Effect of repetitive up-and-down movements on torque/force generation, surface defects and shaping ability of nickel-titanium rotary instruments: an ex vivo study
Open Access
- 23 August 2024
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-14
Abstract
The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions. Therefore, this study aimed to examine how repeated up-and-down movements at the working length affect torque/force generation, surface defects, and canal shaping ability of JIZAI and TruNatomy instruments. An original automated root canal instrumentation device was used to prepare canals and to record torque/force changes. The mesial roots of human mandibular molars with approximately 30˚ of canal curvature were selected through geometric matching using micro-computed tomography. The samples were divided into three groups according to the number of up-and-down movements at the working length (1, 3, and 6 times; n = 24 each) and subdivided according to the instruments: JIZAI (#13/0.04 taper, #25/0.04 taper, and #35/0.04 taper) or TruNatomy (#17/0.02 taper, #26/0.04 taper, and #36/0.03 tape) (n = 12 each). The design, surface defects, phase transformation temperatures, nickel-titanium ratios, torque, force, shaping ability, and surface deformation were evaluated. Data were analyzed with the Kruskal-Wallis and Dunn’s tests (α = 0.05). The instruments had different designs and phase transformation temperatures. The 3 and 6 up-and-down movements resulted in a smaller upward force compared to 1 movement (p < 0.05). TruNatomy generated significantly less maximum torque, force, and surface wear than JIZAI (p < 0.05). However, TruNatomy exhibited a larger canal deviation (p < 0.05). No statistical differences in shaping ability were detected between different up-and-down movements. Under laboratory conditions with JIZAI and TruNatomy, a single up-and-down movement at the working length increased the screw-in force of subsequent instruments in severely curved canals in the single-length instrumentation technique. A single up-and-down movement generated more surface defects on the file when using JIZAI. TruNatomy resulted in less stress generation during instrumentation, while JIZAI better maintained the curvature of root canals.Keywords
Funding Information
- Tokyo Medical and Dental University (1B223, 1B223, 1B223, 1B223, 1B223, 1B223, 1B223, 1B223)
- Japan Society for the Promotion of Sciences (No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498, No. 19K18987 and No. 20K18498)
This publication has 36 references indexed in Scilit:
- Effect of repetitive pecking at working length for glide path preparation using G-fileRestorative Dentistry & Endodontics, 2015
- ‘Screw‐in’ tendency of rotary nickel–titanium files due to design geometryInternational Endodontic Journal, 2014
- Torque and Force Induced by ProTaper Universal and ProTaper Next during Shaping of Large and Small Root Canals in Extracted TeethJournal of Endodontics, 2014
- Apical Enlargement According to Different Pecking Times at Working Length Using Reciprocating FilesJournal of Endodontics, 2013
- Comparison of Canal Transportation and Changes in Canal Curvature of Two Nickel-Titanium Rotary InstrumentsJournal of Endodontics, 2011
- Heat treatment of nickel-titanium rotary endodontic instruments: effects on bending properties and shaping abilitiesInternational Endodontic Journal, 2011
- Deformation and fracture of RaCe and K3 endodontic instruments according to the number of usesInternational Endodontic Journal, 2006
- Dynamic torque and apical forces of ProFile .04 rotary instruments during preparation of curved canalsInternational Endodontic Journal, 2002
- Effects of four Ni–Ti preparation techniques on root canal geometry assessed by micro computed tomographyInternational Endodontic Journal, 2001
- Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomographyJournal of Endodontics, 1996