Punathil Vasu Suneesh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Punathil Vasu Suneesh has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Satheesh Babu Thekkedath Gopalakrishnan
Amrita Vishwa Vidyapeetham
13 shared publications Bipin G. Nair
Amrita School of Biotechnology, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam − 690525, India
7 shared publicationsT. Ramachandran
Department of Sciences, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, 641112, India
6 shared publications- Bipin Nair
School of Biotechnology, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam 690525, Kerala, India
4 shared publications Punnakkal Navaneeth
4 shared publicationsAarathi Pradeep
Department of Chemistry, Amrita School of Physical Sciences, Coimbatore, Amrita Vishwa Vidyapeetham − 641112, India
3 shared publications
Latest Publications
- Open Access
- 25 August 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (33) , e74257
Improved Electrochemical Performance of Activated Carbon Nanofibers for Supercapacitor Applications in Redox Additive Electrolytes
The choice of suitable materials and additives along with their effective integration, plays a key role in enriching the supercapacitor behavior. Among the various emerging materials, carbon‐based electrodes have garnered substantial focus toward their potential in energy field. Recently, redox additives have been investigated as superior alternatives to conventional aqueous electrolytes. The current work deals with the development of activated carbon nanofiber with KOH and NaHCO 3 as chemical activating agents and explores their usefulness as a supercapacitor in redox additive. The NaHCO 3 activated carbon nanofiber (CNF) achieved the specific capacitance of 399 and 1482 F/g at 3 A/g in 1 M H 2 SO 4 without and with hydroquinone, respectively. Both XPS and EDAX analyses revealed the presence of heteroatoms that too participates in acidic electrolyte during half‐cell analysis. In hydroquinone incorporated acidic electrolyte, the NaHCO 3 ‐activated CNF‐derived symmetric supercapacitor realized 25.6 Wh/kg as the energy density at 3 A/g and 80% capacitance maintained after 5000 rounds of GCD at 10 A/g.
- 25 August 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (33) , e74257
Open AccessImproved Electrochemical Performance of Activated Carbon Nanofibers for Supercapacitor Applications in Redox Additive Electrolytes
The choice of suitable materials and additives along with their effective integration, plays a key role in enriching the supercapacitor behavior. Among the various emerging materials, carbon‐based electrodes have garnered substantial focus toward their potential in energy field. Recently, redox additives have been investigated as superior alternatives to conventional aqueous electrolytes. The current work deals with the development of activated carbon nanofiber with KOH and NaHCO 3 as chemical activating agents and explores their usefulness as a supercapacitor in redox additive. The NaHCO 3 activated carbon nanofiber (CNF) achieved the specific capacitance of 399 and 1482 F/g at 3 A/g in 1 M H 2 SO 4 without and with hydroquinone, respectively. Both XPS and EDAX analyses revealed the presence of heteroatoms that too participates in acidic electrolyte during half‐cell analysis. In hydroquinone incorporated acidic electrolyte, the NaHCO 3 ‐activated CNF‐derived symmetric supercapacitor realized 25.6 Wh/kg as the energy density at 3 A/g and 80% capacitance maintained after 5000 rounds of GCD at 10 A/g.
- Open Access
- 8 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Copper and nickel doped carbon dots for rapid and sensitive fluorescent turn-off detection of bilirubin
Carbon dots doped with metals and non-metals have gained much popularity due to the enhancement in their optical and electronic properties. In this study, polyethyleneimine-functionalized transition metal (nickel or copper) doped carbon dots (CD, NiCD and CuCD) were synthesized through hydrothermal method. The carbon dots exhibited a blue fluorescence at 470 nm when excited at 350 nm. The as-synthesized carbon dots were utilised for the fluorimetric detection of bilirubin in the range 0.5 µM – 280 µM, with CuCD exhibiting the highest sensitivity of 155.38 a.u/log µM in the concentration range 0.5 to 10 µM and 84.01 a.u/ log µM in the concentration range 10 to 280 µM. CuCD also exhibited the lowest limit of detection of 0.0907 µM and the lowest limit of quantification of 0.3023 µM. All the carbon dots showed negligible interference in the presence of biomolecules and metal ions present in human serum implying the remarkable selectivity of the method to bilirubin detection. Further, the carbon dots were successfully tested for their real-time application in human serum using bilirubin-spiked serum samples.
