Fabrizio Tamarri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fabrizio Tamarri has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Roberta Nipoti
CNR-IMM of Bologna, Bologna, Italy
5 shared publications - Andrea Scorzoni
Department of Engineering, University of Perugia, Perugia, Italy
4 shared publications - Fulvio Mancarella
Institute of Microelectronics and Microsystems, CNR, Bologna, Italy
4 shared publications - Gian Carlo Cardinali
IMM - Institute for Microelectronics and Microsystems, CNR - National Research Council, Via P.Gobetti 101, Bologna, Italy
4 shared publications - Alberto Roncaglia
Institute of Microelectronics and Microsystems, CNR, Bologna, Italy
3 shared publications Antonella Poggi
CNR-IMM
3 shared publications
Latest Publications
- 14 May 2012
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 717-720, 985-988
Fully Ion Implanted Vertical p-i-n Diodes on High Purity Semi-Insulating 4H-SiC Wafers
The fabrication of a fully ion-implanted and microwave annealed vertical p-i-n diode using high purity semi-insulating 4H-SiC substrate has been demonstrated for the first time. The thickness of the intrinsic region is the wafer thickness 350 µm. The anode and cathode of the diode have been doped with Al and P, respectively, to concentrations of few times 1020 cm-3 by ion implantation. The post implantation annealing has been performed by microwave heating the samples up to 2100°C. The device rectifying behavior indicates that a carrier modulation takes place in the bulk intrinsic region.
- 14 May 2012
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 717-720, 985-988
Fully Ion Implanted Vertical p-i-n Diodes on High Purity Semi-Insulating 4H-SiC Wafers
The fabrication of a fully ion-implanted and microwave annealed vertical p-i-n diode using high purity semi-insulating 4H-SiC substrate has been demonstrated for the first time. The thickness of the intrinsic region is the wafer thickness 350 µm. The anode and cathode of the diode have been doped with Al and P, respectively, to concentrations of few times 1020 cm-3 by ion implantation. The post implantation annealing has been performed by microwave heating the samples up to 2100°C. The device rectifying behavior indicates that a carrier modulation takes place in the bulk intrinsic region.
- Open Access
- 1 January 2010
- Published by Elsevier in Procedia Engineering
- Vol. 5, 1344-1347
Micromachined gas calibration sources based on nanometric depth microchannels
- 1 January 2010
- Published by Elsevier in Procedia Engineering
- Vol. 5, 1344-1347
Open AccessMicromachined gas calibration sources based on nanometric depth microchannels
- 2 March 2009
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 615-617, 761-764
Effects of N Implantation before Gate Oxidation on the Performance of 4H-SiC MOSFET
The electrical characteristics of MOSFETs fabricated on 4H-SiC with a process based on N implantation in the channel region before the growth of the gate oxide are reported as a function of the N concentration at the SiO2/SiC interface up to 6 1019 cm-3. The field effect mobility improves with increasing N concentration. At room temperature values change from 4 cm2/Vs for the not implanted sample up to 42 cm2/Vs for the sample with the highest N concentration. Furthermore, the field effect mobility increases with temperature and presents values above 60 cm2/Vs at 200 °C. The MOSFETs with the better electrical characteristics (higher mobility, lower threshold voltage, lower subthreshold swing) were fabricated by a low thermal budget oxidation process, thank to the use of a high N implantation dose able to produce an amorphous SiC surface layer. A strong correlation among the increasing of the N concentration at the SiO2/SiC interface, the reduction of the interface state density located near the conduction band and the improvement of the MOSFETs performance was obtained.
- 2 March 2009
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 615-617, 761-764
Effects of N Implantation before Gate Oxidation on the Performance of 4H-SiC MOSFET
The electrical characteristics of MOSFETs fabricated on 4H-SiC with a process based on N implantation in the channel region before the growth of the gate oxide are reported as a function of the N concentration at the SiO2/SiC interface up to 6 1019 cm-3. The field effect mobility improves with increasing N concentration. At room temperature values change from 4 cm2/Vs for the not implanted sample up to 42 cm2/Vs for the sample with the highest N concentration. Furthermore, the field effect mobility increases with temperature and presents values above 60 cm2/Vs at 200 °C. The MOSFETs with the better electrical characteristics (higher mobility, lower threshold voltage, lower subthreshold swing) were fabricated by a low thermal budget oxidation process, thank to the use of a high N implantation dose able to produce an amorphous SiC surface layer. A strong correlation among the increasing of the N concentration at the SiO2/SiC interface, the reduction of the interface state density located near the conduction band and the improvement of the MOSFETs performance was obtained.
