Genaro Saavedra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Genaro Saavedra has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Martinez-Corral
Universitat de València
105 shared publications - Emilio Sánchez-Ortiga
Universitat Politècnica de València
30 shared publications - Ana Doblas
University of Massachusetts Dartmouth
29 shared publications - Raúl Martínez-Cuenca
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain
27 shared publications - Walter D. Furlan
Departamento de Óptica, Optometría y CC de la Visión, Universitat de València, 46100 Burjassot, Spain
22 shared publications Bahram Javidi
Electrical and Computer Engineering Department, University of Connecticut, Storrs, CT, USA
19 shared publications
Latest Publications
- 24 February 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (5) , 9199-9212
Compact extended-DOF microscope through electrowetting lens
In optical microscopy, the intrinsic trade-off between resolution and depth of field (DOF) prevents the observation of 3D samples, limiting the observable thickness to some micrometers. The usual solution to this problem is to mechanically scan the object in depth. However, this slows down the process and can induce vibrations in soft samples. To overcome these drawbacks, we propose the use of an electrically tunable lens (ETL) based on electrowetting effect. Specifically, we propose an extended-DOF microscope set up in a very compact architecture in which full telecentricity is no longer achieved. On top of that, the axial scanning is carried out by the non-afocal coupling between two M12 lenses and the ETL. The main feature of the proposed extended-DOF microscope is that, despite its compactness, it can capture stacks of images with long depth range, constant magnification and a spatial resolution that equals that of the standard microscope and remains invariant along the depth range. We also show that the proposed idea can be implemented as an add-on attachable to any commercial microscope, which enables the use of all the microscope facilities.
- 24 February 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (5) , 9199-9212
Compact extended-DOF microscope through electrowetting lens
In optical microscopy, the intrinsic trade-off between resolution and depth of field (DOF) prevents the observation of 3D samples, limiting the observable thickness to some micrometers. The usual solution to this problem is to mechanically scan the object in depth. However, this slows down the process and can induce vibrations in soft samples. To overcome these drawbacks, we propose the use of an electrically tunable lens (ETL) based on electrowetting effect. Specifically, we propose an extended-DOF microscope set up in a very compact architecture in which full telecentricity is no longer achieved. On top of that, the axial scanning is carried out by the non-afocal coupling between two M12 lenses and the ETL. The main feature of the proposed extended-DOF microscope is that, despite its compactness, it can capture stacks of images with long depth range, constant magnification and a spatial resolution that equals that of the standard microscope and remains invariant along the depth range. We also show that the proposed idea can be implemented as an add-on attachable to any commercial microscope, which enables the use of all the microscope facilities.
- 17 October 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (22) , 36568-36589
Management of the axial modulation of the illumination pattern in structured illumination microscopy using an extended illumination source
We have designed and implemented an approach for three-dimensional (3D) structured illumination (SI) microscopy (SIM) based on a quasi-monochromatic extended source illuminating a Wollaston prism to improve robustness, light efficiency and flexibility over our previous design. We show through analytical and experimental verification of the presented theoretical framework for our proposed tunable structured illumination microscopy (TSIM) system, that a simple and accurate determination of the axial modulation of the SI pattern is achieved, enabling a realistic characterization of the system’s effective optical transfer function (OTF). System performance as a function of the extended source size is investigated with simulations. Results from a comparative performance analysis of the proposed TSIM system and traditional SIM systems show some advantages over the traditional two-wave and three-wave interference SIM systems. We show that by controlling the source size and thereby the axial modulation of the 3D SI pattern, the TSIM scheme offers increased OTF compact support and improved optical sectioning capability, quantified by the integrated intensity, under certain conditions, which may be desirable when imaging optically thick samples. The additional tunability of the 3D SI pattern, provides a unique opportunity for OTF engineering in our TSIM system.
