CNChristopher J. D. Norley

Christopher J. D. Norley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher J. D. Norley has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 3D‐printed large‐area focused grid for scatter reduction in cone‐beam CT

    by Santiago Fabian Cobos, Christopher James Norley, Hristo Nikolaev Nikolov, David Wayne Holdsworth

    Background: Cone‐beam computed tomography (CBCT) systems acquire volumetric data more efficiently than fan‐beam or multislice CT, particularly when the anatomy of interest resides within the axial field‐of‐view of the detector and data can be acquired in one rotation. For such systems, scattered radiation remains a source of image quality degradation leading to increased noise, image artifacts, and CT number inaccuracies.Purpose: Recent advances in metal additive manufacturing allow the production of highly focused antiscatter grids (2D‐ASGs) that can be used to reduce scatter intensity, while preserving primary radiation transmission. We present the first implementation of a large‐area, 2D‐ASG for flat‐panel CBCT, including grid‐line artifact removal and related improvements in image quality.Methods: A 245 × 194 × 10 mm 2D‐ASG was manufactured from chrome–cobalt alloy using laser powder‐bed fusion (LPBF) (AM‐400; Renishaw plc, New Mills Wotton‐under‐Edge, UK). The 2D‐ASG had a square profile with a pitch of 9.09 lines/cm and 10:1 grid‐ratio. The nominal 0.1 mm grid septa were focused to a 732 mm x‐ray source to optimize primary x‐ray transmission and reduce grid‐line shadowing at the detector. Powder‐bed fusion ensured the structural stability of the ASG with no need for additional interseptal support. The 2D‐ASG was coupled to a 0.139‐mm element pitch flat‐panel detector (DRX 3543, Carestream Health) and proper alignment was confirmed by consistent grid‐line shadow thickness across the whole detector array. A 154‐mm diameter CBCT image‐quality‐assurance phantom was imaged using a rotary stage and a ceiling‐mounted, x‐ray unit (Proteus XR/a, GE Medical Systems, 80kVp, 0.5mAs). Grid‐line artifacts were removed using a combination of exposure‐dependent gain correction and spatial‐frequency, Fourier filtering. Projections were reconstructed using a Parker‐weighted, FDK algorithm and voxels were spatially averaged to 357 × 357 × 595 µm to improve the signal‐to‐noise characteristics of the CBCT reconstruction. Finally, in order to compare image quality with and without scatter, the phantom was scanned again under the same CBCT conditions but with no 2D‐ASG. No additional antiscatter (i.e., air‐gap, bowtie filtration) strategies were used to evaluate the effects in image quality caused by the 2D‐ASG alone.Results: The large‐area, 2D‐ASG prototype was successfully designed and manufactured using LPBF. CBCT image‐quality improvements using the 2D‐ASG included: an overall 14.5% CNR increase across the volume; up to 48.8% CNR increase for low‐contrast inserts inside the contrast plate of the QA phantom; and a 65% reduction of cupping artifact in axial profiles of water‐filled cross sections of the phantom. Advanced image processing strategies to remove grid line artifacts did not affect the spatial resolution or geometric accuracy of the system.Conclusions: LPBF can be used to manufacture highly efficient, 2D‐focused ASGs that can be easily coupled to clinical, flat‐panel detectors. The implementation of ASGs in CBCT leads to reduced scatter‐related artifacts, improved CT number accuracy, and enhanced CNR with no increased equivalent dose to the patient. Further improvements to image quality might be achieved with a combination of scatter‐correction algorithms and iterative‐reconstruction strategies. Finally, clinical applications where other scatter removal strategies are unfeasible might now achieve superior soft‐tissue visualization and quantitative capabilities.


