Augusto Juste-Dolz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Augusto Juste-Dolz has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Ángel Maquieira
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València-Universitat de València, Camino de Vera s/n, E46022, Valencia, Spain; Departamento de Química, Universitat Politècnica de València, Camino de Vera s/n, E46022, Valencia, Spain
5 shared publications - David Giménez-Romero
Departamento de Química-Física, Universitat de València, Av. Vicent Andrés Estellés 19, 46100, Burjassot, Spain., Spain
3 shared publications - Román Fernández
Center for Research and Innovation in Bioengineering (Ci2B), Universitat Politècnica de València, València, Spain and with Advanced Wave Sensors S.L., Paterna, València, Spain
3 shared publications - Estrella Fernández
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, 46022 Valencia, Spain
2 shared publications - José Luis Cruz
Universitat de València
2 shared publications - Martina Delgado-Pinar
Universitat de València
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Coupled Thickness Shear Mode Resonators for Robust Differential and Multiplexed Acoustic Biosensing
Acoustic biosensors in liquid media are vulnerable to environmental perturbations that degrade frequency stability and detection resolution. Quartz crystal microbalance (QCM), the benchmark acoustic sensing technology, relies on single-resonator frequency shifts and is therefore sensitive to temperature and flow variations, often requiring external reference channels that add system complexity Here, we evaluate Coupled Thickness Shear Mode (CTSM) resonators as an intrinsically differential acoustic architecture and benchmark their performance against conventional QCM sensors. CTSM devices integrate two weakly coupled thickness-shear resonators within a single quartz substrate, in which asymmetric loading redistributes vibrational energy between coupled modes. This approach provides differential readout (ΔG) while retaining access to the resonance frequency measurement (fs1, fs2). Using a BSA-biotin/Neutravidin model system, CTSM achieves limits of detection (0.78 µg·mL⁻¹) comparable to QCM (0.63 µg·mL⁻¹), while demonstrating improved robustness against temperature and flow perturbations and enhanced long-term stability through intrinsic common-mode rejection. Furthermore, independent functionalization of each resonator enables dual-analyte discrimination within a single sensor, as demonstrated using mixtures of anti-OXA and anti-VIM antibodies on resonators functionalized with the corresponding clinically relevant OXA and VIM carbapenemases associated with antimicrobial resistance. These capabilities are achieved without increasing device footprint or duplicating electronics, as both resonators operate through a single electrical interface. Together, these results position CTSM as a compact, differential, and multiplexed acoustic platform for robust biosensing in liquid environments.
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCoupled Thickness Shear Mode Resonators for Robust Differential and Multiplexed Acoustic Biosensing
Acoustic biosensors in liquid media are vulnerable to environmental perturbations that degrade frequency stability and detection resolution. Quartz crystal microbalance (QCM), the benchmark acoustic sensing technology, relies on single-resonator frequency shifts and is therefore sensitive to temperature and flow variations, often requiring external reference channels that add system complexity Here, we evaluate Coupled Thickness Shear Mode (CTSM) resonators as an intrinsically differential acoustic architecture and benchmark their performance against conventional QCM sensors. CTSM devices integrate two weakly coupled thickness-shear resonators within a single quartz substrate, in which asymmetric loading redistributes vibrational energy between coupled modes. This approach provides differential readout (ΔG) while retaining access to the resonance frequency measurement (fs1, fs2). Using a BSA-biotin/Neutravidin model system, CTSM achieves limits of detection (0.78 µg·mL⁻¹) comparable to QCM (0.63 µg·mL⁻¹), while demonstrating improved robustness against temperature and flow perturbations and enhanced long-term stability through intrinsic common-mode rejection. Furthermore, independent functionalization of each resonator enables dual-analyte discrimination within a single sensor, as demonstrated using mixtures of anti-OXA and anti-VIM antibodies on resonators functionalized with the corresponding clinically relevant OXA and VIM carbapenemases associated with antimicrobial resistance. These capabilities are achieved without increasing device footprint or duplicating electronics, as both resonators operate through a single electrical interface. Together, these results position CTSM as a compact, differential, and multiplexed acoustic platform for robust biosensing in liquid environments.
