Joo Hyun Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joo Hyun Moon has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
B. M. Kim
1 shared publicationHee Don Seo
1 shared publicationJae Wook Kim
Dongguk University, Gyeongju Campus, 123 Dongdae-ro, Gyeongbuk 38066, Republic of Korea
1 shared publicationKyu-Tae Kim
1 shared publication- Min Soo Kim
Korean Society of Breast Implant Research, Seoul, Republic of Korea
1 shared publication Rinah Kim
Dongguk University, Gyeongju Campus, 123 Dongdae-ro, Gyeongbuk 38066, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 18 October 2017
- Published by Wiley in Journal of Sensors
- Vol. 2017, 1-5
Development and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes
A fiber-optic radiation sensor (FORS) was developed for remote and real-time measurements of beta radiation from radioactive-contaminated soil. The sensing probe consisted of a bundle of organic scintillators and a mixture of epoxy resin to improve the detection efficiency. The measurement system consisted of a sensing probe with an aluminium foil reflector, a transmitting plastic optical fiber, and a light-measuring system comprising a photomultiplier tube, a preamplifier, a multichannel analyzer, and a laptop computer. Several sensing probes, whose dead-end diameters were 26 mm (bundle type I), 36 mm (bundle type II), and 46 mm (bundle type III), were prepared and characterized to identify the best sensing probe in terms of its radiation detection efficiency. The reproducibility of the FORS for the measurement of beta radiation was confirmed using a -test. The measurements showed that the FORS sensing probe with a diameter 46 mm has the best detection performance.- 18 October 2017
- Published by Wiley in Journal of Sensors
- Vol. 2017, 1-5
Open AccessDevelopment and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes
A fiber-optic radiation sensor (FORS) was developed for remote and real-time measurements of beta radiation from radioactive-contaminated soil. The sensing probe consisted of a bundle of organic scintillators and a mixture of epoxy resin to improve the detection efficiency. The measurement system consisted of a sensing probe with an aluminium foil reflector, a transmitting plastic optical fiber, and a light-measuring system comprising a photomultiplier tube, a preamplifier, a multichannel analyzer, and a laptop computer. Several sensing probes, whose dead-end diameters were 26 mm (bundle type I), 36 mm (bundle type II), and 46 mm (bundle type III), were prepared and characterized to identify the best sensing probe in terms of its radiation detection efficiency. The reproducibility of the FORS for the measurement of beta radiation was confirmed using a -test. The measurements showed that the FORS sensing probe with a diameter 46 mm has the best detection performance. - 1 February 2011
- Published by American Scientific Publishers in Sensor Letters
- Vol. 9 (1) , 218-222
Measurement System Design of Low Skin Resistance Using Novel Planar Small Electrode Sensors
A Novel Planar Small Electrode Sensor (NPSES) using the semi-conductor process was developed in this study to find out Acupuncture Points (APs) or Biological Active Points (BAP) on the human being's skin. The NPSES with eight (8) electrodes tracks generates the electrical properties of the BAPs on the skin. These eight tracks are located in a circle of 2 mm diameter. The BAP locations generated by the NPSES are characterized by high electric potential, high electric capacity, and low electric resistance, compared to non-Acupuncture Points (non-APs). The traditional unit applied for the BAP is the cun, the Chinese anatomical inch. The BAPs are distinguished by the difference in voltage between the measurement electrode and the reference one, i.e., the difference in the resistance and reactance of BAPs. The BAP size might be in the range of 1 to 2 mm2. Five (5) healthy human subjects of between 27 and 42 years were examined to investigate the effectiveness of the NPSES for finding out the BAPs. The current and frequency applied to this experiment were in the range of 7.5 μA and 0.1 Hz to 1.5 kHz, respectively. We believe that the NPSES system developed in this study is highly reliable for and scientifically applicable to locating the BAPs on the human being's skin.
- 1 February 2011
- Published by American Scientific Publishers in Sensor Letters
- Vol. 9 (1) , 218-222
Measurement System Design of Low Skin Resistance Using Novel Planar Small Electrode Sensors
A Novel Planar Small Electrode Sensor (NPSES) using the semi-conductor process was developed in this study to find out Acupuncture Points (APs) or Biological Active Points (BAP) on the human being's skin. The NPSES with eight (8) electrodes tracks generates the electrical properties of the BAPs on the skin. These eight tracks are located in a circle of 2 mm diameter. The BAP locations generated by the NPSES are characterized by high electric potential, high electric capacity, and low electric resistance, compared to non-Acupuncture Points (non-APs). The traditional unit applied for the BAP is the cun, the Chinese anatomical inch. The BAPs are distinguished by the difference in voltage between the measurement electrode and the reference one, i.e., the difference in the resistance and reactance of BAPs. The BAP size might be in the range of 1 to 2 mm2. Five (5) healthy human subjects of between 27 and 42 years were examined to investigate the effectiveness of the NPSES for finding out the BAPs. The current and frequency applied to this experiment were in the range of 7.5 μA and 0.1 Hz to 1.5 kHz, respectively. We believe that the NPSES system developed in this study is highly reliable for and scientifically applicable to locating the BAPs on the human being's skin.