  • Open Access

    High-dynamic-range micro-CT for nondestructive testing of titanium 3D-printed medical components

    by Santiago Fabian Cobos, Christopher James Norley, Steven Ingo Pollmann, David Wayne Holdsworth

    Purpose: Industrial microcomputed tomography (micro-CT) scanners are suitable for nondestructive testing (NDT) of metal, 3D-printed medical components. Typically, these scanners are equipped with high-energy sources that require heavy shielding and costly infrastructure to operate safely, making routine NDT of medical components prohibitively expensive. Alternatively, fixed-current, low-cost x-ray units could be implemented to perform CT-based NDT of 3D-printed medical parts in a subset of cases, if there is sufficient x-ray transmission for the CT reconstruction. A lack of signal—caused by areas of high attenuation in two-dimensional-projection images of metal objects—leads to artifacts that can make an image-based NDT unreliable. We present the implementation of a dual-exposure technique devised to extend the dynamic range (DR) of a commercially available CT scanner equipped with a low-cost low-energy (80 kV) x-ray unit, increasing the signal-to-noise ratio of highly attenuated areas for NDT of 3D-printed medical components.Approach: Our high-dynamic-range CT (HDR-CT) technique adequately combines projection images acquired at two exposure levels by modifying the integration times of each protocol. We evaluate the performance and limitations of this HDR-CT technique by imaging a series of titanium-alloy test-samples. One of the test-samples was a resolution and conspicuity phantom designed to assess the improvements in void visualization of the proposed methodology. The other test-samples were four porous cylinders, 17 × 40 mm, with 60%, 70%, 80%, and 90% nominal internal porosities.Results: Our HDR-CT technique adequately combines projection images acquired at two exposure levels by modifying the integration times of each protocol. Our results demonstrate that the 12-bit native DR of the CT scanner was increased to effective values of between 14 and 16 bits.Conclusions: The HDR-CT reconstructions showed improved contrast-to-noise and void conspicuity, when compared with conventional CT scans. This extension of DR has the potential to improve defect visualization during NDT of medium-size, titanium-alloy, 3D-printed medical components.


  • Keystone predators govern the pathway and pace of climate impacts in a subarctic marine ecosystem

    by Douglas B. Rasher, Robert S. Steneck, Jochen Halfar, Kristy J. Kroeker, Justin B. Ries, M. Tim Tinker, Phoebe T. W. Chan, Jan Fietzke, Nicholas A. Kamenos, Brenda H. Konar, et al.

    Trophic cascades and climate change are together reshaping an iconic kelp forest ecosystem after the loss of sea otters.


  • Activation of cancer-associated fibroblasts is required for tumor neovascularization in a murine model of melanoma

    by James Hutchenreuther, Krista Vincent, Chris Norley, Michael Racanelli, Stephen B. Gruber, Timothy M. Johnson, Douglas R. Fullen, Leon Raskin, Bernard Perbal, David W. Holdsworth, et al.


  • Top Cited Papers
    Open Access

    Early Changes of Articular Cartilage and Subchondral Bone in The DMM Mouse Model of Osteoarthritis

    by Hang Fang, Lisi Huang, Ian Welch, Chris Norley, David W. Holdsworth, Frank Beier, Daozhang Cai

    To examine the early changes of articular cartilage and subchondral bone in the DMM mouse model of osteoarthritis, mice were subjected to DMM or SHAM surgery and sacrificed at 2-, 5- and 10-week post-surgery. Catwalk gait analyses, Micro-Computed Tomography, Toluidine Blue, Picrosirius Red and Tartrate-Resistant Acid Phosphatase (TRAP) staining were used to investigate gait patterns, joint morphology, subchondral bone, cartilage, collagen organization and osteoclasts activity, respectively. Results showed OA progressed over 10-week time-course. Gait disparity occurred only at 10-week post-surgery. Osteophyte formed at 2-week post-surgery. BMDs of DMM showed no statistical differences comparing to SHAM at 2 weeks, but BV/TV is much higher in DMM mice. Increased BMD was clearly found at 5- and 10-week post-surgery in DMM mice. TRAP staining showed increased osteoclast activity at the site of osteophyte formation of DMM joints at 5- and 10-week time points. These results showed that subchondral bone turnover might occurred earlier than 2 weeks in this mouse DMM model. Gait disparity only occurred at later stage of OA in DMM mice. Notably, patella dislocation could occur in some of the DMM mice and cause a different pattern of OA in affected knee.


