Nastaran Emaminejad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nastaran Emaminejad has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Wei Qian
The Univ. of Texas at El Paso (United States)
4 shared publicationsYubao Guan
Guangzhou Medical Univ. (China)
4 shared publicationsBin Zheng
The Univ. of Oklahoma (United States)
3 shared publicationsGrace H. Kim
Department of Radiological Sciences David Geffen School of Medicine at UCLA Los Angeles CA 90024 USA
3 shared publicationsFleming Lure
The Univ. of Texas at El Paso (United States)
2 shared publicationsMatthew S. Brown
Univ. of California, Los Angeles (United States)
2 shared publications
Latest Publications
- 24 January 2019
- Published by Wiley in Medical Physics
- Vol. 46 (5) , 2310-2322
Technical Note: Design and implementation of a high‐throughput pipeline for reconstruction and quantitative analysis of CT image data
Purpose: With recent substantial improvements in modern computing, interest in quantitative imaging with CT has seen a dramatic increase. As a result, the need to both create and analyze large, high‐quality datasets of clinical studies has increased as well. At present, no efficient, widely available method exists to accomplish this. The purpose of this technical note is to describe an open‐source high‐throughput computational pipeline framework for the reconstruction and analysis of diagnostic CT imaging data to conduct large‐scale quantitative imaging studies and to accelerate and improve quantitative imaging research.Methods: The pipeline consists of two, primary “blocks”: reconstruction and analysis. Reconstruction is carried out via a graphics processing unit (GPU) queuing framework developed specifically for the pipeline that allows a dataset to be reconstructed using a variety of different parameter configurations such as slice thickness, reconstruction kernel, and simulated acquisition dose. The analysis portion then automatically analyzes the output of the reconstruction using “modules” that can be combined in various ways to conduct different experiments. Acceleration of analysis is achieved using cluster processing. Efficiency and performance of the pipeline are demonstrated using an example 142 subject lung screening cohort reconstructed 36 different ways and analyzed using quantitative emphysema scoring techniques.Results: The pipeline reconstructed and analyzed the 5112 reconstructed datasets in approximately 10 days, a roughly 72× speedup over previous efforts using the scanner for reconstructions. Tightly coupled pipeline quality assurance software ensured proper performance of analysis modules with regard to segmentation and emphysema scoring.Conclusions: The pipeline greatly reduced the time from experiment conception to quantitative results. The modular design of the pipeline allows the high‐throughput framework to be utilized for other future experiments into different quantitative imaging techniques. Future applications of the pipeline being explored are robustness testing of quantitative imaging metrics, data generation for deep learning, and use as a test platform for image‐processing techniques to improve clinical quantitative imaging.
- 24 January 2019
- Published by Wiley in Medical Physics
- Vol. 46 (5) , 2310-2322
Technical Note: Design and implementation of a high‐throughput pipeline for reconstruction and quantitative analysis of CT image data
Purpose: With recent substantial improvements in modern computing, interest in quantitative imaging with CT has seen a dramatic increase. As a result, the need to both create and analyze large, high‐quality datasets of clinical studies has increased as well. At present, no efficient, widely available method exists to accomplish this. The purpose of this technical note is to describe an open‐source high‐throughput computational pipeline framework for the reconstruction and analysis of diagnostic CT imaging data to conduct large‐scale quantitative imaging studies and to accelerate and improve quantitative imaging research.Methods: The pipeline consists of two, primary “blocks”: reconstruction and analysis. Reconstruction is carried out via a graphics processing unit (GPU) queuing framework developed specifically for the pipeline that allows a dataset to be reconstructed using a variety of different parameter configurations such as slice thickness, reconstruction kernel, and simulated acquisition dose. The analysis portion then automatically analyzes the output of the reconstruction using “modules” that can be combined in various ways to conduct different experiments. Acceleration of analysis is achieved using cluster processing. Efficiency and performance of the pipeline are demonstrated using an example 142 subject lung screening cohort reconstructed 36 different ways and analyzed using quantitative emphysema scoring techniques.Results: The pipeline reconstructed and analyzed the 5112 reconstructed datasets in approximately 10 days, a roughly 72× speedup over previous efforts using the scanner for reconstructions. Tightly coupled pipeline quality assurance software ensured proper performance of analysis modules with regard to segmentation and emphysema scoring.Conclusions: The pipeline greatly reduced the time from experiment conception to quantitative results. The modular design of the pipeline allows the high‐throughput framework to be utilized for other future experiments into different quantitative imaging techniques. Future applications of the pipeline being explored are robustness testing of quantitative imaging metrics, data generation for deep learning, and use as a test platform for image‐processing techniques to improve clinical quantitative imaging.
