KHKeisuke Hasegawa

Keisuke Hasegawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keisuke Hasegawa has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multiple ultrasound image generation based on tuned alignment of amplitude hologram over spatially non-uniform ultrasound source

    by Keisuke Hasegawa

    In this study, a method for readily and inexpensively generating intense midair ultrasound fields that are reconfigurable in real-time is proposed for applications of midair nonlinear acoustic effects. To generate such ultrasound fields, specifically designed ultrasound sources or phased arrays of ultrasound transducers are conventionally used. The former can be more readily fabricated but cannot drastically reconfigure the generated ultrasound field, and the latter can create electronically controllable ultrasound fields but is much more expensive and difficult to implement. The proposed method utilizes a planar ultrasound source with a fixed surface vibration pattern and a newly designed amplitude mask, which partially covers source emission to form a predetermined ultrasound field with a corresponding specific spatial pattern when placed at a specific position. This new mask allows for switching of the generated fields among several presets by changing the mask's position on the source. The proposed technique requires only slight mechanical translation of the mask over the source to instantly reconfigure the resulting midair ultrasound field. This method enables the creation of a reconfigurable ultrasound field with a large source aperture in a significantly inexpensive, practical setup, potentially extending the workspace of current midair ultrasound applications to a whole-room scale.

  • Real-time midair manipulation of objects larger than wavelength using multiple facing pairs of acoustic vortex beams

    by Takeru Momoki, Keisuke Hasegawa

    Acoustic levitation is a technique that traps solids or liquids in the air. Recently, many studies on stably levitating and manipulating objects larger than the midair ultrasound wavelength have been proposed based on approaches such as the design of a spatially complicated sound field according to the shape of the target object or temporal switching of vortex beams. However, real-time midair manipulation of objects larger than the wavelength has not been demonstrated using those methods due to computational costs for output optimization or reduced output efficiency. To overcome these issues, here we propose a different approach based on the use of multiple facing pairs of acoustic vortex beams for levitating objects larger than the wavelength in the air, which can be applied to real-time midair object manipulation with maximum transducer output efficiency. In this paper, we show that a specific combination of topological charge and phase difference in paired beams can maximize the levitation performance. We experimentally demonstrate stable levitation and real-time manipulation of a midair object larger than the wavelength. This study will drastically widen the scope of target objects for real-time midair manipulation by mitigating the size limit, which will contribute to application scenarios in acoustic levitation handling objects that have not been considered feasible.


  • Visualization of sound source positions using pinpoint nonlinear secondary emission by ultrasound focus scanning

    by Shihori Kozuka, Keisuke Hasegawa, Takaaki Nara

    This study proposes a method for visualizing sound fields utilizing midair nonlinear acoustic phenomena in a spatially localized manner. Conventional microphone-array-based sound field visualization method requires multi-channel synchronous signal processing that handles phase information of the observed waveforms, which inevitably hinders production of cost-effective recording devices. Additionally, the inserted microphones themselves can disturb the measured sound field, and artifacts owing to the spacing between microphones may arise. To address these issues, the study introduces a measurement method that involves scanning a focal point of converging ultrasonic beams in the target sound field. The ultrasonic focus generates secondary parametric waves via frequency modulation of the target sound field only near the focal point due to the acoustic nonlinear effect. The visualization of the target field is completed by demodulating these waves measured with a single immobilized microphone located outside the field. This technique achieves spatial selectivity of recording via steering of the ultrasonic focus serving as a parametric probe, allowing the target sound field information to be reconstructed from a monaural recorded signal. This approach of sound field visualization ranging over hundreds of millimeters is based on a single-channel recording, where no recording elements densely arranged in the target sound field are required.

  • Aerial Push-Button With Two-Stage Tactile Feedback Using Reflected Airborne Ultrasound Focus

    by Hiroya Sugawara, Masaya Takasaki, Keisuke Hasegawa

    We developed a new aerial push-button with tactile feedback using focused airborne ultrasound. This study has two significant novelties compared to past related studies: 1) ultrasound emitters are equipped behind the user's finger and reflected ultrasound emission that is focused just above the solid plane placed under the finger presents tactile feedback to a finger pad, and 2) tactile feedback is presented at two stages during pressing motion; at the time of pushing the button and withdrawing the finger from it. The former has a significant advantage in apparatus implementation in that the input surface of the device can be composed of a generic thin plane including touch panels, potentially capable of presenting input touch feedback only when the user touches objects on the screen. We experimentally found that the two-stage tactile presentation is much more effective in strengthening perceived tactile stimulation and believability of input completion when compared with a conventional single-stage method. This study proposes a composition of an aerial push-button in much more practical use than ever. The proposed system composition is expected to be one of the simplest frameworks in the airborne ultrasound tactile interface.


