Technical Note: Design and implementation of a high‐throughput pipeline for reconstruction and quantitative analysis of CT image data
- 24 January 2019
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 46 (5) , 2310-2322
Abstract
Purpose: With recent substantial improvements in modern computing, interest in quantitative imaging with CT has seen a dramatic increase. As a result, the need to both create and analyze large, high‐quality datasets of clinical studies has increased as well. At present, no efficient, widely available method exists to accomplish this. The purpose of this technical note is to describe an open‐source high‐throughput computational pipeline framework for the reconstruction and analysis of diagnostic CT imaging data to conduct large‐scale quantitative imaging studies and to accelerate and improve quantitative imaging research.Methods: The pipeline consists of two, primary “blocks”: reconstruction and analysis. Reconstruction is carried out via a graphics processing unit (GPU) queuing framework developed specifically for the pipeline that allows a dataset to be reconstructed using a variety of different parameter configurations such as slice thickness, reconstruction kernel, and simulated acquisition dose. The analysis portion then automatically analyzes the output of the reconstruction using “modules” that can be combined in various ways to conduct different experiments. Acceleration of analysis is achieved using cluster processing. Efficiency and performance of the pipeline are demonstrated using an example 142 subject lung screening cohort reconstructed 36 different ways and analyzed using quantitative emphysema scoring techniques.Results: The pipeline reconstructed and analyzed the 5112 reconstructed datasets in approximately 10 days, a roughly 72× speedup over previous efforts using the scanner for reconstructions. Tightly coupled pipeline quality assurance software ensured proper performance of analysis modules with regard to segmentation and emphysema scoring.Conclusions: The pipeline greatly reduced the time from experiment conception to quantitative results. The modular design of the pipeline allows the high‐throughput framework to be utilized for other future experiments into different quantitative imaging techniques. Future applications of the pipeline being explored are robustness testing of quantitative imaging metrics, data generation for deep learning, and use as a test platform for image‐processing techniques to improve clinical quantitative imaging.Keywords
Funding Information
- California Tobacco Related Disease Research Program (22RT-0131)
- NCI's Quantitative Imaging Network (U01 CA181156)
This publication has 26 references indexed in Scilit:
- Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstructionEuropean Radiology, 2013
- A low dose simulation tool for CT systems with energy integrating detectorsMedical Physics, 2013
- Emphysema Quantification by Low-Dose CT: Potential Impact of Adaptive Iterative Dose Reduction Using 3D ProcessingAmerican Journal of Roentgenology, 2012
- The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensionsEuropean Radiology, 2012
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic ScreeningThe New England journal of medicine, 2011
- The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT ScansMedical Physics, 2011
- Effects of CT Section Thickness and Reconstruction Kernel on Emphysema QuantificationAcademic Radiology, 2010
- Comparison of Standard- and Low-Radiation-Dose CT for Quantification of EmphysemaAmerican Journal of Roentgenology, 2007
- Emphysema: Effect of Reconstruction Algorithm on CT Imaging MeasuresRadiology, 2004
- “Density Mask”Chest, 1988