Jian Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jian Xu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Changhuei Yang
Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125, USA
9 shared publications- Ali Kazemi Jahromi
Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125, USA
5 shared publications - Changhuei Yang
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
4 shared publications Michelle Cua
CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
3 shared publications- Ruizhi Cao
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
3 shared publications - Yan Liu
Indiana University, School of Optometry, Bloomington, Indiana, United States
3 shared publications
Latest Publications
- Top Cited Papers
- 30 May 2022
- Published by Springer Nature in Nature Photonics
- Vol. 16 (6) , 462-468
High-resolution non-line-of-sight imaging employing active focusing
- 30 May 2022
- Published by Springer Nature in Nature Photonics
- Vol. 16 (6) , 462-468
Top Cited PapersHigh-resolution non-line-of-sight imaging employing active focusing
- Open Access
- 1 September 2021
- Published by AIP Publishing in APL Photonics
- Vol. 6 (9) , 099901
Erratum: “Diffusing wave spectroscopy: A unified treatment on temporal sampling and speckle ensemble methods” [APL Photonics 6, 016105 (2021)]
- 1 September 2021
- Published by AIP Publishing in APL Photonics
- Vol. 6 (9) , 099901
Open AccessErratum: “Diffusing wave spectroscopy: A unified treatment on temporal sampling and speckle ensemble methods” [APL Photonics 6, 016105 (2021)]
- Open Access
- 23 April 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-10
Optical information transmission through complex scattering media with optical-channel-based intensity streaming
For the past decade, optical wavefront shaping has been the standard technique to control light through scattering media. Implicit in this dominance is the assumption that manipulating optical interference is a necessity for optical control through scattering media. In this paper, we challenge this assumption by reporting on an alternate approach for light control through a disordered scattering medium – optical-channel-based intensity streaming (OCIS). Instead of actively tuning the interference between the optical paths via wavefront shaping, OCIS controls light and transmits information through scattering media through linear intensity operations. We demonstrate a set of OCIS experiments that connect to some wavefront shaping implementations, i.e. iterative wavefront optimization, digital optical phase conjugation, image transmission through transmission matrix, and direct imaging through scattering media. We experimentally created focus patterns through scattering media on a sub-millisecond timescale. We also demonstrate that OCIS enables a scattering medium mediated secure optical communication application.
- 23 April 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-10
Open AccessOptical information transmission through complex scattering media with optical-channel-based intensity streaming
For the past decade, optical wavefront shaping has been the standard technique to control light through scattering media. Implicit in this dominance is the assumption that manipulating optical interference is a necessity for optical control through scattering media. In this paper, we challenge this assumption by reporting on an alternate approach for light control through a disordered scattering medium – optical-channel-based intensity streaming (OCIS). Instead of actively tuning the interference between the optical paths via wavefront shaping, OCIS controls light and transmits information through scattering media through linear intensity operations. We demonstrate a set of OCIS experiments that connect to some wavefront shaping implementations, i.e. iterative wavefront optimization, digital optical phase conjugation, image transmission through transmission matrix, and direct imaging through scattering media. We experimentally created focus patterns through scattering media on a sub-millisecond timescale. We also demonstrate that OCIS enables a scattering medium mediated secure optical communication application.
- Open Access
- 1 January 2021
- Published by AIP Publishing in APL Photonics
- Vol. 6 (1) , 016105
Diffusing wave spectroscopy: A unified treatment on temporal sampling and speckle ensemble methods
Diffusing wave spectroscopy (DWS) is a well-known set of methods to measure the temporal dynamics of dynamic samples. In DWS, dynamic samples scatter the incident coherent light, and the information of the temporal dynamics is encoded in the scattered light. To record and analyze the light signal, there exist two types of methods—temporal sampling methods and speckle ensemble methods. Temporal sampling methods, including diffuse correlation spectroscopy, use one or multiple large bandwidth detectors to sample well and analyze the temporal light signal to infer the sample temporal dynamics. Speckle ensemble methods, including speckle visibility spectroscopy, use a high-pixel-count camera sensor to capture a speckle pattern and use the speckle contrast to infer sample temporal dynamics. In this paper, we theoretically and experimentally demonstrate that the decorrelation time (τ) measurement accuracy or signal-to-noise ratio (SNR) of the two types of methods has a unified and similar fundamental expression based on the number of independent observables (NIO) and the photon flux. Given a time measurement duration, the NIO in temporal sampling methods is constrained by the measurement duration, while speckle ensemble methods can outperform by using simultaneous sampling channels to scale up the NIO significantly. In the case of optical brain monitoring, the interplay of these factors favors speckle ensemble methods. We illustrate that this important engineering consideration is consistent with the previous research on blood pulsatile flow measurements, where a speckle ensemble method operating at 100-fold lower photon flux than a conventional temporal sampling system can achieve a comparable SNR.
