Charuksha Walgama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charuksha Walgama has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
Sadagopan Krishnan
Department of Chemistry Oklahoma State University Stillwater OK 74078 USA
15 shared publicationsRajasekhara Nerimetla
Department of Chemistry
12 shared publications- Sadagopan Krishnan
Oklahoma State University
10 shared publications Ian Richards
Interactives Executive Excellence LLC, Austin, Texas 78733 United States
3 shared publications- Richard M. Crooks
Department of Chemistry, The University of Texas at Austin, 100 E. 24th Street, Stop A1590, Austin, Texas 78712-1224, United States
3 shared publications Anuruddha Pathiranage
Department of Chemistry, Oklahoma State University, Stillwater, Oklahoma 74078, United States
2 shared publications
Latest Publications
- Open Access
- 25 November 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (12) , 768
Size Effects of Silver Nanoparticles and Magnetic Beads on Silver-Gold Galvanic Exchange in Aptamer-Based Electrochemical Assays
In this work, we investigated the influence of silver nanoparticle (AgNP) size (diameters of 20, 50, and 100 nm) and magnetic bead (MB) size (diameters from 100 to 4500 nm) on silver-gold galvanic exchange signal generation in magnetic electrochemical assays. Two conjugation strategies, including biotin-streptavidin interaction and a streptavidin-specific aptamer interaction, were compared to assess differences in binding chemistry and conjugation efficiency. Calibration studies showed that 50 nm diameter AgNPs provided the best sensitivity and galvanic exchange efficiency, yielding the lowest detection limits across both conjugation strategies. Larger AgNPs produced stronger signals but reached saturation rapidly, whereas smaller particles required higher concentrations to achieve equivalent silver content. Among MBs, 1000 nm beads consistently gave the highest galvanic exchange efficiency, offering sufficient surface area for AgNP loading while minimizing steric hindrance and electrode obstruction. These findings were confirmed by complementary electrochemical impedance spectroscopy, UV-Vis absorbance, and SEM imaging, which collectively demonstrated the strong influence of bead size on charge transfer resistance and conjugation efficiency. Overall, the combination of 50 nm AgNPs with 1000 nm MBs emerged as the optimal configuration, providing improved sensitivity and reproducibility. We believe these results offer valuable design guidelines for the development of next-generation aptamer-based electrochemical biosensors for biomarker detection.
- 25 November 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (12) , 768
Open AccessSize Effects of Silver Nanoparticles and Magnetic Beads on Silver-Gold Galvanic Exchange in Aptamer-Based Electrochemical Assays
In this work, we investigated the influence of silver nanoparticle (AgNP) size (diameters of 20, 50, and 100 nm) and magnetic bead (MB) size (diameters from 100 to 4500 nm) on silver-gold galvanic exchange signal generation in magnetic electrochemical assays. Two conjugation strategies, including biotin-streptavidin interaction and a streptavidin-specific aptamer interaction, were compared to assess differences in binding chemistry and conjugation efficiency. Calibration studies showed that 50 nm diameter AgNPs provided the best sensitivity and galvanic exchange efficiency, yielding the lowest detection limits across both conjugation strategies. Larger AgNPs produced stronger signals but reached saturation rapidly, whereas smaller particles required higher concentrations to achieve equivalent silver content. Among MBs, 1000 nm beads consistently gave the highest galvanic exchange efficiency, offering sufficient surface area for AgNP loading while minimizing steric hindrance and electrode obstruction. These findings were confirmed by complementary electrochemical impedance spectroscopy, UV-Vis absorbance, and SEM imaging, which collectively demonstrated the strong influence of bead size on charge transfer resistance and conjugation efficiency. Overall, the combination of 50 nm AgNPs with 1000 nm MBs emerged as the optimal configuration, providing improved sensitivity and reproducibility. We believe these results offer valuable design guidelines for the development of next-generation aptamer-based electrochemical biosensors for biomarker detection.