  • Open Access

    Micro‐computed tomography: Applications for high‐resolution skeletal density determinations: An example using annually banded crustose coralline algae

    by P. Chan, J. Halfar, C. J. D. Norley, S. I. Pollmann, W. Adey, D. W. Holdsworth

    Warming and acidification of the world's oceans are expected to have widespread consequences for marine biodiversity and ecosystem functioning. However, due to the relatively short record of instrumental observations, one has to rely upon geochemical and physical proxy information stored in biomineralized shells and skeletons of calcareous marine organisms as in situ recorders of past environments. Of particular interest is the response of marine calcifiers to ocean acidification through the examination of structural growth characteristics. Here we demonstrate the application of micro‐computed tomography (micro‐CT) for three‐dimensional visualization and analysis of growth, skeletal density, and calcification in a slow‐growing, annually banded crustose coralline alga Clathromorphum nereostratum (increment width ∼380 µm). X‐ray images and time series of skeletal density were generated at 20 µm resolution and rebinned to 40, 60, 80, and 100 µm for comparison in a sensitivity analysis. Calcification rates were subsequently calculated as the product of density and growth (linear extension). While both skeletal density and calcification rates do not significantly differ at varying spatial resolutions (the latter being strongly influenced by growth rates), clear visualization of micron‐scale growth features and the quantification of structural changes on subannual time scales requires higher scanning resolutions. In the present study, imaging at 20 µm resolution reveals seasonal cycles in density that correspond to summer/winter variations in skeletal structure observed using scanning electron microscopy (SEM). Micro‐CT is a fast, nondestructive, and high‐resolution technique for structural and morphometric analyses of temporally banded paleoclimate archives, particularly those that exhibit slow or compressed growth or micron‐scale structures.


  • Open Access

    Micro-CT imaging of live insects using carbon dioxide gas-induced hypoxia as anesthetic with minimal impact on certain subsequent life history traits

    by Danny Poinapen, Joanna K. Konopka, Joseph U. Umoh, Chris J. D. Norley, Jeremy N. McNeil, David W. Holdsworth

    Background: Live imaging of whole invertebrates can be accomplished with X-ray micro-computed tomography (micro-CT) at 10-100 μm spatial resolution. However, image quality could be compromised by the movement of live subjects, producing image artefacts. We tested the feasibility of using CO2 gas to induce temporary full-immobilization of sufficient duration to image live insects based on their ability to tolerate hypoxic conditions. Additionally, we investigated the effects of these prolonged hypoxic conditions on several life history traits of a lepidopteran species. Methods: Live Colorado potato beetle (CPB) and true armyworm (TAW) adults were immobilized under a constant CO2 gas flow (0.5 L/min), and scanned using micro-CT (80 kVp; 450 μA). An L8 (24) orthogonal array (OA) was used to evaluate the effects of prolonged CO2-induced anesthesia on the recovery, longevity, and incidence of mating of TAW adults. The variable factors were age (immature and mature), sex (female and male), exposure time (3 and 7 h), and exposure regime (single and repeated). Results: With this method, successful 3D reconstruction and visualizations of CPB and TAW adults were produced at 20 micron voxel spacing at an acceptable radiation dose and image noise level. From the inverse-square relationship found between the radiation doses and image noise levels, the optimal scanning protocol produced an entrance dose of 6.2 ± 0.04 Gy with images of 129.6 ± 5.1 HU noise level during a 2.7 h scan. Independent OA experiments indicated that CO2 gas did not result in death of exposed TAW adults, except when older males were exposed for longer durations. Exposure time and sex were more influential factors affecting recovery, longevity, and mating success than age and exposure regime following CO2 exposure. Conclusion: We have demonstrated that using CO2 gas during micro-CT imaging effectively induces safe, repeatable, whole-body, and temporary immobilization of live insects for 3D visualizations without motion artefacts. Moreover, we have shown that exposed TAW individuals made a full recovery with very little impact on subsequent longevity, and mating success post hypoxia. This method is applicable to other imaging modalities and could be used for routine exploratory and time-course studies, for repeated scanning of live and intact individuals.