- 2 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10575, 105753W
The effects of variations in parameters and algorithm choices on calculated radiomics feature values: initial investigations and comparisons to feature variability across CT image acquisition conditions
Translation of radiomics into clinical practice requires confidence in its interpretations. This may be obtained via understanding and overcoming the limitations in current radiomic approaches. Currently there is a lack of standardization in radiomic feature extraction. In this study we examined a few factors that are potential sources of inconsistency in characterizing lung nodules, such as 1)different choices of parameters and algorithms in feature calculation, 2)two CT image dose levels, 3)different CT reconstruction algorithms (WFBP, denoised WFBP, and Iterative). We investigated the effect of variation of these factors on entropy textural feature of lung nodules. CT images of 19 lung nodules identified from our lung cancer screening program were identified by a CAD tool and contours provided. The radiomics features were extracted by calculating 36 GLCM based and 4 histogram based entropy features in addition to 2 intensity based features. A robustness index was calculated across different image acquisition parameters to illustrate the reproducibility of features. Most GLCM based and all histogram based entropy features were robust across two CT image dose levels. Denoising of images slightly improved robustness of some entropy features at WFBP. Iterative reconstruction resulted in improvement of robustness in a fewer times and caused more variation in entropy feature values and their robustness. Within different choices of parameters and algorithms texture features showed a wide range of variation, as much as 75% for individual nodules. Results indicate the need for harmonization of feature calculations and identification of optimum parameters and algorithms in a radiomics study.
- 2 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10575, 105753W
The effects of variations in parameters and algorithm choices on calculated radiomics feature values: initial investigations and comparisons to feature variability across CT image acquisition conditions
Translation of radiomics into clinical practice requires confidence in its interpretations. This may be obtained via understanding and overcoming the limitations in current radiomic approaches. Currently there is a lack of standardization in radiomic feature extraction. In this study we examined a few factors that are potential sources of inconsistency in characterizing lung nodules, such as 1)different choices of parameters and algorithms in feature calculation, 2)two CT image dose levels, 3)different CT reconstruction algorithms (WFBP, denoised WFBP, and Iterative). We investigated the effect of variation of these factors on entropy textural feature of lung nodules. CT images of 19 lung nodules identified from our lung cancer screening program were identified by a CAD tool and contours provided. The radiomics features were extracted by calculating 36 GLCM based and 4 histogram based entropy features in addition to 2 intensity based features. A robustness index was calculated across different image acquisition parameters to illustrate the reproducibility of features. Most GLCM based and all histogram based entropy features were robust across two CT image dose levels. Denoising of images slightly improved robustness of some entropy features at WFBP. Iterative reconstruction resulted in improvement of robustness in a fewer times and caused more variation in entropy feature values and their robustness. Within different choices of parameters and algorithms texture features showed a wide range of variation, as much as 75% for individual nodules. Results indicate the need for harmonization of feature calculations and identification of optimum parameters and algorithms in a radiomics study.
