RBReheman Baikejiang

Reheman Baikejiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Reheman Baikejiang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Changqing Li

    Department of Electrical Engineering, University of California, Merced, Merced, CA, USA

    9 shared publications
  • Dianwen Zhu

    Bioengineering, UC Merced, 5200 N Lake Rd, Merced, California, 95343, UNITED STATES

    4 shared publications
  • Wei Zhang

    Engineering, University of California, Merced, 5200 n. lake road, Merced, California, UNITED STATES

    4 shared publications
  • Yue Zhao

    University of California, Merced, School of Engineering, Merced, California, United States

    4 shared publications
  • Jinyi Qi

    Department of Biomedical Engineering, University of California, Davis, CA 95616, USA

    2 shared publications
  • Andrew M Hernandez

    Department of Radiology, University of California - Davis, Sacramento, California, UNITED STATES

    1 shared publication

Latest Publications

  • The reduction of 176 Lu background in Lu-based PET scanners using optimized classification

    by Qian Wang, Ekaterina Mikhaylova, Reheman Baikejiang, Simon R Cherry

    Positron emission tomography (PET) using scanners incorporating lutetium-based (Lu-based) scintillators are widely used in nuclear medicine. However their application in imaging very low (99%). It was subsequently tested by imaging point-like source, planar Derenzo and bar phantoms with the pair of TOF-PET detectors. An 89.4% image contrast enhancement for the Derenzo phantom at an activity concentration of 100 Bq mm −2 , and a 52.4% peak-to-valley ratio improvement across the area of bar phantom at a concentration of 25 Bq mm −2 , were observed on the reconstructed images with XGBoost classification applied. The proposed method could extend the usage of Lu-based PET scanners to very low activity detection and imaging and has the potential to be used in a variety of molecular imaging tasks to detect low-level signals.


  • Generative adversarial network based regularized image reconstruction for PET

    by Zhaoheng Xie, Reheman Baikejiang, Tiantian Li, Xuezhu Zhang, Kuang Gong, Mengxi Zhang, Wenyuan Qi, Evren Asma, Jinyi Qi

    Positron emission tomography (PET) is an ill-posed inverse problem and suffers high noise due to limited number of detected events. Prior information can be used to improve the quality of reconstructed PET images. Deep neural networks have also been applied to regularized image reconstruction. One method is to use a pretrained denoising neural network to represent the PET image and to perform a constrained maximum likelihood estimation. In this work, we propose to use a generative adversarial network (GAN) to further improve the network performance. We also modify the objective function to include a data-matching term on the network input. Experimental studies using computer-based Monte Carlo simulations and real patient datasets demonstrate that the proposed method leads to noticeable improvements over the kernel-based and U-net-based regularization methods in terms of lesion contrast recovery versus background noise trade-offs.


  • Non-convex Shannon entropy for photon-limited imaging

    by Omar DeGuchy, Lasith Adhikari, Marcia F. Roummel, Reheman Baikejiang

    Reconstructing high-dimensional sparse signals from low-dimensional low-count photon observations is a challenging nonlinear optimization problem. In this paper, we build upon previous work on minimizing the Poisson log-likelihood and incorporate recent work on the generalized nonconvex Shannon entropy function for promoting sparsity in solutions. We explore the effectiveness of the proposed approach using numerical experiments.

  • Kernel-based anatomically-aided diffuse optical tomography reconstruction

    by Reheman Baikejiang, Wei Zhang, Dianwen Zhu, Andrew M Hernandez, Shadi Aminololama Shakeri, Guobao Wang, Jinyi Qi, John M Boone, Changqing Li

