Ammar Zeghloul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ammar Zeghloul has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Abdelwahid Azzi
Faculty of Mechanical and Process Engineering, University of Sciences and Technology Houari Boumedien, Algiers, Algeria
5 shared publications- Abbas H. Hasan
Faculty of Science and Engineering, University of Hull-Chemical Engineering, Hull, UK
4 shared publications Faiza Saidj
FGMGP/LTPMP, University of Sciences and Technology Houari Boumedien (USTHB), Algiers, Algeria
4 shared publicationsHiba Bouyahiaoui
FGMGP/LTPMP, University of Sciences and Technology Houari Boumedien (USTHB), Algiers, Algeria
4 shared publications- Abdelwahid Azzi
Faculty of Mechanical and Process Engineering, Université des Sciences et de la Technologie Houari Boumediène, BP 32 El Alia, Algiers 16111, Algeria
3 shared publications Abdelkader Messilem
FGMGP/LTPMP, University of Sciences and Technology Houari Boumedien (USTHB), Algiers, Algeria
2 shared publications
Latest Publications
- Open Access
- 19 December 2025
- Published by Elsevier in Applications in Engineering Science
- Vol. 25
How deformable Gurney flaps combined to droop nose leading edge affecting the output power of flapping wind turbine?
- 19 December 2025
- Published by Elsevier in Applications in Engineering Science
- Vol. 25
Open AccessHow deformable Gurney flaps combined to droop nose leading edge affecting the output power of flapping wind turbine?
- Open Access
- 1 July 2023
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 16 (7) , 1499-1510
Improved Drift Flux Void Fraction Model for Horizontal Gas-liquid Intermittent Flow
Drift Flux model is widely used in literature to predict void fraction in two-phase gas-liquid flow. Drift flux model has been used for all flow regimes. The distribution parameter implemented in the model is very crucial for the accuracy of the model. A new distribution parameter was developed in this paper as a function of two dimensionless parameters and flow regime (slug or plug). The new model showed a superior predicted void fraction accuracy over all available models in literature. In this paper, the influence of the flow regimes was implemented in the formulation of the drift flux model distribution parameter for the first time in literature. The drift velocity was found to be negligible in the horizontal configuration. The proposed model was validated using unbiased data from literature from different sources and for a wide range of liquid viscosity from water up to high viscosity oil (600 cP) and pipe diameter from 19 mm up to 152 mm. The mean relative absolute error of the proposed model using all data bank is around 16% while the least error model available in literature is around 19%. Moreover, the most recent models of Rassame and Hibiki (2018) and Kong et al. (2018b) give 33% and 50%, respectively.
- 1 July 2023
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 16 (7) , 1499-1510
Open AccessImproved Drift Flux Void Fraction Model for Horizontal Gas-liquid Intermittent Flow
Drift Flux model is widely used in literature to predict void fraction in two-phase gas-liquid flow. Drift flux model has been used for all flow regimes. The distribution parameter implemented in the model is very crucial for the accuracy of the model. A new distribution parameter was developed in this paper as a function of two dimensionless parameters and flow regime (slug or plug). The new model showed a superior predicted void fraction accuracy over all available models in literature. In this paper, the influence of the flow regimes was implemented in the formulation of the drift flux model distribution parameter for the first time in literature. The drift velocity was found to be negligible in the horizontal configuration. The proposed model was validated using unbiased data from literature from different sources and for a wide range of liquid viscosity from water up to high viscosity oil (600 cP) and pipe diameter from 19 mm up to 152 mm. The mean relative absolute error of the proposed model using all data bank is around 16% while the least error model available in literature is around 19%. Moreover, the most recent models of Rassame and Hibiki (2018) and Kong et al. (2018b) give 33% and 50%, respectively.