- 17 October 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (22) , 36568-36589
Management of the axial modulation of the illumination pattern in structured illumination microscopy using an extended illumination source
We have designed and implemented an approach for three-dimensional (3D) structured illumination (SI) microscopy (SIM) based on a quasi-monochromatic extended source illuminating a Wollaston prism to improve robustness, light efficiency and flexibility over our previous design. We show through analytical and experimental verification of the presented theoretical framework for our proposed tunable structured illumination microscopy (TSIM) system, that a simple and accurate determination of the axial modulation of the SI pattern is achieved, enabling a realistic characterization of the system’s effective optical transfer function (OTF). System performance as a function of the extended source size is investigated with simulations. Results from a comparative performance analysis of the proposed TSIM system and traditional SIM systems show some advantages over the traditional two-wave and three-wave interference SIM systems. We show that by controlling the source size and thereby the axial modulation of the 3D SI pattern, the TSIM scheme offers increased OTF compact support and improved optical sectioning capability, quantified by the integrated intensity, under certain conditions, which may be desirable when imaging optically thick samples. The additional tunability of the 3D SI pattern, provides a unique opportunity for OTF engineering in our TSIM system.
- 28 June 2023
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 40 (7) , 1451-1467
Analytic plenoptic camera diffraction model and radial distortion analysis due to vignetting
Using a mathematical approach, this paper presents a generalization of semi-analytical expressions for the point spread function (PSF) of plenoptic cameras. The model is applicable in the standard regime of the scalar diffraction theory while the extension to arbitrary main lens transmission functions generalizes a priori formalism. The accuracy and applicability of the model is well verified against the exact Rayleigh-Sommerfeld diffraction integral and a rigorous proof of convergence for the PSF series expression is made. Since vignetting can never be fully eliminated, it is critical to inspect the image degradation it poses through distortions. For what we believe is the first time, diffractive distortions in the diffraction-limited plenoptic camera are closely examined and demonstrated to exceed those that would otherwise be estimated by a geometrical optics formalism, further justifying the necessity of an approach based on wave optics. Microlenses subject to the edge diffraction effects of the main lens vignetting are shown to translate into radial distortions of increasing severity and instability with defocus. The distortions due to vignetting are found to be typically bound by the radius of the geometrical defocus in the image plane, while objects confined to the depth of field give rise to merely subpixel distortions.& COPY; 2023 Optica Publishing Group
- 28 June 2023
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 40 (7) , 1451-1467
Analytic plenoptic camera diffraction model and radial distortion analysis due to vignetting
Using a mathematical approach, this paper presents a generalization of semi-analytical expressions for the point spread function (PSF) of plenoptic cameras. The model is applicable in the standard regime of the scalar diffraction theory while the extension to arbitrary main lens transmission functions generalizes a priori formalism. The accuracy and applicability of the model is well verified against the exact Rayleigh-Sommerfeld diffraction integral and a rigorous proof of convergence for the PSF series expression is made. Since vignetting can never be fully eliminated, it is critical to inspect the image degradation it poses through distortions. For what we believe is the first time, diffractive distortions in the diffraction-limited plenoptic camera are closely examined and demonstrated to exceed those that would otherwise be estimated by a geometrical optics formalism, further justifying the necessity of an approach based on wave optics. Microlenses subject to the edge diffraction effects of the main lens vignetting are shown to translate into radial distortions of increasing severity and instability with defocus. The distortions due to vignetting are found to be typically bound by the radius of the geometrical defocus in the image plane, while objects confined to the depth of field give rise to merely subpixel distortions.& COPY; 2023 Optica Publishing Group
- Open Access
- 29 October 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 161
Fast and robust wave optics-based reconstruction protocol for Fourier lightfield microscopy
- 29 October 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 161
Open AccessFast and robust wave optics-based reconstruction protocol for Fourier lightfield microscopy
- Open Access
Handheld and Cost-Effective Fourier Lightfield Microscope
In this work, the design, building, and testing of the most portable, easy-to-build, robust, handheld, and cost-effective Fourier Lightfield Microscope (FLMic) to date is reported. The FLMic is built by means of a surveillance camera lens and additional off-the-shelf optical elements, resulting in a cost-effective FLMic exhibiting all the regular sought features in lightfield microscopy, such as refocusing and gathering 3D information of samples by means of a single-shot approach. The proposed FLMic features reduced dimensions and light weight, which, combined with its low cost, turn the presented FLMic into a strong candidate for in-field application where 3D imaging capabilities are pursued. The use of cost-effective optical elements has a relatively low impact on the optical performance, regarding the figures dictated by the theory, while its price can be at least 100 times lower than that of a regular FLMic. The system operability is tested in both bright-field and fluorescent modes by imaging a resolution target, a honeybee wing, and a knot of dyed cotton fibers.