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25541-25549
A Differential Mass Sensor Based on Two Weakly Coupled Thickness Shear Resonators
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25541-25549
Open AccessA Differential Mass Sensor Based on Two Weakly Coupled Thickness Shear Resonators
- Open Access
- 16 June 2026
- Published by Elsevier in SSRN Electronic Journal
Acoustic signatures uncover multistage mechanical maturation of bacterial biofilms
Bacterial biofilm formation is commonly viewed as a gradual increase in surface-bound biomass;however, the mechanical transitions that govern maturation remain insufficiently characterized.Here, we integrate quartz crystal microbalance with dissipation monitoring (QCM-D),field-emission scanning electron microscopy (FESEM), and bulk biofilm assays to investigatethe multistage mechanical development of bacterial biofilms using a controlled heterologousexpression platform for the Pseudomonas aeruginosa adhesin CdrA. This protein enhancesbiomass accumulation while accelerating structural and mechanical biofilm maturation. QCMDmeasurements reveal discrete mechanical regimes, culminating in a concentration-dependentinversion of acoustic harmonics associated with the emergence of a mechanically cohesive viscoelasticfilm. This inversion is not observed in the absence of CdrA induction. FESEM imagingdemonstrates that mechanical consolidation coincides with reduced spatial heterogeneity andincreased structural connectivity. These findings support acoustic harmonic inversion as a robustindicator of late-stage mechanical maturation and highlight combined acoustic and structuralimaging as a powerful experimental approach for studying biofilm integrity and mechanicallyrelevant transitions during biofilm development.
- 16 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAcoustic signatures uncover multistage mechanical maturation of bacterial biofilms
Bacterial biofilm formation is commonly viewed as a gradual increase in surface-bound biomass;however, the mechanical transitions that govern maturation remain insufficiently characterized.Here, we integrate quartz crystal microbalance with dissipation monitoring (QCM-D),field-emission scanning electron microscopy (FESEM), and bulk biofilm assays to investigatethe multistage mechanical development of bacterial biofilms using a controlled heterologousexpression platform for the Pseudomonas aeruginosa adhesin CdrA. This protein enhancesbiomass accumulation while accelerating structural and mechanical biofilm maturation. QCMDmeasurements reveal discrete mechanical regimes, culminating in a concentration-dependentinversion of acoustic harmonics associated with the emergence of a mechanically cohesive viscoelasticfilm. This inversion is not observed in the absence of CdrA induction. FESEM imagingdemonstrates that mechanical consolidation coincides with reduced spatial heterogeneity andincreased structural connectivity. These findings support acoustic harmonic inversion as a robustindicator of late-stage mechanical maturation and highlight combined acoustic and structuralimaging as a powerful experimental approach for studying biofilm integrity and mechanicallyrelevant transitions during biofilm development.
- Open Access
- 10 June 2024
- Published by Forschungsgesellschaft für Arbeitsphysiologie und Arbeitsschutz e.V. in EXCLI Journal
- Vol. 23, 888-903
Unveiling the Ro60-Ro52 complex
The coexistence within a subcellular complex of inter-cellular proteins Ro60, responsible for preserving ncRNA quality, and Ro52, involved in intracellular proteolysis, has been a subject of ongoing debate. Employing molecular docking in tandem with experimental methods like Quartz Crystal Microbalance with Dissipation (QCM-D), Proximity Ligation Assay (PLA), and Indirect Immunofluorescence (IIF), we reveal the presence of Ro60 associating with Ro52 within the cytoplasm. This result unveils the formation of a weak transient complex with a Ka ≈ (3.7 ± 0.3) x 106 M-1, where the toroid-shaped Ro60 structure interacts with the Ro52’s Fc receptor, aligning horizontally within the PRY-SPRY domains of the Ro52’s homodimer. The stability of this complex relies on the interaction between Ro52 chain A and specific Ro60 residues, such as K133, W177, or L185, vital in the Ro60-YRNA bond. These findings bridge the role of Ro60 in YRNA management with Ro52's function in intracellular proteolysis, emphasizing the potential impact of transient complexes on cellular pathways.