- 30 April 2023
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering
- Vol. 48 (1) , 163-175
Improved Aeration Using Perforated Venturi Throat of a Vertical Liquid Jet System with Downcomer
- 30 April 2023
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering
- Vol. 48 (1) , 163-175
Improved Aeration Using Perforated Venturi Throat of a Vertical Liquid Jet System with Downcomer
- 8 February 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (19) , 4454-4467
Two-phase flow in a vertical concentric annulus: Pressure drop and flow configuration
This paper presents experimental investigation of flow configurations and pressure drop of single-phase water flow and two-phase air-water flow in a vertical annulus. The annular test section had a concentric geometry with a casing and tubing diameter of 50 and 33.7 mm, respectively. The superficial velocity conditions of the liquid and gas were ranged 0.08–1.56 and 0–3.56 m/s, respectively. The combination of these superficial velocities produces the bubbly, slug and churn flow regimes. The identification of the flow patterns shows that the Mishima and Ishii model is the most relevant to highlight the flow transition. The measured friction factors were compared to prediction models from the literature. It was deduced that the model proposed by Gunn and Darling underestimates the liquid friction factor in the annulus. The measured pressure drops and the dimensionless pressure gradient evolution exhibits different slopes that characterize each flow pattern. The standard deviation and structure frequency describe specific ranges for each flow pattern. These two parameters can also be used for the prediction of flow patterns.
- 8 February 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (19) , 4454-4467
Two-phase flow in a vertical concentric annulus: Pressure drop and flow configuration
This paper presents experimental investigation of flow configurations and pressure drop of single-phase water flow and two-phase air-water flow in a vertical annulus. The annular test section had a concentric geometry with a casing and tubing diameter of 50 and 33.7 mm, respectively. The superficial velocity conditions of the liquid and gas were ranged 0.08–1.56 and 0–3.56 m/s, respectively. The combination of these superficial velocities produces the bubbly, slug and churn flow regimes. The identification of the flow patterns shows that the Mishima and Ishii model is the most relevant to highlight the flow transition. The measured friction factors were compared to prediction models from the literature. It was deduced that the model proposed by Gunn and Darling underestimates the liquid friction factor in the annulus. The measured pressure drops and the dimensionless pressure gradient evolution exhibits different slopes that characterize each flow pattern. The standard deviation and structure frequency describe specific ranges for each flow pattern. These two parameters can also be used for the prediction of flow patterns.
- 11 February 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 234 (12) , 2349-2359
Single- and two-phase pressure drop through vertical Venturis
An experimental investigation of the pressure drops measurements in a Venturi placed in a vertical pipe is achieved. Venturis with diameter ratios equal to 0.4, 0.55, and 0.75 were employed. Differential pressure transducers were used to measure the pressure drop between the Venturi inlet and the throat sections. The void fraction was measured upstream the Venturi using a conductance probe technique. Air and water superficial velocities ranges were chosen to cover single-phase flow and bubbly, slug, and churn flow regimes. The single-phase pressure drop increases with the liquid superficial velocity. The Venturi pressure drop coefficient increases with decreasing the Venturi area ratio. The discharge coefficient increases slightly with this ratio and approaches a value of unity at high Reynolds number. The two-phase flow pressure drop and the multiplier coefficient increase with the gas superficial velocity and with decreasing the area ratio. Dimensionless pressure drop decreases with increasing the liquid to gas superficial velocity ratio and approaches an asymptotic value at high ratio (greater than 10). This value matches the single-phase flow dimensionless pressure drop value at high Reynolds number. The Venturi with area ratio equal to 0.55 was shown to correlate well the two-phase multiplier and the liquid holdup.
- 11 February 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 234 (12) , 2349-2359
Single- and two-phase pressure drop through vertical Venturis
An experimental investigation of the pressure drops measurements in a Venturi placed in a vertical pipe is achieved. Venturis with diameter ratios equal to 0.4, 0.55, and 0.75 were employed. Differential pressure transducers were used to measure the pressure drop between the Venturi inlet and the throat sections. The void fraction was measured upstream the Venturi using a conductance probe technique. Air and water superficial velocities ranges were chosen to cover single-phase flow and bubbly, slug, and churn flow regimes. The single-phase pressure drop increases with the liquid superficial velocity. The Venturi pressure drop coefficient increases with decreasing the Venturi area ratio. The discharge coefficient increases slightly with this ratio and approaches a value of unity at high Reynolds number. The two-phase flow pressure drop and the multiplier coefficient increase with the gas superficial velocity and with decreasing the area ratio. Dimensionless pressure drop decreases with increasing the liquid to gas superficial velocity ratio and approaches an asymptotic value at high ratio (greater than 10). This value matches the single-phase flow dimensionless pressure drop value at high Reynolds number. The Venturi with area ratio equal to 0.55 was shown to correlate well the two-phase multiplier and the liquid holdup.
