Zygfryd Domachowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zygfryd Domachowski has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Marek Dzida
Gdansk University of Technology , Gdansk , Poland
5 shared publications Marek Dzida
Technical University of Gdańsk, Gdańsk, Poland
1 shared publication- Mohammad Hossein Ghaemi
Faculty of Mechanical Eng. And Ship Technology , Gdańsk University of Technology , Gdansk , Poland
1 shared publication W. Próchnicki
Technical University of Gdansk, Narutowicza 11/12, 80-952 Gdansk, Poland tel. (48 58) 3472662, fax: (48 58) 3414712
1 shared publicationZ. Puhaczewski
Technical University of Gdansk, Narutowicza 11/12, 80-952 Gdansk, Poland tel. (48 58) 3472662, fax: (48 58) 3414712
1 shared publication
Latest Publications
- Open Access
- 1 December 2015
- Published by Walter de Gruyter GmbH in Polish Maritime Research
- Vol. 22 (4) , 53-58
Inlet Air Fogging of Marine Gas Turbine in Power Output Loss Compensation
The use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in literature [1]. This paper will cover some considerations relating to its application for gas turbines in ship drive. There is an important evaporative cooling potential throughout the world, when the dynamic data is evaluated, based on an analysis of coincident wet and dry bulb information. This data will allow ships’ gas turbine operators to make an assessment of the economics of evaporative fogging. The paper represents an introduction to the methodology and data analysis to derive the direct evaporative cooling potential to be used in marine gas turbine power output loss compensation.
- 1 December 2015
- Published by Walter de Gruyter GmbH in Polish Maritime Research
- Vol. 22 (4) , 53-58
Open AccessInlet Air Fogging of Marine Gas Turbine in Power Output Loss Compensation
The use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in literature [1]. This paper will cover some considerations relating to its application for gas turbines in ship drive. There is an important evaporative cooling potential throughout the world, when the dynamic data is evaluated, based on an analysis of coincident wet and dry bulb information. This data will allow ships’ gas turbine operators to make an assessment of the economics of evaporative fogging. The paper represents an introduction to the methodology and data analysis to derive the direct evaporative cooling potential to be used in marine gas turbine power output loss compensation.
- 1 January 2011
- Published by ASME International
- p. 901-906
Supporting Windpower Within a Separate Electric Power Grid
Utilization of windpower is considerably increasing in many countries around of the world. However, it produces an unreliable output due to the vagaries of the wind profile. To solve the problem, wind energy should be supported by local conventional sources. The requirements concerning the reliability and quality of electric energy supply can be most satisfactorily fulfilled when a windfarm is connected to a large electric power system. Then any electric power fluctuations, resulting either from wind turbulence or power demand variation, provoke system frequency variations. They should be damped by applying an appropriate control system of such a large power system. In this paper, the problem of control of a separate electric power system composed of windpower farm and supported by a gas turbine plant or a combined cycle has been investigated. First, the impact of wind turbulence on gas turbine plant control system has been modeled and simulated. This is carried out for different amplitudes and frequencies of wind speed. Next, the structure of gas turbine plant control system and its parameters have been adapted to limit the power and frequency fluctuations resulting from wind turbulence. Then the design is further developed by considering a combined cycle instead of a single gas turbine.
- 1 January 2011
- Published by ASME International
- p. 901-906
Supporting Windpower Within a Separate Electric Power Grid
Utilization of windpower is considerably increasing in many countries around of the world. However, it produces an unreliable output due to the vagaries of the wind profile. To solve the problem, wind energy should be supported by local conventional sources. The requirements concerning the reliability and quality of electric energy supply can be most satisfactorily fulfilled when a windfarm is connected to a large electric power system. Then any electric power fluctuations, resulting either from wind turbulence or power demand variation, provoke system frequency variations. They should be damped by applying an appropriate control system of such a large power system. In this paper, the problem of control of a separate electric power system composed of windpower farm and supported by a gas turbine plant or a combined cycle has been investigated. First, the impact of wind turbulence on gas turbine plant control system has been modeled and simulated. This is carried out for different amplitudes and frequencies of wind speed. Next, the structure of gas turbine plant control system and its parameters have been adapted to limit the power and frequency fluctuations resulting from wind turbulence. Then the design is further developed by considering a combined cycle instead of a single gas turbine.
- 1 January 2009
- Published by Walter de Gruyter GmbH in Polish Maritime Research
- Vol. 16 (Special)
Specificity of automatic control of micro-turbines (steam or gas -driven and expanders) in dispersed generation system of heat and electric power
- 1 January 2009
- Published by Walter de Gruyter GmbH in Polish Maritime Research
- Vol. 16 (Special)
Specificity of automatic control of micro-turbines (steam or gas -driven and expanders) in dispersed generation system of heat and electric power
- 1 January 2007
- Published by ASME International
- p. 1069-1072
Counteracting Windpower Fluctuations Within a Separate Electric Power Grid
Since 1990, global wind energy capacity has been doubling every three years, along with a corresponding fall in the cost of wind turbines, measured per kWe of output. The price of electricity from windpower is now close to the price of electricity produced from conventional sources. However, such farms produce unreliable output due to the vagaries of the region’s wind profile and so can not meet demand. Without action there could be major problems with fluctuating power quality. The first thing to consider with wind generation is how to achieve the optimum power output from the turbine in relation to balancing supply and demand. Such renewable energy sources as wind needs local support from conventional sources. Technological solutions do exist to counteract such problems. One of them, which has been discussed is a separate electrical power system composed of windpower farm and of gas turbine power plant. Any fluctuations of windpower have to be damped due to an appropriate action of gas turbine power plant. For this purpose a specific power and frequency control system is required that would provide limiting the power and frequency fluctuations resulting from wind turbulence.