- Open Access
- 18 November 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (3) , 629-639
Linking Nanoscale Film Properties to Electrochemical Response in Cytochrome P450 Membrane Enzyme Films
Membrane-bound human liver cytochrome P450 (CYP) enzymes catalyze key steps in xenobiotic metabolism, yet their integration into analytical devices depends critically on surface chemistry and film mechanics. Bacterial membrane preparations (“bactosomes”) provide abundant CYP sources for in vitro measurements and biosensors. Here, cystamine self-assembled monolayers (SAMs) on gold-coated quartz were compared with polyethylenimine (PEI)-coated gold for immobilizing CYP bactosomes. Quartz crystal microbalance with dissipation monitoring (QCM-D) tracked adsorption and film evolution, enabling quantitative estimates of the mass loading, thickness, and viscoelastic properties. After washing, bactosomes/SAM reached ∼113 nm thickness and 11.9 μg cm–2 mass, whereas bactosomes/PEI yielded ∼40 nm and 4.2 μg cm–2. Viscosity values were similar (2.5 cP), but elastic moduli differed: 2.0 × 104 Pa for bactosomes/SAM vs 2.5 × 105 Pa for bactosomes/PEI, indicating rigid films on PEI. Electrochemical characterization under argon and O2-saturated conditions showed higher faradaic responses for SAM-modified electrodes (Ip = 5.6 ± 0.6 μA in Ar; Ilimiting = 95.9 ± 3.9 μA in O2) than PEI-coated electrodes (Ip = 3.2 ± 1.0 μA in Ar and Ilimiting = 72.6 ± 3.3 μA in O2). These differences are attributed to the greater immobilized mass of bactosomes on the SAM-modified surface and the proportional electronic connectivity of their redox enzymes with the underlying gold electrode despite their higher film thickness. This work provides quantitative benchmarks for tuning film mechanics and coverage to optimize CYP-bactosome biocatalytic electrodes, informing the design of robust, high-signal platforms for biosensing and high-throughput drug metabolism assays. Correlation of QCM-D metrics with voltammetric outputs establishes a direct link among film mechanics, coverage, and electron-transfer efficiency, offering a generalizable framework for membrane enzyme immobilization. These measurements provide practical guidance for selecting surface chemistries when prioritizing either robustness or signal amplitude in CYP-based sensing architectures.
- 18 November 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (3) , 629-639
Open AccessLinking Nanoscale Film Properties to Electrochemical Response in Cytochrome P450 Membrane Enzyme Films
Membrane-bound human liver cytochrome P450 (CYP) enzymes catalyze key steps in xenobiotic metabolism, yet their integration into analytical devices depends critically on surface chemistry and film mechanics. Bacterial membrane preparations (“bactosomes”) provide abundant CYP sources for in vitro measurements and biosensors. Here, cystamine self-assembled monolayers (SAMs) on gold-coated quartz were compared with polyethylenimine (PEI)-coated gold for immobilizing CYP bactosomes. Quartz crystal microbalance with dissipation monitoring (QCM-D) tracked adsorption and film evolution, enabling quantitative estimates of the mass loading, thickness, and viscoelastic properties. After washing, bactosomes/SAM reached ∼113 nm thickness and 11.9 μg cm–2 mass, whereas bactosomes/PEI yielded ∼40 nm and 4.2 μg cm–2. Viscosity values were similar (2.5 cP), but elastic moduli differed: 2.0 × 104 Pa for bactosomes/SAM vs 2.5 × 105 Pa for bactosomes/PEI, indicating rigid films on PEI. Electrochemical characterization under argon and O2-saturated conditions showed higher faradaic responses for SAM-modified electrodes (Ip = 5.6 ± 0.6 μA in Ar; Ilimiting = 95.9 ± 3.9 μA in O2) than PEI-coated electrodes (Ip = 3.2 ± 1.0 μA in Ar and Ilimiting = 72.6 ± 3.3 μA in O2). These differences are attributed to the greater immobilized mass of bactosomes on the SAM-modified surface and the proportional electronic connectivity of their redox enzymes with the underlying gold electrode despite their higher film thickness. This work provides quantitative benchmarks for tuning film mechanics and coverage to optimize CYP-bactosome biocatalytic electrodes, informing the design of robust, high-signal platforms for biosensing and high-throughput drug metabolism assays. Correlation of QCM-D metrics with voltammetric outputs establishes a direct link among film mechanics, coverage, and electron-transfer efficiency, offering a generalizable framework for membrane enzyme immobilization. These measurements provide practical guidance for selecting surface chemistries when prioritizing either robustness or signal amplitude in CYP-based sensing architectures.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (48) , 2476
The Optimization of Au-Ag Galvanic Exchange Reaction for Aptamer-Based Electrochemical Assays
