Changqing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Changqing Li has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
Wei Zhang
Peking Union Medical College (China)
18 shared publicationsDianwen Zhu
Bioengineering, UC Merced, 5200 N Lake Rd, Merced, California, 95343, UNITED STATES
15 shared publicationsSimon R. Cherry
Department of Biomedical Engineering, University of California, Davis, California 95616, USA
10 shared publicationsMichael C. Lun
Department of Bioengineering, University of California, Merced, Merced, CA, USA
9 shared publications- Reheman Baikejiang
School of Engineering, University of California, Merced, 5200 North Lake Road, Merced, California, 95343, UNITED STATES
9 shared publications Ge Wang
Department of Biomedical Engineering, Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, USA
7 shared publications
Latest Publications
- 13 August 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (16) , 4689-4692
Oxygen sensing using time-domain X-ray luminescence
Oxygen tension is a critical physiological parameter in deep tissues; however, high-resolution and non-invasive measurement of oxygenation remains challenging. In this study, we developed a prototype for a lifetime measurement system based on a pulsed carbon nanotube X-ray source to evaluate X-ray-excited luminescence oxygen sensing. The X-ray irradiated a PDMS fiber containing the rapidly responding X-ray scintillator cerium-doped lutetium orthosilicate (LSO) and an oxygen sensing dye, (Pt(II) meso-Tetra(pentafluorophenyl)porphine (PtTFPP)), that is excited by the LSO X-ray luminescence and emits red fluorescence quenched by oxygen. At 0 kPa oxygen tension, the sensor showed a lifetime of approximately 62 μs, while at 21 kPa oxygen, the emission was strongly quenched with an estimated lifetime less than 1.33 μs. Covering the oxygen-sensing fiber with chicken breast tissue slices from 1.4 to 8.3 mm thick had minimal effect on measured luminescence lifetime in deoxygenated conditions (lifetime of 62.0 ± 6.1 μs). Control measurements using gadolinium oxysulfide doped with europium (GOS:Eu) powder also confirmed thickness-independent lifetime behavior. These results demonstrate that X-ray-excited lifetime measurement depends primarily on oxygen concentration and is independent of tissue thickness, supporting the feasibility of deep-tissue oxygen sensing and future time-domain X-ray luminescence computed tomography (XLCT) imaging for three-dimensional oxygenation mapping.
- 13 August 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (16) , 4689-4692
Oxygen sensing using time-domain X-ray luminescence
Oxygen tension is a critical physiological parameter in deep tissues; however, high-resolution and non-invasive measurement of oxygenation remains challenging. In this study, we developed a prototype for a lifetime measurement system based on a pulsed carbon nanotube X-ray source to evaluate X-ray-excited luminescence oxygen sensing. The X-ray irradiated a PDMS fiber containing the rapidly responding X-ray scintillator cerium-doped lutetium orthosilicate (LSO) and an oxygen sensing dye, (Pt(II) meso-Tetra(pentafluorophenyl)porphine (PtTFPP)), that is excited by the LSO X-ray luminescence and emits red fluorescence quenched by oxygen. At 0 kPa oxygen tension, the sensor showed a lifetime of approximately 62 μs, while at 21 kPa oxygen, the emission was strongly quenched with an estimated lifetime less than 1.33 μs. Covering the oxygen-sensing fiber with chicken breast tissue slices from 1.4 to 8.3 mm thick had minimal effect on measured luminescence lifetime in deoxygenated conditions (lifetime of 62.0 ± 6.1 μs). Control measurements using gadolinium oxysulfide doped with europium (GOS:Eu) powder also confirmed thickness-independent lifetime behavior. These results demonstrate that X-ray-excited lifetime measurement depends primarily on oxygen concentration and is independent of tissue thickness, supporting the feasibility of deep-tissue oxygen sensing and future time-domain X-ray luminescence computed tomography (XLCT) imaging for three-dimensional oxygenation mapping.
