ACApostolos N. Chamos

Apostolos N. Chamos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Apostolos N. Chamos has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fatigue behavior of precipitation strengthened Cu–Ni–Si alloy modified by Cr and Zr addition

    by Ş. Hakan Atapek, Spiros Pantelakis, Şeyda Polat, Apostolos Chamos, Gülşah Aktaş Çelik

    Purpose: The purpose of this paper is to investigate the fatigue behavior of precipitation-strengthened Cu‒2.55Ni‒0.55Si alloy, modified by the addition of 0.25 Cr and 0.25 Zr (wt%), using mechanical and fractographical studies to reveal the effect of microstructural features on the fracture.Design/methodology/approach: For strengthening, cast and hot forged alloy was subjected to solution annealing at 900°C for 60 min, followed by quenching in water and then aging at 490°C for 180 min. Precipitation-hardened alloy was exposed to fatigue tests atR=−1 and different stress levels. All fracture surfaces were examined within the frame of fractographical analysis.Findings: Fine Ni-rich silicides responsible for the precipitation strengthening were observed within the matrix and their interactions with the dislocations at lower stress level resulted in localized shearing and fine striations. Although, by the addition of Cr and Zr, the matrix consisted of hard Ni, Zr-rich and Cr-rich silicides, these precipitates adversely affected the fatigue behavior acting as nucleation sites for cracks.Originality/value: These findings contribute to the present knowledge by revealing the effect of microstructural features on the mechanical behavior of precipitation-hardened Cu‒Ni‒Si alloy modified by Cr and Zr addition.


  • Open Access

    Characterization of fatigue failed aged Cu-Ni-Si alloys

    by Ş. Hakan Atapek, Spiros G. Pantelakis, Apostolos N. Chamos, Gülşah Aktaş Çelik

    The precipitation hardenable and non-toxic Cu-Ni-Si alloys are good alternatives to Cu-Be and Cu-Co-Ni-Be alloys due to their high strength and high conductivity that can be attained by not only alloying but also thermo-mechanical routes. In this study, the fractographic analysis was carried out to understand the fatigue failure of aged 2.55Ni-0.55Si-0.25Zr-0.25Cr (wt-%) alloy which is a member of Corson family. In fatigue tests, a constant amplitude loading was applied at a stress ratio (R = σmin/σmax) of -1 and different stress levels (400, 350, 200 and 175 MPa) were used. The fracture response of the alloy was discussed depending on the applied stress levels and microstructural features. It was concluded that (i) Ni,Zr-rich precipitates and Cr-rich precipitates at the grain boundaries caused crack nucleation at all stress levels and (ii) the interaction between Ni-rich silicides and dislocations at lower stress level resulted in localized shearing and fine striations.


  • Open Access

    Effect of corrosion and sandblasting on the high cycle fatigue behavior of reinforcing B500C steel bars

    by Marina C. Vasco, Panagiota Polydoropoulou, Apostolos N. Chamos, Spiros G. Pantelakis

    In a series of applications, steel reinforced concrete structures are subjected to fatigue loads during their service life, what in most cases happens in corrosive environments. Surface treatments have been proved to represent proper processes in order to improve both fatigue and corrosion resistances. In this work, the effect of corrosion and sandblasting on the high cycle fatigue behavior reinforcing steel bars is investigated. The investigated material is the reinforcing steel bar of technical class B500C, of nominal diameter of 12 mm. Steel bars specimens were first exposed to corrosion in alternate salt spray environment for 30 and 60 days and subjected to both tensile and fatigue tests. Then, a series of specimens were subjected to common sandblasting, corroded and mechanically tested. Metallographic investigation and corrosion damage evaluation regarding mass loss and martensitic area reduction were performed. Tensile tests were conducted after each corrosion exposure period prior to the fatigue tests. Fatigue tests were performed at a stress ratio, R, of 0.1 and loading frequency of 20 Hz. All fatigue tests series as well as tensile test were also performed for as received steel bars to obtain the reference behavior. The results have shown that sandblasting hardly affects the tensile behavior of the uncorroded material. The effect of sandblasting on the tensile behavior of pre-corroded specimens seems to be also limited. On the other hand, fatigue results indicate an improved fatigue behavior for the sandblasted material after 60 days of corrosion exposure. Martensitic area reductions, mass loss and depth of the pits were significantly smaller for the case of sandblasted materials, which confirms an increased corrosion resistance.


