Ruizhi Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruizhi Cao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Changhuei Yang
Department of Electrical Engineering California Institute of Technology Pasadena CA USA
5 shared publications- Changhuei Yang
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
5 shared publications - Haowen Zhou
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
4 shared publications - Jian Xu
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
3 shared publications - Baptiste Blochet
Institute for the Neurosciences UMR 8003 Saints-Pères Paris CNRS Université de Paris 45 rue des Saints-Pères 75006 Paris France
2 shared publications - Cheng Shen
California Institute of Technology
2 shared publications
Latest Publications
- Open Access
- 11 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Analytic Fourier ptychotomography for aberration-free and high-resolution volumetric refractive index imaging
Three-dimensional (3D) refractive index tomography offers label-free quantitative volumetric imaging. However, existing tomography approaches are limited by optical aberrations, limited resolution, and computational complexity. To overcome these issues, we propose Analytic Fourier Ptychotomography (AFP), a computational microscopy technique that analytically reconstructs aberration-free, complex-valued 3D refractive index distributions without iterative optimization or axial scanning. AFP employs a unique prior based on the finite sample thickness to recast the inverse scattering problem into analytically solvable linear equations. Unlike iterative methods, AFP does not require parameter tuning and computationally intensive optimizations, and can achieve efficient, robust, and generalizable image reconstructions across diverse samples and systems. We experimentally demonstrated that AFP greatly enhanced image quality and resolution under various aberration conditions across a range of applications. AFP corrected aberrations associated with 25 Zernike modes (with maximal phase difference of 2.3π and maximal Zernike coefficient value of 4), extended the synthetic numerical aperture from 0.41 to 0.99, and provided a two-fold resolution enhancement in all directions. With its simplicity, robustness, and broad applicability, AFP offers a user-friendly imaging platform for quantitative 3D analysis in biology, microbial ecology, and clinical science.
- 11 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessAnalytic Fourier ptychotomography for aberration-free and high-resolution volumetric refractive index imaging
Three-dimensional (3D) refractive index tomography offers label-free quantitative volumetric imaging. However, existing tomography approaches are limited by optical aberrations, limited resolution, and computational complexity. To overcome these issues, we propose Analytic Fourier Ptychotomography (AFP), a computational microscopy technique that analytically reconstructs aberration-free, complex-valued 3D refractive index distributions without iterative optimization or axial scanning. AFP employs a unique prior based on the finite sample thickness to recast the inverse scattering problem into analytically solvable linear equations. Unlike iterative methods, AFP does not require parameter tuning and computationally intensive optimizations, and can achieve efficient, robust, and generalizable image reconstructions across diverse samples and systems. We experimentally demonstrated that AFP greatly enhanced image quality and resolution under various aberration conditions across a range of applications. AFP corrected aberrations associated with 25 Zernike modes (with maximal phase difference of 2.3π and maximal Zernike coefficient value of 4), extended the synthetic numerical aperture from 0.41 to 0.99, and provided a two-fold resolution enhancement in all directions. With its simplicity, robustness, and broad applicability, AFP offers a user-friendly imaging platform for quantitative 3D analysis in biology, microbial ecology, and clinical science.
- Open Access
Analytic Fourier ptychotomography for volumetric refractive index imaging
Three-dimensional (3D) refractive index (RI) tomography offers label-free, quantitative volumetric imaging but faces limitations due to optical aberrations, limited resolution, and the computational complexity inherent to existing approaches. To overcome these barriers, we propose Analytic Fourier Ptychotomography (AFP), a new computational microscopy technique that analytically reconstructs aberration-free, complex-valued 3D RI distributions without iterative optimization or axial scanning. AFP incorporates a new concept called the finite sample thickness (FST) prior, and analytically solves the inverse scattering problem through three sequential steps: complex-field reconstruction via the Kramers-Kronig relation, linear aberration correction using overlapping spectra, and analytic spectrum extension into the darkfield region. Unlike iterative reconstruction methods, AFP does not require parameter tuning or computationally intensive optimizations, which are often error-prone and non-generalizable. We experimentally demonstrate that AFP significantly enhances image quality and resolution under various aberration conditions across a range of applications. AFP corrected aberrations associated with 25 Zernike modes (with a maximal phase difference of 2.3$π$ and maximal Zernike coefficient value of 4), extended the synthetic numerical aperture from 0.41 to 0.99, and provided a two-fold resolution enhancement in all directions. AFP's simplicity and robustness make it an attractive imaging technology for quantitative 3D analysis in biological, microbial ecological, and medical studies.