- Open Access
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 26093-26104
Weighted Sinogram Filtered Back Projection for Focused Beam-Based X-Ray Luminescence Computed Tomography
X-ray luminescence computed tomography (XLCT) is an attractive hybrid imaging modality in which high-energy X-ray photons excite particles that emit optical photons. XLCT has been developed for more than a decade; however, its applications have been limited by several factors, including the lack of user-friendly reconstruction algorithms. In this paper, we propose a novel and straightforward reconstruction approach for XLCT imaging based on filtered back projection with a weighted sinogram. We validated the proposed reconstruction algorithm using phantom experiments. For the four-target phantom, we achieved a Dice coefficient of 91.5% and a contrast-to-noise ratio (CNR) of 25.22. Compared with reconstruction without weighting factors, the weighted sinogram improved the Dice coefficient by 3.5% and the CNR by 13%. Furthermore, for phantoms with low particle concentrations of 0.1 and 0.01 mg/mL, the CNR was improved by 76.9%. For the phantom experiment with target concentrations of 10 mg/mL and 1.0 mg/mL, the ratio of the reconstructed target values was 7.29, indicating a quantitative accuracy of 72.9% for the proposed weighted sinogram based filtered back-projection method. Due to its simplicity and novelty, this reconstruction approach has the potential to broaden the practical applications of XLCT imaging.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 26093-26104
Open AccessWeighted Sinogram Filtered Back Projection for Focused Beam-Based X-Ray Luminescence Computed Tomography
X-ray luminescence computed tomography (XLCT) is an attractive hybrid imaging modality in which high-energy X-ray photons excite particles that emit optical photons. XLCT has been developed for more than a decade; however, its applications have been limited by several factors, including the lack of user-friendly reconstruction algorithms. In this paper, we propose a novel and straightforward reconstruction approach for XLCT imaging based on filtered back projection with a weighted sinogram. We validated the proposed reconstruction algorithm using phantom experiments. For the four-target phantom, we achieved a Dice coefficient of 91.5% and a contrast-to-noise ratio (CNR) of 25.22. Compared with reconstruction without weighting factors, the weighted sinogram improved the Dice coefficient by 3.5% and the CNR by 13%. Furthermore, for phantoms with low particle concentrations of 0.1 and 0.01 mg/mL, the CNR was improved by 76.9%. For the phantom experiment with target concentrations of 10 mg/mL and 1.0 mg/mL, the ratio of the reconstructed target values was 7.29, indicating a quantitative accuracy of 72.9% for the proposed weighted sinogram based filtered back-projection method. Due to its simplicity and novelty, this reconstruction approach has the potential to broaden the practical applications of XLCT imaging.
- Open Access
Effects of Detector Configuration on X-Ray Luminescence Computed Tomography Imaging
Background: X-ray luminescence computed tomography (XLCT) has emerged as a promising hybrid biomedical imaging modality for over a decade. However, the detector’s configuration has not been studied. Methods: We have built a benchtop XLCT imaging system and designed different detector holders to adjust the detector’s orientations and distances. Phantom experiments were performed to evaluate the performance of the detector’s configurations. We have also performed a Monte Carlo simulation to study the detectable photon numbers. Results: The photon detection efficiency is reduced by more than 10 times as the detector orientation is changed from 0 degrees to 45 degrees. The efficiency is not reduced as the detector is up to 10 mm away from the object. The efficiency is reduced by 33% when the distance is 30 mm. The numerical simulation indicates that a ring detector improves the collection efficiency by 11.3 times. Conclusions: The XLCT’s detector configuration plays a major role in the XLCT imaging system design. In the future, a ring detector will enhance the detection efficiency of XLCT imaging.
Open AccessEffects of Detector Configuration on X-Ray Luminescence Computed Tomography Imaging
Background: X-ray luminescence computed tomography (XLCT) has emerged as a promising hybrid biomedical imaging modality for over a decade. However, the detector’s configuration has not been studied. Methods: We have built a benchtop XLCT imaging system and designed different detector holders to adjust the detector’s orientations and distances. Phantom experiments were performed to evaluate the performance of the detector’s configurations. We have also performed a Monte Carlo simulation to study the detectable photon numbers. Results: The photon detection efficiency is reduced by more than 10 times as the detector orientation is changed from 0 degrees to 45 degrees. The efficiency is not reduced as the detector is up to 10 mm away from the object. The efficiency is reduced by 33% when the distance is 30 mm. The numerical simulation indicates that a ring detector improves the collection efficiency by 11.3 times. Conclusions: The XLCT’s detector configuration plays a major role in the XLCT imaging system design. In the future, a ring detector will enhance the detection efficiency of XLCT imaging.
