Ildar G. Gilemov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ildar G. Gilemov has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Alexander A. Nikolaev
Nosov Magnitogorsk State Technical University,Automated Electric Drives and Mechatronics Department,Magnitogorsk,Russia
6 shared publications- Alexander Arkadyevich Nikolaev
Nosov Magnitogorsk State Technical University
6 shared publications Michail V. Bulanov
Nosov Magnitogorsk State Technical University,Automated Electric Drives and Mechatronics Department,Magnitogorsk,Russia
4 shared publications- Alexander S. Maklakov
Project Activity Center, Scientific Activity Sector, Moscow Polytechnic University, Bolshaya Semyonovskaya Street 38, 107023 Moscow, Russia
3 shared publications A.A. Nikolaev
Nosov Magnitogorsk Technical State University,Automated Electrical Drive and Mechatronics Dept,Magnitogorsk,Russia
2 shared publications- Alexander S. Denisevich
Research and Development Department, Nosov Magnitogorsk State Technical University, 455000 Magnitogorsk, Russia
2 shared publications
Latest Publications
- Open Access
- 30 June 2025
- Published by Nosov Magnitogorsk State Technical University in Electrotechnical Systems and Complexes
- No. 2(67)
Electromagnetic Compatibility Comparative Analysis of Powerful DC and AC Electric Drives with Supply Network
- 30 June 2025
- Published by Nosov Magnitogorsk State Technical University in Electrotechnical Systems and Complexes
- No. 2(67)
Open AccessElectromagnetic Compatibility Comparative Analysis of Powerful DC and AC Electric Drives with Supply Network
- Open Access
Current Electromagnetic Compatibility Problems of High-Power Industrial Electric Drives with Active Front-End Rectifiers Connected to a 6–35 kV Power Grid: A Comprehensive Overview
Today, electric drive systems based on frequency converters with active front-end rectifiers (FC-AFEs) are widespread across industries. In the course of the upgrade of production facilities, such systems replace the conventional converters with thyristor- and diode-based rectifiers. FC-AFEs have the following advantages: the capacity to regenerate the power to the grid and the capacity to operate at the set power factor. The manufacturers of FC-AFEs also claim that their products have the best electromagnetic compatibility (EMC) with the power grid. The best EMC shall be achieved via a multilevel FC-AFE topology and specialized pulse-width modulation (PWM) algorithms for AFE rectifiers. However, the experience of operating mid-voltage high-power electric drives with an FC-AFE in 6–35 kV factory distribution grids with non-linear frequency response due to resonant phenomena refutes the claims of the FC-AFE manufacturers. Resonant phenomena in 6–35 kV grids are caused by the interaction of the inductance of grid components (transformers, reactors) and the capacitance of output cable lines. If the resonance frequency at a sufficient amplitude corresponds to the harmonic frequency of the current consumed by the FC-AFE, the distribution grid will feature high-frequency voltage distortions. This may lead to failures in voltage quality-sensitive electrical consumers. This problem recurred at various metallurgical companies. The purpose of this research is to make a comprehensive overview of the EMC problems during the operation of FC-AFEs at active production facilities, as well as the analysis of the technical solutions aimed at the improvement of the EMC of high-power FC-AFEs with the power grid.
Open AccessCurrent Electromagnetic Compatibility Problems of High-Power Industrial Electric Drives with Active Front-End Rectifiers Connected to a 6–35 kV Power Grid: A Comprehensive Overview
Today, electric drive systems based on frequency converters with active front-end rectifiers (FC-AFEs) are widespread across industries. In the course of the upgrade of production facilities, such systems replace the conventional converters with thyristor- and diode-based rectifiers. FC-AFEs have the following advantages: the capacity to regenerate the power to the grid and the capacity to operate at the set power factor. The manufacturers of FC-AFEs also claim that their products have the best electromagnetic compatibility (EMC) with the power grid. The best EMC shall be achieved via a multilevel FC-AFE topology and specialized pulse-width modulation (PWM) algorithms for AFE rectifiers. However, the experience of operating mid-voltage high-power electric drives with an FC-AFE in 6–35 kV factory distribution grids with non-linear frequency response due to resonant phenomena refutes the claims of the FC-AFE manufacturers. Resonant phenomena in 6–35 kV grids are caused by the interaction of the inductance of grid components (transformers, reactors) and the capacitance of output cable lines. If the resonance frequency at a sufficient amplitude corresponds to the harmonic frequency of the current consumed by the FC-AFE, the distribution grid will feature high-frequency voltage distortions. This may lead to failures in voltage quality-sensitive electrical consumers. This problem recurred at various metallurgical companies. The purpose of this research is to make a comprehensive overview of the EMC problems during the operation of FC-AFEs at active production facilities, as well as the analysis of the technical solutions aimed at the improvement of the EMC of high-power FC-AFEs with the power grid.