  • Effect of environment's aggressiveness on the corrosion damage evolution and mechanical behavior of AA 2024‐T3

    by M. C. Vasco, A. N. Chamos, Sp. G. Pantelakis

    The aim of this work is to contribute on establishing correlations between corrosion damage from accelerated laboratory corrosion tests of varying aggressiveness; by accounting for both, the metallographic features of corrosion damage and the mechanical properties of the corroded material. The work is based on the investigation of corrosion damage caused by the exposure of 2024‐T3 aluminum alloy to 3.5% NaCl solution, which is presently considered to properly represent in‐service exposure. Corrosion damage evolution was quantified for periods ranging between 500 and 3000 hours by evaluating pitting density, depth, and diameter. It was compared to available results of corrosion damage of the same alloy subjected to exfoliation corrosion test. Furthermore, the tensile properties of precorroded material in each solution were evaluated. The results allow the formulation of correlation functions between corrosion damage geometrical metallographic features from low‐ to high‐aggressiveness environment exposures. On the other hand, the degradation of tensile properties, and particularly of tensile ductility, is more pronounced in specimens exposed to higher corrosion rate environments, even when damage in both environments leads to equivalent metallographic features. This suggests significant differences in the underlying physical mechanisms of the damage accumulation process when the same material is exposed to different corrosive solutions. This work suggests the need to expand current corrosion damage interpretation, to account not only for geometrical metallographic features but also for mechanical properties of the affected material.


  • Corrosion damage evolution of the aircraft aluminum alloy 2024 T3

    by Spiros Pantelakis, Dorothea Setsika, Apostolos Chamos, Anna Zervaki

    Purpose: – The purpose of this paper is to quantify the corrosion damage evolution that has occurred on the aircraft aluminum alloy 2024 after the exposure to Exfoliation Corrosion Test (EXCO) solution. Moreover, the effect of the evolving corrosion damage on the materials mechanical properties has been assessed. The relevance of the corrosion damage induced by the exposure to the laboratory EXCO for linking it to the damage developed after the exposure of the material on several outdoor corrosive environments or in service is discussed. Design/methodology/approach: – To induce corrosion damage the EXCO has been used. For the quantification of corrosion damage the metallographic features considered have been pit depth, diameter, pitting density and pit shape. The effect of the evolving corrosion damage on the materials mechanical properties has been assessed by means of tensile tests on pre corroded specimens. Findings: – The results have shown that corrosion damage starts from pitting and evolves to exfoliation, after the development of intergranular corrosion. This evolution is expressed by the increase of the depth of attack, as well as through the significant growth of the diameter of the damaged areas. The results of the tensile tests performed on pre corroded material made an appreciable decrease of the materials tensile properties evident. The decrease of the tensile ductility may become dramatic and increases on severity with increasing corrosion exposure time. SEM fractography revealed a quasi-cleavage zone beneath the depth of corrosion attack. Originality/value: – The results underline the impact of corrosion damage on the mechanical behavior of the aluminum alloy 2024 T3 and demonstrate the need for further investigation of the corrosion effect on the structural integrity of the material. This work provides an experimental database concerning the quantification of corrosion damage evolution and the loss of material properties due to corrosion.


  • Open Access

    Fatigue Performance of Pre-corroded 6xxx Aluminum Alloy Laser Beam Welds with Dissimilar Heat Treatment

    by T. Kermanidis, A.D. Zervaki, V.M Odas, A.N. Chamos, Sp.G. Pantelakis