- 27 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10134, 101340
The effects of slice thickness and radiation dose level variations on computer-aided diagnosis (CAD) nodule detection performance in pediatric chest CT scans
For pediatric oncology patients, CT scans are performed to assess treatment response and disease progression. CAD may be used to detect lung nodules which would reflect metastatic disease. The purpose of this study was to investigate the effects of reducing radiation dose and varying slice thickness on CAD performance in the detection of solid lung nodules in pediatric patients. The dataset consisted of CT scans of 58 pediatric chest cases, from which 7 cases had lung nodules detected by radiologist, and a total of 28 nodules were marked. For each case, the original raw data (sinogram data) was collected and a noise addition model was used to simulate reduced-dose scans of 50%, 25% and 10% of the original dose. In addition, the original and reduced-dose raw data were reconstructed at slice thicknesses of 1.5 and 3 mm using a medium sharp (B45) kernel; the result was eight datasets (4 dose levels x 2 thicknesses) for each case An in-house CAD tool was applied on all reconstructed scans, and results were compared with the radiologist’s markings. Patient level mean sensitivities at 3mm thickness were 24%, 26%, 25%, 27%, and at 1.5 mm thickness were 23%, 29%, 35%, 36% for 10%, 25%, 50%, and 100% dose level, respectively. Mean FP numbers were 1.5, 0.9, 0.8, 0.7 at 3 mm and 11.4, 3.5, 2.8, 2.8 at 1.5 mm thickness for 10%, 25%, 50%, and 100% dose level respectively. CAD sensitivity did not change with dose level for 3mm thickness, but did change with dose for 1.5 mm. False Positives increased at low dose levels where noise values were high. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 27 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10134, 101340
The effects of slice thickness and radiation dose level variations on computer-aided diagnosis (CAD) nodule detection performance in pediatric chest CT scans
For pediatric oncology patients, CT scans are performed to assess treatment response and disease progression. CAD may be used to detect lung nodules which would reflect metastatic disease. The purpose of this study was to investigate the effects of reducing radiation dose and varying slice thickness on CAD performance in the detection of solid lung nodules in pediatric patients. The dataset consisted of CT scans of 58 pediatric chest cases, from which 7 cases had lung nodules detected by radiologist, and a total of 28 nodules were marked. For each case, the original raw data (sinogram data) was collected and a noise addition model was used to simulate reduced-dose scans of 50%, 25% and 10% of the original dose. In addition, the original and reduced-dose raw data were reconstructed at slice thicknesses of 1.5 and 3 mm using a medium sharp (B45) kernel; the result was eight datasets (4 dose levels x 2 thicknesses) for each case An in-house CAD tool was applied on all reconstructed scans, and results were compared with the radiologist’s markings. Patient level mean sensitivities at 3mm thickness were 24%, 26%, 25%, 27%, and at 1.5 mm thickness were 23%, 29%, 35%, 36% for 10%, 25%, 50%, and 100% dose level, respectively. Mean FP numbers were 1.5, 0.9, 0.8, 0.7 at 3 mm and 11.4, 3.5, 2.8, 2.8 at 1.5 mm thickness for 10%, 25%, 50%, and 100% dose level respectively. CAD sensitivity did not change with dose level for 3mm thickness, but did change with dose for 1.5 mm. False Positives increased at low dose levels where noise values were high. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 24 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9785, 97851E
Applying a radiomics approach to predict prognosis of lung cancer patients
Radiomics is an emerging technology to decode tumor phenotype based on quantitative analysis of image features computed from radiographic images. In this study, we applied Radiomics concept to investigate the association among the CT image features of lung tumors, which are either quantitatively computed or subjectively rated by radiologists, and two genomic biomarkers namely, protein expression of the excision repair cross-complementing 1 (ERCC1) genes and a regulatory subunit of ribonucleotide reductase (RRM1), in predicting disease-free survival (DFS) of lung cancer patients after surgery. An image dataset involving 94 patients was used. Among them, 20 had cancer recurrence within 3 years, while 74 patients remained DFS. After tumor segmentation, 35 image features were computed from CT images. Using the Weka data mining software package, we selected 10 non-redundant image features. Applying a SMOTE algorithm to generate synthetic data to balance case numbers in two DFS (“yes” and “no”) groups and a leave-one-case-out training/testing method, we optimized and compared a number of machine learning classifiers using (1) quantitative image (QI) features, (2) subjective rated (SR) features, and (3) genomic biomarkers (GB). Data analyses showed relatively lower correlation among the QI, SR and GB prediction results (with Pearson correlation coefficients < 0.5 including between ERCC1 and RRM1 biomarkers). By using area under ROC curve as an assessment index, the QI, SR and GB based classifiers yielded AUC = 0.89±0.04, 0.73±0.06 and 0.76±0.07, respectively, which showed that all three types of features had prediction power (AUC>0.5). Among them, using QI yielded the highest performance.
