Román Fernández
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Román Fernández has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Arnau
Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, 46022 Valencia, Spain
8 shared publications - Maria Calero
Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, 46022 Valencia, Spain
6 shared publications - Yolanda Jiménez
Universitat Politècnica de València
6 shared publications Antonio Arnau
3 shared publications- Augusto Juste-Dolz
Universitat Politècnica de València
3 shared publications - José Vicente García
Advanced Wave Sensors S.L. Paterna, 46988 Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Coupled Thickness Shear Mode Resonators for Robust Differential and Multiplexed Acoustic Biosensing
Acoustic biosensors in liquid media are vulnerable to environmental perturbations that degrade frequency stability and detection resolution. Quartz crystal microbalance (QCM), the benchmark acoustic sensing technology, relies on single-resonator frequency shifts and is therefore sensitive to temperature and flow variations, often requiring external reference channels that add system complexity Here, we evaluate Coupled Thickness Shear Mode (CTSM) resonators as an intrinsically differential acoustic architecture and benchmark their performance against conventional QCM sensors. CTSM devices integrate two weakly coupled thickness-shear resonators within a single quartz substrate, in which asymmetric loading redistributes vibrational energy between coupled modes. This approach provides differential readout (ΔG) while retaining access to the resonance frequency measurement (fs1, fs2). Using a BSA-biotin/Neutravidin model system, CTSM achieves limits of detection (0.78 µg·mL⁻¹) comparable to QCM (0.63 µg·mL⁻¹), while demonstrating improved robustness against temperature and flow perturbations and enhanced long-term stability through intrinsic common-mode rejection. Furthermore, independent functionalization of each resonator enables dual-analyte discrimination within a single sensor, as demonstrated using mixtures of anti-OXA and anti-VIM antibodies on resonators functionalized with the corresponding clinically relevant OXA and VIM carbapenemases associated with antimicrobial resistance. These capabilities are achieved without increasing device footprint or duplicating electronics, as both resonators operate through a single electrical interface. Together, these results position CTSM as a compact, differential, and multiplexed acoustic platform for robust biosensing in liquid environments.
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCoupled Thickness Shear Mode Resonators for Robust Differential and Multiplexed Acoustic Biosensing
Acoustic biosensors in liquid media are vulnerable to environmental perturbations that degrade frequency stability and detection resolution. Quartz crystal microbalance (QCM), the benchmark acoustic sensing technology, relies on single-resonator frequency shifts and is therefore sensitive to temperature and flow variations, often requiring external reference channels that add system complexity Here, we evaluate Coupled Thickness Shear Mode (CTSM) resonators as an intrinsically differential acoustic architecture and benchmark their performance against conventional QCM sensors. CTSM devices integrate two weakly coupled thickness-shear resonators within a single quartz substrate, in which asymmetric loading redistributes vibrational energy between coupled modes. This approach provides differential readout (ΔG) while retaining access to the resonance frequency measurement (fs1, fs2). Using a BSA-biotin/Neutravidin model system, CTSM achieves limits of detection (0.78 µg·mL⁻¹) comparable to QCM (0.63 µg·mL⁻¹), while demonstrating improved robustness against temperature and flow perturbations and enhanced long-term stability through intrinsic common-mode rejection. Furthermore, independent functionalization of each resonator enables dual-analyte discrimination within a single sensor, as demonstrated using mixtures of anti-OXA and anti-VIM antibodies on resonators functionalized with the corresponding clinically relevant OXA and VIM carbapenemases associated with antimicrobial resistance. These capabilities are achieved without increasing device footprint or duplicating electronics, as both resonators operate through a single electrical interface. Together, these results position CTSM as a compact, differential, and multiplexed acoustic platform for robust biosensing in liquid environments.
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25541-25549
A Differential Mass Sensor Based on Two Weakly Coupled Thickness Shear Resonators
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25541-25549
Open AccessA Differential Mass Sensor Based on Two Weakly Coupled Thickness Shear Resonators
- Open Access
- 16 June 2026
- Published by Elsevier in SSRN Electronic Journal
Acoustic signatures uncover multistage mechanical maturation of bacterial biofilms
Bacterial biofilm formation is commonly viewed as a gradual increase in surface-bound biomass;however, the mechanical transitions that govern maturation remain insufficiently characterized.Here, we integrate quartz crystal microbalance with dissipation monitoring (QCM-D),field-emission scanning electron microscopy (FESEM), and bulk biofilm assays to investigatethe multistage mechanical development of bacterial biofilms using a controlled heterologousexpression platform for the Pseudomonas aeruginosa adhesin CdrA. This protein enhancesbiomass accumulation while accelerating structural and mechanical biofilm maturation. QCMDmeasurements reveal discrete mechanical regimes, culminating in a concentration-dependentinversion of acoustic harmonics associated with the emergence of a mechanically cohesive viscoelasticfilm. This inversion is not observed in the absence of CdrA induction. FESEM imagingdemonstrates that mechanical consolidation coincides with reduced spatial heterogeneity andincreased structural connectivity. These findings support acoustic harmonic inversion as a robustindicator of late-stage mechanical maturation and highlight combined acoustic and structuralimaging as a powerful experimental approach for studying biofilm integrity and mechanicallyrelevant transitions during biofilm development.