Open AccessAnalytic Fourier ptychotomography for volumetric refractive index imaging
Three-dimensional (3D) refractive index (RI) tomography offers label-free, quantitative volumetric imaging but faces limitations due to optical aberrations, limited resolution, and the computational complexity inherent to existing approaches. To overcome these barriers, we propose Analytic Fourier Ptychotomography (AFP), a new computational microscopy technique that analytically reconstructs aberration-free, complex-valued 3D RI distributions without iterative optimization or axial scanning. AFP incorporates a new concept called the finite sample thickness (FST) prior, and analytically solves the inverse scattering problem through three sequential steps: complex-field reconstruction via the Kramers-Kronig relation, linear aberration correction using overlapping spectra, and analytic spectrum extension into the darkfield region. Unlike iterative reconstruction methods, AFP does not require parameter tuning or computationally intensive optimizations, which are often error-prone and non-generalizable. We experimentally demonstrate that AFP significantly enhances image quality and resolution under various aberration conditions across a range of applications. AFP corrected aberrations associated with 25 Zernike modes (with a maximal phase difference of 2.3$π$ and maximal Zernike coefficient value of 4), extended the synthetic numerical aperture from 0.41 to 0.99, and provided a two-fold resolution enhancement in all directions. AFP's simplicity and robustness make it an attractive imaging technology for quantitative 3D analysis in biological, microbial ecological, and medical studies.
- 27 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1666-1677
Dome-APIC illumination design for high space-bandwidth product analytic imaging
Breaking the tradeoff between resolution and field-of-view, while obtaining distortion-free images, can be achieved through computational imaging techniques. A recent approach, Angular Ptychographic Imaging with Close-form method (APIC), has showcased its capability to analytically recover both intricate aberrations and high space-bandwidth product complex optical fields with NA-matching and darkfield illuminations. However, its flat illumination setup limits its ability to efficiently reconstruct a large field-of-view simultaneously with high resolution, owing to the curvature in the wavefront from NA-matching illuminations and the finite beam angle of the Lambertian LED light source. Here, we introduce an illumination framework tailored for APIC consisting of a distant annular LED ring and an LED dome that enables the reconstruction of a larger area with an extended synthetic numerical aperture, consequently enhancing resolution. For a single set of measurements, our new prototype, termed Dome-APIC can reach 620nm resolution with a 10×/0.25 NA objective lens over a field-of-view of 450 µm x 450 µm.
- 27 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1666-1677
Dome-APIC illumination design for high space-bandwidth product analytic imaging
Breaking the tradeoff between resolution and field-of-view, while obtaining distortion-free images, can be achieved through computational imaging techniques. A recent approach, Angular Ptychographic Imaging with Close-form method (APIC), has showcased its capability to analytically recover both intricate aberrations and high space-bandwidth product complex optical fields with NA-matching and darkfield illuminations. However, its flat illumination setup limits its ability to efficiently reconstruct a large field-of-view simultaneously with high resolution, owing to the curvature in the wavefront from NA-matching illuminations and the finite beam angle of the Lambertian LED light source. Here, we introduce an illumination framework tailored for APIC consisting of a distant annular LED ring and an LED dome that enables the reconstruction of a larger area with an extended synthetic numerical aperture, consequently enhancing resolution. For a single set of measurements, our new prototype, termed Dome-APIC can reach 620nm resolution with a 10×/0.25 NA objective lens over a field-of-view of 450 µm x 450 µm.