- 1 January 2020
- Published by Elsevier in Journal of Natural Gas Science and Engineering
- Vol. 73
Vertical upward and downward churn flow: Similarities and differences
- 1 January 2020
- Published by Elsevier in Journal of Natural Gas Science and Engineering
- Vol. 73
Vertical upward and downward churn flow: Similarities and differences
- 1 September 2018
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 108, 428-437
Experimental study of the characteristics of an upward two-phase slug flow in a vertical pipe
- 1 September 2018
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 108, 428-437
Experimental study of the characteristics of an upward two-phase slug flow in a vertical pipe
- 1 March 2018
- Published by Elsevier in Journal of Petroleum Science and Engineering
- Vol. 162, 12-21
Experimental investigation of a vertically downward two-phase air-water slug flow
- 1 March 2018
- Published by Elsevier in Journal of Petroleum Science and Engineering
- Vol. 162, 12-21
Experimental investigation of a vertically downward two-phase air-water slug flow
- 11 October 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 232 (18) , 3281-3299
Behavior and pressure drop of an upwardly two-phase flow through multi-hole orifices
Experimental results on hydrodynamic behavior and pressure drop of two-phase mixture flowing upwardly in a pipe containing single- and/or multi-hole orifice plate are presented. It was found from the measurement of the void fraction upstream and downstream the orifices that the flow behavior is significantly affected by the layout of the orifice plate used and the flow starts to recover after approximately 7D downstream the orifice. Furthermore, increasing orifice holes number results in decreasing the slip ratio. The standard deviation of the void fraction was used to identify the flow pattern before and after the orifices and found that the critical threshold transition occurred at a standard deviation of 0.2. The flow homogenization necessitates a minimum value of the liquid superficial velocity to occur, and the position where it takes place depends on this velocity and on the orifice holes number. It was also inferred from the two-phase pressure drop data across the orifices that three different flow regimes, where the transition between bubbly-to-slug and slug-to-churn flow, can be identified. An assessment of the predicted two-phase flow multiplier using some previous models dedicated to single-hole orifice was achieved; and found that the model proposed by Simpson et al. is the most reliable one. Single-phase pressure drop was also measured and compared with correlations from literature.
- 11 October 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 232 (18) , 3281-3299
Behavior and pressure drop of an upwardly two-phase flow through multi-hole orifices
Experimental results on hydrodynamic behavior and pressure drop of two-phase mixture flowing upwardly in a pipe containing single- and/or multi-hole orifice plate are presented. It was found from the measurement of the void fraction upstream and downstream the orifices that the flow behavior is significantly affected by the layout of the orifice plate used and the flow starts to recover after approximately 7D downstream the orifice. Furthermore, increasing orifice holes number results in decreasing the slip ratio. The standard deviation of the void fraction was used to identify the flow pattern before and after the orifices and found that the critical threshold transition occurred at a standard deviation of 0.2. The flow homogenization necessitates a minimum value of the liquid superficial velocity to occur, and the position where it takes place depends on this velocity and on the orifice holes number. It was also inferred from the two-phase pressure drop data across the orifices that three different flow regimes, where the transition between bubbly-to-slug and slug-to-churn flow, can be identified. An assessment of the predicted two-phase flow multiplier using some previous models dedicated to single-hole orifice was achieved; and found that the model proposed by Simpson et al. is the most reliable one. Single-phase pressure drop was also measured and compared with correlations from literature.