Aptamers, short oligonucleotides that can fold into specific three-dimensional structures, are gaining prominence as versatile recognition elements in biochemical assays, offering significant advantages over traditional monoclonal antibodies. These advantages include ease of synthesis, functionalization, stability, and reproducibility. This study focuses on optimizing an electrochemical assay using aptamers for biosensing applications, particularly leveraging the galvanic exchange (GE) reaction between silver and gold as the core mechanism for signal generation. This assay employs a streptavidin-specific aptamer as the model recognition element. The aptamer is functionalized with a thiol group at one end to enable covalent conjugation to spherical silver nanoparticles (AgNPs). The opposite end of the aptamer binds specifically to streptavidin-coated magnetic microbeads (MB), forming a conjugate that can be used for electrochemical analysis. The GE reaction is central to this assay, where AgNPs undergo oxidation by electrogenerated gold ions transferring silver ions into solution. The silver ions can be electrodeposited and quantified using anodic stripping voltammetry (ASV). The MB-aptamer-AgNPs conjugates are concentrated onto the surface of a screen-printed electrode (SPE) via a magnetic field. In this study, we investigate the effects of nanoparticle size (20 nm, 50 nm, and 100 nm) on the electrochemical signal, as the size of the silver nanoparticles can influence the extent of oxidation and the resulting signal strength. Additionally, the impact of magnetic bead size on the conjugation efficiency and electrochemical performance is explored. These optimization efforts aim to improve the sensitivity and reliability of aptamer-based assays using GE for biomarker detection. Preliminary results indicate that oxidation signals involving aptamer-streptavidin interactions are comparable to previous studies involving a biotin-streptavidin interaction, suggesting that aptamers may offer a viable alternative to traditional biomolecular recognition elements in electrochemical assays. We believe this research highlights the growing potential of aptamers as alternatives to antibodies, offering simplified synthesis and more consistent performance, and demonstrates how GE can be applicable to enhance the analytical capabilities of electrochemical biosensors.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (48) , 2476
The Optimization of Au-Ag Galvanic Exchange Reaction for Aptamer-Based Electrochemical Assays
Aptamers, short oligonucleotides that can fold into specific three-dimensional structures, are gaining prominence as versatile recognition elements in biochemical assays, offering significant advantages over traditional monoclonal antibodies. These advantages include ease of synthesis, functionalization, stability, and reproducibility. This study focuses on optimizing an electrochemical assay using aptamers for biosensing applications, particularly leveraging the galvanic exchange (GE) reaction between silver and gold as the core mechanism for signal generation. This assay employs a streptavidin-specific aptamer as the model recognition element. The aptamer is functionalized with a thiol group at one end to enable covalent conjugation to spherical silver nanoparticles (AgNPs). The opposite end of the aptamer binds specifically to streptavidin-coated magnetic microbeads (MB), forming a conjugate that can be used for electrochemical analysis. The GE reaction is central to this assay, where AgNPs undergo oxidation by electrogenerated gold ions transferring silver ions into solution. The silver ions can be electrodeposited and quantified using anodic stripping voltammetry (ASV). The MB-aptamer-AgNPs conjugates are concentrated onto the surface of a screen-printed electrode (SPE) via a magnetic field. In this study, we investigate the effects of nanoparticle size (20 nm, 50 nm, and 100 nm) on the electrochemical signal, as the size of the silver nanoparticles can influence the extent of oxidation and the resulting signal strength. Additionally, the impact of magnetic bead size on the conjugation efficiency and electrochemical performance is explored. These optimization efforts aim to improve the sensitivity and reliability of aptamer-based assays using GE for biomarker detection. Preliminary results indicate that oxidation signals involving aptamer-streptavidin interactions are comparable to previous studies involving a biotin-streptavidin interaction, suggesting that aptamers may offer a viable alternative to traditional biomolecular recognition elements in electrochemical assays. We believe this research highlights the growing potential of aptamers as alternatives to antibodies, offering simplified synthesis and more consistent performance, and demonstrates how GE can be applicable to enhance the analytical capabilities of electrochemical biosensors.
- Open Access
- 7 April 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 5 (3) , 325-331
Size-Dependent Electrochemical and Morphological Properties of Magnetite Nanoparticles Adsorbed on Electrodes
We investigated the influence of particle size on the electrochemical behavior of Fe3O4 magnetite nanoparticles (MNPs) electrostatically adsorbed onto graphite electrodes modified with a preadsorbed poly(ethylenimine) polycation layer. Three hydrodynamic sizes (50, 100, and 200 nm) were selected to assess size-dependent differences in electrochemical response using cyclic voltammetry under well-controlled adsorption and measurement conditions. The 50 nm MNPs exhibited the highest electroactive response and peroxidase-like electrocatalytic currents, which are consistent with greater surface area-to-volume ratios. Qualitative image analysis from atomic force microscopy and scanning electron microscopy revealed closer particle spacing and more extended surface contact for the smaller MNPs, in contrast to isolated aggregates formed by larger particles. These surface-level differences were reflected in the electrochemical signals, where the 50 nm particles yielded higher electroactive surface coverage. The study demonstrates how particle size and interfacial organization influence electrochemical readouts, underscoring the utility of correlating microscopy with electrochemical data to evaluate nanoparticle-based sensing interfaces.
