Sachin Tom John
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sachin Tom John has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Anirban Mukherjee
Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, West Bengal, India
2 shared publications - Manish Goyal
Department of Physiology, All India Institute of Medical Sciences, Bhubaneswar, India
1 shared publication - Priya Ranjan Muduli
Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, India
1 shared publication - Sweta Singh
Obstetrics and Gynecology, All India Institute of Medical Sciences, Bhubaneswar, Bhubaneswar, IND
1 shared publication
Latest Publications
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 101, 1-4
Ambulatory fetal heart monitoring with QRS detection employing independent component analysis
This paper covers the development of a fetal heart monitor (fHM) on an ARM Cortex-M3 based platform, and its application in extracting fetal heart rate (fHR) non-invasively from the maternal abdomen. The fHM is a low-power, inexpensive ambulatory device connected to smart-phones via Bluetooth. This monitor uses active-electrodes for primary signal-conditioning, and has a digital back end for running compute-intensive signal processing algorithms. The output, can be displayed on a smart-phone, can generate audible alarms during critical conditions or can be stored on-board for further processing. The fHM implements multiple algorithms to monitor the fetal heart rate. First, a tumbling-window based implementation of Independent Component Analysis (ICA) is employed on abdominal signals in order to simultaneously extract fetal and maternal cardiac components. Thereafter, the Pan-Tompkins algorithm (PTA) is used to detect QRS complexes. Preliminary tests show that this combination of algorithms can be employed to successfully estimate fetal and maternal heart rates, and has a low rate of spurious detections.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 101, 1-4
Ambulatory fetal heart monitoring with QRS detection employing independent component analysis
This paper covers the development of a fetal heart monitor (fHM) on an ARM Cortex-M3 based platform, and its application in extracting fetal heart rate (fHR) non-invasively from the maternal abdomen. The fHM is a low-power, inexpensive ambulatory device connected to smart-phones via Bluetooth. This monitor uses active-electrodes for primary signal-conditioning, and has a digital back end for running compute-intensive signal processing algorithms. The output, can be displayed on a smart-phone, can generate audible alarms during critical conditions or can be stored on-board for further processing. The fHM implements multiple algorithms to monitor the fetal heart rate. First, a tumbling-window based implementation of Independent Component Analysis (ICA) is employed on abdominal signals in order to simultaneously extract fetal and maternal cardiac components. Thereafter, the Pan-Tompkins algorithm (PTA) is used to detect QRS complexes. Preliminary tests show that this combination of algorithms can be employed to successfully estimate fetal and maternal heart rates, and has a low rate of spurious detections.
- 9 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 212-217
An Analog-Front-End for non-invasive fetal electrocardiography monitoring
Fetal electrocardiography (fECG) based assessment techniques are likely to be more effective in ensuring fetal well-being, than currently popular methods based on ultrasound echocardiography and pulse oximetry. Employing Non-invasive procedures for measurement of fECG not only ensures minimal patient discomfort, but also makes the product suitable for wearable applications. However, non-invasive fECG extraction has proven to be difficult due to low amplitudes of fECG signals, attenuation by maternal biological tissues, overlapping spectra with other fetal and maternal bio-signals and low-frequency noise in measurement devices. This paper describes the design of a noise optimized Analog-Front-End (AFE) for a non-invasive fECG monitor. The design criterion laid down for the fECG monitor require it to be an ambulatory, low-power, inexpensive device, interfaced to a smart-phone and capable of running computationally intensive signal processing algorithms. The primary role of the AFE is to filter-out large DC offsets, movement artifacts, high-frequency noise and subsequently amplify and condition the extracted signals before digitization. This noise optimized design makes use of active-electrodes fabricated on small printed circuit boards (PCB). Each PCB is mounted on standard Ag-AgCl electrodes to buffer, filter and amplify abdominal bio-signals as soon as they are detected. The extracted signals are then sent to the fECG monitor PCB for further processing and signal conditioning, before being digitized by a 24-bit analog-to-digital converter (ADC) of an ARM Cortex M3 based system-on-chip (SoC). The monitor is designed to work with supply voltages from 3.6Vdc to 5.5Vdc, allowing it to be powered from a variety of sources; battery packs to USB connectors. Working of the AFE was tested using synthetic signals and elementary biological signals.
- 9 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 212-217
An Analog-Front-End for non-invasive fetal electrocardiography monitoring
Fetal electrocardiography (fECG) based assessment techniques are likely to be more effective in ensuring fetal well-being, than currently popular methods based on ultrasound echocardiography and pulse oximetry. Employing Non-invasive procedures for measurement of fECG not only ensures minimal patient discomfort, but also makes the product suitable for wearable applications. However, non-invasive fECG extraction has proven to be difficult due to low amplitudes of fECG signals, attenuation by maternal biological tissues, overlapping spectra with other fetal and maternal bio-signals and low-frequency noise in measurement devices. This paper describes the design of a noise optimized Analog-Front-End (AFE) for a non-invasive fECG monitor. The design criterion laid down for the fECG monitor require it to be an ambulatory, low-power, inexpensive device, interfaced to a smart-phone and capable of running computationally intensive signal processing algorithms. The primary role of the AFE is to filter-out large DC offsets, movement artifacts, high-frequency noise and subsequently amplify and condition the extracted signals before digitization. This noise optimized design makes use of active-electrodes fabricated on small printed circuit boards (PCB). Each PCB is mounted on standard Ag-AgCl electrodes to buffer, filter and amplify abdominal bio-signals as soon as they are detected. The extracted signals are then sent to the fECG monitor PCB for further processing and signal conditioning, before being digitized by a 24-bit analog-to-digital converter (ADC) of an ARM Cortex M3 based system-on-chip (SoC). The monitor is designed to work with supply voltages from 3.6Vdc to 5.5Vdc, allowing it to be powered from a variety of sources; battery packs to USB connectors. Working of the AFE was tested using synthetic signals and elementary biological signals.