- 10 June 2024
- Published by Forschungsgesellschaft für Arbeitsphysiologie und Arbeitsschutz e.V. in EXCLI Journal
- Vol. 23, 888-903
Open AccessUnveiling the Ro60-Ro52 complex
The coexistence within a subcellular complex of inter-cellular proteins Ro60, responsible for preserving ncRNA quality, and Ro52, involved in intracellular proteolysis, has been a subject of ongoing debate. Employing molecular docking in tandem with experimental methods like Quartz Crystal Microbalance with Dissipation (QCM-D), Proximity Ligation Assay (PLA), and Indirect Immunofluorescence (IIF), we reveal the presence of Ro60 associating with Ro52 within the cytoplasm. This result unveils the formation of a weak transient complex with a Ka ≈ (3.7 ± 0.3) x 106 M-1, where the toroid-shaped Ro60 structure interacts with the Ro52’s Fc receptor, aligning horizontally within the PRY-SPRY domains of the Ro52’s homodimer. The stability of this complex relies on the interaction between Ro52 chain A and specific Ro60 residues, such as K133, W177, or L185, vital in the Ro60-YRNA bond. These findings bridge the role of Ro60 in YRNA management with Ro52's function in intracellular proteolysis, emphasizing the potential impact of transient complexes on cellular pathways.
- Open Access
- 18 October 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 287, 09015
Microstructured molecular BIO-gratings by means of UV induced denaturation - INVITED
Rapid, reliable and low cost techniques to fabricate biosensors is a hot topic nowadays. Here, we present a BIO-grating fabricated by means of local, selective denaturing of molecules using UV radiation. A phase-mask is used to generate an interferometric pattern of 1420 nm pitch that, when illuminating a biolayer of BSA molecules lead to its periodic deactivation. After the biorecognition of the specific antibody, aBSA, a BIO-grating is generated due to the height difference between the protein, and the complex protein + antibody. We present the optimization of the fabrication of the BIO-gratings and their AFM characterization. Also, the biosensor performance in terms of limit of detection and limit of quantification will be presented.
- 18 October 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 287, 09015
Open AccessMicrostructured molecular BIO-gratings by means of UV induced denaturation - INVITED
Rapid, reliable and low cost techniques to fabricate biosensors is a hot topic nowadays. Here, we present a BIO-grating fabricated by means of local, selective denaturing of molecules using UV radiation. A phase-mask is used to generate an interferometric pattern of 1420 nm pitch that, when illuminating a biolayer of BSA molecules lead to its periodic deactivation. After the biorecognition of the specific antibody, aBSA, a BIO-grating is generated due to the height difference between the protein, and the complex protein + antibody. We present the optimization of the fabrication of the BIO-gratings and their AFM characterization. Also, the biosensor performance in terms of limit of detection and limit of quantification will be presented.
- Open Access
- 3 January 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (2) , 867-876
Mapping molecular binding by means of conformational dynamics measurements
Protein–protein interactions are key in virtually all biological processes. The study of these interactions and the interfaces that mediate them play a key role in the understanding of biological function. In particular, the observation of protein–protein interactions in their dynamic environment is technically difficult. Here two surface analysis techniques, dual polarization interferometry and quartz crystal microbalance with dissipation monitoring, were paired for real-time mapping of the conformational dynamics of protein–protein interactions. Our approach monitors this dynamics in real time and in situ, which is a great advancement within technological platforms for drug discovery. Results agree with the experimental observations of the interaction between the TRIM21α protein and circulating autoantibodies via a bridging bipolar mechanism. This work provides a new chip-based method to monitor conformational dynamics of protein–protein interactions, which is amenable to miniaturized high-throughput determination.
- 3 January 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (2) , 867-876
Open AccessMapping molecular binding by means of conformational dynamics measurements
Protein–protein interactions are key in virtually all biological processes. The study of these interactions and the interfaces that mediate them play a key role in the understanding of biological function. In particular, the observation of protein–protein interactions in their dynamic environment is technically difficult. Here two surface analysis techniques, dual polarization interferometry and quartz crystal microbalance with dissipation monitoring, were paired for real-time mapping of the conformational dynamics of protein–protein interactions. Our approach monitors this dynamics in real time and in situ, which is a great advancement within technological platforms for drug discovery. Results agree with the experimental observations of the interaction between the TRIM21α protein and circulating autoantibodies via a bridging bipolar mechanism. This work provides a new chip-based method to monitor conformational dynamics of protein–protein interactions, which is amenable to miniaturized high-throughput determination.
- 1 April 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 90, 166-173
Label-free piezoelectric biosensor for prognosis and diagnosis of Systemic Lupus Erythematosus
- 1 April 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 90, 166-173
Label-free piezoelectric biosensor for prognosis and diagnosis of Systemic Lupus Erythematosus