- 24 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9785, 97851E
Applying a radiomics approach to predict prognosis of lung cancer patients
Radiomics is an emerging technology to decode tumor phenotype based on quantitative analysis of image features computed from radiographic images. In this study, we applied Radiomics concept to investigate the association among the CT image features of lung tumors, which are either quantitatively computed or subjectively rated by radiologists, and two genomic biomarkers namely, protein expression of the excision repair cross-complementing 1 (ERCC1) genes and a regulatory subunit of ribonucleotide reductase (RRM1), in predicting disease-free survival (DFS) of lung cancer patients after surgery. An image dataset involving 94 patients was used. Among them, 20 had cancer recurrence within 3 years, while 74 patients remained DFS. After tumor segmentation, 35 image features were computed from CT images. Using the Weka data mining software package, we selected 10 non-redundant image features. Applying a SMOTE algorithm to generate synthetic data to balance case numbers in two DFS (“yes” and “no”) groups and a leave-one-case-out training/testing method, we optimized and compared a number of machine learning classifiers using (1) quantitative image (QI) features, (2) subjective rated (SR) features, and (3) genomic biomarkers (GB). Data analyses showed relatively lower correlation among the QI, SR and GB prediction results (with Pearson correlation coefficients < 0.5 including between ERCC1 and RRM1 biomarkers). By using area under ROC curve as an assessment index, the QI, SR and GB based classifiers yielded AUC = 0.89±0.04, 0.73±0.06 and 0.76±0.07, respectively, which showed that all three types of features had prediction power (AUC>0.5). Among them, using QI yielded the highest performance.
- 14 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (5) , 1034-1043
Fusion of Quantitative Image and Genomic Biomarkers to Improve Prognosis Assessment of Early Stage Lung Cancer Patients
Objective: This study aims to develop a new quantitative image feature analysis scheme and investigate its role along with two genomic biomarkers, namely protein expression of the excision repair cross-complementing 1 genes and a regulatory subunit of ribonucleotide reductase (RRM1), in predicting cancer recurrence risk of stage I nonsmall-cell lung cancer (NSCLC) patients after surgery. Methods: By using chest computed tomography images, we developed a computer-aided detection scheme to segment lung tumors and computed tumor-related image features. After feature selection, we trained a Naïve Bayesian network-based classifier using eight image features and a multilayer perceptron classifier using two genomic biomarkers to predict cancer recurrence risk, respectively. Two classifiers were trained and tested using a dataset with 79 stage I NSCLC cases, a synthetic minority oversampling technique and a leave-one-case-out validation method. A fusion method was also applied to combine prediction scores of two classifiers. Results: Areas under ROC curves (AUC) values are 0.78 ± 0.06 and 0.68 ± 0.07 when using the image feature and genomic biomarker-based classifiers, respectively. AUC value significantly increased to 0.84 ± 0.05 (p <; 0.05) when fusion of two classifier-generated prediction scores using an equal weighting factor. Conclusion: A quantitative image feature-based classifier yielded significantly higher discriminatory power than a genomic biomarker-based classifier in predicting cancer recurrence risk. Fusion of prediction scores generated by the two classifiers further improved prediction performance. Significance: We demonstrated a new approach that has potential to assist clinicians in more effectively managing stage I NSCLC patients to reduce cancer recurrence risk.