    Image reconstruction in diffuse optical tomography (DOT) is a challenging task because its inverse problem is nonlinear, ill-posed and ill-conditioned. Anatomical guidance from imaging modalities with high spatial resolution can substantially improve the quality of reconstructed DOT images. In this paper, inspired by the kernel methods in machine learning, we proposed a kernel method to introduce anatomical guidance into the DOT image reconstruction. In this kernel method, the optical absorption coefficient at each finite element node is represented as a function of a set of features obtained from anatomical images such as computed tomography (CT) images. Compared with Laplacian approaches that include structural priors, the proposed method does not require image segmentation. The proposed kernel method is validated with numerical simulations of 3D DOT reconstruction using synthetic CT data. 5% Gaussian noise was added to both the numerical DOT measurements and the simulated CT image. The proposed method was also validated by an agar phantom experiment with the anatomical guidance from a cone beam CT scan. The effects of voxel size and number of nearest neighborhood size in the kernel method on the reconstructed DOT images were studied. The results indicate that the spatial resolution and the accuracy of the reconstructed DOT images have been improved substantially after applying the anatomical guidance with the proposed kernel method comparing to the case without guidance. Furthermore, we demonstrated that the kernel method was able to utilize clinical breast CT images as anatomical guidance without segmentation. In addition, we found that the proposed kernel method was robust to the false positive guidance in the anatomical image.


  • Open Access

    Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method

    by Reheman Baikejiang, Yue Zhao, Brett Z. Fite, Katherine W. Ferrara, Changqing Li

    Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well known that FMT image quality can be improved substantially by applying the structural guidance in the FMT reconstruction. An approach to introducing anatomical information into the FMT reconstruction is presented using the kernel method. In contrast to conventional methods that incorporate anatomical information with a Laplacian-type regularization matrix, the proposed method introduces the anatomical guidance into the projection model of FMT. The primary advantage of the proposed method is that it does not require segmentation of targets in the anatomical images. Numerical simulations and phantom experiments have been performed to demonstrate the proposed approach’s feasibility. Numerical simulation results indicate that the proposed kernel method can separate two FMT targets with an edge-to-edge distance of 1 mm and is robust to false-positive guidance and inhomogeneity in the anatomical image. For the phantom experiments with two FMT targets, the kernel method has reconstructed both targets successfully, which further validates the proposed kernel method.


  • Application of kernel method in fluorescence molecular tomography

    by Yue Zhao, Reheman Baikejiang, Changqing Li


  • Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study

    by Reheman Baikejiang, Wei Zhang, Changqing Li

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as hemoglobin, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer imaging. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at the wavelength of 650 nm and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements and width of measurement patch, have been investigated. Our results indicate that an air-cooling EMCCD camera is good enough for the transmission mode DOT imaging. We have also found that measurements at six angular projections are sufficient for DOT to reconstruct the optical targets with 2 and 4 times absorption contrast when the CT guidance is applied. Finally, we have described our future research plan on integration of a multispectral DOT imaging system into a breast CT scanner.


  • CT guided diffuse optical tomography for breast cancer imaging

    by Reheman Baikejiang, Wei Zhang, Dianwen Zhu, Changqing Li


  • 3D mouse shape reconstruction based on phase-shifting algorithm for fluorescence molecular tomography imaging system

    by Yue Zhao, Dianwen Zhu, Reheman Baikejiang, Changqing Li

    This work introduces a fast, low-cost, robust method based on fringe pattern and phase shifting to obtain three-dimensional (3D) mouse surface geometry for fluorescence molecular tomography (FMT) imaging. We used two pico projector/webcam pairs to project and capture fringe patterns from different views. We first calibrated the pico projectors and the webcams to obtain their system parameters. Each pico projector/webcam pair had its own coordinate system. We used a cylindrical calibration bar to calculate the transformation matrix between these two coordinate systems. After that, the pico projectors projected nine fringe patterns with a phase-shifting step of 2π/9 onto the surface of a mouse-shaped phantom. The deformed fringe patterns were captured by the corresponding webcam respectively, and then were used to construct two phase maps, which were further converted to two 3D surfaces composed of scattered points. The two 3D point clouds were further merged into one with the transformation matrix. The surface extraction process took less than 30 seconds. Finally, we applied the Digiwarp method to warp a standard Digimouse into the measured surface. The proposed method can reconstruct the surface of a mouse-sized object with an accuracy of 0.5 mm, which we believe is sufficient to obtain a finite element mesh for FMT imaging. We performed an FMT experiment using a mouse-shaped phantom with one embedded fluorescence capillary target. With the warped finite element mesh, we successfully reconstructed the target, which validated our surface extraction approach.