Yoshiko Iino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yoshiko Iino has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Arata Ebihara
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
2 shared publications - Takashi Okiji
Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan
2 shared publications - Bayan Rashed
Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
1 shared publication - Keiichiro Maki
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
1 shared publication - Moe Sandar Kyaw
Division of Operative Dentistry, Department of Ecological Dentistry, Tohoku University Graduate School of Dentistry, Seiryo-machi, Aoba-ku, Sendai, Miyagi, Japan
1 shared publication - Myint Thu
Department of Materials Science and Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 23 August 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-14
Effect of repetitive up-and-down movements on torque/force generation, surface defects and shaping ability of nickel-titanium rotary instruments: an ex vivo study
The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions. Therefore, this study aimed to examine how repeated up-and-down movements at the working length affect torque/force generation, surface defects, and canal shaping ability of JIZAI and TruNatomy instruments. An original automated root canal instrumentation device was used to prepare canals and to record torque/force changes. The mesial roots of human mandibular molars with approximately 30˚ of canal curvature were selected through geometric matching using micro-computed tomography. The samples were divided into three groups according to the number of up-and-down movements at the working length (1, 3, and 6 times; n = 24 each) and subdivided according to the instruments: JIZAI (#13/0.04 taper, #25/0.04 taper, and #35/0.04 taper) or TruNatomy (#17/0.02 taper, #26/0.04 taper, and #36/0.03 tape) (n = 12 each). The design, surface defects, phase transformation temperatures, nickel-titanium ratios, torque, force, shaping ability, and surface deformation were evaluated. Data were analyzed with the Kruskal-Wallis and Dunn’s tests (α = 0.05). The instruments had different designs and phase transformation temperatures. The 3 and 6 up-and-down movements resulted in a smaller upward force compared to 1 movement (p < 0.05). TruNatomy generated significantly less maximum torque, force, and surface wear than JIZAI (p < 0.05). However, TruNatomy exhibited a larger canal deviation (p < 0.05). No statistical differences in shaping ability were detected between different up-and-down movements. Under laboratory conditions with JIZAI and TruNatomy, a single up-and-down movement at the working length increased the screw-in force of subsequent instruments in severely curved canals in the single-length instrumentation technique. A single up-and-down movement generated more surface defects on the file when using JIZAI. TruNatomy resulted in less stress generation during instrumentation, while JIZAI better maintained the curvature of root canals.
- 23 August 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-14
Open AccessEffect of repetitive up-and-down movements on torque/force generation, surface defects and shaping ability of nickel-titanium rotary instruments: an ex vivo study
The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions. Therefore, this study aimed to examine how repeated up-and-down movements at the working length affect torque/force generation, surface defects, and canal shaping ability of JIZAI and TruNatomy instruments. An original automated root canal instrumentation device was used to prepare canals and to record torque/force changes. The mesial roots of human mandibular molars with approximately 30˚ of canal curvature were selected through geometric matching using micro-computed tomography. The samples were divided into three groups according to the number of up-and-down movements at the working length (1, 3, and 6 times; n = 24 each) and subdivided according to the instruments: JIZAI (#13/0.04 taper, #25/0.04 taper, and #35/0.04 taper) or TruNatomy (#17/0.02 taper, #26/0.04 taper, and #36/0.03 tape) (n = 12 each). The design, surface defects, phase transformation temperatures, nickel-titanium ratios, torque, force, shaping ability, and surface deformation were evaluated. Data were analyzed with the Kruskal-Wallis and Dunn’s tests (α = 0.05). The instruments had different designs and phase transformation temperatures. The 3 and 6 up-and-down movements resulted in a smaller upward force compared to 1 movement (p < 0.05). TruNatomy generated significantly less maximum torque, force, and surface wear than JIZAI (p < 0.05). However, TruNatomy exhibited a larger canal deviation (p < 0.05). No statistical differences in shaping ability were detected between different up-and-down movements. Under laboratory conditions with JIZAI and TruNatomy, a single up-and-down movement at the working length increased the screw-in force of subsequent instruments in severely curved canals in the single-length instrumentation technique. A single up-and-down movement generated more surface defects on the file when using JIZAI. TruNatomy resulted in less stress generation during instrumentation, while JIZAI better maintained the curvature of root canals.
