Jack E. Manuel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jack E. Manuel has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Alexander D. Dymnikov
Louisiana Accelerator Center, University of Louisiana at Lafayette, 104 E University Ave., Lafayette, Louisiana 70503, USA
1 shared publication- Bibhudutta Rout
Department of Physics University of North Texas Denton Texas USA
1 shared publication Dustin Z. Phillips
Louisiana Accelerator Center, University of Louisiana at Lafayette, 104 E University Ave., Lafayette, Louisiana 70503, USA
1 shared publication- Gary A. Glass
Ion Beam Laboratory Department of Physics University of North Texas 210 Ave A Denton TX 76203 USA
1 shared publication Szabolcs Z. Szilasi
Institute of Nuclear Research of the Hungarian Academy of Sciences, H-4026 Debrecen Bem tér 18/c, P.O. Box 51, H-4001 Debrecen, Hungary
1 shared publication- Tilo Reinert
Paul Flechsig Institute, Center of Neuropathology and Brain Research, Leipzig University, Leipzig, Germany
1 shared publication
Latest Publications
- 1 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (8) , 086103
Note: Performance of a novel electrostatic quadrupole doublet for nuclear microprobe application
The newly designed and constructed electrostatic quadrupole doublet (EQD) at the University of North Texas (UNT) has achieved mass independent focusing of MeV particles to a spot size of 3.3 × 3.5 μm. The EQD is compared to the Louisiana magnetic doublet which is also in use at UNT. Characteristics such as demagnification and sensitivity to aberrations are simulated by the matrix raytracing software, propagation of rays and aberrations by matrices and compared for each focusing system. Particle induced x-ray emission (PIXE) maps of a 2000 mesh Cu grid are compared and show that both doublets produce suitable spot sizes for microprobe analysis. A coarser, 200 mesh grid and incident beams of 2 MeV H+ and O+ show the EQD to be stigmatic given common aperture sizes and lens potentials.
- 1 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (8) , 086103
Note: Performance of a novel electrostatic quadrupole doublet for nuclear microprobe application
The newly designed and constructed electrostatic quadrupole doublet (EQD) at the University of North Texas (UNT) has achieved mass independent focusing of MeV particles to a spot size of 3.3 × 3.5 μm. The EQD is compared to the Louisiana magnetic doublet which is also in use at UNT. Characteristics such as demagnification and sensitivity to aberrations are simulated by the matrix raytracing software, propagation of rays and aberrations by matrices and compared for each focusing system. Particle induced x-ray emission (PIXE) maps of a 2000 mesh Cu grid are compared and show that both doublets produce suitable spot sizes for microprobe analysis. A coarser, 200 mesh grid and incident beams of 2 MeV H+ and O+ show the EQD to be stigmatic given common aperture sizes and lens potentials.