- 1 September 2008
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 600-603, 1027-1030
Room Temperature Annealing Effects on Leakage Current of Ion Implanted p+n 4H-SiC Diodes
The current-voltage characteristics of Al+ implanted 4H-SiC p+n junctions show an important reduction of leakage currents with diode aging at room temperature. The case of a family of diodes that immediately after manufacture had forward current density increasing from 10-9 to 10-6 A/cm2 when biased from 0 and 2 V, and had a reverse leakage current density of @ 5×10-7 A/cm2 when biased at 100 V, is here presented and discussed. During diode manufacturing a post implantation annealing at 1600 °C for 30 min was followed by a 1000 °C 1 min treatment for metal contacts alloying. After 700 days of storage at room temperature, the diode reverse current density reached an asymptotical value of @ 4×10-11 A/cm2 that is four order of magnitude lower than the initial one. A 430 °C annealing that was made after 366 days is responsible of a decrease of one of these four orders of magnitude, but it does not interrupt the decreasing trend versus increasing time. This same annealing has been effective also for minimizing forward current for bias < 2 V, and sticking the diode turn-on voltage on 1.4 V and the current trend on an ideality factor of 2. These results show that in Al+ implanted 4H-SiC p+n junction there are defects that have an annihilation dynamic at very low temperatures, i.e. room temperature and 430 °C.
- 1 September 2008
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 600-603, 1027-1030
Room Temperature Annealing Effects on Leakage Current of Ion Implanted p+n 4H-SiC Diodes
The current-voltage characteristics of Al+ implanted 4H-SiC p+n junctions show an important reduction of leakage currents with diode aging at room temperature. The case of a family of diodes that immediately after manufacture had forward current density increasing from 10-9 to 10-6 A/cm2 when biased from 0 and 2 V, and had a reverse leakage current density of @ 5×10-7 A/cm2 when biased at 100 V, is here presented and discussed. During diode manufacturing a post implantation annealing at 1600 °C for 30 min was followed by a 1000 °C 1 min treatment for metal contacts alloying. After 700 days of storage at room temperature, the diode reverse current density reached an asymptotical value of @ 4×10-11 A/cm2 that is four order of magnitude lower than the initial one. A 430 °C annealing that was made after 366 days is responsible of a decrease of one of these four orders of magnitude, but it does not interrupt the decreasing trend versus increasing time. This same annealing has been effective also for minimizing forward current for bias < 2 V, and sticking the diode turn-on voltage on 1.4 V and the current trend on an ideality factor of 2. These results show that in Al+ implanted 4H-SiC p+n junction there are defects that have an annihilation dynamic at very low temperatures, i.e. room temperature and 430 °C.
- 15 September 2007
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 556-557, 639-642
Characterization of MOS Capacitors Fabricated on n-type 4H-SiC Implanted with Nitrogen at High Dose
Aiming to minimize the interface state density, we fabricated MOS capacitors on n-type 4H-SiC by using wet oxidation of nitrogen implanted layers. We investigated a wide range of implantation dose, including a high dose able to amorphise a surface SiC layer with the intent to reduce the oxidation time. The oxide quality and the SiO2-SiC interface properties were characterized by capacitance-voltage measurements of the MOS capacitors. The proposed process, in which nitrogen is ion-implanted on SiC layer before a wet oxidation, is effective to reduce the density of interface states near the conduction band edge if a high concentration of nitrogen is introduced at the SiO2-SiC interface. We found that only the nitrogen implanted at the oxide-SiC interface reduces the interface states and we did not observe the generation of fixed positive charges in the oxide as a consequence of nitrogen implantation. Furthermore, the concentration of the slow traps evaluated from the Slow Trap Profiling technique was low and did not depend on the nitrogen implantation fluence.