- 7 April 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 5 (3) , 325-331
Open AccessSize-Dependent Electrochemical and Morphological Properties of Magnetite Nanoparticles Adsorbed on Electrodes
We investigated the influence of particle size on the electrochemical behavior of Fe3O4 magnetite nanoparticles (MNPs) electrostatically adsorbed onto graphite electrodes modified with a preadsorbed poly(ethylenimine) polycation layer. Three hydrodynamic sizes (50, 100, and 200 nm) were selected to assess size-dependent differences in electrochemical response using cyclic voltammetry under well-controlled adsorption and measurement conditions. The 50 nm MNPs exhibited the highest electroactive response and peroxidase-like electrocatalytic currents, which are consistent with greater surface area-to-volume ratios. Qualitative image analysis from atomic force microscopy and scanning electron microscopy revealed closer particle spacing and more extended surface contact for the smaller MNPs, in contrast to isolated aggregates formed by larger particles. These surface-level differences were reflected in the electrochemical signals, where the 50 nm particles yielded higher electroactive surface coverage. The study demonstrates how particle size and interfacial organization influence electrochemical readouts, underscoring the utility of correlating microscopy with electrochemical data to evaluate nanoparticle-based sensing interfaces.
- 9 August 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-01 (41) , 2355
Magnetic Metalloimmunoassays: Influence of Particle Shape and Size on Galvanic Exchange-Based Electrochemical Detection
The electrooxidation of silver (Ag) offers improved signal sharpness and intensity, enabling precise measurements and enhanced resolution in electrochemical sensing. Leveraging silver nanoparticles (AgNPs) as indirect labels in electrochemical assays provides a distinct advantage for detecting various biomarkers at clinically relevant concentrations. In our recent work, we have introduced an electrochemical approach that involves a galvanic exchange (GE) reaction between electrodeposited gold and AgNPs, followed by anodic stripping voltammetry (ASV), with potential applications in immunosensing. In this assay protocol, specific monoclonal antibodies immobilize the biomarker of interest separately on AgNPs and magnetic beads. Subsequently, magnetic bead-AgNP conjugates are attracted to the electrode surface by a magnetic force. However, to achieve the expected analytical performance of the bioassay, it is imperative to characterize the composition, size, shape, and surface modifications of the AgNPs. Consequently, our research focuses on investigating the electrochemical properties of a model bioconjugate formed between magnetic microbeads (MB) and AgNPs through Streptavidin-biotin interactions under various assay conditions. Notably, our recent studies reveal that conducting the GE cycle for three repetitions significantly enhances the Ag signal, yielding an improvement of approximately two-fold or greater compared to previously reported methods. Previous studies have shown that altering the shape of AgNPs, transitioning from nanospheres to other forms like nanocubes and nanodisks enhances both the limit of detection and the range of analyte detection. However, despite these enhancements, spherical AgNPs remain the most stable and easily synthesized option, characterized by excellent homogeneity. Recently, we compared AgNPs with diameters ranging from 20 to 100 nm paired with magnetic microbeads with diameters spanning from 50 nm to 3 µm to identify the optimal combination. Preliminary results indicate that the Mb (3 µm)-AgNP (50 nm) conjugate exhibits the highest Ag charge and Ag collection efficiency. Nonetheless, critical knowledge gaps persist regarding the fundamental understanding of the electrogenerated GE process and we are continually working on refining the electrochemical and assay parameters to develop a robust universal platform for GE-based electrochemical immunosensing.
- 9 August 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-01 (41) , 2355
Magnetic Metalloimmunoassays: Influence of Particle Shape and Size on Galvanic Exchange-Based Electrochemical Detection
The electrooxidation of silver (Ag) offers improved signal sharpness and intensity, enabling precise measurements and enhanced resolution in electrochemical sensing. Leveraging silver nanoparticles (AgNPs) as indirect labels in electrochemical assays provides a distinct advantage for detecting various biomarkers at clinically relevant concentrations. In our recent work, we have introduced an electrochemical approach that involves a galvanic exchange (GE) reaction between electrodeposited gold and AgNPs, followed by anodic stripping voltammetry (ASV), with potential applications in immunosensing. In this assay protocol, specific monoclonal antibodies immobilize the biomarker of interest separately on AgNPs and magnetic beads. Subsequently, magnetic bead-AgNP conjugates are attracted to the electrode surface by a magnetic force. However, to achieve the expected analytical performance of the bioassay, it is imperative to characterize the composition, size, shape, and surface modifications of the AgNPs. Consequently, our research focuses on investigating the electrochemical properties of a model bioconjugate formed between magnetic microbeads (MB) and AgNPs through Streptavidin-biotin interactions under various assay conditions. Notably, our recent studies reveal that conducting the GE cycle for three repetitions significantly enhances the Ag signal, yielding an improvement of approximately two-fold or greater compared to previously reported methods. Previous studies have shown that altering the shape of AgNPs, transitioning from nanospheres to other forms like nanocubes and nanodisks enhances both the limit of detection and the range of analyte detection. However, despite these enhancements, spherical AgNPs remain the most stable and easily synthesized option, characterized by excellent homogeneity. Recently, we compared AgNPs with diameters ranging from 20 to 100 nm paired with magnetic microbeads with diameters spanning from 50 nm to 3 µm to identify the optimal combination. Preliminary results indicate that the Mb (3 µm)-AgNP (50 nm) conjugate exhibits the highest Ag charge and Ag collection efficiency. Nonetheless, critical knowledge gaps persist regarding the fundamental understanding of the electrogenerated GE process and we are continually working on refining the electrochemical and assay parameters to develop a robust universal platform for GE-based electrochemical immunosensing.