- 16 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAcoustic signatures uncover multistage mechanical maturation of bacterial biofilms
Bacterial biofilm formation is commonly viewed as a gradual increase in surface-bound biomass;however, the mechanical transitions that govern maturation remain insufficiently characterized.Here, we integrate quartz crystal microbalance with dissipation monitoring (QCM-D),field-emission scanning electron microscopy (FESEM), and bulk biofilm assays to investigatethe multistage mechanical development of bacterial biofilms using a controlled heterologousexpression platform for the Pseudomonas aeruginosa adhesin CdrA. This protein enhancesbiomass accumulation while accelerating structural and mechanical biofilm maturation. QCMDmeasurements reveal discrete mechanical regimes, culminating in a concentration-dependentinversion of acoustic harmonics associated with the emergence of a mechanically cohesive viscoelasticfilm. This inversion is not observed in the absence of CdrA induction. FESEM imagingdemonstrates that mechanical consolidation coincides with reduced spatial heterogeneity andincreased structural connectivity. These findings support acoustic harmonic inversion as a robustindicator of late-stage mechanical maturation and highlight combined acoustic and structuralimaging as a powerful experimental approach for studying biofilm integrity and mechanicallyrelevant transitions during biofilm development.
- Open Access
- 20 June 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (6) , 433
High Fundamental Frequency (HFF) Monolithic Quartz Crystal Microbalance with Dissipation Array for the Simultaneous Detection of Pesticides and Antibiotics in Complex Food
As in the case of the food industry in general, there is a global concern about safety and quality in complex food matrices, such as honey, which is driving the demand for fast, sensitive and affordable analytical techniques across the honey-packaging industry. Although excellent techniques such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are available, these are located in centralized laboratories and are still lacking in speed, simplicity and cost-effectiveness. Here, a new approach is presented where a competitive immunoassay is combined with a novel High Fundamental Frequency Quartz Crystal Microbalance with Dissipation (HFF-QCMD) array biosensor for the simultaneous detection of antibiotics and pesticides in honey. Concretely, thiabendazole and sulfathiazole residues were monitored in spiked honey samples. Results revealed that HFF-QCMD arrays provide a complementary and reliable tool to LC-MS/MS for the analysis of contaminants in these kinds of complex matrices, while avoiding elaborate sample pre-treatment. The good sensitivity achieved (I50 values in the 70–720 µg/kg range) and the short analysis time (60 min for 24 individual assays), together with the ability for multiple analyte detection (24 sensor array) and its cost-effectiveness, pave the way for the implementation of a fast on-line, in situ routine control of potentially hazardous chemical residues in honey.
- 20 June 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (6) , 433
Open AccessHigh Fundamental Frequency (HFF) Monolithic Quartz Crystal Microbalance with Dissipation Array for the Simultaneous Detection of Pesticides and Antibiotics in Complex Food
As in the case of the food industry in general, there is a global concern about safety and quality in complex food matrices, such as honey, which is driving the demand for fast, sensitive and affordable analytical techniques across the honey-packaging industry. Although excellent techniques such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are available, these are located in centralized laboratories and are still lacking in speed, simplicity and cost-effectiveness. Here, a new approach is presented where a competitive immunoassay is combined with a novel High Fundamental Frequency Quartz Crystal Microbalance with Dissipation (HFF-QCMD) array biosensor for the simultaneous detection of antibiotics and pesticides in honey. Concretely, thiabendazole and sulfathiazole residues were monitored in spiked honey samples. Results revealed that HFF-QCMD arrays provide a complementary and reliable tool to LC-MS/MS for the analysis of contaminants in these kinds of complex matrices, while avoiding elaborate sample pre-treatment. The good sensitivity achieved (I50 values in the 70–720 µg/kg range) and the short analysis time (60 min for 24 individual assays), together with the ability for multiple analyte detection (24 sensor array) and its cost-effectiveness, pave the way for the implementation of a fast on-line, in situ routine control of potentially hazardous chemical residues in honey.