- 23 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 373-377
Development of a Methodology to Assess the Impact Degree of High-Power Drives with Active Rectifiers on the Electricity Quality in In-plant Power Supply Systems
Active rectifiers are widely used on industrial sites today. These units are part of high power regulated alternating current drives. Their use is due to a number of advantages over classic diode rectifiers, such as the ability to recover braking energy into the supply network and, according to the manufacturers, better electromagnetic compatibility. However, experience in operating these devices shows that due to the use of pulse-width modulation in active rectifiers, there is a high severe distortion probability of supply mains voltage by high order harmonics, with numbers higher than 40-50. The essence of this phenomenon is the occurrence of a voltage drop in the high impedance parts of the network frequency response when even a small high-frequency current is flowing. The presence of high impedance sections in the frequency response is due to the parallel resonance between the inductance of the network transformer and the equivalent capacitance of the cables from the substation. Modern power quality standards applied in different countries do not take into account harmonics above 40-50 which makes it very difficult to assess the impact of high-power drives with active rectifiers on power quality in the supply network by conventional, certified power quality analysers. Therefore, it is an urgent task to develop a specialised methodology to assess the impact degree of a particular active rectifier on the network.
- 23 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 373-377
Development of a Methodology to Assess the Impact Degree of High-Power Drives with Active Rectifiers on the Electricity Quality in In-plant Power Supply Systems
Active rectifiers are widely used on industrial sites today. These units are part of high power regulated alternating current drives. Their use is due to a number of advantages over classic diode rectifiers, such as the ability to recover braking energy into the supply network and, according to the manufacturers, better electromagnetic compatibility. However, experience in operating these devices shows that due to the use of pulse-width modulation in active rectifiers, there is a high severe distortion probability of supply mains voltage by high order harmonics, with numbers higher than 40-50. The essence of this phenomenon is the occurrence of a voltage drop in the high impedance parts of the network frequency response when even a small high-frequency current is flowing. The presence of high impedance sections in the frequency response is due to the parallel resonance between the inductance of the network transformer and the equivalent capacitance of the cables from the substation. Modern power quality standards applied in different countries do not take into account harmonics above 40-50 which makes it very difficult to assess the impact of high-power drives with active rectifiers on power quality in the supply network by conventional, certified power quality analysers. Therefore, it is an urgent task to develop a specialised methodology to assess the impact degree of a particular active rectifier on the network.
- 23 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 359-366
Experimental Studies of Power Quality in the 34.5 kV Network of MMK Metalurji During Operation of Electric Drives with Active Rectifiers
Medium voltage distribution networks of 6 - 35 kV are used in in-plant power supply systems in steel mills. As a mutual influence result of the capacitances of long cable lines and the inductances of step-down transformers, resonance phenomena can occur in the medium frequency range. If the high-frequency harmonics generated by frequency converters with active rectifiers fall into the resonant range, this can lead to disturbances in the plant’s internal distribution network. Such phenomena can cause long downtime of technological equipment and product defects. This entails significant economic losses, especially in the production of high value-added products. This paper reflects the experimental research results of voltage quality in 34.5 kV distribution networks of metallurgical plant “MMK Metalurji”. Measures for electromagnetic compatibility improvement of frequency converters with active rectifiers of electric drives in hot strip mill 1750 with supply mains are proposed.
- 23 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 359-366
Experimental Studies of Power Quality in the 34.5 kV Network of MMK Metalurji During Operation of Electric Drives with Active Rectifiers
Medium voltage distribution networks of 6 - 35 kV are used in in-plant power supply systems in steel mills. As a mutual influence result of the capacitances of long cable lines and the inductances of step-down transformers, resonance phenomena can occur in the medium frequency range. If the high-frequency harmonics generated by frequency converters with active rectifiers fall into the resonant range, this can lead to disturbances in the plant’s internal distribution network. Such phenomena can cause long downtime of technological equipment and product defects. This entails significant economic losses, especially in the production of high value-added products. This paper reflects the experimental research results of voltage quality in 34.5 kV distribution networks of metallurgical plant “MMK Metalurji”. Measures for electromagnetic compatibility improvement of frequency converters with active rectifiers of electric drives in hot strip mill 1750 with supply mains are proposed.