- Open Access
- 3 August 2024
- Published by MDPI AG in Metabolites
- Vol. 14 (8) , 429
Electrochemical Probing of Human Liver Subcellular S9 Fractions for Drug Metabolite Synthesis
Human liver subcellular fractions, including liver microsomes (HLM), liver cytosol fractions, and S9 fractions, are extensively utilized in in vitro assays to predict liver metabolism. The S9 fractions are supernatants of human liver homogenates that contain both microsomes and cytosol, which include most cytochrome P450 (CYP) enzymes and soluble phase II enzymes such as glucuronosyltransferases and sulfotransferases. This study reports on the direct electrochemistry and biocatalytic features of redox-active enzymes in S9 fractions for the first time. We investigated the electrochemical properties of S9 films by immobilizing them onto a high-purity graphite (HPG) electrode and performing cyclic voltammetry under anaerobic (Ar-saturated) and aerobic (O2-saturated) conditions. The heterogeneous electron transfer rate between the S9 film and the HPG electrode was found to be 14 ± 3 s−1, with a formal potential of −0.451 V vs. Ag/AgCl reference electrode, which confirmed the electrochemical activation of the FAD/FMN cofactor containing CYP450-reductase (CPR) as the electron receiver from the electrode. The S9 films have also demonstrated catalytic oxygen reduction under aerobic conditions, identical to HLM films attached to similar electrodes. Additionally, we investigated CYP activity in the S9 biofilm for phase I metabolism using diclofenac hydroxylation as a probe reaction and identified metabolic products using liquid chromatography–mass spectrometry (LC-MS). Investigating the feasibility of utilizing liver S9 fractions in such electrochemical assays offers significant advantages for pharmacological and toxicological evaluations of new drugs in development while providing valuable insights for the development of efficient biosensor and bioreactor platforms.
- 3 August 2024
- Published by MDPI AG in Metabolites
- Vol. 14 (8) , 429
Open AccessElectrochemical Probing of Human Liver Subcellular S9 Fractions for Drug Metabolite Synthesis
Human liver subcellular fractions, including liver microsomes (HLM), liver cytosol fractions, and S9 fractions, are extensively utilized in in vitro assays to predict liver metabolism. The S9 fractions are supernatants of human liver homogenates that contain both microsomes and cytosol, which include most cytochrome P450 (CYP) enzymes and soluble phase II enzymes such as glucuronosyltransferases and sulfotransferases. This study reports on the direct electrochemistry and biocatalytic features of redox-active enzymes in S9 fractions for the first time. We investigated the electrochemical properties of S9 films by immobilizing them onto a high-purity graphite (HPG) electrode and performing cyclic voltammetry under anaerobic (Ar-saturated) and aerobic (O2-saturated) conditions. The heterogeneous electron transfer rate between the S9 film and the HPG electrode was found to be 14 ± 3 s−1, with a formal potential of −0.451 V vs. Ag/AgCl reference electrode, which confirmed the electrochemical activation of the FAD/FMN cofactor containing CYP450-reductase (CPR) as the electron receiver from the electrode. The S9 films have also demonstrated catalytic oxygen reduction under aerobic conditions, identical to HLM films attached to similar electrodes. Additionally, we investigated CYP activity in the S9 biofilm for phase I metabolism using diclofenac hydroxylation as a probe reaction and identified metabolic products using liquid chromatography–mass spectrometry (LC-MS). Investigating the feasibility of utilizing liver S9 fractions in such electrochemical assays offers significant advantages for pharmacological and toxicological evaluations of new drugs in development while providing valuable insights for the development of efficient biosensor and bioreactor platforms.