- 6 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 5739-5755
Efficient, gigapixel-scale, aberration-free whole slide scanner using angular ptychographic imaging with closed-form solution
Whole slide imaging provides a wide field-of-view (FOV) across cross-sections of biopsy or surgery samples, significantly facilitating pathological analysis and clinical diagnosis. Such high-quality images that enable detailed visualization of cellular and tissue structures are essential for effective patient care and treatment planning. To obtain such high-quality images for pathology applications, there is a need for scanners with high spatial bandwidth products, free from aberrations, and without the requirement for z-scanning. Here we report a whole slide imaging system based on angular ptychographic imaging with a closed-form solution (WSI-APIC), which offers efficient, tens-of-gigapixels, large-FOV, aberration-free imaging. WSI-APIC utilizes oblique incoherent illumination for initial high-level segmentation, thereby bypassing unnecessary scanning of the background regions and enhancing image acquisition efficiency. A GPU-accelerated APIC algorithm analytically reconstructs phase images with effective digital aberration corrections and improved optical resolutions. Moreover, an auto-stitching technique based on scale-invariant feature transform ensures the seamless concatenation of whole slide phase images. In our experiment, WSI-APIC achieved an optical resolution of 772 nm using a 10×/0.25 NA objective lens and captures 80-gigapixel aberration-free phase images for a standard 76.2 mm × 25.4 mm microscopic slide.
- 6 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 5739-5755
Efficient, gigapixel-scale, aberration-free whole slide scanner using angular ptychographic imaging with closed-form solution
Whole slide imaging provides a wide field-of-view (FOV) across cross-sections of biopsy or surgery samples, significantly facilitating pathological analysis and clinical diagnosis. Such high-quality images that enable detailed visualization of cellular and tissue structures are essential for effective patient care and treatment planning. To obtain such high-quality images for pathology applications, there is a need for scanners with high spatial bandwidth products, free from aberrations, and without the requirement for z-scanning. Here we report a whole slide imaging system based on angular ptychographic imaging with a closed-form solution (WSI-APIC), which offers efficient, tens-of-gigapixels, large-FOV, aberration-free imaging. WSI-APIC utilizes oblique incoherent illumination for initial high-level segmentation, thereby bypassing unnecessary scanning of the background regions and enhancing image acquisition efficiency. A GPU-accelerated APIC algorithm analytically reconstructs phase images with effective digital aberration corrections and improved optical resolutions. Moreover, an auto-stitching technique based on scale-invariant feature transform ensures the seamless concatenation of whole slide phase images. In our experiment, WSI-APIC achieved an optical resolution of 772 nm using a 10×/0.25 NA objective lens and captures 80-gigapixel aberration-free phase images for a standard 76.2 mm × 25.4 mm microscopic slide.
- 26 June 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (14) , 25036-25045
Can deep neural networks work with amplitude and phase input of defocused images?
Deep neural network (DNN) models, particularly convolutional neural networks (CNNs), have demonstrated remarkable performance in biomedical image classification due to their ability to automatically learn features from large datasets. One common challenge in the preparation of large, microscopic datasets for DNN tasks is sample defocusing, potentially impairing the model performance. To handle defocusing, computational imaging, or specifically quantitative phase imaging (QPI), performs digital refocusing by using both the phase and the amplitude of the complex optical field. This leads us to investigate whether feeding the complex field into DNN would potentially address the defocusing problem as in-focus information is implicitly encoded in the complex field. In this paper, we assess the feasibility of employing neural networks to directly process full amplitude and phase data from a defocus plane without digital refocusing. Our specific focus lies in understanding the tolerance for defocus in image classification neural networks when amplitude and phase are taken as inputs. To accomplish this, we used Fourier ptychography microscopy (FPM) to acquire in-focus phase and amplitude images of two distinct object types – normal red blood cells and echinocytes. We then digitally propagate the complex field to generate progressively defocused images of the samples to serve as training and testing datasets for image classification neural networks. While the digitally defocused images contain sufficient information to recover the original in-focus images, we observed that current standard implementations of deep learning models are unable to effectively utilize the defocused field to distinguish between the two cell types. We conclude that the physical-model-based digital refocusing capability of QPI remains indispensable for overcoming defocusing issues in current standard DNN models.
