO coated conductor (CC) wire is preferred. However this single YBCO CC wire can cause a problem of unequal voltage distribution between the parts on the long wire at quench by the faults. Inhomogeneous critical current of the YBCO CCs in the SFCL is a possibility. Furthermore, sub-cooled liquid nitrogen (LN2) condition is usually used to increase current capacity of the SFCL. However, this sub-cooled condition can worsen the inhomogeneity between the YBCO CCs. Therefore, it is important to understand the relation between the unequal voltage distribution and the inhomogeneous critical currents in the single long length YBCO CC. In this paper, experiments with the same single YBCO CC wire were conducted in various temperature conditions, LN2 and sub-cooled LN2 . In both experiments, the critical currents and voltage distributions generated by faults at short-circuit tests were measured. It was observed that the inhomogeneous condition impacts on the unequal voltage distribution.
- 17 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 2992-2996
Experimental Analysis of Unequal Voltage Distribution on a Single YBCO Coated Conductor Affected by Inhomogeneous Critical Currents in Liquid Nitrogen and Sub-Cooled Liquid Nitrogen
To design a large scale superconducting fault current limiter (SFCL) for power grids, a single long-length YBCO coated conductor (CC) wire is preferred. However this single YBCO CC wire can cause a problem of unequal voltage distribution between the parts on the long wire at quench by the faults. Inhomogeneous critical current of the YBCO CCs in the SFCL is a possibility. Furthermore, sub-cooled liquid nitrogen (LN2) condition is usually used to increase current capacity of the SFCL. However, this sub-cooled condition can worsen the inhomogeneity between the YBCO CCs. Therefore, it is important to understand the relation between the unequal voltage distribution and the inhomogeneous critical currents in the single long length YBCO CC. In this paper, experiments with the same single YBCO CC wire were conducted in various temperature conditions, LN2 and sub-cooled LN2 . In both experiments, the critical currents and voltage distributions generated by faults at short-circuit tests were measured. It was observed that the inhomogeneous condition impacts on the unequal voltage distribution.