- Top Cited PapersOpen Access
Electrochemical and Colorimetric Nanosensors for Detection of Heavy Metal Ions: A Review
Human exposure to acute and chronic levels of heavy metal ions are linked with various health issues, including reduced children’s intelligence quotients, developmental challenges, cancers, hypertension, immune system compromises, cytotoxicity, oxidative cellular damage, and neurological disorders, among other health challenges. The potential environmental HMI contaminations, the biomagnification of heavy metal ions along food chains, and the associated risk factors of heavy metal ions on public health safety are a global concern of top priority. Hence, developing low-cost analytical protocols capable of rapid, selective, sensitive, and accurate detection of heavy metal ions in environmental samples and consumable products is of global public health interest. Conventional flame atomic absorption spectroscopy, graphite furnace atomic absorption spectroscopy, atomic emission spectroscopy, inductively coupled plasma–optical emission spectroscopy, inductively coupled plasma–mass spectroscopy, X-ray diffractometry, and X-ray fluorescence have been well-developed for HMIs and trace element analysis with excellent but varying degrees of sensitivity, selectivity, and accuracy. In addition to high instrumental running and maintenance costs and specialized personnel training, these instruments are not portable, limiting their practicality for on-demand, in situ, field study, or point-of-need HMI detection. Increases in the use of electrochemical and colorimetric techniques for heavy metal ion detections arise because of portable instrumentation, high sensitivity and selectivity, cost-effectiveness, small size requirements, rapidity, and visual detection of colorimetric nanosensors that facilitate on-demand, in situ, and field heavy metal ion detections. This review highlights the new approach to low-cost, rapid, selective, sensitive, and accurate detection of heavy metal ions in ecosystems (soil, water, air) and consumable products. Specifically, the review highlights low-cost, portable, and recent advances in smartphone-operated screen-printed electrodes (SPEs), plastic chip SPES, and carbon fiber paper-based nanosensors for environmental heavy metal ion detection. In addition, the review highlights recent advances in colorimetric nanosensors for heavy metal ion detection requirements. The review provides the advantages of electrochemical and optical nanosensors over the conventional methods of HMI analyses. The review further provides in-depth coverage of the detection of arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), and zinc (Zn) ions in the ecosystem, with emphasis on environmental and biological samples. In addition, the review discusses the advantages and challenges of the current electrochemical and colorimetric nanosensors protocol for heavy metal ion detection. It provides insight into the future directions in the use of the electrochemical and colorimetric nanosensors protocol for heavy metal ion detection.
Top Cited PapersOpen AccessElectrochemical and Colorimetric Nanosensors for Detection of Heavy Metal Ions: A Review
Human exposure to acute and chronic levels of heavy metal ions are linked with various health issues, including reduced children’s intelligence quotients, developmental challenges, cancers, hypertension, immune system compromises, cytotoxicity, oxidative cellular damage, and neurological disorders, among other health challenges. The potential environmental HMI contaminations, the biomagnification of heavy metal ions along food chains, and the associated risk factors of heavy metal ions on public health safety are a global concern of top priority. Hence, developing low-cost analytical protocols capable of rapid, selective, sensitive, and accurate detection of heavy metal ions in environmental samples and consumable products is of global public health interest. Conventional flame atomic absorption spectroscopy, graphite furnace atomic absorption spectroscopy, atomic emission spectroscopy, inductively coupled plasma–optical emission spectroscopy, inductively coupled plasma–mass spectroscopy, X-ray diffractometry, and X-ray fluorescence have been well-developed for HMIs and trace element analysis with excellent but varying degrees of sensitivity, selectivity, and accuracy. In addition to high instrumental running and maintenance costs and specialized personnel training, these instruments are not portable, limiting their practicality for on-demand, in situ, field study, or point-of-need HMI detection. Increases in the use of electrochemical and colorimetric techniques for heavy metal ion detections arise because of portable instrumentation, high sensitivity and selectivity, cost-effectiveness, small size requirements, rapidity, and visual detection of colorimetric nanosensors that facilitate on-demand, in situ, and field heavy metal ion detections. This review highlights the new approach to low-cost, rapid, selective, sensitive, and accurate detection of heavy metal ions in ecosystems (soil, water, air) and consumable products. Specifically, the review highlights low-cost, portable, and recent advances in smartphone-operated screen-printed electrodes (SPEs), plastic chip SPES, and carbon fiber paper-based nanosensors for environmental heavy metal ion detection. In addition, the review highlights recent advances in colorimetric nanosensors for heavy metal ion detection requirements. The review provides the advantages of electrochemical and optical nanosensors over the conventional methods of HMI analyses. The review further provides in-depth coverage of the detection of arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), and zinc (Zn) ions in the ecosystem, with emphasis on environmental and biological samples. In addition, the review discusses the advantages and challenges of the current electrochemical and colorimetric nanosensors protocol for heavy metal ion detection. It provides insight into the future directions in the use of the electrochemical and colorimetric nanosensors protocol for heavy metal ion detection.