- Open Access
Pencil Beam Based X-ray Luminescence Computed Tomography Imaging of Deep Targets Three-dimensionally and Quantitatively
X-ray luminescence computed tomography (XLCT), especially pencil beam based XLCT, has been emerged for more than 15 years because it can image deep targets in tissue with high spatial resolution and high measurement sensitivity. However, its application is limited by long scanning time and the tedious efforts of finite element mesh generation for model based reconstruction. Our previous study has addressed the imaging speed issue. In this study, we propose to reconstruct XLCT with weighted filtered back projection (wFBP) which makes it possible to perform XLCT imaging three dimensionally for complex objects at a high spatial resolution. We have also proposed measurements with multiple detectors to obtain quantitative XLCT images. To evaluate the proposed methods, we have performed numerical simulations and different sets of phantom experiments including phantom experiments with a control contrast target, different concentrations, and different target sizes. We have also successfully reconstructed deep targets with a diameter of approximately 0.15 mm. For the phantom experiments with targets of different concentrations, using a 4-channel XLCT system and the wFBP, we achieved the ratio of 3.8:1.79:1, closely resembling the ground truth ratio of 4:2:1. Lastly, we have, for the first time, reconstructed different 3D targets at high spatial resolution, successfully, including a printed M target, a triangular hollow bar, and a hot background cuboid with “UCM Li Lab” slots. Our results indicate that the proposed wFBP advances the promising XLCT technology and makes it ready for in vivo studies in the future.
Open AccessPencil Beam Based X-ray Luminescence Computed Tomography Imaging of Deep Targets Three-dimensionally and Quantitatively
X-ray luminescence computed tomography (XLCT), especially pencil beam based XLCT, has been emerged for more than 15 years because it can image deep targets in tissue with high spatial resolution and high measurement sensitivity. However, its application is limited by long scanning time and the tedious efforts of finite element mesh generation for model based reconstruction. Our previous study has addressed the imaging speed issue. In this study, we propose to reconstruct XLCT with weighted filtered back projection (wFBP) which makes it possible to perform XLCT imaging three dimensionally for complex objects at a high spatial resolution. We have also proposed measurements with multiple detectors to obtain quantitative XLCT images. To evaluate the proposed methods, we have performed numerical simulations and different sets of phantom experiments including phantom experiments with a control contrast target, different concentrations, and different target sizes. We have also successfully reconstructed deep targets with a diameter of approximately 0.15 mm. For the phantom experiments with targets of different concentrations, using a 4-channel XLCT system and the wFBP, we achieved the ratio of 3.8:1.79:1, closely resembling the ground truth ratio of 4:2:1. Lastly, we have, for the first time, reconstructed different 3D targets at high spatial resolution, successfully, including a printed M target, a triangular hollow bar, and a hot background cuboid with “UCM Li Lab” slots. Our results indicate that the proposed wFBP advances the promising XLCT technology and makes it ready for in vivo studies in the future.