- Open Access
A Real-Time Method for Improving Stability of Monolithic Quartz Crystal Microbalance Operating under Harsh Environmental Conditions
Monolithic quartz crystal microbalance (MQCM) has recently emerged as a very promising technology suitable for biosensing applications. These devices consist of an array of miniaturized QCM sensors integrated within the same quartz substrate capable of detecting multiple target analytes simultaneously. Their relevant benefits include high throughput, low cost per sensor unit, low sample/reagent consumption and fast sensing response. Despite the great potential of MQCM, unwanted environmental factors (e.g., temperature, humidity, vibrations, or pressure) and perturbations intrinsic to the sensor setup (e.g., mechanical stress exerted by the measurement cell or electronic noise of the characterization system) can affect sensor stability, masking the signal of interest and degrading the limit of detection (LoD). Here, we present a method based on the discrete wavelet transform (DWT) to improve the stability of the resonance frequency and dissipation signals in real time. The method takes advantage of the similarity among the noise patterns of the resonators integrated in an MQCM device to mitigate disturbing factors that impact on sensor response. Performance of the method is validated by studying the adsorption of proteins (neutravidin and biotinylated albumin) under external controlled factors (temperature and pressure/flow rate) that simulate unwanted disturbances.
Open AccessA Real-Time Method for Improving Stability of Monolithic Quartz Crystal Microbalance Operating under Harsh Environmental Conditions
Monolithic quartz crystal microbalance (MQCM) has recently emerged as a very promising technology suitable for biosensing applications. These devices consist of an array of miniaturized QCM sensors integrated within the same quartz substrate capable of detecting multiple target analytes simultaneously. Their relevant benefits include high throughput, low cost per sensor unit, low sample/reagent consumption and fast sensing response. Despite the great potential of MQCM, unwanted environmental factors (e.g., temperature, humidity, vibrations, or pressure) and perturbations intrinsic to the sensor setup (e.g., mechanical stress exerted by the measurement cell or electronic noise of the characterization system) can affect sensor stability, masking the signal of interest and degrading the limit of detection (LoD). Here, we present a method based on the discrete wavelet transform (DWT) to improve the stability of the resonance frequency and dissipation signals in real time. The method takes advantage of the similarity among the noise patterns of the resonators integrated in an MQCM device to mitigate disturbing factors that impact on sensor response. Performance of the method is validated by studying the adsorption of proteins (neutravidin and biotinylated albumin) under external controlled factors (temperature and pressure/flow rate) that simulate unwanted disturbances.
- 4 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6643-6651
A Fast Method for Monitoring the Shifts in Resonance Frequency and Dissipation of the QCM Sensors of a Monolithic Array in Biosensing Applications
Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a fast method capable of measuring the response of a large number of sensors and/or overtones, with a high time resolution. Our method, which can be implemented in a low-cost readout electronic circuit, is based on the estimation of Δfr (frequency shift) and ΔD (dissipation shift) from measurements of the sensor response obtained at a single driving frequency. By replacing slow fitting procedures with a direct calculation, the time resolution is only limited by the physical characteristics of the sensor (resonance frequency and quality factor), but not by the method itself. Capabilities of the method are demonstrated by monitoring multiple overtones with a single 5 MHz sensor and a Monolithic QCM array comprising 24 50MHz-sensors. Accuracy of the method is validated and compared with the state-of-the-art, as well as with a reference method based on impedance analysis.
- 4 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6643-6651
A Fast Method for Monitoring the Shifts in Resonance Frequency and Dissipation of the QCM Sensors of a Monolithic Array in Biosensing Applications
Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a fast method capable of measuring the response of a large number of sensors and/or overtones, with a high time resolution. Our method, which can be implemented in a low-cost readout electronic circuit, is based on the estimation of Δfr (frequency shift) and ΔD (dissipation shift) from measurements of the sensor response obtained at a single driving frequency. By replacing slow fitting procedures with a direct calculation, the time resolution is only limited by the physical characteristics of the sensor (resonance frequency and quality factor), but not by the method itself. Capabilities of the method are demonstrated by monitoring multiple overtones with a single 5 MHz sensor and a Monolithic QCM array comprising 24 50MHz-sensors. Accuracy of the method is validated and compared with the state-of-the-art, as well as with a reference method based on impedance analysis.
