Adrian S. Dragovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adrian S. Dragovic has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Aaron M. Collins
RMIT Univ. (Australia)
2 shared publications - Christofer Bester
Department of Surgery (Otolaryngology), The University of Melbourne, Melbourne, VIC, Australia
2 shared publications Luke Campbell
Department of Surgery - Otolaryngology, University of Melbourne, RVEEH, East Melbourne, VIC, Australia
2 shared publicationsA K Stringer
Department of Otolaryngology,Royal Victorian Eye and Ear Hospital,East Melbourne,Australia
1 shared publication- A. K. Stringer
A Department of Otolaryngology , The Royal Victorian Eye and Ear Hospital , 32 Gisborne St, East Melbourne 3002 , Victoria , Australia
1 shared publication Amy Hampson
Otolaryngology, Department of Surgery, University of Melbourne, East Melbourne 3002, Australia
1 shared publication
Latest Publications
- 1 December 2020
- Published by Elsevier in Hearing Research
- Vol. 398, 108094
Cochlear microphonic latency predicts outer hair cell function in animal models and clinical populations
- 1 December 2020
- Published by Elsevier in Hearing Research
- Vol. 398, 108094
Cochlear microphonic latency predicts outer hair cell function in animal models and clinical populations
- Open Access
- 29 October 2018
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 132 (11) , 1000-1006
Scalar localisation of peri-modiolar electrodes and speech perception outcomes
Objective: To identify the intracochlear electrode position in cochlear implant recipients and determine the correlation to speech perception for two peri-modiolar electrode arrays.Methods: Post-operative cone-beam computed tomography images of 92 adult recipients of the ‘CI512’ electrode and 18 adult recipients of the ‘CI532’ electrode were analysed. Phonemes scores were recorded pre-implantation, and at 3 and 12 months post-implantation.Results: All CI532 electrodes were wholly within scala tympani. Of the 79 CI512 electrodes intended to be in scala tympani, 58 (73 per cent) were in scala tympani, 14 (17 per cent) were translocated and 7 (9 per cent) were wholly in scala vestibuli. Thirteen CI512 electrodes were deliberately inserted into scala vestibuli. Speech perception scores for post-lingual recipients were higher in the scala tympani group (69.1 per cent) compared with the scala vestibuli (54.2 per cent) and translocation (50 per cent) groups (p< 0.05). Electrode location outside of scala tympani independently resulted in a 10.5 per cent decrease in phoneme scores.Conclusion: Cone-beam computed tomography was valuable for demonstrating electrode position. The rate of scala tympani insertion was higher in CI532 than in CI512 electrodes. Scala vestibuli insertion and translocation were associated with poorer speech perception outcomes.
- 29 October 2018
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 132 (11) , 1000-1006
Open AccessScalar localisation of peri-modiolar electrodes and speech perception outcomes
Objective: To identify the intracochlear electrode position in cochlear implant recipients and determine the correlation to speech perception for two peri-modiolar electrode arrays.Methods: Post-operative cone-beam computed tomography images of 92 adult recipients of the ‘CI512’ electrode and 18 adult recipients of the ‘CI532’ electrode were analysed. Phonemes scores were recorded pre-implantation, and at 3 and 12 months post-implantation.Results: All CI532 electrodes were wholly within scala tympani. Of the 79 CI512 electrodes intended to be in scala tympani, 58 (73 per cent) were in scala tympani, 14 (17 per cent) were translocated and 7 (9 per cent) were wholly in scala vestibuli. Thirteen CI512 electrodes were deliberately inserted into scala vestibuli. Speech perception scores for post-lingual recipients were higher in the scala tympani group (69.1 per cent) compared with the scala vestibuli (54.2 per cent) and translocation (50 per cent) groups (p< 0.05). Electrode location outside of scala tympani independently resulted in a 10.5 per cent decrease in phoneme scores.Conclusion: Cone-beam computed tomography was valuable for demonstrating electrode position. The rate of scala tympani insertion was higher in CI532 than in CI512 electrodes. Scala vestibuli insertion and translocation were associated with poorer speech perception outcomes.