- Open Access
Pure Nano Genesis: Pioneering Universal Aqueous Nanostrategies from Pure Molecules to Revolutionise Diverse Applications
In this paper, we propose a novel universal approach for the construction of stable and aqueous nanoparticles, Pure Nano systems, comprising solely small conjugated molecules without any excipients. Our experiments confirm that the generation of surface charges plays an essential role during the spontaneous aggregation of conjugated molecules in the process of Pure Nano system fabrication, as it governs growth and confers physiochemical stability to particles at the nano scale. This approach overcomes solubility challenges in highly hydrophobic conjugated molecules by obviating excipients and enabling up to 100% drug loading capacity. Confirmation of this capability stems from the successful preparation of approximately 100 Pure Nano systems, incorporating different combinations of 27 conjugated molecules distinguished by their diverse dissociation types and degrees. The proposed preparation method is robust, simple, fast, and reliable, making it well-suited for large-scale manufacturing due to its array of unique features. This strategy affords a singular, molecular-focused approach, showcasing the intrinsic bioactivity of its constituent molecules while enabling aqueous dispersion for diverse applications. And in vivo experiments confirm the exceptional efficacy of various Pure Nano systems in reinstating dextran sodium sulfate induced acute ulcerative colitis to a healthy state, restoring myocardial ischemia/reperfusion injury to normal levels, and effectively treating cancer in mice with significantly improved median survival rates. This innovative nano drug delivery system represents a groundbreaking advancement with the potential to revolutionise translational nanomedicine. Positioned at the forefront of therapeutic possibilities, it is anticipated to substantially improve the efficacy and safety of nano therapies. This advancement heralds a new era, offering a highly targeted and efficient approach in the treatment of diverse medical conditions.
Open AccessPure Nano Genesis: Pioneering Universal Aqueous Nanostrategies from Pure Molecules to Revolutionise Diverse Applications
In this paper, we propose a novel universal approach for the construction of stable and aqueous nanoparticles, Pure Nano systems, comprising solely small conjugated molecules without any excipients. Our experiments confirm that the generation of surface charges plays an essential role during the spontaneous aggregation of conjugated molecules in the process of Pure Nano system fabrication, as it governs growth and confers physiochemical stability to particles at the nano scale. This approach overcomes solubility challenges in highly hydrophobic conjugated molecules by obviating excipients and enabling up to 100% drug loading capacity. Confirmation of this capability stems from the successful preparation of approximately 100 Pure Nano systems, incorporating different combinations of 27 conjugated molecules distinguished by their diverse dissociation types and degrees. The proposed preparation method is robust, simple, fast, and reliable, making it well-suited for large-scale manufacturing due to its array of unique features. This strategy affords a singular, molecular-focused approach, showcasing the intrinsic bioactivity of its constituent molecules while enabling aqueous dispersion for diverse applications. And in vivo experiments confirm the exceptional efficacy of various Pure Nano systems in reinstating dextran sodium sulfate induced acute ulcerative colitis to a healthy state, restoring myocardial ischemia/reperfusion injury to normal levels, and effectively treating cancer in mice with significantly improved median survival rates. This innovative nano drug delivery system represents a groundbreaking advancement with the potential to revolutionise translational nanomedicine. Positioned at the forefront of therapeutic possibilities, it is anticipated to substantially improve the efficacy and safety of nano therapies. This advancement heralds a new era, offering a highly targeted and efficient approach in the treatment of diverse medical conditions.
- Open Access
- 23 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 134183-134190
Superfast Scan of Focused X-Ray Luminescence Computed Tomography Imaging
X-ray luminescence computed tomography (XLCT) is a hybrid molecular imaging modality having the high spatial resolution of x-ray imaging and high measurement sensitivity of optical imaging. Narrow x-ray beam based XLCT imaging has shown promise for high spatial resolution imaging of luminescent targets in deep tissues, but the slow acquisition speed limits its applications. In this work, we have introduced a superfast XLCT scan scheme based on the photon counter detector and a fly-scanning method. The new scan scheme is compared with three other scan methods. We have also designed and built a single-pixel x-ray detector to detect object boundaries automatically. With the detector, we can perform the parallel beam CT imaging with the XLCT imaging simultaneously. We have built the prototype XLCT imaging system to verify the proposed scan scheme. A phantom embedded with a set of four side-by-side cylindrical targets was scanned.With the proposed superfast scan scheme, we have achieved 43 seconds per transverse scan, which is 28.6 times faster than before with slightly better XLCT image quality. The superfast scan allows us to perform 3D pencil beam XLCT imaging in the future.