- 1 January 2021
- Published by AIP Publishing in APL Photonics
- Vol. 6 (1) , 016105
Open AccessDiffusing wave spectroscopy: A unified treatment on temporal sampling and speckle ensemble methods
Diffusing wave spectroscopy (DWS) is a well-known set of methods to measure the temporal dynamics of dynamic samples. In DWS, dynamic samples scatter the incident coherent light, and the information of the temporal dynamics is encoded in the scattered light. To record and analyze the light signal, there exist two types of methods—temporal sampling methods and speckle ensemble methods. Temporal sampling methods, including diffuse correlation spectroscopy, use one or multiple large bandwidth detectors to sample well and analyze the temporal light signal to infer the sample temporal dynamics. Speckle ensemble methods, including speckle visibility spectroscopy, use a high-pixel-count camera sensor to capture a speckle pattern and use the speckle contrast to infer sample temporal dynamics. In this paper, we theoretically and experimentally demonstrate that the decorrelation time (τ) measurement accuracy or signal-to-noise ratio (SNR) of the two types of methods has a unified and similar fundamental expression based on the number of independent observables (NIO) and the photon flux. Given a time measurement duration, the NIO in temporal sampling methods is constrained by the measurement duration, while speckle ensemble methods can outperform by using simultaneous sampling channels to scale up the NIO significantly. In the case of optical brain monitoring, the interplay of these factors favors speckle ensemble methods. We illustrate that this important engineering consideration is consistent with the previous research on blood pulsatile flow measurements, where a speckle ensemble method operating at 100-fold lower photon flux than a conventional temporal sampling system can achieve a comparable SNR.
- Open Access
- 1 December 2020
- Published by AIP Publishing in APL Photonics
- Vol. 5 (12) , 126102
Interferometric speckle visibility spectroscopy (ISVS) for human cerebral blood flow monitoring
Infrared light scattering methods have been developed and employed to non-invasively monitor human cerebral blood flow (CBF). However, the number of reflected photons that interact with the brain is low when detecting blood flow in deep tissue. To tackle this photon-starved problem, we present and demonstrate the idea of interferometric speckle visibility spectroscopy (ISVS). In ISVS, an interferometric detection scheme is used to boost the weak signal light. The blood flow dynamics are inferred from the speckle statistics of a single frame speckle pattern. We experimentally demonstrated the improvement in the measurement of fidelity by introducing interferometric detection when the signal photon number is low. We apply the ISVS system to monitor the human CBF in situations where the light intensity is ∼100-fold less than that in common diffuse correlation spectroscopy (DCS) implementations. Due to the large number of pixels (∼2 × 105) used to capture light in the ISVS system, we are able to collect a similar number of photons within one exposure time as in normal DCS implementations. Our system operates at a sampling rate of 100 Hz. At the exposure time of 2 ms, the average signal photoelectron number is ∼0.95 count/pixel, yielding a single pixel interferometric measurement signal-to-noise ratio (SNR) of ∼0.97. The total ∼2 × 105 pixels provide an expected overall SNR of 436. We successfully demonstrate that the ISVS system is able to monitor the human brain pulsatile blood flow, as well as the blood flow change when a human subject is doing a breath-holding task.
- 1 December 2020
- Published by AIP Publishing in APL Photonics
- Vol. 5 (12) , 126102
Open AccessInterferometric speckle visibility spectroscopy (ISVS) for human cerebral blood flow monitoring
Infrared light scattering methods have been developed and employed to non-invasively monitor human cerebral blood flow (CBF). However, the number of reflected photons that interact with the brain is low when detecting blood flow in deep tissue. To tackle this photon-starved problem, we present and demonstrate the idea of interferometric speckle visibility spectroscopy (ISVS). In ISVS, an interferometric detection scheme is used to boost the weak signal light. The blood flow dynamics are inferred from the speckle statistics of a single frame speckle pattern. We experimentally demonstrated the improvement in the measurement of fidelity by introducing interferometric detection when the signal photon number is low. We apply the ISVS system to monitor the human CBF in situations where the light intensity is ∼100-fold less than that in common diffuse correlation spectroscopy (DCS) implementations. Due to the large number of pixels (∼2 × 105) used to capture light in the ISVS system, we are able to collect a similar number of photons within one exposure time as in normal DCS implementations. Our system operates at a sampling rate of 100 Hz. At the exposure time of 2 ms, the average signal photoelectron number is ∼0.95 count/pixel, yielding a single pixel interferometric measurement signal-to-noise ratio (SNR) of ∼0.97. The total ∼2 × 105 pixels provide an expected overall SNR of 436. We successfully demonstrate that the ISVS system is able to monitor the human brain pulsatile blood flow, as well as the blood flow change when a human subject is doing a breath-holding task.
