Swathi Vallabh Badakere
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Swathi Vallabh Badakere has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Sirisha Senthil
Glaucoma, LV Prasad Eye Institute, Hyderabad, Telangana, India
6 shared publications Nikhil S. Choudhari
VST Center for Glaucoma, L V Prasad Eye Institute, Hyderabad, India
5 shared publicationsHarsha L. Rao
Narayana Nethralaya, Bannerghatta Road, Bangalore, India
3 shared publications- Anil Kumar Mandal
Jasti V Ramanamma Children's Eye Care Centre, Child Sight Institute; VST Centre for Glaucoma Care
2 shared publications Chandra Sekhar Garudadri
VST Glaucoma Centre, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Hyderabad, India
2 shared publicationsChandrasekhar Garudadri
VST Center for Glaucoma, L V Prasad Eye Institute, Hyderabad, India
2 shared publications
Latest Publications
- 1 May 2021
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 4 (3) , 238-243
Agreement of Intraocular Pressure Measurement of Icare ic200 with Goldmann Applanation Tonometer in Adult Eyes with Normal Cornea
- 1 May 2021
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 4 (3) , 238-243
Agreement of Intraocular Pressure Measurement of Icare ic200 with Goldmann Applanation Tonometer in Adult Eyes with Normal Cornea
- 1 May 2021
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 4 (3) , 305-311
Outcomes of Primary Combined Trabeculotomy and Trabeculectomy in Early-Onset Glaucoma in Children with Congenital Aniridia
- 1 May 2021
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 4 (3) , 305-311
Outcomes of Primary Combined Trabeculotomy and Trabeculectomy in Early-Onset Glaucoma in Children with Congenital Aniridia
- 1 January 2021
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 4 (1) , 89-94
Agreement of Intraocular Pressure Measurement of Icare ic200 with Goldmann Applanation Tonometer in Adult Eyes with Normal Cornea
- 1 January 2021
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 4 (1) , 89-94
Agreement of Intraocular Pressure Measurement of Icare ic200 with Goldmann Applanation Tonometer in Adult Eyes with Normal Cornea
- 1 September 2019
- Published by Elsevier in Ophthalmology
- Vol. 126 (9) , 1330-1332
Comparison of Rebound Tonometry and Handheld Applanation Tonometry in Pediatric Glaucoma with Clear and Scarred Corneas
- 1 September 2019
- Published by Elsevier in Ophthalmology
- Vol. 126 (9) , 1330-1332
Comparison of Rebound Tonometry and Handheld Applanation Tonometry in Pediatric Glaucoma with Clear and Scarred Corneas
- Open Access
- 1 May 2018
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 7 (3) , 19
Is Ahmed Glaucoma Valve Consistent in Performance?
Purpose: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. Methods: Each newly opened AGV device was connected to a digital manometer and was primed with normal saline. The device was then placed in a saline bath and connected to an open manometer, a digital manometer, and an infusion pump. Saline was infused at a rate of 3 μL/min for 24 hours. Digital manometer readings were recorded at 4 Hz. Results: Data obtained from 9 devices are presented as medians (ranges). The priming pressure was 1130 (835, 1625) mm Hg. Pressure versus time curves showed two distinct phases; transient and steady phases. The transient phase peak pressure was 24 (13, 45) mm Hg. In the steady phase, opening and closing pressures were 13 (10, 17) and 7 (4, 9) mm Hg, respectively; the valve leaflets briefly opened every 73.9 (51, 76.6) minutes and the fluctuation of pressure (difference between opening and closing pressures) was 6 (3, 9) mm Hg. The Spearman correlation coefficient between priming and opening and priming and closing pressure was ρ = −0.13 (P = 0.72) and ρ = −0.36 (P = 0.33), respectively. Conclusions: The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV. Translational Relevance: These laboratory findings might, at least partly, explain the variability in the clinical outcome of the device.
- 1 May 2018
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 7 (3) , 19
Open AccessIs Ahmed Glaucoma Valve Consistent in Performance?
Purpose: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. Methods: Each newly opened AGV device was connected to a digital manometer and was primed with normal saline. The device was then placed in a saline bath and connected to an open manometer, a digital manometer, and an infusion pump. Saline was infused at a rate of 3 μL/min for 24 hours. Digital manometer readings were recorded at 4 Hz. Results: Data obtained from 9 devices are presented as medians (ranges). The priming pressure was 1130 (835, 1625) mm Hg. Pressure versus time curves showed two distinct phases; transient and steady phases. The transient phase peak pressure was 24 (13, 45) mm Hg. In the steady phase, opening and closing pressures were 13 (10, 17) and 7 (4, 9) mm Hg, respectively; the valve leaflets briefly opened every 73.9 (51, 76.6) minutes and the fluctuation of pressure (difference between opening and closing pressures) was 6 (3, 9) mm Hg. The Spearman correlation coefficient between priming and opening and priming and closing pressure was ρ = −0.13 (P = 0.72) and ρ = −0.36 (P = 0.33), respectively. Conclusions: The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV. Translational Relevance: These laboratory findings might, at least partly, explain the variability in the clinical outcome of the device.