- 14 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (5) , 1034-1043
Fusion of Quantitative Image and Genomic Biomarkers to Improve Prognosis Assessment of Early Stage Lung Cancer Patients
Objective: This study aims to develop a new quantitative image feature analysis scheme and investigate its role along with two genomic biomarkers, namely protein expression of the excision repair cross-complementing 1 genes and a regulatory subunit of ribonucleotide reductase (RRM1), in predicting cancer recurrence risk of stage I nonsmall-cell lung cancer (NSCLC) patients after surgery. Methods: By using chest computed tomography images, we developed a computer-aided detection scheme to segment lung tumors and computed tumor-related image features. After feature selection, we trained a Naïve Bayesian network-based classifier using eight image features and a multilayer perceptron classifier using two genomic biomarkers to predict cancer recurrence risk, respectively. Two classifiers were trained and tested using a dataset with 79 stage I NSCLC cases, a synthetic minority oversampling technique and a leave-one-case-out validation method. A fusion method was also applied to combine prediction scores of two classifiers. Results: Areas under ROC curves (AUC) values are 0.78 ± 0.06 and 0.68 ± 0.07 when using the image feature and genomic biomarker-based classifiers, respectively. AUC value significantly increased to 0.84 ± 0.05 (p <; 0.05) when fusion of two classifier-generated prediction scores using an equal weighting factor. Conclusion: A quantitative image feature-based classifier yielded significantly higher discriminatory power than a genomic biomarker-based classifier in predicting cancer recurrence risk. Fusion of prediction scores generated by the two classifiers further improved prediction performance. Significance: We demonstrated a new approach that has potential to assist clinicians in more effectively managing stage I NSCLC patients to reduce cancer recurrence risk.
- 20 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9414, 94141M
Exploring new quantitative CT image features to improve assessment of lung cancer prognosis
Due to the promotion of lung cancer screening, more Stage I non-small-cell lung cancers (NSCLC) are currently detected, which usually have favorable prognosis. However, a high percentage of the patients have cancer recurrence after surgery, which reduces overall survival rate. To achieve optimal efficacy of treating and managing Stage I NSCLC patients, it is important to develop more accurate and reliable biomarkers or tools to predict cancer prognosis. The purpose of this study is to investigate a new quantitative image analysis method to predict the risk of lung cancer recurrence of Stage I NSCLC patients after the lung cancer surgery using the conventional chest computed tomography (CT) images and compare the prediction result with a popular genetic biomarker namely, protein expression of the excision repair cross-complementing 1 (ERCC1) genes. In this study, we developed and tested a new computer-aided detection (CAD) scheme to segment lung tumors and initially compute 35 tumor-related morphologic and texture features from CT images. By applying a machine learning based feature selection method, we identified a set of 8 effective and non-redundant image features. Using these features we trained a naïve Bayesian network based classifier to predict the risk of cancer recurrence. When applying to a test dataset with 79 Stage I NSCLC cases, the computed areas under ROC curves were 0.77±0.06 and 0.63±0.07 when using the quantitative image based classifier and ERCC1, respectively. The study results demonstrated the feasibility of improving accuracy of predicting cancer prognosis or recurrence risk using a CAD-based quantitative image analysis method.
- 20 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9414, 94141M
Exploring new quantitative CT image features to improve assessment of lung cancer prognosis
Due to the promotion of lung cancer screening, more Stage I non-small-cell lung cancers (NSCLC) are currently detected, which usually have favorable prognosis. However, a high percentage of the patients have cancer recurrence after surgery, which reduces overall survival rate. To achieve optimal efficacy of treating and managing Stage I NSCLC patients, it is important to develop more accurate and reliable biomarkers or tools to predict cancer prognosis. The purpose of this study is to investigate a new quantitative image analysis method to predict the risk of lung cancer recurrence of Stage I NSCLC patients after the lung cancer surgery using the conventional chest computed tomography (CT) images and compare the prediction result with a popular genetic biomarker namely, protein expression of the excision repair cross-complementing 1 (ERCC1) genes. In this study, we developed and tested a new computer-aided detection (CAD) scheme to segment lung tumors and initially compute 35 tumor-related morphologic and texture features from CT images. By applying a machine learning based feature selection method, we identified a set of 8 effective and non-redundant image features. Using these features we trained a naïve Bayesian network based classifier to predict the risk of cancer recurrence. When applying to a test dataset with 79 Stage I NSCLC cases, the computed areas under ROC curves were 0.77±0.06 and 0.63±0.07 when using the quantitative image based classifier and ERCC1, respectively. The study results demonstrated the feasibility of improving accuracy of predicting cancer prognosis or recurrence risk using a CAD-based quantitative image analysis method.