Open AccessHandheld and Cost-Effective Fourier Lightfield Microscope
In this work, the design, building, and testing of the most portable, easy-to-build, robust, handheld, and cost-effective Fourier Lightfield Microscope (FLMic) to date is reported. The FLMic is built by means of a surveillance camera lens and additional off-the-shelf optical elements, resulting in a cost-effective FLMic exhibiting all the regular sought features in lightfield microscopy, such as refocusing and gathering 3D information of samples by means of a single-shot approach. The proposed FLMic features reduced dimensions and light weight, which, combined with its low cost, turn the presented FLMic into a strong candidate for in-field application where 3D imaging capabilities are pursued. The use of cost-effective optical elements has a relatively low impact on the optical performance, regarding the figures dictated by the theory, while its price can be at least 100 times lower than that of a regular FLMic. The system operability is tested in both bright-field and fluorescent modes by imaging a resolution target, a honeybee wing, and a knot of dyed cotton fibers.
- 27 October 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11925, 22-69
3D imaging through Fourier lightfield microscopy
Lightfield (also known as integral or plenoptic) microscopy has been introduced successfully in 3D bioimaging. The strongest point of this technique when compared with conventional 3D microscopy arquitectures is its capability of capturing the 3D information of the sample in a single-shot manner. Despite this advantage, lightfield microscopy currently faces some challenges, like improving the resolution and depth of field of the reconstructed specimens or the development and optimization of specially-adapted reconstruction algorithms. In this contribution we review a new paradigm, namely, the Fourier lightfield microscope (FLMic), that improves the capabilities of the technique and we present recent advances and applications of this new architecture. As an example, we describe a protocol that takes profit from FLMic concept for providing, in a single-shot, 3D dark-field images of volumetric transparent samples.
- 27 October 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11925, 22-69
3D imaging through Fourier lightfield microscopy
Lightfield (also known as integral or plenoptic) microscopy has been introduced successfully in 3D bioimaging. The strongest point of this technique when compared with conventional 3D microscopy arquitectures is its capability of capturing the 3D information of the sample in a single-shot manner. Despite this advantage, lightfield microscopy currently faces some challenges, like improving the resolution and depth of field of the reconstructed specimens or the development and optimization of specially-adapted reconstruction algorithms. In this contribution we review a new paradigm, namely, the Fourier lightfield microscope (FLMic), that improves the capabilities of the technique and we present recent advances and applications of this new architecture. As an example, we describe a protocol that takes profit from FLMic concept for providing, in a single-shot, 3D dark-field images of volumetric transparent samples.
- Open Access
The Lightfield Microscope Eyepiece
Lightfield microscopy has raised growing interest in the last few years. Its ability to get three-dimensional information about the sample in a single shot makes it suitable for many applications in which time resolution is fundamental. In this paper we present a novel device, which is capable of converting any conventional microscope into a lightfield microscope. Based on the Fourier integral microscope concept, we designed the lightfield microscope eyepiece. This is coupled to the eyepiece port, to let the user exploit all the host microscope’s components (objective turret, illumination systems, translation stage, etc.) and get a 3D reconstruction of the sample. After the optical design, a proof-of-concept device was built with off-the-shelf optomechanical components. Here, its optical performances are demonstrated, which show good matching with the theoretical ones. Then, the pictures of different samples taken with the lightfield eyepiece are shown, along with the corresponding reconstructions. We demonstrated the functioning of the lightfield eyepiece and lay the foundation for the development of a commercial device that works with any microscope.