- 4 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 689-693
Development of the Algorithm for Determining PWM Parameters of Active Rectifiers Based on Experimental Data
To date, frequency converters with active rectifiers are widely used in regulated medium voltage drives. In order to solve the electromagnetic compatibility problem of these drives with the network feeder, special PWM algorithms of active rectifiers are applied. These algorithms improve the harmonic composition of currents and voltages at the input of the active rectifier by removing or mitigating some of the most significant harmonics by selecting optimal gate switching angles. Some factors such as the presence of non-linear sections in the frequency response of supply network with high impedance value, arising from resonance phenomena can be not taken into account while calculating the optimum angles. In this case, even small amplitude harmonics of the active rectifier current can significantly distort the voltage shape at the point of common connection of the electrical consumers. In order to analyse how to ensure electromagnetic compatibility of frequency converters with active rectifiers in networks with resonance phenomena, it is necessary to know the parameters of the PWM algorithms used in a particular converter by means of mathematical modelling. Since converter manufacturers usually conceal the parameters of the PWM algorithms used in their products, a way to determine these parameters based on experimental data is needed. This paper discusses an algorithm for determining the PWM parameters of active rectifiers based on current waveforms obtained on the primary side of the matching transformer.
- 4 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 689-693
Development of the Algorithm for Determining PWM Parameters of Active Rectifiers Based on Experimental Data
To date, frequency converters with active rectifiers are widely used in regulated medium voltage drives. In order to solve the electromagnetic compatibility problem of these drives with the network feeder, special PWM algorithms of active rectifiers are applied. These algorithms improve the harmonic composition of currents and voltages at the input of the active rectifier by removing or mitigating some of the most significant harmonics by selecting optimal gate switching angles. Some factors such as the presence of non-linear sections in the frequency response of supply network with high impedance value, arising from resonance phenomena can be not taken into account while calculating the optimum angles. In this case, even small amplitude harmonics of the active rectifier current can significantly distort the voltage shape at the point of common connection of the electrical consumers. In order to analyse how to ensure electromagnetic compatibility of frequency converters with active rectifiers in networks with resonance phenomena, it is necessary to know the parameters of the PWM algorithms used in a particular converter by means of mathematical modelling. Since converter manufacturers usually conceal the parameters of the PWM algorithms used in their products, a way to determine these parameters based on experimental data is needed. This paper discusses an algorithm for determining the PWM parameters of active rectifiers based on current waveforms obtained on the primary side of the matching transformer.
- 4 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 896-901
Development of a Comprehensive Simulation Model of the Power Supply and Drive System Based on AFE-FC for Power Quality Research
The paper describes an improved simulation model of electrical complex containing in-plant power supply system of an industrial enterprise and main electric drives of a rolling mill based on frequency converters with active rectifiers. The simulation model is designed to study the voltage quality of various parts of the power supply system, taking into account possible complex resonance phenomena in the frequency response of the supply network. The simulation model has been developed in the Matlab-Simulink software package. The simulation model adequacy has been tested by comparing the simulation results with the data obtained by analysing the existing electrical complex operation at the metallurgical enterprise. The developed simulation model can be used when designing electrical complexes and power supply systems of powerful electric drives with frequency converters, as well as to improve their electromagnetic compatibility in the operating systems.
- 4 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 896-901
Development of a Comprehensive Simulation Model of the Power Supply and Drive System Based on AFE-FC for Power Quality Research
The paper describes an improved simulation model of electrical complex containing in-plant power supply system of an industrial enterprise and main electric drives of a rolling mill based on frequency converters with active rectifiers. The simulation model is designed to study the voltage quality of various parts of the power supply system, taking into account possible complex resonance phenomena in the frequency response of the supply network. The simulation model has been developed in the Matlab-Simulink software package. The simulation model adequacy has been tested by comparing the simulation results with the data obtained by analysing the existing electrical complex operation at the metallurgical enterprise. The developed simulation model can be used when designing electrical complexes and power supply systems of powerful electric drives with frequency converters, as well as to improve their electromagnetic compatibility in the operating systems.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 492-497
The Dynamic Operation Investigation of an Active Rectifier Control System with IGCT-Thyristor Switching Angle Table Selection Function
The paper investigates the dynamic operation modes of frequency converter active rectifiers with the previously proposed improved control system. This control system allows the use of IGCT thyristors switching angle tables with different switching frequencies depending on the operating mode of the frequency converter. The tables were changed when the equal control signals to the power switches of the active rectifier were generated using the current and the new tables. The research has been performed on the previously developed simulation model in the Matlab-Simulink software package. The analysis of the research results has shown the minimum disturbing effects on the regulated parameters of the active rectifier when changing the tables.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 492-497
The Dynamic Operation Investigation of an Active Rectifier Control System with IGCT-Thyristor Switching Angle Table Selection Function
The paper investigates the dynamic operation modes of frequency converter active rectifiers with the previously proposed improved control system. This control system allows the use of IGCT thyristors switching angle tables with different switching frequencies depending on the operating mode of the frequency converter. The tables were changed when the equal control signals to the power switches of the active rectifier were generated using the current and the new tables. The research has been performed on the previously developed simulation model in the Matlab-Simulink software package. The analysis of the research results has shown the minimum disturbing effects on the regulated parameters of the active rectifier when changing the tables.