- 8 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessCopper and nickel doped carbon dots for rapid and sensitive fluorescent turn-off detection of bilirubin
Carbon dots doped with metals and non-metals have gained much popularity due to the enhancement in their optical and electronic properties. In this study, polyethyleneimine-functionalized transition metal (nickel or copper) doped carbon dots (CD, NiCD and CuCD) were synthesized through hydrothermal method. The carbon dots exhibited a blue fluorescence at 470 nm when excited at 350 nm. The as-synthesized carbon dots were utilised for the fluorimetric detection of bilirubin in the range 0.5 µM – 280 µM, with CuCD exhibiting the highest sensitivity of 155.38 a.u/log µM in the concentration range 0.5 to 10 µM and 84.01 a.u/ log µM in the concentration range 10 to 280 µM. CuCD also exhibited the lowest limit of detection of 0.0907 µM and the lowest limit of quantification of 0.3023 µM. All the carbon dots showed negligible interference in the presence of biomolecules and metal ions present in human serum implying the remarkable selectivity of the method to bilirubin detection. Further, the carbon dots were successfully tested for their real-time application in human serum using bilirubin-spiked serum samples.
- 3 June 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (6) , 067504
Non-Enzymatic Electrochemical Detection of Urine Creatinine Using Cobalt-Gold Bimetallic Nanoparticles
This work presents the development of a non-enzymatic electrochemical sensor for creatinine in a neutral medium using a cobalt-gold bimetallic nanoparticles modified platinum electrode. The voltammetric detection of creatinine in a neutral phosphate buffer was based on the formation of a soluble cobalt-creatinine complex. The sensor exhibited good selectivity and a detection limit (S/N = 3) of 2.25 mM with two linear ranges from 6.4 to 83.2 mM. The sensitivity of the sensor was 0.621 and 1.135 μA mM−1 cm−2 at lower (6.4–51.2 mM) and higher (51.2–83.2 mM) detection ranges, respectively. The sensor performance was validated using urine samples and creatinine spiked urine samples.
- 3 June 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (6) , 067504
Non-Enzymatic Electrochemical Detection of Urine Creatinine Using Cobalt-Gold Bimetallic Nanoparticles
This work presents the development of a non-enzymatic electrochemical sensor for creatinine in a neutral medium using a cobalt-gold bimetallic nanoparticles modified platinum electrode. The voltammetric detection of creatinine in a neutral phosphate buffer was based on the formation of a soluble cobalt-creatinine complex. The sensor exhibited good selectivity and a detection limit (S/N = 3) of 2.25 mM with two linear ranges from 6.4 to 83.2 mM. The sensitivity of the sensor was 0.621 and 1.135 μA mM−1 cm−2 at lower (6.4–51.2 mM) and higher (51.2–83.2 mM) detection ranges, respectively. The sensor performance was validated using urine samples and creatinine spiked urine samples.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20805-20812
A User-Configurable Smartwatch as a Point-of-Care Testing Device for Electrochemical Biosensors
The paper presents the development of a wristwatch as a configurable testing platform for personalized point-of-care testing. The developed watch can perform voltammetry and amperometry in a wide operating range, thus making the system capable of detecting various bio-analytes. This overcomes a major limitation of the existing meters available in the market, where each sensor requires a dedicated meter. The user selects the desired biomolecule for quantification on the smartphone using the developed Android mobile application. The test parameters are transferred via Bluetooth, and the smartwatch is tuned to the chosen sensor. As a proof-of-concept, we have developed electrochemical biosensors for testing clinically significant biomolecules like glucose, uric acid and ascorbic acid, which was then interfaced with the smartwatch for the on-demand quantification. Using an ADC with 12-bit resolution, the device demonstrated a high resolution of 0.732 mV. The smartwatch could overcome the limitation associated with the quantification of uric acid in the presence of ascorbic acid by doing baseline subtraction, and the results show a low relative standard deviation of 4%. The glucose analysis was highly reproducible with a relative standard deviation of 4.95%, with a high resolution of 0.0217 mg dL -1 , and the results could be obtained within 5 s. The results obtained using the smartwatch were in excellent conformity with those obtained from a laboratory electrochemical workstation. The key advantage of the device is that it can be easily configured to test any new biomarkers without any hardware change by over-the-air mobile application updates.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20805-20812