- 15 September 2007
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 556-557, 639-642
Characterization of MOS Capacitors Fabricated on n-type 4H-SiC Implanted with Nitrogen at High Dose
Aiming to minimize the interface state density, we fabricated MOS capacitors on n-type 4H-SiC by using wet oxidation of nitrogen implanted layers. We investigated a wide range of implantation dose, including a high dose able to amorphise a surface SiC layer with the intent to reduce the oxidation time. The oxide quality and the SiO2-SiC interface properties were characterized by capacitance-voltage measurements of the MOS capacitors. The proposed process, in which nitrogen is ion-implanted on SiC layer before a wet oxidation, is effective to reduce the density of interface states near the conduction band edge if a high concentration of nitrogen is introduced at the SiO2-SiC interface. We found that only the nitrogen implanted at the oxide-SiC interface reduces the interface states and we did not observe the generation of fixed positive charges in the oxide as a consequence of nitrogen implantation. Furthermore, the concentration of the slow traps evaluated from the Slow Trap Profiling technique was low and did not depend on the nitrogen implantation fluence.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1661-1664
Material Properties Measurement and Numerical Simulation for Characterization of Ultra-Low-Power Consumption Hotplates
The results of a thorough thermoelectric characterization, performed both in a vacuum chamber and at atmospheric pressure, of ultra-low-power hotplates based on suspended structures with different layouts are presented in this work and compared with thermoelectric 2D and thermal 3D finite elements simulations. Electrical and thermal properties of the thin films used in the devices have been also measured, involving appropriate on-chip test structures, and their values were employed in both 2D and 3D model. Temperature vs. heating power experimental curves showed the great influence of conduction through air on power consumption and an excellent agreement with the simulated results.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1661-1664
Material Properties Measurement and Numerical Simulation for Characterization of Ultra-Low-Power Consumption Hotplates
The results of a thorough thermoelectric characterization, performed both in a vacuum chamber and at atmospheric pressure, of ultra-low-power hotplates based on suspended structures with different layouts are presented in this work and compared with thermoelectric 2D and thermal 3D finite elements simulations. Electrical and thermal properties of the thin films used in the devices have been also measured, involving appropriate on-chip test structures, and their values were employed in both 2D and 3D model. Temperature vs. heating power experimental curves showed the great influence of conduction through air on power consumption and an excellent agreement with the simulated results.
- 15 October 2006
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 527-529, 819-822
Ion Implanted p+/n Diodes: Post-Implantation Annealing in a Silane Ambient in a Cold-Wall Low-Pressure CVD Reactor
This work reports the realization and characterization of 4H-SiC p+/n diodes with the p+ anodes made by Al+ ion implantation at 400°C and post-implantation annealing in silane ambient in a cold-wall low-pressure CVD reactor. The Al depth profile was almost box shaped with a height of 6×1019 cm-3 and a depth of 160 nm. Implant anneals were performed in the temperature range from 1600°C to 1700°C. As the annealing temperature was increased, the silane flow rate was also increased. This annealing process yields a smooth surface with a roughness of the implanted area of 1.7 - 5.3 nm with increasing annealing temperature. The resistivity of the implanted layer, measured at room temperature, decreased for increasing annealing temperatures with a minimum value of 1.4 0-cm measured for the sample annealed at 1700°C. Considering only the current-voltage characteristic of a diode that could be modeled as an abrupt p/n junction within the frame of the Shockley theory, the diode process yield and the diode leakage current decreased, respectively, from 93% to 47% and from 2×10-7 Acm-2 to 1×10-8 Acm-2 at 100 V reverse bias, for increasing post implantation annealing temperature.
- 15 October 2006
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 527-529, 819-822
Ion Implanted p+/n Diodes: Post-Implantation Annealing in a Silane Ambient in a Cold-Wall Low-Pressure CVD Reactor
This work reports the realization and characterization of 4H-SiC p+/n diodes with the p+ anodes made by Al+ ion implantation at 400°C and post-implantation annealing in silane ambient in a cold-wall low-pressure CVD reactor. The Al depth profile was almost box shaped with a height of 6×1019 cm-3 and a depth of 160 nm. Implant anneals were performed in the temperature range from 1600°C to 1700°C. As the annealing temperature was increased, the silane flow rate was also increased. This annealing process yields a smooth surface with a roughness of the implanted area of 1.7 - 5.3 nm with increasing annealing temperature. The resistivity of the implanted layer, measured at room temperature, decreased for increasing annealing temperatures with a minimum value of 1.4 0-cm measured for the sample annealed at 1700°C. Considering only the current-voltage characteristic of a diode that could be modeled as an abrupt p/n junction within the frame of the Shockley theory, the diode process yield and the diode leakage current decreased, respectively, from 93% to 47% and from 2×10-7 Acm-2 to 1×10-8 Acm-2 at 100 V reverse bias, for increasing post implantation annealing temperature.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1235-1238
A comparison among different technological processes for the fabrication of polysilicon-based thermoelectric transducers
We propose a comparison among different solutions for realizing polysilicon thermoelectric transducers, with five different types of thermoelements based on Al/polysilicon and two level polysilicon design, using different doping (of p and n-type) for the poly layers. The device performances are evaluated on a test geometry with electrical measurements and the performance obtained with the various solutions are compared.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1235-1238
A comparison among different technological processes for the fabrication of polysilicon-based thermoelectric transducers
We propose a comparison among different solutions for realizing polysilicon thermoelectric transducers, with five different types of thermoelements based on Al/polysilicon and two level polysilicon design, using different doping (of p and n-type) for the poly layers. The device performances are evaluated on a test geometry with electrical measurements and the performance obtained with the various solutions are compared.