- Open Access
- 24 December 2021
- Published by Nosov Magnitogorsk State Technical University in Electrotechnical Systems and Complexes
- Vol. 4 (53) , 62-68
Improved Control System Analysis of Frequency Converters Active Rectifiers as a Part of Rolling Mill Electric Drives
The paper proposes the control system for a frequency converter active rectifier with a variable switching frequency of the AR power switches, taking into account the changes in the operating modes of the rolling mill stand electric drive. In the AR control system, Selective Harmonic Elimination PWM is used. When the load is reduced or the electric drive is idle, the AR control system selects the table of switching angles of the power switches corresponding to the current operating mode. The use of tables with an increased switching frequency makes it possible to exclude a greater number of harmonics from the consumed current spectrum, which has a positive effect on the supply voltage power quality. A method is proposed for switching tables based on comparing the value of the AR current with predetermined limit values obtained using the developed technique for analyzing the thyristor thermal balance. Simulation modeling was carried out in the Matlab-Simulink software package on a complex mathematical model of the internal distribution network of a metallurgical enterprise, which has EDs with FC-AR. A feature of this supply network is the presence of complex resonance phenomena. Comparative analysis of the data obtained during simulation modeling for the cycle of operation of the rolling mill with electric drives based on FC-AR showed a positive technical effect on the power quality of the 10 kV supply network when the mill electric drive is idle or operates at reduced load.
- 24 December 2021
- Published by Nosov Magnitogorsk State Technical University in Electrotechnical Systems and Complexes
- Vol. 4 (53) , 62-68
Open AccessImproved Control System Analysis of Frequency Converters Active Rectifiers as a Part of Rolling Mill Electric Drives
The paper proposes the control system for a frequency converter active rectifier with a variable switching frequency of the AR power switches, taking into account the changes in the operating modes of the rolling mill stand electric drive. In the AR control system, Selective Harmonic Elimination PWM is used. When the load is reduced or the electric drive is idle, the AR control system selects the table of switching angles of the power switches corresponding to the current operating mode. The use of tables with an increased switching frequency makes it possible to exclude a greater number of harmonics from the consumed current spectrum, which has a positive effect on the supply voltage power quality. A method is proposed for switching tables based on comparing the value of the AR current with predetermined limit values obtained using the developed technique for analyzing the thyristor thermal balance. Simulation modeling was carried out in the Matlab-Simulink software package on a complex mathematical model of the internal distribution network of a metallurgical enterprise, which has EDs with FC-AR. A feature of this supply network is the presence of complex resonance phenomena. Comparative analysis of the data obtained during simulation modeling for the cycle of operation of the rolling mill with electric drives based on FC-AR showed a positive technical effect on the power quality of the 10 kV supply network when the mill electric drive is idle or operates at reduced load.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 535-540
Influence Investigation of Electric Drive Operation Mode at a Rolling Mill FC with AR on the 10kV Supply Network Voltage Quality
This paper considers the influence of frequency converters with active rectifiers in the main electric drives of four-stand mill on the voltage quality of 10 kV distribution network of in-plant power supply system at a metallurgical plant. The investigation was carried out using the initial and improved algorithms of pulse-width modulation of active rectifiers at various operation modes for electric drives of the rolling mill. The advanced algorithm essence was the use of switching angles tables providing the removal of harmonics, falling into the zone of resonances in the frequency response of the network. The current load diagrams of active rectifiers were used in the research to take into account operation modes of rolling mills’ electric drives. The studies were performed on a complex simulation model of the main mill drives and of the internal 10kV distribution network, which was implemented in the mathematical package Matlab-Simulink. The analysis of the research results showed the effectiveness of the improved PWM algorithms in terms of reducing the total harmonic distortion factor on the sections of the main step-down substation in all the static and dynamic operating modes of the rolling mill.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 535-540
Influence Investigation of Electric Drive Operation Mode at a Rolling Mill FC with AR on the 10kV Supply Network Voltage Quality
This paper considers the influence of frequency converters with active rectifiers in the main electric drives of four-stand mill on the voltage quality of 10 kV distribution network of in-plant power supply system at a metallurgical plant. The investigation was carried out using the initial and improved algorithms of pulse-width modulation of active rectifiers at various operation modes for electric drives of the rolling mill. The advanced algorithm essence was the use of switching angles tables providing the removal of harmonics, falling into the zone of resonances in the frequency response of the network. The current load diagrams of active rectifiers were used in the research to take into account operation modes of rolling mills’ electric drives. The studies were performed on a complex simulation model of the main mill drives and of the internal 10kV distribution network, which was implemented in the mathematical package Matlab-Simulink. The analysis of the research results showed the effectiveness of the improved PWM algorithms in terms of reducing the total harmonic distortion factor on the sections of the main step-down substation in all the static and dynamic operating modes of the rolling mill.