- Open Access
Evaluation of Crack Formation and Propagation with Ultrasonic Root-End Preparation and Obturation Using a Digital Microscope and Optical Coherence Tomography
Objective. This study is aimed at determining (1) the effect of root-end resection, ultrasonic root-end preparation, and root-end filling on the incidence of crack formation and propagation by using a digital microscope (DM) and optical coherence tomography (OCT) and (2) the performance of OCT on the detection of cracks by comparing with microcomputed tomography (micro-CT) as a reference standard. Methodology. Thirty extracted lower incisors were endodontically treated and subjected to root-end resection and ultrasonic root-end cavity preparation. Then, the teeth were divided into three groups (, each), and the root-end cavity was either left unfilled or filled with mineral trioxide aggregate (MTA) or super-EBA. The resected surface was observed with OCT and DM after the root-end resection, ultrasonic root-end preparation, and root-end filling, and the frequency of incomplete and complete cracks were recorded. The observation was repeated after two weeks, one month, and two months, and micro-CT scans after two months were taken as the gold standard. Results. The DM results show dentinal crack formation in 47% of the samples following root-end resection and in 87% following ultrasonic preparation. After the ultrasonic preparation, no existing crack propagated to a complete crack, but new cracks were formed. MTA and super-EBA had no effect on crack formation. The Spearman correlation coefficient between OCT and DM was 0.186 (very weak correlation; ). Sensitivity and specificity in comparison to micro-CT were 0.50 and 0.55 in OCT and 1.00 and 0.35 in DM, respectively. McNemar’s test showed a significant difference between OCT and DM (). Conclusion. Apical resection and ultrasonic preparation could form dentinal cracks. OCT and DM showed different detection frequencies of cracks with very weak correlation. DM showed superior sensitivity compared with OCT.Open AccessEvaluation of Crack Formation and Propagation with Ultrasonic Root-End Preparation and Obturation Using a Digital Microscope and Optical Coherence Tomography
Objective. This study is aimed at determining (1) the effect of root-end resection, ultrasonic root-end preparation, and root-end filling on the incidence of crack formation and propagation by using a digital microscope (DM) and optical coherence tomography (OCT) and (2) the performance of OCT on the detection of cracks by comparing with microcomputed tomography (micro-CT) as a reference standard. Methodology. Thirty extracted lower incisors were endodontically treated and subjected to root-end resection and ultrasonic root-end cavity preparation. Then, the teeth were divided into three groups (, each), and the root-end cavity was either left unfilled or filled with mineral trioxide aggregate (MTA) or super-EBA. The resected surface was observed with OCT and DM after the root-end resection, ultrasonic root-end preparation, and root-end filling, and the frequency of incomplete and complete cracks were recorded. The observation was repeated after two weeks, one month, and two months, and micro-CT scans after two months were taken as the gold standard. Results. The DM results show dentinal crack formation in 47% of the samples following root-end resection and in 87% following ultrasonic preparation. After the ultrasonic preparation, no existing crack propagated to a complete crack, but new cracks were formed. MTA and super-EBA had no effect on crack formation. The Spearman correlation coefficient between OCT and DM was 0.186 (very weak correlation; ). Sensitivity and specificity in comparison to micro-CT were 0.50 and 0.55 in OCT and 1.00 and 0.35 in DM, respectively. McNemar’s test showed a significant difference between OCT and DM (). Conclusion. Apical resection and ultrasonic preparation could form dentinal cracks. OCT and DM showed different detection frequencies of cracks with very weak correlation. DM showed superior sensitivity compared with OCT.