Eisuke Sato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eisuke Sato has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Kenta Takada
Graduate School of Comprehensive Human Sciences, University of Tsukuba
3 shared publications Tomonori Isobe
Graduate School of Comprehensive Human Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan
3 shared publicationsAkira Matsumura
Department of Neurosurgery, Faculty of Medicine, University of Tsukuba
2 shared publicationsTetsuya Yamamoto
Department of Neurosurgery, Faculty of Medicine, University of Tsukuba
2 shared publicationsFumiyo Yoshida
Faculty of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, Japan
1 shared publicationHideyuki Kato
Department of Radiology, Chiba University Hospital
1 shared publication
Latest Publications
- 21 April 2021
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 52 (5) , 619-631
Evaluation of a Polyethylene Glycol Phantom for Measuring Apparent Diffusion Coefficients Using Three 3.0 T MRI Systems
- 21 April 2021
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 52 (5) , 619-631
Evaluation of a Polyethylene Glycol Phantom for Measuring Apparent Diffusion Coefficients Using Three 3.0 T MRI Systems
- 1 October 2018
- Published by Elsevier in Journal of Affective Disorders
- Vol. 238, 472-481
Attentional bias modification alters intrinsic functional network of attentional control: A randomized controlled trial
- 1 October 2018
- Published by Elsevier in Journal of Affective Disorders
- Vol. 238, 472-481
Attentional bias modification alters intrinsic functional network of attentional control: A randomized controlled trial
- 28 July 2016
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 39 (3) , 687-696
Development of simple high-precision two-dimensional dose-distribution measurement method for proton beam therapy using imaging plate and EBT3
Although there are several two-dimensional (2D) dose-distribution measurement methods using proton beam therapy, they all have drawbacks; hence, there is no standard method established worldwide. The purpose of this study was to develop a simple, high-precision 2D distribution measurement method for proton beam therapy that uses an imaging plate and EBT3. First, we expanded the maximum readable dose (saturation dose) in the imaging plate. The method involves (i) the control of the fading phenomenon by an annealing process and (ii) the control of the photostimulated luminescence (PSL) phenomenon using a longpass filter (LPF). In method (i), upon heating at 80 °C, the PSL became 0.485 times the room temperature, and in method (ii), we attenuated the PSL by a factor of 0.245 using an LPF. Thus, by combining methods (i) and (ii), we expanded the saturation dose to 2 Gy. Thus, it was possible to measure the imaging plate and EBT3 in the same dose range. We simultaneously measured the percent depth dose using imaging plate and EBT3. We defined a correction factor to match the measured values—which had a reduced sensitivity because of the linear energy transfer (LET) dependence of the imaging plate and EBT3—with reference data and developed a correction factor function. Subsequently, by defining the relative LET dependence of imaging plate and EBT3 as the relative sensitivity and converting the relationship imaging plate between the relative sensitivity and correction factor into a function, we obtained a sensitivity-correction function. By employing this function, measurements with the same accuracy as the reference data were performed using the imaging plate and EBT3.
- 28 July 2016
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 39 (3) , 687-696
Development of simple high-precision two-dimensional dose-distribution measurement method for proton beam therapy using imaging plate and EBT3
Although there are several two-dimensional (2D) dose-distribution measurement methods using proton beam therapy, they all have drawbacks; hence, there is no standard method established worldwide. The purpose of this study was to develop a simple, high-precision 2D distribution measurement method for proton beam therapy that uses an imaging plate and EBT3. First, we expanded the maximum readable dose (saturation dose) in the imaging plate. The method involves (i) the control of the fading phenomenon by an annealing process and (ii) the control of the photostimulated luminescence (PSL) phenomenon using a longpass filter (LPF). In method (i), upon heating at 80 °C, the PSL became 0.485 times the room temperature, and in method (ii), we attenuated the PSL by a factor of 0.245 using an LPF. Thus, by combining methods (i) and (ii), we expanded the saturation dose to 2 Gy. Thus, it was possible to measure the imaging plate and EBT3 in the same dose range. We simultaneously measured the percent depth dose using imaging plate and EBT3. We defined a correction factor to match the measured values—which had a reduced sensitivity because of the linear energy transfer (LET) dependence of the imaging plate and EBT3—with reference data and developed a correction factor function. Subsequently, by defining the relative LET dependence of imaging plate and EBT3 as the relative sensitivity and converting the relationship imaging plate between the relative sensitivity and correction factor into a function, we obtained a sensitivity-correction function. By employing this function, measurements with the same accuracy as the reference data were performed using the imaging plate and EBT3.
- 1 June 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (5) , 644-648
Influence of echo time in quantitative proton MR spectroscopy using LCModel
- 1 June 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (5) , 644-648
Influence of echo time in quantitative proton MR spectroscopy using LCModel
- 1 June 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 88, 99-103
Intracellular boron accumulation in CHO-K1 cells using amino acid transport control
- 1 June 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 88, 99-103
Intracellular boron accumulation in CHO-K1 cells using amino acid transport control
- 1 January 2014
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 4, 816-819
Measurement of dose distribution during combined IVR procedure using the film method
- 1 January 2014
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 4, 816-819
Measurement of dose distribution during combined IVR procedure using the film method
- 1 May 2007
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 14 (5) , 470-473
Characterizing the auditory changes in tumor metastasis to the bilateral internal auditory canals
- 1 May 2007
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 14 (5) , 470-473
Characterizing the auditory changes in tumor metastasis to the bilateral internal auditory canals