- 23 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 134183-134190
Open AccessSuperfast Scan of Focused X-Ray Luminescence Computed Tomography Imaging
X-ray luminescence computed tomography (XLCT) is a hybrid molecular imaging modality having the high spatial resolution of x-ray imaging and high measurement sensitivity of optical imaging. Narrow x-ray beam based XLCT imaging has shown promise for high spatial resolution imaging of luminescent targets in deep tissues, but the slow acquisition speed limits its applications. In this work, we have introduced a superfast XLCT scan scheme based on the photon counter detector and a fly-scanning method. The new scan scheme is compared with three other scan methods. We have also designed and built a single-pixel x-ray detector to detect object boundaries automatically. With the detector, we can perform the parallel beam CT imaging with the XLCT imaging simultaneously. We have built the prototype XLCT imaging system to verify the proposed scan scheme. A phantom embedded with a set of four side-by-side cylindrical targets was scanned.With the proposed superfast scan scheme, we have achieved 43 seconds per transverse scan, which is 28.6 times faster than before with slightly better XLCT image quality. The superfast scan allows us to perform 3D pencil beam XLCT imaging in the future.
- 10 November 2023
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 32 (1) , 87-103
Multiple energy X-ray imaging of metal oxide particles inside gingival tissues
BACKGROUND: Periodontal disease affects over 50% of the global population and is characterized by gingivitis as the initial sign. One dental health issue that may contribute to the development of periodontal disease is foreign body gingivitis (FBG), which can result from exposure to some kinds of foreign metal particles from dental products or food. OBJECTIVE: We design a novel, portable, affordable, multispectral X-ray and fluorescence optical microscopic imaging system dedicated to detecting and differentiating metal oxide particles in dental pathological tissues. A novel denoising algorithm is applied. We verify the feasibility and optimize the performance of the imaging system with numerical simulations. METHODS: The designed imaging system has a focused X-ray tube with tunable energy spectra and thin scintillator coupled with an optical microscope as detector. A simulated soft tissue phantom is embedded with 2-micron thick metal oxide discs as the imaged object. GATE software is used to optimize the systematic parameters such as energy bandwidth and X-ray photon number. We have also applied a novel denoising method, Noise2Sim with a two-layer UNet structure, to improve the simulated image quality. RESULTS: The use of an X-ray source operating with an energy bandwidth of 5 keV, X-ray photon number of 108, and an X-ray detector with a 0.5 micrometer pixel size in a 100 by 100-pixel array allowed for the detection of particles as small as 0.5 micrometer. With the Noise2Sim algorithm, the CNR has improved substantially. A typical example is that the Aluminum (Al) target’s CNR is improved from 6.78 to 9.72 for the case of 108 X-ray photons with the Chromium (Cr) source of 5 keV bandwidth. CONCLUSIONS: Different metal oxide particles were differentiated using Contrast-to-Noise ratio (CNR) by utilizing four different X-ray spectra.
- 10 November 2023
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 32 (1) , 87-103
Multiple energy X-ray imaging of metal oxide particles inside gingival tissues
BACKGROUND: Periodontal disease affects over 50% of the global population and is characterized by gingivitis as the initial sign. One dental health issue that may contribute to the development of periodontal disease is foreign body gingivitis (FBG), which can result from exposure to some kinds of foreign metal particles from dental products or food. OBJECTIVE: We design a novel, portable, affordable, multispectral X-ray and fluorescence optical microscopic imaging system dedicated to detecting and differentiating metal oxide particles in dental pathological tissues. A novel denoising algorithm is applied. We verify the feasibility and optimize the performance of the imaging system with numerical simulations. METHODS: The designed imaging system has a focused X-ray tube with tunable energy spectra and thin scintillator coupled with an optical microscope as detector. A simulated soft tissue phantom is embedded with 2-micron thick metal oxide discs as the imaged object. GATE software is used to optimize the systematic parameters such as energy bandwidth and X-ray photon number. We have also applied a novel denoising method, Noise2Sim with a two-layer UNet structure, to improve the simulated image quality. RESULTS: The use of an X-ray source operating with an energy bandwidth of 5 keV, X-ray photon number of 108, and an X-ray detector with a 0.5 micrometer pixel size in a 100 by 100-pixel array allowed for the detection of particles as small as 0.5 micrometer. With the Noise2Sim algorithm, the CNR has improved substantially. A typical example is that the Aluminum (Al) target’s CNR is improved from 6.78 to 9.72 for the case of 108 X-ray photons with the Chromium (Cr) source of 5 keV bandwidth. CONCLUSIONS: Different metal oxide particles were differentiated using Contrast-to-Noise ratio (CNR) by utilizing four different X-ray spectra.