- 26 June 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (14) , 25036-25045
Can deep neural networks work with amplitude and phase input of defocused images?
Deep neural network (DNN) models, particularly convolutional neural networks (CNNs), have demonstrated remarkable performance in biomedical image classification due to their ability to automatically learn features from large datasets. One common challenge in the preparation of large, microscopic datasets for DNN tasks is sample defocusing, potentially impairing the model performance. To handle defocusing, computational imaging, or specifically quantitative phase imaging (QPI), performs digital refocusing by using both the phase and the amplitude of the complex optical field. This leads us to investigate whether feeding the complex field into DNN would potentially address the defocusing problem as in-focus information is implicitly encoded in the complex field. In this paper, we assess the feasibility of employing neural networks to directly process full amplitude and phase data from a defocus plane without digital refocusing. Our specific focus lies in understanding the tolerance for defocus in image classification neural networks when amplitude and phase are taken as inputs. To accomplish this, we used Fourier ptychography microscopy (FPM) to acquire in-focus phase and amplitude images of two distinct object types – normal red blood cells and echinocytes. We then digitally propagate the complex field to generate progressively defocused images of the samples to serve as training and testing datasets for image classification neural networks. While the digitally defocused images contain sufficient information to recover the original in-focus images, we observed that current standard implementations of deep learning models are unable to effectively utilize the defocused field to distinguish between the two cell types. We conclude that the physical-model-based digital refocusing capability of QPI remains indispensable for overcoming defocusing issues in current standard DNN models.
- Open Access
- 3 June 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
High-resolution, large field-of-view label-free imaging via aberration-corrected, closed-form complex field reconstruction
Computational imaging methods empower modern microscopes to produce high-resolution, large field-of-view, aberration-free images. Fourier ptychographic microscopy can increase the space-bandwidth product of conventional microscopy, but its iterative reconstruction methods are prone to parameter selection and tend to fail under excessive aberrations. Spatial Kramers–Kronig methods can analytically reconstruct complex fields, but is limited by aberration or providing extended resolution enhancement. Here, we present APIC, a closed-form method that weds the strengths of both methods while using only NA-matching and darkfield measurements. We establish an analytical phase retrieval framework which demonstrates the feasibility of analytically reconstructing the complex field associated with darkfield measurements. APIC can retrieve complex aberrations of an imaging system with no additional hardware and avoids iterative algorithms, requiring no human-designed convergence metrics while always obtaining a closed-form complex field solution. We experimentally demonstrate that APIC gives correct reconstruction results where Fourier ptychographic microscopy fails when constrained to the same number of measurements. APIC achieves 2.8 times faster computation using image tile size of 256 (length-wise), is robust against aberrations compared to Fourier ptychographic microscopy, and capable of addressing aberrations whose maximal phase difference exceeds 3.8π when using a NA 0.25 objective in experiment.
- 3 June 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
Open AccessHigh-resolution, large field-of-view label-free imaging via aberration-corrected, closed-form complex field reconstruction
Computational imaging methods empower modern microscopes to produce high-resolution, large field-of-view, aberration-free images. Fourier ptychographic microscopy can increase the space-bandwidth product of conventional microscopy, but its iterative reconstruction methods are prone to parameter selection and tend to fail under excessive aberrations. Spatial Kramers–Kronig methods can analytically reconstruct complex fields, but is limited by aberration or providing extended resolution enhancement. Here, we present APIC, a closed-form method that weds the strengths of both methods while using only NA-matching and darkfield measurements. We establish an analytical phase retrieval framework which demonstrates the feasibility of analytically reconstructing the complex field associated with darkfield measurements. APIC can retrieve complex aberrations of an imaging system with no additional hardware and avoids iterative algorithms, requiring no human-designed convergence metrics while always obtaining a closed-form complex field solution. We experimentally demonstrate that APIC gives correct reconstruction results where Fourier ptychographic microscopy fails when constrained to the same number of measurements. APIC achieves 2.8 times faster computation using image tile size of 256 (length-wise), is robust against aberrations compared to Fourier ptychographic microscopy, and capable of addressing aberrations whose maximal phase difference exceeds 3.8π when using a NA 0.25 objective in experiment.