  • Open Access

    Loss of the Mammalian DREAM Complex Deregulates Chondrocyte Proliferation

    by Chantal Forristal, Shauna A. Henley, James I. MacDonald, Jason R. Bush, Carley Ort, Daniel T. Passos, Srikanth Talluri, Charles A. Ishak, Michael J. Thwaites, Chris J. Norley, et al.

    Mammalian DREAM is a conserved protein complex that functions in cellular quiescence. DREAM contains an E2F, a retinoblastoma (RB)-family protein, and the MuvB core (LIN9, LIN37, LIN52, LIN54, and RBBP4). In mammals, MuvB can alternatively bind to BMYB to form a complex that promotes mitotic gene expression. Because BMYB-MuvB is essential for proliferation, loss-of-function approaches to study MuvB have generated limited insight into DREAM function. Here, we report a gene-targeted mouse model that is uniquely deficient for DREAM complex assembly. We have targeted p107 (Rbl1) to prevent MuvB binding and combined it with deficiency for p130 (Rbl2). Our data demonstrate that cells from these mice preferentially assemble BMYB-MuvB complexes and fail to repress transcription. DREAM-deficient mice show defects in endochondral bone formation and die shortly after birth. Micro-computed tomography and histology demonstrate that in the absence of DREAM, chondrocytes fail to arrest proliferation. Since DREAM requires DYRK1A (dual-specificity tyrosine phosphorylation-regulated protein kinase 1A) phosphorylation of LIN52 for assembly, we utilized an embryonic bone culture system and pharmacologic inhibition of (DYRK) kinase to demonstrate a similar defect in endochondral bone growth. This reveals that assembly of mammalian DREAM is required to induce cell cycle exit in chondrocytes.


  • Resolution enhancement of computed radiography images using two orthogonal tilts

    by Steven I. Pollmann, Chris J. D. Norley, Xunhua Yuan, David W. Holdsworth


  • Open Access

    Rapid in vivo whole body composition of rats using cone beam μCT

    by Patrick V. Granton, Chris J. D. Norley, Joseph Umoh, Eva A. Turley, Bruce C. Frier, Earl G. Noble, David W. Holdsworth

    Precise, noninvasive analysis and quantification of in vivo body composition is essential for research involving longitudinal, small-animal disease models. We investigated the feasibility and precision of a rapid, flat-panel μCT scanner to report whole body adipose tissue volume (ATV), lean tissue volume (LTV), skeletal tissue volume (STV), and bone mineral content (BMC) in 25 postmortem female and 52 live male Sprague-Dawley rats. μCT images, acquired in three 90-mm segments and reconstructed with 308 μm of isotropic voxel spacing, formed contiguous image volumes of each entire rat specimen. Three signal-intensity thresholds (determined to be −186, 5, and 155 HU) were used to classify each voxel as adipose, lean, or skeletal tissue, respectively. Tissue masses from the volume fractions of ATV, LTV, and STV were calculated from assumed tissue densities of 0.95, 1.05, and 1.92 g/cm−3, respectively. A CT-derived total mass was calculated for each rat and compared with the gravimetrically measured mass, which differed on average for the postmortem female and the live male group by 2.5 and 1.1%, respectively. To evaluate the accuracy of the CT-derived body composition technique, following the live male study excised muscle tissue in the lower right leg of all rats in group B were compared with the image-derived LT measurement of the same regional compartment and found to differ on average by 2.2%. Through repeated CT measurements of postmortem specimens, the whole body ATV, LTV, STV, and BMC measurement analysis gave a precision value of ±0.6, 1.9, 1.7, and 0.5% of the average value, respectively.