- Open Access
- 1 July 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2528 (1) , 012014
Effect of different roughness on oil film formation in a diesel engine
After diesel fuel injection, when the spray droplets in the air hit the wall, an oil film may be formed on the wall, and the surface roughness is the key parameter. To analyze the influence of roughness on the formation of oil film, a combustion model of the engine cylinder is built in this paper. The main part of the model is the simulation of diesel injection, and a related fuel injection model is built. The influence of cylinder wall roughness on the oil film formation in the diesel engine cylinder is analyzed through a wall-droplet interaction model.
- 1 July 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2528 (1) , 012014
Open AccessEffect of different roughness on oil film formation in a diesel engine
After diesel fuel injection, when the spray droplets in the air hit the wall, an oil film may be formed on the wall, and the surface roughness is the key parameter. To analyze the influence of roughness on the formation of oil film, a combustion model of the engine cylinder is built in this paper. The main part of the model is the simulation of diesel injection, and a related fuel injection model is built. The influence of cylinder wall roughness on the oil film formation in the diesel engine cylinder is analyzed through a wall-droplet interaction model.
- 10 April 2023
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 12468, 16-102
Oxygenation imaging in deep tissue with x-ray luminescence computed tomography (XLCT)
Oxygenation concentration of tissue is an important factor in culturing stem cells and in studying the therapy response of cancer cells. The hypoxia bone marrow is the site to harbor cancer cells. Thus, direct high-resolution measurements of molecular O2 would provide powerful means of monitoring cultured stem cells and therapied cancer cells. We proposed an imaging approach to measure oxygenation concentration in deep tissues, based on the XLCT, with combined strengths of high chemical sensitivity and high spatial resolution. We have developed different biosensing films for oxygenation measurements and tested these films with X-ray luminescent experiments. We have also performed phantom experiments with multiple targets to validate the XLCT imaging system with measurements at two channels.
- 10 April 2023
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 12468, 16-102
Oxygenation imaging in deep tissue with x-ray luminescence computed tomography (XLCT)
Oxygenation concentration of tissue is an important factor in culturing stem cells and in studying the therapy response of cancer cells. The hypoxia bone marrow is the site to harbor cancer cells. Thus, direct high-resolution measurements of molecular O2 would provide powerful means of monitoring cultured stem cells and therapied cancer cells. We proposed an imaging approach to measure oxygenation concentration in deep tissues, based on the XLCT, with combined strengths of high chemical sensitivity and high spatial resolution. We have developed different biosensing films for oxygenation measurements and tested these films with X-ray luminescent experiments. We have also performed phantom experiments with multiple targets to validate the XLCT imaging system with measurements at two channels.
- Open Access
- 1 April 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2473 (1) , 012005
Effect of Different Droplet Impinging Models on Oil Film Formation of Diesel Engine’s Piston
After diesel fuel injection, when spray droplets in the air hit the wall, four types of impingement states will be formed: stick, rebound, spread, and splash. There are already many models describing the impingement of droplets on the wall. In order to analyze the impact of the droplet-wall model on the formation of oil film, this paper constructed a three-dimensional model of the diesel combustion in engine’s cylinder. The main part of the model was the simulation of the diesel fuel injection process, and different droplet collision models were used to calculate their influence on oil film formation of engine’s piston.
- 1 April 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2473 (1) , 012005
Open AccessEffect of Different Droplet Impinging Models on Oil Film Formation of Diesel Engine’s Piston
After diesel fuel injection, when spray droplets in the air hit the wall, four types of impingement states will be formed: stick, rebound, spread, and splash. There are already many models describing the impingement of droplets on the wall. In order to analyze the impact of the droplet-wall model on the formation of oil film, this paper constructed a three-dimensional model of the diesel combustion in engine’s cylinder. The main part of the model was the simulation of the diesel fuel injection process, and different droplet collision models were used to calculate their influence on oil film formation of engine’s piston.