A User-Configurable Smartwatch as a Point-of-Care Testing Device for Electrochemical Biosensors
The paper presents the development of a wristwatch as a configurable testing platform for personalized point-of-care testing. The developed watch can perform voltammetry and amperometry in a wide operating range, thus making the system capable of detecting various bio-analytes. This overcomes a major limitation of the existing meters available in the market, where each sensor requires a dedicated meter. The user selects the desired biomolecule for quantification on the smartphone using the developed Android mobile application. The test parameters are transferred via Bluetooth, and the smartwatch is tuned to the chosen sensor. As a proof-of-concept, we have developed electrochemical biosensors for testing clinically significant biomolecules like glucose, uric acid and ascorbic acid, which was then interfaced with the smartwatch for the on-demand quantification. Using an ADC with 12-bit resolution, the device demonstrated a high resolution of 0.732 mV. The smartwatch could overcome the limitation associated with the quantification of uric acid in the presence of ascorbic acid by doing baseline subtraction, and the results show a low relative standard deviation of 4%. The glucose analysis was highly reproducible with a relative standard deviation of 4.95%, with a high resolution of 0.0217 mg dL -1 , and the results could be obtained within 5 s. The results obtained using the smartwatch were in excellent conformity with those obtained from a laboratory electrochemical workstation. The key advantage of the device is that it can be easily configured to test any new biomarkers without any hardware change by over-the-air mobile application updates.
- 1 August 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (8) , 087515
Alkaline Hematin-Based Disposable Electrochemical Sensor for Haemoglobin
Estimating haemoglobin levels in the blood is crucial as it indicates various diseased conditions, including anaemia, cancers, and liver, kidney, and lung diseases. This paper presents the fabrication of an electrochemical biosensor to estimate haemoglobin in alkaline conditions. The rifting of the quaternary structure of the haemoglobin under high alkaline conditions paves the pathway for the formation of alkaline hematin. Graphite-kaolin clay composite electrocatalyst was synthesized and screen printed on a disposable electrode for the direct electrooxidation of alkaline hematin. The sensor exhibited high selectivity, linear responses over a concentration range from 10 to 80 μM, and a sensitivity of 43.26 μA μM−1 cm−2. The performance of the sensor was validated by testing it with whole blood samples. The novelty of the work lies in the direct electrooxidation of alkaline hematin on the disposable screen-printed electrode without any cell separation or cell lysing steps.
- 1 August 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (8) , 087515
Alkaline Hematin-Based Disposable Electrochemical Sensor for Haemoglobin
Estimating haemoglobin levels in the blood is crucial as it indicates various diseased conditions, including anaemia, cancers, and liver, kidney, and lung diseases. This paper presents the fabrication of an electrochemical biosensor to estimate haemoglobin in alkaline conditions. The rifting of the quaternary structure of the haemoglobin under high alkaline conditions paves the pathway for the formation of alkaline hematin. Graphite-kaolin clay composite electrocatalyst was synthesized and screen printed on a disposable electrode for the direct electrooxidation of alkaline hematin. The sensor exhibited high selectivity, linear responses over a concentration range from 10 to 80 μM, and a sensitivity of 43.26 μA μM−1 cm−2. The performance of the sensor was validated by testing it with whole blood samples. The novelty of the work lies in the direct electrooxidation of alkaline hematin on the disposable screen-printed electrode without any cell separation or cell lysing steps.
- 26 October 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 287 (Pt 1) , 122045
A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample
- 26 October 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 287 (Pt 1) , 122045
A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample