Takaaki Nara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takaaki Nara has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Shigeru Ando
9 shared publicationsTakeshi Mizuno
Department of Mechanical Engineering, Saitama University, Shimo-Okubo 255, Saitama, 338-8570, JAPAN
5 shared publications- Yuji Gotoh
Oita University
5 shared publications - Kanta Shiku
Graduate School of Information Science and Technology, The University of Tokyo, Bunkyo-ku, Japan
4 shared publications - Keisuke Hasegawa
Department of Mechanical Science, Graduate School of Science and Engineering, Saitama University
4 shared publications - Akihiro Chiba
NTT Corp, Tokyo, Japan
3 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 6 (6)
Localization system for urban search and rescue using smartphone microphones
Methods for rescuing survivors buried under rubble generated in earthquakes are urgently needed. In this study, we propose a method for searching for victims' smartphones using audible sound. A searcher generates dipole sound fields using four loudspeakers, which are measured by the victim's smartphone. Then, the azimuth of the smartphone in the searcher's coordinates is computed and transmitted to the searcher. The proposed method was validated via experiments conducted in a training field for earthquake disasters. The results revealed that the searcher can approach the smartphone by repeatedly estimating its direction and moving the sound source toward it.
- 1 June 2026
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 6 (6)
Open AccessLocalization system for urban search and rescue using smartphone microphones
Methods for rescuing survivors buried under rubble generated in earthquakes are urgently needed. In this study, we propose a method for searching for victims' smartphones using audible sound. A searcher generates dipole sound fields using four loudspeakers, which are measured by the victim's smartphone. Then, the azimuth of the smartphone in the searcher's coordinates is computed and transmitted to the searcher. The proposed method was validated via experiments conducted in a training field for earthquake disasters. The results revealed that the searcher can approach the smartphone by repeatedly estimating its direction and moving the sound source toward it.
- Open Access
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Noise-robust method using sparsity for locating a crack in a steel rod based on the Fourier coefficients of the leakage magnetic flux
In the leakage magnetic flux (LMF) method for non-destructive inspection, locating a tiny crack with a depth of less than 100 µm is a challenge due to the low signal-to-noise ratio. This paper presents a noise-robust method for locating a tiny surface crack in a moving steel rod. For the time series data obtained with our two previously proposed sensors, which measure the circumferential Fourier cosine and sine coefficients of the LMF, we introduce a method that solves a linear inverse problem with sparsity regularization, enabling localization of a crack with a depth of 70 µm.
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Open AccessNoise-robust method using sparsity for locating a crack in a steel rod based on the Fourier coefficients of the leakage magnetic flux
In the leakage magnetic flux (LMF) method for non-destructive inspection, locating a tiny crack with a depth of less than 100 µm is a challenge due to the low signal-to-noise ratio. This paper presents a noise-robust method for locating a tiny surface crack in a moving steel rod. For the time series data obtained with our two previously proposed sensors, which measure the circumferential Fourier cosine and sine coefficients of the LMF, we introduce a method that solves a linear inverse problem with sparsity regularization, enabling localization of a crack with a depth of 70 µm.
- 1 December 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (6) , 4816-4824
Visualization of sound source positions using pinpoint nonlinear secondary emission by ultrasound focus scanning
This study proposes a method for visualizing sound fields utilizing midair nonlinear acoustic phenomena in a spatially localized manner. Conventional microphone-array-based sound field visualization method requires multi-channel synchronous signal processing that handles phase information of the observed waveforms, which inevitably hinders production of cost-effective recording devices. Additionally, the inserted microphones themselves can disturb the measured sound field, and artifacts owing to the spacing between microphones may arise. To address these issues, the study introduces a measurement method that involves scanning a focal point of converging ultrasonic beams in the target sound field. The ultrasonic focus generates secondary parametric waves via frequency modulation of the target sound field only near the focal point due to the acoustic nonlinear effect. The visualization of the target field is completed by demodulating these waves measured with a single immobilized microphone located outside the field. This technique achieves spatial selectivity of recording via steering of the ultrasonic focus serving as a parametric probe, allowing the target sound field information to be reconstructed from a monaural recorded signal. This approach of sound field visualization ranging over hundreds of millimeters is based on a single-channel recording, where no recording elements densely arranged in the target sound field are required.
- 1 December 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (6) , 4816-4824
Visualization of sound source positions using pinpoint nonlinear secondary emission by ultrasound focus scanning
This study proposes a method for visualizing sound fields utilizing midair nonlinear acoustic phenomena in a spatially localized manner. Conventional microphone-array-based sound field visualization method requires multi-channel synchronous signal processing that handles phase information of the observed waveforms, which inevitably hinders production of cost-effective recording devices. Additionally, the inserted microphones themselves can disturb the measured sound field, and artifacts owing to the spacing between microphones may arise. To address these issues, the study introduces a measurement method that involves scanning a focal point of converging ultrasonic beams in the target sound field. The ultrasonic focus generates secondary parametric waves via frequency modulation of the target sound field only near the focal point due to the acoustic nonlinear effect. The visualization of the target field is completed by demodulating these waves measured with a single immobilized microphone located outside the field. This technique achieves spatial selectivity of recording via steering of the ultrasonic focus serving as a parametric probe, allowing the target sound field information to be reconstructed from a monaural recorded signal. This approach of sound field visualization ranging over hundreds of millimeters is based on a single-channel recording, where no recording elements densely arranged in the target sound field are required.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (9) , 1-6
Localization of Multiple Cracks in a Cylindrical Ferromagnetic Rod Based on the Fourier Coefficients of the Radial Leakage Magnetic Flux
This article presents a novel method of magnetic flux leakage testing (MFLT) to estimate the circumferential positions of multiple cracks in a cylindrical ferromagnetic rod by measuring the circumferential multiple-order Fourier coefficients of the radial leakage magnetic flux (LMF). By modeling the cracks as magnetic dipoles, the positions and intensities were estimated by solving the algebraic equations involving the Fourier coefficients. Sensors were developed and used to directly measure the zeroth-, first-, and second-order Fourier cosine and sine coefficients of the radial LMF. The circumferential and axial positions of one or two hole-shaped cracks in an S45C cylindrical rod were estimated using the proposed method.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (9) , 1-6
Localization of Multiple Cracks in a Cylindrical Ferromagnetic Rod Based on the Fourier Coefficients of the Radial Leakage Magnetic Flux
This article presents a novel method of magnetic flux leakage testing (MFLT) to estimate the circumferential positions of multiple cracks in a cylindrical ferromagnetic rod by measuring the circumferential multiple-order Fourier coefficients of the radial leakage magnetic flux (LMF). By modeling the cracks as magnetic dipoles, the positions and intensities were estimated by solving the algebraic equations involving the Fourier coefficients. Sensors were developed and used to directly measure the zeroth-, first-, and second-order Fourier cosine and sine coefficients of the radial LMF. The circumferential and axial positions of one or two hole-shaped cracks in an S45C cylindrical rod were estimated using the proposed method.
- 26 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (12) , 1-4
Detection and Location Estimate of External Surface Defects Using Velocity Effects From Double-Sided Quadrupole Permanent Magnets
The round bar steel made of C45 steel material is widely used as a general machine part material, such as springs for automobiles. This round steel bar requires high-speed surface defect inspection during the manufacturing process. In this research, an inspection method is proposed in which a round steel bar is moved at a high speed of 1m/s in a ring-shaped permanent magnet with a single differential detection coil to detect surface defect in the round steel bar. In addition, the possibility of estimating the location of a circumferential defect on the round steel bar is demonstrated by using two double-sided quadrupole permanent magnets with only one differential detection coil.
- 26 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (12) , 1-4
Detection and Location Estimate of External Surface Defects Using Velocity Effects From Double-Sided Quadrupole Permanent Magnets
The round bar steel made of C45 steel material is widely used as a general machine part material, such as springs for automobiles. This round steel bar requires high-speed surface defect inspection during the manufacturing process. In this research, an inspection method is proposed in which a round steel bar is moved at a high speed of 1m/s in a ring-shaped permanent magnet with a single differential detection coil to detect surface defect in the round steel bar. In addition, the possibility of estimating the location of a circumferential defect on the round steel bar is demonstrated by using two double-sided quadrupole permanent magnets with only one differential detection coil.
- Open Access
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (9) , 1-5
Localization of a Crack in Moving Cylindrical Ferromagnetic Rods by Measuring the Fourier Coefficients of the Leakage Magnetic Flux
This article presents a novel leakage magnetic flux (LMF) method to estimate crack positions in moving cylindrical ferromagnetic rods. The crack positions are estimated by the circumferential first-order Fourier coefficients of the LMF by utilizing the dc excitation and modeling the moving crack as a magnetic dipole. The Fourier coefficients are directly measured by using only two coils. In addition, numerical experiments were conducted to evaluate the effect of motion-induced eddy current (MIEC). The demonstration of locating hole-shaped cracks in moving S45C cylindrical rods was performed by using the proposed method.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (9) , 1-5
Open AccessLocalization of a Crack in Moving Cylindrical Ferromagnetic Rods by Measuring the Fourier Coefficients of the Leakage Magnetic Flux
This article presents a novel leakage magnetic flux (LMF) method to estimate crack positions in moving cylindrical ferromagnetic rods. The crack positions are estimated by the circumferential first-order Fourier coefficients of the LMF by utilizing the dc excitation and modeling the moving crack as a magnetic dipole. The Fourier coefficients are directly measured by using only two coils. In addition, numerical experiments were conducted to evaluate the effect of motion-induced eddy current (MIEC). The demonstration of locating hole-shaped cracks in moving S45C cylindrical rods was performed by using the proposed method.
- Open Access
- 5 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (4) , 045012
Magnetic resonance imaging of blood perfusion rate based on Helmholtz decomposition of heat flux
Objective. Thermal property (TP) maps of human tissues are useful for tumor treatment and diagnosis. In particular, the blood perfusion rate is significantly different for tumors and healthy tissues. Noninvasive techniques that reconstruct TPs from the temperature measured via magnetic resonance imaging (MRI) by solving an inverse bioheat transfer problem have been developed. A few conventional methods can reconstruct spatially varying TP distributions, but they have several limitations. First, most methods require the numerical Laplacian computation of the temperature, and hence they are sensitive to noise. In addition, some methods require the division of a region of interest (ROI) into sub-regions with homogeneous TPs using prior anatomical information, and they assume an unmeasurable initial temperature distribution. We propose a novel robust reconstruction method without the division of an ROI or the assumption of an initial temperature distribution. Approach. The proposed method estimates blood perfusion rate maps from relative temperature changes. This method avoids the computation of the Laplacian by using integral representations of the Helmholtz decomposition of the heat flux. Main Result. We compare the reconstruction results of the conventional and proposed methods using numerical simulations. The results indicate the robustness of the proposed method. Significance. This study suggests the feasibility of thermal property mapping with MRI using the robust proposed method.
- 5 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (4) , 045012
Open AccessMagnetic resonance imaging of blood perfusion rate based on Helmholtz decomposition of heat flux
Objective. Thermal property (TP) maps of human tissues are useful for tumor treatment and diagnosis. In particular, the blood perfusion rate is significantly different for tumors and healthy tissues. Noninvasive techniques that reconstruct TPs from the temperature measured via magnetic resonance imaging (MRI) by solving an inverse bioheat transfer problem have been developed. A few conventional methods can reconstruct spatially varying TP distributions, but they have several limitations. First, most methods require the numerical Laplacian computation of the temperature, and hence they are sensitive to noise. In addition, some methods require the division of a region of interest (ROI) into sub-regions with homogeneous TPs using prior anatomical information, and they assume an unmeasurable initial temperature distribution. We propose a novel robust reconstruction method without the division of an ROI or the assumption of an initial temperature distribution. Approach. The proposed method estimates blood perfusion rate maps from relative temperature changes. This method avoids the computation of the Laplacian by using integral representations of the Helmholtz decomposition of the heat flux. Main Result. We compare the reconstruction results of the conventional and proposed methods using numerical simulations. The results indicate the robustness of the proposed method. Significance. This study suggests the feasibility of thermal property mapping with MRI using the robust proposed method.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (11) , 1-5