- 11 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9037, 90371Q
Evaluation of correlation between CT image features and ERCC1 protein expression in assessing lung cancer prognosis
Stage I non-small-cell lung cancers (NSCLC) usually have favorable prognosis. However, high percentage of NSCLC patients have cancer relapse after surgery. Accurately predicting cancer prognosis is important to optimally treat and manage the patients to minimize the risk of cancer relapse. Studies have shown that an excision repair crosscomplementing 1 (ERCC1) gene was a potentially useful genetic biomarker to predict prognosis of NSCLC patients. Meanwhile, studies also found that chronic obstructive pulmonary disease (COPD) was highly associated with lung cancer prognosis. In this study, we investigated and evaluated the correlations between COPD image features and ERCC1 gene expression. A database involving 106 NSCLC patients was used. Each patient had a thoracic CT examination and ERCC1 genetic test. We applied a computer-aided detection scheme to segment and quantify COPD image features. A logistic regression method and a multilayer perceptron network were applied to analyze the correlation between the computed COPD image features and ERCC1 protein expression. A multilayer perceptron network (MPN) was also developed to test performance of using COPD-related image features to predict ERCC1 protein expression. A nine feature based logistic regression analysis showed the average COPD feature values in the low and high ERCC1 protein expression groups are significantly different (p < 0.01). Using a five-fold cross validation method, the MPN yielded an area under ROC curve (AUC = 0.669±0.053) in classifying between the low and high ERCC1 expression cases. The study indicates that CT phenotype features are associated with the genetic tests, which may provide supplementary information to help improve accuracy in assessing prognosis of NSCLC patients.
- 11 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9037, 90371Q
Evaluation of correlation between CT image features and ERCC1 protein expression in assessing lung cancer prognosis
Stage I non-small-cell lung cancers (NSCLC) usually have favorable prognosis. However, high percentage of NSCLC patients have cancer relapse after surgery. Accurately predicting cancer prognosis is important to optimally treat and manage the patients to minimize the risk of cancer relapse. Studies have shown that an excision repair crosscomplementing 1 (ERCC1) gene was a potentially useful genetic biomarker to predict prognosis of NSCLC patients. Meanwhile, studies also found that chronic obstructive pulmonary disease (COPD) was highly associated with lung cancer prognosis. In this study, we investigated and evaluated the correlations between COPD image features and ERCC1 gene expression. A database involving 106 NSCLC patients was used. Each patient had a thoracic CT examination and ERCC1 genetic test. We applied a computer-aided detection scheme to segment and quantify COPD image features. A logistic regression method and a multilayer perceptron network were applied to analyze the correlation between the computed COPD image features and ERCC1 protein expression. A multilayer perceptron network (MPN) was also developed to test performance of using COPD-related image features to predict ERCC1 protein expression. A nine feature based logistic regression analysis showed the average COPD feature values in the low and high ERCC1 protein expression groups are significantly different (p < 0.01). Using a five-fold cross validation method, the MPN yielded an area under ROC curve (AUC = 0.669±0.053) in classifying between the low and high ERCC1 expression cases. The study indicates that CT phenotype features are associated with the genetic tests, which may provide supplementary information to help improve accuracy in assessing prognosis of NSCLC patients.