- 1 January 2007
- Published by ASME International
- p. 1069-1072
Counteracting Windpower Fluctuations Within a Separate Electric Power Grid
Since 1990, global wind energy capacity has been doubling every three years, along with a corresponding fall in the cost of wind turbines, measured per kWe of output. The price of electricity from windpower is now close to the price of electricity produced from conventional sources. However, such farms produce unreliable output due to the vagaries of the region’s wind profile and so can not meet demand. Without action there could be major problems with fluctuating power quality. The first thing to consider with wind generation is how to achieve the optimum power output from the turbine in relation to balancing supply and demand. Such renewable energy sources as wind needs local support from conventional sources. Technological solutions do exist to counteract such problems. One of them, which has been discussed is a separate electrical power system composed of windpower farm and of gas turbine power plant. Any fluctuations of windpower have to be damped due to an appropriate action of gas turbine power plant. For this purpose a specific power and frequency control system is required that would provide limiting the power and frequency fluctuations resulting from wind turbulence.
- 1 January 2004
- Published by ASME International
- p. 65-70
An Impact of Environmental Disturbances on Combined Cycle Power Plant Control
Combined cycle power plants operate at thermal efficiency approaching 60 percent. In the same time their performance presents several problems that have to be addressed. E.g. gas turbines are very sensitive to backpressure exerted on them by the heat recovery steam generators as well as to ambient pressure and temperature.
- 1 January 2004
- Published by ASME International
- p. 65-70
An Impact of Environmental Disturbances on Combined Cycle Power Plant Control
Combined cycle power plants operate at thermal efficiency approaching 60 percent. In the same time their performance presents several problems that have to be addressed. E.g. gas turbines are very sensitive to backpressure exerted on them by the heat recovery steam generators as well as to ambient pressure and temperature.
- 4 June 2001
- Published by ASME International
Combined Cycle and Cogeneration Prospects in Former Centrally Planned Economies
An important restructuring of Polish electric power system is required. It should result in electric power capacity development, thermodynamic and economic efficiency increase, environment pollution reduction. These are two low investment ways of performing those goals: combined cycle and cogeneration. The problem is similar in most of former centrally planned economies (Central and Eastern Europe).
- 4 June 2001
- Published by ASME International
Combined Cycle and Cogeneration Prospects in Former Centrally Planned Economies
An important restructuring of Polish electric power system is required. It should result in electric power capacity development, thermodynamic and economic efficiency increase, environment pollution reduction. These are two low investment ways of performing those goals: combined cycle and cogeneration. The problem is similar in most of former centrally planned economies (Central and Eastern Europe).
- 8 May 2000
- Published by ASME International
Influence of Disturbances on Transients of a Gas Turbine Ship Propulsion System — Preliminary Investigations
A gas turbine ship propulsion control system transients have been investigated. On the basis of a mathematical model composed of blocks modelling a two-shaft gas turbine, a gear (mechanical or electric), and a coupling shaft, some preliminary simulations have been carried out. Ship propeller shaft angular velocity, fuel flow rate, and gas turbine combustion chamber outlet temperature response to the ship propeller shaft angular velocity set point, and fuel flow rate, changes have been analyzed. Influences of limiters in the controller action on analyzed transients have been compared.
- 8 May 2000
- Published by ASME International
Influence of Disturbances on Transients of a Gas Turbine Ship Propulsion System — Preliminary Investigations
A gas turbine ship propulsion control system transients have been investigated. On the basis of a mathematical model composed of blocks modelling a two-shaft gas turbine, a gear (mechanical or electric), and a coupling shaft, some preliminary simulations have been carried out. Ship propeller shaft angular velocity, fuel flow rate, and gas turbine combustion chamber outlet temperature response to the ship propeller shaft angular velocity set point, and fuel flow rate, changes have been analyzed. Influences of limiters in the controller action on analyzed transients have been compared.
- 1 July 1999
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 32 (2) , 8226-8230
Influence of Plant Control Loop on Ship Propulsion System Dynamics
- 1 July 1999
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 32 (2) , 8226-8230
Influence of Plant Control Loop on Ship Propulsion System Dynamics
- 1 January 1988
- Published by Springer Nature
- p. 298-300
Power System Frequency Control Characteristics as a Function of Nuclear Power Plant Participation
- 1 January 1988
- Published by Springer Nature
- p. 298-300
Power System Frequency Control Characteristics as a Function of Nuclear Power Plant Participation