K-edge imaging with the XPAD3 hybrid pixel detector, direct comparison of CdTe and Si sensors
- 2 July 2015
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (14) , 5497-5511
Abstract
We investigate the improvement from the use of high-Z CdTe sensors for pre-clinical K-edge imaging with the hybrid pixel detectors XPAD3. We compare XPAD3 chips bump bonded to Si or CdTe sensors in identical experimental conditions. Image performance for narrow energy bin acquisitions and contrast-to-noise ratios of K-edge images are presented and compared. CdTe sensors achieve signal-to-noise ratios at least three times higher than Si sensors within narrow energy bins, thanks to their much higher detection efficiency. Nevertheless Si sensors provide better contrast-to-noise ratios in K-edge imaging when working at equivalent counting statistics, due to their better estimation of the attenuation coefficient of the contrast agent. Results are compared to simulated data in the case of the XPAD3/Si detector. Good agreement is observed when including charge sharing between pixels, which have a strong impact on contrast-to-noise ratios in K-edge images.Keywords
This publication has 13 references indexed in Scilit:
- How spectroscopic x-ray imaging benefits from inter-pixel communicationPhysics in Medicine & Biology, 2014
- Comparison of three types of XPAD3.2/CdTe single chip hybrids for hard X-ray applications in material science and biomedical imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- First K-Edge Imaging With a Micro-CT Based on the XPAD3 Hybrid Pixel DetectorIEEE Transactions on Nuclear Science, 2012
- Optimization of K‐edge imaging with spectral CTMedical Physics, 2012
- Biomedical spectral x-ray imaging: promises and challenges2011
- Study of the charge sharing effect in the photon-counting pixel detector XPAD3-SNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Room-temperature spectroscopic performance of a very-large area silicon drift detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- PILATUS: A single photon counting pixel detector for X-ray applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Imaging performance of the hybrid pixel detectors XPAD3-SPhysics in Medicine & Biology, 2009
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976