  • Focusing of airborne ultrasound emitted by a flexurally vibrating plate using a transmission mask with spatially designed holes

    by Keisuke Hasegawa, Masaya Fujimori, Masaya Takasaki

    We propose a focusing method of intense midair ultrasound out of ultrasonic emission from a single flexurally vibrating plate partially covered with a purposely designed amplitude mask. Many applications relying on nonlinear acoustic effects, such as radiation force employed in acoustic levitation, have been devised. For those applications, focused intense airborne ultrasound is conventionally formed using phased arrays of transducers or sound sources with specific fabricated shapes. However, the former strategies are costly, and the latter may require minute three-dimensional fabrication processes, which both hinder their utilization, especially in constructing a large ultrasound-emitting aperture. Our method offers a possible solution for this, where the amplitude masks are designed depending on the positions of nodes and antinodes of the vibrating plate. We experimentally demonstrate the successful formation of midair ultrasound focus at a desired position, which is localized in a region whose diameter is less than a few wavelengths. Our method only requires a monolithic plate, a driving transducer under the plate, and an amplitude mask fabricated out of laser machining of an acrylic plate. Magnification of the spatial scale of ultrasound apertures based on our method is much more readily and affordably achieved than conventional methods, leading to new midair ultrasound applications with the whole-room workspace.


  • Open Access

    Frequency shift of parametric sound by face-to-face pair of sources in relative motion

    by Shun Kotoku, Reita Maeno, Keisuke Hasegawa

    This paper reports an acoustic phenomenon regarding a parametric sound source (also referred to as a parametric array): a secondary sound wave is generated from the nonlinear interaction of multiple primary sound waves with varied frequency components, particularly when two relatively moving sound sources face each other. It was found that the frequency of the secondary wave fluctuated according to the source movement and provided a theoretical explanation for this phenomenon. It is experimentally demonstrated that this frequency shift was approximately proportional to the velocity of the moving source toward the fixed source and to the driving frequency of the moving source. This phenomenon has much in common with the Doppler's effect, but its unique property is that the frequency shift depends on neither the observation position nor the source velocity toward the observer. These sound generation principles enable measurement of the velocity of slowly moving sound sources while maintaining a low-modulation frequency band and a short measurement time. This phenomenon can potentially be applied to an alternative approach for acoustic noncontact velocimetry of moving objects.

  • Open Access

    Airborne ultrasound focusing aperture with binary amplitude mask over planar ultrasound emissions

    by Masatake Kitano, Keisuke Hasegawa

    Phased arrays of airborne ultrasound transducers are widely utilized as a key technology to achieve mid-air convergence of intense ultrasound, which is applied to a variety of systems, such as contactless tactile presentation, acoustic levitation and its application, mid-air-flow acceleration, etc. However, it requires considerably precise phase control with temporally severe synchronization between elements, which leads to difficulty in scaling up the entire system beyond the tabletop size as most of the current application systems. Here, we propose a much simpler and easier scaling-up method of airborne ultrasound convergence, where a binary amplitude mask that serves as a Fresnel Zone Plate (FZP) is placed on the planar in-phase ultrasound sources. We experimentally demonstrate that the FZP-based ultrasound focusing achieved a spatial resolution that is comparable to conventional methods, based on the use of phase-controlled transducers. The ultrasound foci created using FZPs are sufficiently intense for most application scenarios that are currently in practical use. We also determine favorable side effects of our method suppressing grating lobes, which is inevitable with the conventional phase-controlling method. The FZPs and planar ultrasound sources are both readily implemented with inexpensive ingredients and components. The result of our study contributes to upsizing dimensions in which a mid-air convergent ultrasound field is successfully generated. Accordingly, unprecedented application scenarios that target the entire room as the workspace will be possible.