- 28 August 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-01 (41) , 2344
Electrochemical Activation of Metabolic Enzymes in Human Liver S9 Fractions
Human liver subcellular fractions such as liver microsomes, liver cytosol fractions, or S9 fractions are widely used in in-vitro assays to predict liver metabolism. The S9 fractions are the supernatants of human liver homogenates consist of both human liver microsomes and the cytosol. Therefore, these fractions contain majority of cytochrome P450 (CYP) enzymes and soluble phase II enzymes like glucuronosyltransferases, N-acetyl transferases, sulfotransferases, and glutathione-S-transferases. Here we report the direct electrochemistry and biocatalytic features of redox active enzymes impregnated in S9 fractions. We investigated the electrochemical properties of S9 films by immobilizing them onto a high purity graphite electrode and performing cyclic voltammetry in anaerobic (Ar saturated) and aerobic (O2 saturated) conditions. The electron transfer between the S9 film and the high purity graphite electrode was observed at the formal potential of -0.48 V, with respect to Ag/AgCl reference electrode, which confirmed the activation of CYP450 reductase enzyme in the film. These films also demonstrated a catalytic oxygen reduction with a maximum current density of ~0.5 mA cm-2 at the scan rate of 0.050V/s. We investigated the CYP activity in the S9 biofilm for phase 1 metabolism using diclofenac hydroxylation as a probe reaction and could able to identify metabolic products using liquid chromatography-mass spectrometry (LC-MS) technique. Eventually, we envision to develop a platform to perform both phase I and II metabolic reactions in a single electrochemical assay.
- 28 August 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-01 (41) , 2344
Electrochemical Activation of Metabolic Enzymes in Human Liver S9 Fractions
Human liver subcellular fractions such as liver microsomes, liver cytosol fractions, or S9 fractions are widely used in in-vitro assays to predict liver metabolism. The S9 fractions are the supernatants of human liver homogenates consist of both human liver microsomes and the cytosol. Therefore, these fractions contain majority of cytochrome P450 (CYP) enzymes and soluble phase II enzymes like glucuronosyltransferases, N-acetyl transferases, sulfotransferases, and glutathione-S-transferases. Here we report the direct electrochemistry and biocatalytic features of redox active enzymes impregnated in S9 fractions. We investigated the electrochemical properties of S9 films by immobilizing them onto a high purity graphite electrode and performing cyclic voltammetry in anaerobic (Ar saturated) and aerobic (O2 saturated) conditions. The electron transfer between the S9 film and the high purity graphite electrode was observed at the formal potential of -0.48 V, with respect to Ag/AgCl reference electrode, which confirmed the activation of CYP450 reductase enzyme in the film. These films also demonstrated a catalytic oxygen reduction with a maximum current density of ~0.5 mA cm-2 at the scan rate of 0.050V/s. We investigated the CYP activity in the S9 biofilm for phase 1 metabolism using diclofenac hydroxylation as a probe reaction and could able to identify metabolic products using liquid chromatography-mass spectrometry (LC-MS) technique. Eventually, we envision to develop a platform to perform both phase I and II metabolic reactions in a single electrochemical assay.
- 4 August 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (75) , 11161-11173
Silver nanoparticles in electrochemical immunosensing and the emergence of silver–gold galvanic exchange detection
Nanoparticle-based electrochemical immunosensors demonstrate high sensitivity toward biomarker detection due to the large surface area of the nanoparticles and their ability to amplify the signal of the target molecule. Additionally, they have a fast response time, relatively lower cost, and can be easily miniaturized for point-of-care applications. Among noble metals, silver nanoparticles (AgNPs) have been extensively used in electrochemical sensors due to their unique properties, such as catalytic activity and excellent electrical conductivity. This Feature Article describes six approaches for incorporating AgNPs in electrochemical platforms, featuring the most recent developments in the silver–gold galvanic exchange-based detection strategy. With a few exceptions, many of these detection methods use AgNP oxidation into Ag+ ions, followed by electrodeposition of Ag+ ions onto the working electrode as zero-valent Ag metal and a final stripping step using a voltammetric technique. Combining these steps provides desirable low detection limits and good sensitivity for various biomarkers. A few other methods involved the reduction of Ag+ ions and depositing them as Ag metal onto the electrode using a reagent mixture so that the striping analysis could be performed. Typically, this reagent mixture includes Ag+ ions, a reducing agent, or an enzyme substrate. Besides, AgNPs have also been directly used to modify the surface of electrodes to facilitate kinetically favored redox-mediated electrochemical reactions. In addition to Ag detection methods, this report will also provide recent examples to illustrate how the size and shape of AgNPs impact the detection limits and sensitivity of an electrochemical assay. Finally, we discuss recent developments in lab-on-a-chip type immunosensors designed explicitly for Ag-based metalloimmunoassay detection, and we envision that this article will provide a comprehensive summary of the operational principles and new insights into such immunoassay systems.