- Open Access
Diffusing wave spectroscopy: a unified treatment on temporal sampling and speckle ensemble methods
Diffusing wave spectroscopy (DWS) is a well-known set of methods to measure the temporal dynamics of dynamic samples. In DWS, dynamic samples scatter the incident coherent light, and the information of the temporal dynamics is encoded in the scattered light. To record and analyze the light signal, there exist two types of methods - temporal sampling methods and speckle ensemble methods. Temporal sampling methods, including diffuse correlation spectroscopy (DCS), use one or multiple large bandwidth detectors to well sample and analyze the temporal light signal to infer the sample temporal dynamics. Speckle ensemble methods, including speckle visibility spectroscopy (SVS), use a high-pixel-count camera sensor to capture a speckle pattern and use the speckle contrast to infer sample temporal dynamics. In this paper, we theoretically and experimentally demonstrate that the decorrelation time ({\tau}) measurement accuracy or SNR of the two types of methods has a unified and similar fundamental expression based on the number of independent observables (NIO) and the photon flux. Given a time measurement duration, NIO in temporal sampling methods is constrained by the measurement duration, while speckle ensemble methods can outperform by using simultaneous sampling channels to scale up NIO significantly. In the case of optical brain monitoring, the interplay of these factors favors speckle ensemble methods. We illustrate that this important engineering consideration is consistent with the previous research on blood pulsatile flow measurements, where a speckle ensemble method operating at 100-fold lower photon flux than a conventional temporal sampling system can achieve a comparable SNR.Open AccessDiffusing wave spectroscopy: a unified treatment on temporal sampling and speckle ensemble methods
Diffusing wave spectroscopy (DWS) is a well-known set of methods to measure the temporal dynamics of dynamic samples. In DWS, dynamic samples scatter the incident coherent light, and the information of the temporal dynamics is encoded in the scattered light. To record and analyze the light signal, there exist two types of methods - temporal sampling methods and speckle ensemble methods. Temporal sampling methods, including diffuse correlation spectroscopy (DCS), use one or multiple large bandwidth detectors to well sample and analyze the temporal light signal to infer the sample temporal dynamics. Speckle ensemble methods, including speckle visibility spectroscopy (SVS), use a high-pixel-count camera sensor to capture a speckle pattern and use the speckle contrast to infer sample temporal dynamics. In this paper, we theoretically and experimentally demonstrate that the decorrelation time ({\tau}) measurement accuracy or SNR of the two types of methods has a unified and similar fundamental expression based on the number of independent observables (NIO) and the photon flux. Given a time measurement duration, NIO in temporal sampling methods is constrained by the measurement duration, while speckle ensemble methods can outperform by using simultaneous sampling channels to scale up NIO significantly. In the case of optical brain monitoring, the interplay of these factors favors speckle ensemble methods. We illustrate that this important engineering consideration is consistent with the previous research on blood pulsatile flow measurements, where a speckle ensemble method operating at 100-fold lower photon flux than a conventional temporal sampling system can achieve a comparable SNR. - 20 May 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (11) , 2973-2976
Imaging through highly scattering human skulls with ultrasound-modulated optical tomography
Advances in human brain imaging technologies are critical to understanding how the brain works and the diagnosis of brain disorders. Existing technologies have different drawbacks, and the human skull poses a great challenge for pure optical and ultrasound imaging technologies. Here we demonstrate the feasibility of using ultrasound-modulated optical tomography, a hybrid technology that combines both light and sound, to image through human skulls. Single-shot off-axis holography was used to measure the field of the ultrasonically tagged light. This Letter paves the way for imaging the brain noninvasively through the skull, with optical contrast and a higher spatial resolution than that of diffuse optical tomography.
- 20 May 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (11) , 2973-2976
Imaging through highly scattering human skulls with ultrasound-modulated optical tomography
Advances in human brain imaging technologies are critical to understanding how the brain works and the diagnosis of brain disorders. Existing technologies have different drawbacks, and the human skull poses a great challenge for pure optical and ultrasound imaging technologies. Here we demonstrate the feasibility of using ultrasound-modulated optical tomography, a hybrid technology that combines both light and sound, to image through human skulls. Single-shot off-axis holography was used to measure the field of the ultrasonically tagged light. This Letter paves the way for imaging the brain noninvasively through the skull, with optical contrast and a higher spatial resolution than that of diffuse optical tomography.
- 11 May 2020
- Published by Springer Nature in Nature Photonics
- Vol. 14 (8) , 511-516
Fluorescence imaging through dynamic scattering media with speckle-encoded ultrasound-modulated light correlation
- 11 May 2020
- Published by Springer Nature in Nature Photonics
- Vol. 14 (8) , 511-516
Fluorescence imaging through dynamic scattering media with speckle-encoded ultrasound-modulated light correlation