- 1 February 2018
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (2) , 129-135
Comparison of Scleral Tono‐Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry
SIGNIFICANCE: Measuring the intraocular pressure (IOP) on the sclera can be an alternative to conventional corneal measurement in eyes with scarred corneas. However, these measurements have to be evaluated prior in normal eyes. Our study aimed to evaluate scleral IOP using Tono‐Pen and compared it with corneal Goldmann applanation measurements. PURPOSE: The aim of this study was to evaluate the ability of limbal and scleral Tono‐Pen IOP readings to predict central corneal Goldmann applanation tonometry (GAT) readings in eyes with normal corneas. METHODS: In a cross‐sectional study, 115 eyes of 115 patients attending a tertiary eye care center underwent GAT on the central cornea followed by Tono‐Pen readings at the central cornea, at the limbus, and at the sclera. Bland‐Altman plots were used to determine the agreement between different methods of IOP measurement. RESULTS: The median IOP (interquartile range) by GAT performed on the central cornea was 18 (16, 24) mmHg, and the IOP ranged from 10 to 54 mmHg. The median IOPs (interquartile range) by Tono‐Pen obtained at central cornea, limbus, and sclera were 16 (13, 23), 23 (17, 28), and 33 (27, 44) mmHg, respectively. The Pearson correlation coefficient and the 95% limits of agreement between GAT readings and Tono‐Pen readings at the central cornea were 0.9 ( P <. 001) and −4.9 to 8.74 mmHg, respectively. The correlation coefficient between GAT readings and Tono‐Pen readings at the limbus and GAT readings and Tono‐Pen readings at the sclera was 0.46 ( P <. 001) and 0.23 ( P =. 01), respectively. The 95% limits of agreement between these pairs of readings were −20.55 to 13.66 and −44.02 to 13.37 mmHg, respectively. CONCLUSIONS: This study showed limited ability of Tono‐Pen readings obtained at the limbus and sclera to predict the central corneal GAT IOP readings in eyes with normal corneas at various IOP ranges.
- 1 February 2018
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (2) , 129-135
Comparison of Scleral Tono‐Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry
SIGNIFICANCE: Measuring the intraocular pressure (IOP) on the sclera can be an alternative to conventional corneal measurement in eyes with scarred corneas. However, these measurements have to be evaluated prior in normal eyes. Our study aimed to evaluate scleral IOP using Tono‐Pen and compared it with corneal Goldmann applanation measurements. PURPOSE: The aim of this study was to evaluate the ability of limbal and scleral Tono‐Pen IOP readings to predict central corneal Goldmann applanation tonometry (GAT) readings in eyes with normal corneas. METHODS: In a cross‐sectional study, 115 eyes of 115 patients attending a tertiary eye care center underwent GAT on the central cornea followed by Tono‐Pen readings at the central cornea, at the limbus, and at the sclera. Bland‐Altman plots were used to determine the agreement between different methods of IOP measurement. RESULTS: The median IOP (interquartile range) by GAT performed on the central cornea was 18 (16, 24) mmHg, and the IOP ranged from 10 to 54 mmHg. The median IOPs (interquartile range) by Tono‐Pen obtained at central cornea, limbus, and sclera were 16 (13, 23), 23 (17, 28), and 33 (27, 44) mmHg, respectively. The Pearson correlation coefficient and the 95% limits of agreement between GAT readings and Tono‐Pen readings at the central cornea were 0.9 ( P <. 001) and −4.9 to 8.74 mmHg, respectively. The correlation coefficient between GAT readings and Tono‐Pen readings at the limbus and GAT readings and Tono‐Pen readings at the sclera was 0.46 ( P <. 001) and 0.23 ( P =. 01), respectively. The 95% limits of agreement between these pairs of readings were −20.55 to 13.66 and −44.02 to 13.37 mmHg, respectively. CONCLUSIONS: This study showed limited ability of Tono‐Pen readings obtained at the limbus and sclera to predict the central corneal GAT IOP readings in eyes with normal corneas at various IOP ranges.
- 1 March 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (2) , 195-197
Glaucoma following phakic posterior chamber intraocular lens implantation
- 1 March 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (2) , 195-197
Glaucoma following phakic posterior chamber intraocular lens implantation
- 19 January 2016
- Published by BMJ in BMJ Case Reports
- Vol. 2016
Uveitis-glaucoma-hyphaema syndrome with in-the-bag placement of intraocular lens
Uveitis-glaucoma-hyphaema (UGH) syndrome is commonly reported following intraocular lens (IOL) implantation in the anterior chamber or malpositioned posterior chamber IOLs. It is extremely rare to have this complication in an eye with intact posterior capsule and a well placed in-the-bag IOL. We report a case of a 48-year-old man who presented with blurred vision after an uneventful cataract surgery in the right eye, and who was treated for anterior uveitis. The anterior chamber inflammation persisted despite intense treatment with topical steroids for 2 months, and the intraocular pressure was high. The posterior chamber IOL was in the bag and well covered by a capsulorrhexis margin. Dilated gonioscopy revealed inferior capsular bag hyphaema secondary to the superior haptic displacement due to a tear in the equatorial bag. Our case highlights the importance of dilated gonioscopy and a rare possibility of UGH syndrome in an eye with a well-placed IOL.
- 19 January 2016
- Published by BMJ in BMJ Case Reports
- Vol. 2016
Uveitis-glaucoma-hyphaema syndrome with in-the-bag placement of intraocular lens
Uveitis-glaucoma-hyphaema (UGH) syndrome is commonly reported following intraocular lens (IOL) implantation in the anterior chamber or malpositioned posterior chamber IOLs. It is extremely rare to have this complication in an eye with intact posterior capsule and a well placed in-the-bag IOL. We report a case of a 48-year-old man who presented with blurred vision after an uneventful cataract surgery in the right eye, and who was treated for anterior uveitis. The anterior chamber inflammation persisted despite intense treatment with topical steroids for 2 months, and the intraocular pressure was high. The posterior chamber IOL was in the bag and well covered by a capsulorrhexis margin. Dilated gonioscopy revealed inferior capsular bag hyphaema secondary to the superior haptic displacement due to a tear in the equatorial bag. Our case highlights the importance of dilated gonioscopy and a rare possibility of UGH syndrome in an eye with a well-placed IOL.
- 1 May 2013
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 29 (3) , 237
Re
- 1 May 2013
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 29 (3) , 237
Re