- 4 August 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (75) , 11161-11173
Silver nanoparticles in electrochemical immunosensing and the emergence of silver–gold galvanic exchange detection
Nanoparticle-based electrochemical immunosensors demonstrate high sensitivity toward biomarker detection due to the large surface area of the nanoparticles and their ability to amplify the signal of the target molecule. Additionally, they have a fast response time, relatively lower cost, and can be easily miniaturized for point-of-care applications. Among noble metals, silver nanoparticles (AgNPs) have been extensively used in electrochemical sensors due to their unique properties, such as catalytic activity and excellent electrical conductivity. This Feature Article describes six approaches for incorporating AgNPs in electrochemical platforms, featuring the most recent developments in the silver–gold galvanic exchange-based detection strategy. With a few exceptions, many of these detection methods use AgNP oxidation into Ag+ ions, followed by electrodeposition of Ag+ ions onto the working electrode as zero-valent Ag metal and a final stripping step using a voltammetric technique. Combining these steps provides desirable low detection limits and good sensitivity for various biomarkers. A few other methods involved the reduction of Ag+ ions and depositing them as Ag metal onto the electrode using a reagent mixture so that the striping analysis could be performed. Typically, this reagent mixture includes Ag+ ions, a reducing agent, or an enzyme substrate. Besides, AgNPs have also been directly used to modify the surface of electrodes to facilitate kinetically favored redox-mediated electrochemical reactions. In addition to Ag detection methods, this report will also provide recent examples to illustrate how the size and shape of AgNPs impact the detection limits and sensitivity of an electrochemical assay. Finally, we discuss recent developments in lab-on-a-chip type immunosensors designed explicitly for Ag-based metalloimmunoassay detection, and we envision that this article will provide a comprehensive summary of the operational principles and new insights into such immunoassay systems.
- 9 October 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-02 (52) , 1991
Silver Nanoparticle Labels for Electrochemical Detection of Bioassays
Electrochemistry plays a major role in immunosensor development because of its higher sensitivity, simplicity, portability, and rapidity compared to more common enzymatic, fluorescent and radioactive labelling methods. Silver nanoparticles (AgNPs) have been identified as potential electrochemical labels for such immunoassays. Characterizing the composition, size, shape, and surface modifications of the AgNP is important to achieve expected analytical performance of the bio assay. Here we are interested in studying the effect of nanoparticle shape towards the electrochemical detection of a metallo-immunoassay using Au-Ag galvanic exchange (GE) reaction followed by anodic stripping voltammetry. We observe that during GE between electrogenerated Au3+ and the Ag labels, a thin shell of Au forms on the surface of the NP and prevent further exchange. This shell is more porous when GE proceeds on silver nanocubes (AgNCs) compared to spherical silver nanoparticles (sAgNPs), and therefore, more exchange occurs when using AgNCs. More interestingly, optimizing the ratio of the two types of AgNP labels, we could able to decrease the LOD of a biological assay designed to detect a heart failure biomarker (NT-proBNP) without compromising the dynamic range compared to using either of the two labels independently. This made it possible to achieve the clinically relevant range for NT-proBNP analysis used by physicians for heart failure risk stratification.
- 9 October 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-02 (52) , 1991
Silver Nanoparticle Labels for Electrochemical Detection of Bioassays
Electrochemistry plays a major role in immunosensor development because of its higher sensitivity, simplicity, portability, and rapidity compared to more common enzymatic, fluorescent and radioactive labelling methods. Silver nanoparticles (AgNPs) have been identified as potential electrochemical labels for such immunoassays. Characterizing the composition, size, shape, and surface modifications of the AgNP is important to achieve expected analytical performance of the bio assay. Here we are interested in studying the effect of nanoparticle shape towards the electrochemical detection of a metallo-immunoassay using Au-Ag galvanic exchange (GE) reaction followed by anodic stripping voltammetry. We observe that during GE between electrogenerated Au3+ and the Ag labels, a thin shell of Au forms on the surface of the NP and prevent further exchange. This shell is more porous when GE proceeds on silver nanocubes (AgNCs) compared to spherical silver nanoparticles (sAgNPs), and therefore, more exchange occurs when using AgNCs. More interestingly, optimizing the ratio of the two types of AgNP labels, we could able to decrease the LOD of a biological assay designed to detect a heart failure biomarker (NT-proBNP) without compromising the dynamic range compared to using either of the two labels independently. This made it possible to achieve the clinically relevant range for NT-proBNP analysis used by physicians for heart failure risk stratification.