Reconstruction of the Electrical Properties in Human Bodies Based on the Estimation of the Unmeasurable Magnetic Fields
Electrical properties tomography (EPT) noninvasively reconstructs electrical properties (EPs) in human bodies from the radio-frequency magnetic field with magnetic resonance imaging. Although our previously proposed EPT method stably obtained EP distributions, EP reconstruction errors occurred because the unmeasurable magnetic field components were ignored. This study proposes a novel method to estimate the unmeasurable magnetic fields and to apply it to our previously reported EPT method. The results obtained from a numerical simulation and an experimental phantom indicate that the proposed estimation of the unmeasurable magnetic fields suppresses EP errors.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (11) , 1-5
Reconstruction of the Electrical Properties in Human Bodies Based on the Estimation of the Unmeasurable Magnetic Fields
Electrical properties tomography (EPT) noninvasively reconstructs electrical properties (EPs) in human bodies from the radio-frequency magnetic field with magnetic resonance imaging. Although our previously proposed EPT method stably obtained EP distributions, EP reconstruction errors occurred because the unmeasurable magnetic field components were ignored. This study proposes a novel method to estimate the unmeasurable magnetic fields and to apply it to our previously reported EPT method. The results obtained from a numerical simulation and an experimental phantom indicate that the proposed estimation of the unmeasurable magnetic fields suppresses EP errors.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (11) , 1-5
Circumferential Localization of a Crack in Cylindrical Ferromagnetic Rods Based on the Fourier Coefficients of the Radial Directional Magnetic Flux Leakage
In this paper, we present a novel magnetic flux leakage method to estimate the circumferential position of a crack in cylindrical ferromagnetic rods by modelling the crack as a magnetic dipole. The first-order Fourier coefficients of the radial component of the magnetic flux leakage are measured using two coils with widths proportional to | cos ϕ| and | sin ϕ|, where ϕ is the circumferential location of the rod surface. The circumferential and axial location of a crack is estimated using only two sensors, as demonstrated for an S45C cylindrical rod.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (11) , 1-5
Circumferential Localization of a Crack in Cylindrical Ferromagnetic Rods Based on the Fourier Coefficients of the Radial Directional Magnetic Flux Leakage
In this paper, we present a novel magnetic flux leakage method to estimate the circumferential position of a crack in cylindrical ferromagnetic rods by modelling the crack as a magnetic dipole. The first-order Fourier coefficients of the radial component of the magnetic flux leakage are measured using two coils with widths proportional to | cos ϕ| and | sin ϕ|, where ϕ is the circumferential location of the rod surface. The circumferential and axial location of a crack is estimated using only two sensors, as demonstrated for an S45C cylindrical rod.
- Open Access
- 1 January 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (1) , 105-118
Self-localization of monaural microphone using dipole sound sources
This paper introduces a method for indoor self-localization of a monaural microphone, which is required for various location-based services. By generating two pairs of dipole sound fields, localization is performed on each device, irrespective of the number of devices, based on orthogonal detection of observed signals and some simple operations that are feasible with limited computational resources. A method using multiple source frequencies for enhancing robustness against the effects of reflection and scattering is also proposed. The effectiveness of this method was evaluated by numerical simulations and experiments in an anechoic chamber and indoor environment, and the average errors for the azimuth and zenith angles were 4.8 and 1.9 deg, respectively, in the anechoic chamber and 21 and 11 deg, respectively, in the indoor environment.
- 1 January 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (1) , 105-118
Open AccessSelf-localization of monaural microphone using dipole sound sources
This paper introduces a method for indoor self-localization of a monaural microphone, which is required for various location-based services. By generating two pairs of dipole sound fields, localization is performed on each device, irrespective of the number of devices, based on orthogonal detection of observed signals and some simple operations that are feasible with limited computational resources. A method using multiple source frequencies for enhancing robustness against the effects of reflection and scattering is also proposed. The effectiveness of this method was evaluated by numerical simulations and experiments in an anechoic chamber and indoor environment, and the average errors for the azimuth and zenith angles were 4.8 and 1.9 deg, respectively, in the anechoic chamber and 21 and 11 deg, respectively, in the indoor environment.