- 18 January 2018
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 19 (3) , 147-152
Co-registration of cone beam CT and preoperative MRI for improved accuracy of electrode localization following cochlear implantation
Objectives: To investigate the clinical usefulness and practicality of co-registration of Cone Beam CT (CBCT) with preoperative Magnetic Resonance Imaging (MRI) for intracochlear localization of electrodes after cochlear implantation. Methods: Images of 20 adult patients who underwent CBCT after implantation were co-registered with preoperative MRI scans. Time taken for co-registration was recorded. The images were analysed by clinicians of varying levels of expertise to determine electrode position and ease of interpretation. Results: After a short learning curve, the average co-registration time was 10.78 minutes (StdDev 2.37). All clinicians found the co-registered images easier to interpret than CBCT alone. The mean concordance of CBCT vs. co-registered image analysis between consultant otologists was 60% (17-100%) and 86% (60-100%), respectively. The sensitivity and specificity for CBCT to identify Scala Vestibuli insertion or translocation was 100 and 75%, respectively. The negative predictive value was 100%. Discussion: CBCT should be performed following adult cochlear implantation for audit and quality control of surgical technique. If SV insertion or translocation is suspected, co-registration with preoperative MRI should be performed to enable easier analysis. There will be a learning curve for this process in terms of both the co-registration and the interpretation of images by clinicians.
- 18 January 2018
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 19 (3) , 147-152
Co-registration of cone beam CT and preoperative MRI for improved accuracy of electrode localization following cochlear implantation
Objectives: To investigate the clinical usefulness and practicality of co-registration of Cone Beam CT (CBCT) with preoperative Magnetic Resonance Imaging (MRI) for intracochlear localization of electrodes after cochlear implantation. Methods: Images of 20 adult patients who underwent CBCT after implantation were co-registered with preoperative MRI scans. Time taken for co-registration was recorded. The images were analysed by clinicians of varying levels of expertise to determine electrode position and ease of interpretation. Results: After a short learning curve, the average co-registration time was 10.78 minutes (StdDev 2.37). All clinicians found the co-registered images easier to interpret than CBCT alone. The mean concordance of CBCT vs. co-registered image analysis between consultant otologists was 60% (17-100%) and 86% (60-100%), respectively. The sensitivity and specificity for CBCT to identify Scala Vestibuli insertion or translocation was 100 and 75%, respectively. The negative predictive value was 100%. Discussion: CBCT should be performed following adult cochlear implantation for audit and quality control of surgical technique. If SV insertion or translocation is suspected, co-registration with preoperative MRI should be performed to enable easier analysis. There will be a learning curve for this process in terms of both the co-registration and the interpretation of images by clinicians.
- Open Access
- 14 December 2017
- Published by Wiley in Clinical Otolaryngology
- Vol. 43 (2) , 749-753
Garden terror—Case series of twenty‐eight serious ear injuries caused by yucca plants
- 14 December 2017
- Published by Wiley in Clinical Otolaryngology
- Vol. 43 (2) , 749-753
Open AccessGarden terror—Case series of twenty‐eight serious ear injuries caused by yucca plants
- 31 October 2017
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 22 (3) , 180-189
Electrophysiological Evidence of the Basilar-Membrane Travelling Wave and Frequency Place Coding of Sound in Cochlear Implant Recipients
Aim: To obtain direct evidence for the cochlear travelling wave in humans by performing electrocochleography from within the cochlea in subjects implanted with an auditory prosthesis. Background: Sound induces a travelling wave that propagates along the basilar membrane, exhibiting cochleotopic tuning with a frequency-dependent phase delay. To date, evoked potentials and psychophysical experiments have supported the presence of the travelling wave in humans, but direct measurements have not been made. Methods: Electrical potentials in response to rarefaction and condensation acoustic tone bursts were recorded from multiple sites along the human cochlea, directly from a cochlear implant electrode during, and immediately after, its insertion. These recordings were made from individuals with residual hearing. Results: Electrocochleography was recorded from 11 intracochlear electrodes in 7 ears from 6 subjects, with detectable responses on all electrodes in 5 ears. Cochleotopic tuning and frequency-dependent phase delay of the cochlear microphonic were demonstrated. The response latencies were slightly shorter than those anticipated which we attribute to the subjects' hearing loss. Conclusions: Direct evidence for the travelling wave was observed. Electrocochleography from cochlear implant electrodes provides site-specific information on hair cell and neural function of the cochlea with potential diagnostic value.
- 31 October 2017
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 22 (3) , 180-189
Electrophysiological Evidence of the Basilar-Membrane Travelling Wave and Frequency Place Coding of Sound in Cochlear Implant Recipients
Aim: To obtain direct evidence for the cochlear travelling wave in humans by performing electrocochleography from within the cochlea in subjects implanted with an auditory prosthesis. Background: Sound induces a travelling wave that propagates along the basilar membrane, exhibiting cochleotopic tuning with a frequency-dependent phase delay. To date, evoked potentials and psychophysical experiments have supported the presence of the travelling wave in humans, but direct measurements have not been made. Methods: Electrical potentials in response to rarefaction and condensation acoustic tone bursts were recorded from multiple sites along the human cochlea, directly from a cochlear implant electrode during, and immediately after, its insertion. These recordings were made from individuals with residual hearing. Results: Electrocochleography was recorded from 11 intracochlear electrodes in 7 ears from 6 subjects, with detectable responses on all electrodes in 5 ears. Cochleotopic tuning and frequency-dependent phase delay of the cochlear microphonic were demonstrated. The response latencies were slightly shorter than those anticipated which we attribute to the subjects' hearing loss. Conclusions: Direct evidence for the travelling wave was observed. Electrocochleography from cochlear implant electrodes provides site-specific information on hair cell and neural function of the cochlea with potential diagnostic value.
- Open Access
- 23 March 2017
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 11, 141
Characterizing Electrocochleography in Cochlear Implant Recipients with Residual Low-Frequency Hearing
Objective: Lay the groundwork for using electrocochleography (ECochG) as a measure of cochlear health, by characterising typical patterns of the ECochG response observed across the electrode array in cochlear implant recipients with residual hearing. Methods: ECochG was measured immediately after electrode insertion in 45 cochlear implant recipients with residual hearing. The Cochlear Response Telemetry system was used to record ECochG across the electrode array, in response to 100- or 110-dB SPL pure tones at 0.5-kHz, presented at 14 per second and with alternating polarities. Hair cell activity, as the cochlear microphonic (CM), was estimated by taking the difference (DIF) of the two polarities. Neural activity, as the auditory nerve neurophonic (ANN), was estimated by taking the sum (SUM) of the two polarities. Prior work in humans and animal studies suggested that the expected ECochG pattern in response to a 0.5-kHz pure tone is an apical-peak in CM amplitude and latency. Results: The most prevalent pattern was a peak in the DIF amplitude near the most apical electrode, with a prolongation of latency towards the electrode tip; this was found in 21 / 39 individuals with successful ECochG recordings. The 21 apical-peak recipients had the best low-frequency hearing. A low amplitude, long-latency DIF response that remained relatively constant across the electrode array was found in 10 / 39 individuals, in a group with the poorest low- and high-frequency hearing. A third, previously undescribed, pattern occurred in 8 / 39 participants, with mid-electrode peaks in DIF amplitude. These recipients had the best high-frequency hearing and a progressive prolongation of DIF latency around the mid-electrode peaks consistent with the presence of discrete populations of hair cells. Conclusions: The presence of distinct patterns of the ECochG response with relationships to pre-operative hearing levels supports the notion that ECochG across the electrode array functions as a measure of cochlear health.
- 23 March 2017
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 11, 141
Open AccessCharacterizing Electrocochleography in Cochlear Implant Recipients with Residual Low-Frequency Hearing
Objective: Lay the groundwork for using electrocochleography (ECochG) as a measure of cochlear health, by characterising typical patterns of the ECochG response observed across the electrode array in cochlear implant recipients with residual hearing. Methods: ECochG was measured immediately after electrode insertion in 45 cochlear implant recipients with residual hearing. The Cochlear Response Telemetry system was used to record ECochG across the electrode array, in response to 100- or 110-dB SPL pure tones at 0.5-kHz, presented at 14 per second and with alternating polarities. Hair cell activity, as the cochlear microphonic (CM), was estimated by taking the difference (DIF) of the two polarities. Neural activity, as the auditory nerve neurophonic (ANN), was estimated by taking the sum (SUM) of the two polarities. Prior work in humans and animal studies suggested that the expected ECochG pattern in response to a 0.5-kHz pure tone is an apical-peak in CM amplitude and latency. Results: The most prevalent pattern was a peak in the DIF amplitude near the most apical electrode, with a prolongation of latency towards the electrode tip; this was found in 21 / 39 individuals with successful ECochG recordings. The 21 apical-peak recipients had the best low-frequency hearing. A low amplitude, long-latency DIF response that remained relatively constant across the electrode array was found in 10 / 39 individuals, in a group with the poorest low- and high-frequency hearing. A third, previously undescribed, pattern occurred in 8 / 39 participants, with mid-electrode peaks in DIF amplitude. These recipients had the best high-frequency hearing and a progressive prolongation of DIF latency around the mid-electrode peaks consistent with the presence of discrete populations of hair cells. Conclusions: The presence of distinct patterns of the ECochG response with relationships to pre-operative hearing levels supports the notion that ECochG across the electrode array functions as a measure of cochlear health.
- Open Access
- 18 November 2016
- Published by Hamad bin Khalifa University Press (HBKU Press) in Journal of Emergency Medicine, Trauma and Acute Care
- Vol. 2016 (3)
Management of traumatic hyoid bone fractures: A case series
Purpose: Hyoid bone fractures are uncommon, reported mainly in cases of hanging. There is a paucity of reports involving other mechanisms, and only a handful of case reports are available to guide the management of these fractures, especially within the emergency department setting. This study focused on identifying optimal initial airway management and subsequent treatment of patients with hyoid fractures. Methods: Patients presenting to an adult major trauma referral centre between January 2007 and July 2014 with a diagnosis of hyoid bone fracture were identified. Patient records were reviewed retrospectively. Results: Of the 19 patients identified, 16 cases were secondary to blunt force trauma. Motor vehicle crashes accounted for eight of the 19 cases. All patients with major trauma were intubated as part of their initial airway management, while 50% of the minor trauma patients were intubated. Only one patient underwent surgical repair of the hyoid bone. Most patients experienced excellent outcomes with no hyoid fracture-related complications. Conclusion: Early intubation for suspected hyoid fractures is advised for those with a penetrating mechanism of injury, clinical features of airway compromise, and severe associated injuries. Conservative, nonsurgical management of hyoid fractures remains the mainstay of management. A minimum 24-hour period of observation for patients who are not managed with endotracheal intubation is advised.
- 18 November 2016
- Published by Hamad bin Khalifa University Press (HBKU Press) in Journal of Emergency Medicine, Trauma and Acute Care
- Vol. 2016 (3)
Open AccessManagement of traumatic hyoid bone fractures: A case series
Purpose: Hyoid bone fractures are uncommon, reported mainly in cases of hanging. There is a paucity of reports involving other mechanisms, and only a handful of case reports are available to guide the management of these fractures, especially within the emergency department setting. This study focused on identifying optimal initial airway management and subsequent treatment of patients with hyoid fractures. Methods: Patients presenting to an adult major trauma referral centre between January 2007 and July 2014 with a diagnosis of hyoid bone fracture were identified. Patient records were reviewed retrospectively. Results: Of the 19 patients identified, 16 cases were secondary to blunt force trauma. Motor vehicle crashes accounted for eight of the 19 cases. All patients with major trauma were intubated as part of their initial airway management, while 50% of the minor trauma patients were intubated. Only one patient underwent surgical repair of the hyoid bone. Most patients experienced excellent outcomes with no hyoid fracture-related complications. Conclusion: Early intubation for suspected hyoid fractures is advised for those with a penetrating mechanism of injury, clinical features of airway compromise, and severe associated injuries. Conservative, nonsurgical management of hyoid fractures remains the mainstay of management. A minimum 24-hour period of observation for patients who are not managed with endotracheal intubation is advised.
- 1 January 2015
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 141 (1) , 5-11
Sites of Origin of Oral Cavity Cancer in Nonsmokers vs Smokers
Research from JAMA Otolaryngology–Head & Neck Surgery — Sites of Origin of Oral Cavity Cancer in Nonsmokers vs Smokers — Possible Evidence of Dental Trauma Carcinogenesis and Its Importance Compared With Human Papillomavirus
- 1 January 2015
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 141 (1) , 5-11
Sites of Origin of Oral Cavity Cancer in Nonsmokers vs Smokers
Research from JAMA Otolaryngology–Head & Neck Surgery — Sites of Origin of Oral Cavity Cancer in Nonsmokers vs Smokers — Possible Evidence of Dental Trauma Carcinogenesis and Its Importance Compared With Human Papillomavirus