- 7 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
High Fundamental Frequency (HFF) Monolithic Resonator Arrays for Biosensing Applications: Design, Simulations, Experimental Characterization
Miniaturized, high-throughput, cost-effective sensing devices are needed to advance lab-on-a-chip technologies for healthcare, security, environmental monitoring, food safety, and research application. Quartz crystal microbalance with dissipation (QCMD) is a promising technology for the design of such sensing devices, but its applications have been limited, until now, by low throughput and significant costs. In this work, we present the design and characterization of 24-element monolithic QCMD arrays for high-throughput and low-volume sensing applications in liquid. Physical properties such as geometry and roughness, and electrical properties such as resonance frequency, quality factor, spurious mode suppression, and interactions between array elements (crosstalk), are investigated in detail. In particular, we show that the scattering parameter, S21, commonly measured experimentally to investigate crosstalk, contains contributions from the parasitic grounding effects associated with the acquisition circuitry. Finite element method simulations do not take grounding effects into account explicitly. However, these effects can be effectively modelled with appropriate equivalent circuit models, providing clear physical interpretation of the different contributions. We show that our array design avoids unwanted interactions between elements and discuss in detail aspects of measuring these interactions that are often-overlooked.
- 7 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
High Fundamental Frequency (HFF) Monolithic Resonator Arrays for Biosensing Applications: Design, Simulations, Experimental Characterization
Miniaturized, high-throughput, cost-effective sensing devices are needed to advance lab-on-a-chip technologies for healthcare, security, environmental monitoring, food safety, and research application. Quartz crystal microbalance with dissipation (QCMD) is a promising technology for the design of such sensing devices, but its applications have been limited, until now, by low throughput and significant costs. In this work, we present the design and characterization of 24-element monolithic QCMD arrays for high-throughput and low-volume sensing applications in liquid. Physical properties such as geometry and roughness, and electrical properties such as resonance frequency, quality factor, spurious mode suppression, and interactions between array elements (crosstalk), are investigated in detail. In particular, we show that the scattering parameter, S21, commonly measured experimentally to investigate crosstalk, contains contributions from the parasitic grounding effects associated with the acquisition circuitry. Finite element method simulations do not take grounding effects into account explicitly. However, these effects can be effectively modelled with appropriate equivalent circuit models, providing clear physical interpretation of the different contributions. We show that our array design avoids unwanted interactions between elements and discuss in detail aspects of measuring these interactions that are often-overlooked.
- 1 January 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 285, 511-518
OSTEMER polymer as a rapid packaging of electronics and microfluidic system on PCB
- 1 January 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 285, 511-518
OSTEMER polymer as a rapid packaging of electronics and microfluidic system on PCB
- Open Access
Design and Validation of a 150 MHz HFFQCM Sensor for Bio-Sensing Applications
Acoustic wave resonators have become suitable devices for a broad range of sensing applications due to their sensitivity, low cost, and integration capability, which are all factors that meet the requirements for the resonators to be used as sensing elements for portable point of care (PoC) platforms. In this work, the design, characterization, and validation of a 150 MHz high fundamental frequency quartz crystal microbalance (HFF-QCM) sensor for bio-sensing applications are introduced. Finite element method (FEM) simulations of the proposed design are in good agreement with the electrical characterization of the manufactured resonators. The sensor is also validated for bio-sensing applications. For this purpose, a specific sensor cell was designed and manufactured that addresses the critical requirements associated with this type of sensor and application. Due to the small sensing area and the sensor’s fragility, these requirements include a low-volume flow chamber in the nanoliter range, and a system approach that provides the appropriate pressure control for assuring liquid confinement while maintaining the integrity of the sensor with a good base line stability and easy sensor replacement. The sensor characteristics make it suitable for consideration as the elemental part of a sensor matrix in a multichannel platform for point of care applications.
Open AccessDesign and Validation of a 150 MHz HFFQCM Sensor for Bio-Sensing Applications
Acoustic wave resonators have become suitable devices for a broad range of sensing applications due to their sensitivity, low cost, and integration capability, which are all factors that meet the requirements for the resonators to be used as sensing elements for portable point of care (PoC) platforms. In this work, the design, characterization, and validation of a 150 MHz high fundamental frequency quartz crystal microbalance (HFF-QCM) sensor for bio-sensing applications are introduced. Finite element method (FEM) simulations of the proposed design are in good agreement with the electrical characterization of the manufactured resonators. The sensor is also validated for bio-sensing applications. For this purpose, a specific sensor cell was designed and manufactured that addresses the critical requirements associated with this type of sensor and application. Due to the small sensing area and the sensor’s fragility, these requirements include a low-volume flow chamber in the nanoliter range, and a system approach that provides the appropriate pressure control for assuring liquid confinement while maintaining the integrity of the sensor with a good base line stability and easy sensor replacement. The sensor characteristics make it suitable for consideration as the elemental part of a sensor matrix in a multichannel platform for point of care applications.
- 30 March 2012
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 170, 95-103
Optimization of the lateral field excited platform for liquid sensing applications
- 30 March 2012
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 170, 95-103
Optimization of the lateral field excited platform for liquid sensing applications