Open AccessThe Lightfield Microscope Eyepiece
Lightfield microscopy has raised growing interest in the last few years. Its ability to get three-dimensional information about the sample in a single shot makes it suitable for many applications in which time resolution is fundamental. In this paper we present a novel device, which is capable of converting any conventional microscope into a lightfield microscope. Based on the Fourier integral microscope concept, we designed the lightfield microscope eyepiece. This is coupled to the eyepiece port, to let the user exploit all the host microscope’s components (objective turret, illumination systems, translation stage, etc.) and get a 3D reconstruction of the sample. After the optical design, a proof-of-concept device was built with off-the-shelf optomechanical components. Here, its optical performances are demonstrated, which show good matching with the theoretical ones. Then, the pictures of different samples taken with the lightfield eyepiece are shown, along with the corresponding reconstructions. We demonstrated the functioning of the lightfield eyepiece and lay the foundation for the development of a commercial device that works with any microscope.
- Open Access
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 203117-203133
Robust Light Field Watermarking by 4D Wavelet Transform
Unlike common 2D images, the light field representation of a scene delivers spatial and angular description which is of paramount importance for 3D reconstruction. Despite the numerous methods proposed for 2D image watermarking, such methods do not address the angular information of the light field. Hence the exploitation of such methods may cause severe destruction of the angular information. In this paper, we propose a novel method for light field watermarking with extensive consideration of the spatial and angular information. Considering the 4D innate of the light field, the proposed method incorporates 4D wavelet for the purpose of watermarking and converts the heavily-correlated channels from RGB domain to YUV. The robustness of the proposed method has been evaluated against common image processing attacks.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 203117-203133
Open AccessRobust Light Field Watermarking by 4D Wavelet Transform
Unlike common 2D images, the light field representation of a scene delivers spatial and angular description which is of paramount importance for 3D reconstruction. Despite the numerous methods proposed for 2D image watermarking, such methods do not address the angular information of the light field. Hence the exploitation of such methods may cause severe destruction of the angular information. In this paper, we propose a novel method for light field watermarking with extensive consideration of the spatial and angular information. Considering the 4D innate of the light field, the proposed method incorporates 4D wavelet for the purpose of watermarking and converts the heavily-correlated channels from RGB domain to YUV. The robustness of the proposed method has been evaluated against common image processing attacks.
- Open Access
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 14944-14952
Optical Sectioning Microscopy Through Single-Shot Lightfield Protocol
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 14944-14952
Open AccessOptical Sectioning Microscopy Through Single-Shot Lightfield Protocol
- Open Access
Robust Depth Estimation for Light Field Microscopy
Light field technologies have seen a rise in recent years and microscopy is a field where such technology has had a deep impact. The possibility to provide spatial and angular information at the same time and in a single shot brings several advantages and allows for new applications. A common goal in these applications is the calculation of a depth map to reconstruct the three-dimensional geometry of the scene. Many approaches are applicable, but most of them cannot achieve high accuracy because of the nature of such images: biological samples are usually poor in features and do not exhibit sharp colors like natural scene. Due to such conditions, standard approaches result in noisy depth maps. In this work, a robust approach is proposed where accurate depth maps can be produced exploiting the information recorded in the light field, in particular, images produced with Fourier integral Microscope. The proposed approach can be divided into three main parts. Initially, it creates two cost volumes using different focal cues, namely correspondences and defocus. Secondly, it applies filtering methods that exploit multi-scale and super-pixels cost aggregation to reduce noise and enhance the accuracy. Finally, it merges the two cost volumes and extracts a depth map through multi-label optimization.
Open AccessRobust Depth Estimation for Light Field Microscopy
Light field technologies have seen a rise in recent years and microscopy is a field where such technology has had a deep impact. The possibility to provide spatial and angular information at the same time and in a single shot brings several advantages and allows for new applications. A common goal in these applications is the calculation of a depth map to reconstruct the three-dimensional geometry of the scene. Many approaches are applicable, but most of them cannot achieve high accuracy because of the nature of such images: biological samples are usually poor in features and do not exhibit sharp colors like natural scene. Due to such conditions, standard approaches result in noisy depth maps. In this work, a robust approach is proposed where accurate depth maps can be produced exploiting the information recorded in the light field, in particular, images produced with Fourier integral Microscope. The proposed approach can be divided into three main parts. Initially, it creates two cost volumes using different focal cues, namely correspondences and defocus. Secondly, it applies filtering methods that exploit multi-scale and super-pixels cost aggregation to reduce noise and enhance the accuracy. Finally, it merges the two cost volumes and extracts a depth map through multi-label optimization.