Development and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes
Authors:
Open Access
- 18 October 2017
- journal article
- research article
- Published by Wiley in Journal of Sensors
- Vol. 2017, 1-5
Abstract
A fiber-optic radiation sensor (FORS) was developed for remote and real-time measurements of beta radiation from radioactive-contaminated soil. The sensing probe consisted of a bundle of organic scintillators and a mixture of epoxy resin to improve the detection efficiency. The measurement system consisted of a sensing probe with an aluminium foil reflector, a transmitting plastic optical fiber, and a light-measuring system comprising a photomultiplier tube, a preamplifier, a multichannel analyzer, and a laptop computer. Several sensing probes, whose dead-end diameters were 26 mm (bundle type I), 36 mm (bundle type II), and 46 mm (bundle type III), were prepared and characterized to identify the best sensing probe in terms of its radiation detection efficiency. The reproducibility of the FORS for the measurement of beta radiation was confirmed using a -test. The measurements showed that the FORS sensing probe with a diameter 46 mm has the best detection performance.
Keywords
Funding Information
- Ministry of Science, ICT and Future Planning (2012M2B2B1055499)
This publication has 9 references indexed in Scilit:
- Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor2016
- Radioactivity measurement of radioactive contaminated soil by using a fiber-optic radiation sensorJournal of the Korean Physical Society, 2016
- Strontium-90 activity concentration in soil samples from the exclusion zone of the Fukushima daiichi nuclear power plantScientific Reports, 2016
- Feasibility Study on Development of a Fiber-Optic Dual Detector to Measure Beta- and Gamma-rays SimultaneouslyThe Transactions of The Korean Institute of Electrical Engineers, 2014
- Development and characterization of the integrated fiber-optic sensor for remote detection of alpha radiationJournal of the Korean Physical Society, 2013
- Comparison of BCF-10, BCF-12, and BCF-20 Scintillating Fibers for Use in a 1-Dimensional Linear SensorIEEE Transactions on Nuclear Science, 2013
- Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray SpectroscopyJournal of Sensor Science and Technology, 2012
- Fabrication and Characterization of a Fiber-optic Radiation Sensor for Detection of TritiumKorean Journal of Optics and Photonics, 2009