- Top Cited Papers
- 30 May 2022
- Published by Springer Nature in Nature Photonics
- Vol. 16 (6) , 462-468
High-resolution non-line-of-sight imaging employing active focusing
- 30 May 2022
- Published by Springer Nature in Nature Photonics
- Vol. 16 (6) , 462-468
Top Cited PapersHigh-resolution non-line-of-sight imaging employing active focusing
- Open Access
- 2 March 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 29
Non-line-of-sight imaging via wavefront shaping
SPIE Digital Library Proceedings
- 2 March 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 29
Open AccessNon-line-of-sight imaging via wavefront shaping
SPIE Digital Library Proceedings
- 20 May 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (11) , 2973-2976
Imaging through highly scattering human skulls with ultrasound-modulated optical tomography
Advances in human brain imaging technologies are critical to understanding how the brain works and the diagnosis of brain disorders. Existing technologies have different drawbacks, and the human skull poses a great challenge for pure optical and ultrasound imaging technologies. Here we demonstrate the feasibility of using ultrasound-modulated optical tomography, a hybrid technology that combines both light and sound, to image through human skulls. Single-shot off-axis holography was used to measure the field of the ultrasonically tagged light. This Letter paves the way for imaging the brain noninvasively through the skull, with optical contrast and a higher spatial resolution than that of diffuse optical tomography.
- 20 May 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (11) , 2973-2976
Imaging through highly scattering human skulls with ultrasound-modulated optical tomography
Advances in human brain imaging technologies are critical to understanding how the brain works and the diagnosis of brain disorders. Existing technologies have different drawbacks, and the human skull poses a great challenge for pure optical and ultrasound imaging technologies. Here we demonstrate the feasibility of using ultrasound-modulated optical tomography, a hybrid technology that combines both light and sound, to image through human skulls. Single-shot off-axis holography was used to measure the field of the ultrasonically tagged light. This Letter paves the way for imaging the brain noninvasively through the skull, with optical contrast and a higher spatial resolution than that of diffuse optical tomography.
- 18 March 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (7) , 1734-1737
Single-shot surface 3D imaging by optical coherence factor
We report a single-shot three-dimensional (3D) topographical imaging method, optical coherence factor (OCF) imaging, which uses optical coherence as the contrast mechanism to acquire the surface height ( z -direction) information of an object. A 4-f imaging system records the light field reflected from the surface of the object. The illumination of the imaging system comes from a laser source with the optical coherence length comparable to the depth of field (DoF) of the optical system. Off-axis holographic recording is used to retrieve the coherence factor from the interference fringes, which is then converted to z -direction information. In this experiment, we validate our 3D imaging results comparing them to axial scanning full-field optical coherence tomography images. We also analyze the contrast mechanism of OCF and show that it is able to provide additional information over conventional coherent and incoherent imaging using the same imaging setup. This single-shot computationally efficient method may have potential applications in industrial quality control inspection.
- 18 March 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (7) , 1734-1737
Single-shot surface 3D imaging by optical coherence factor
We report a single-shot three-dimensional (3D) topographical imaging method, optical coherence factor (OCF) imaging, which uses optical coherence as the contrast mechanism to acquire the surface height ( z -direction) information of an object. A 4-f imaging system records the light field reflected from the surface of the object. The illumination of the imaging system comes from a laser source with the optical coherence length comparable to the depth of field (DoF) of the optical system. Off-axis holographic recording is used to retrieve the coherence factor from the interference fringes, which is then converted to z -direction information. In this experiment, we validate our 3D imaging results comparing them to axial scanning full-field optical coherence tomography images. We also analyze the contrast mechanism of OCF and show that it is able to provide additional information over conventional coherent and incoherent imaging using the same imaging setup. This single-shot computationally efficient method may have potential applications in industrial quality control inspection.